P700 Series rotary actuators

Similar documents
1805 Series Relief Valves

167D Series Switching Valves

Fisher 377 Trip Valve

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

289 Series Spring-Loaded Relief Valves

Type 119 Control Valve

1301 Series High-Pressure Regulators

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Fisher 2625, 2625SST, and 2625NS Volume Boosters

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Float and Thermostatic Traps Series H, C and X

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Your safety and the safety of others are very important.

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Baumann Mikroseal Control Valve

Fisher 377 Trip Valve

Types 66R and 66RR Low-Pressure Relief Valves

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Baumann Little Scotty Bronze Control Valve

Baumann Way Bronze or Stainless Steel Control Valve

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

VW Caddy W INSTALLATION INSTRUCTIONS

MP8000 Series Pneumatic Valve Actuators

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

2100 AD Mirror Elevator Ball Nut Replacement Procedure

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

1000-LB. TRAILER JACK OWNER S MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

NITROUS TRANSFER PUMP INSTRUCTIONS

67C Series Instrument Supply Regulators

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

TYPE E Main Valve Sizes 3 /8 through 12

Baumann Flexsleev Sanitary Control Valve

Model 43AP Pneumatic Controller, Style B

Stainless Steel Single and Dual Circulation Kits

PRESSURE REDUCING CONTROL VALVE

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

James M. Pleasants Company

SELECTION, APPLICATION AND MAINTENANCE

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Type 92S Pilot-Operated Steam Regulator

MODEL T200-F18 MODEL T125-F18 Finish Nailers

SELECTION, APPLICATION & MAINTENANCE

Unit 24: Applications of Pneumatics and Hydraulics

Installation, Operation and Maintenance Manual for Pilot Operated Valves

Fisher 249 Caged Displacer Sensors

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

LPM-06 CONVERSION KIT

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

TOOL SCHEMATIC AND PARTS MODEL 3150/38 W16R STAPLER

How Do I Replacing My Rear Brake Pads and Rotors?

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Your safety and the safety of others are very important.

HYDRAULIC LIFT TABLE CART 2200-LB.

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

INSTALLATION MANUAL MODEL RP-100

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE.

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

IOM SERIES 820-E/P Electro-Pneumatic Positioner

DYNA RIDER FOOTBOARD KIT

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Guide to good leak testing

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Fuel Injection Pump, Rotary ( )

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

TECHNICAL SERVICE MANUAL

PNEUMATIC PLANISHING HAMMER

TABLE OF CONTENTS. Section 1 - Assembling your new pit bike.

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Fisher CV500 Rotary Globe Control Valve

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Powers Controls TH 192 S Single Temperature Room Thermostat

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Fisher 657 and 667 Diaphragm Actuators

SAFETY & OPERATING INSTRUCTIONS

Cable Drum Installation

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Installation Instructions

Transcription:

Instruction Manual P700 Series March 2014 P700 Series rotary actuators P1131 P1132 TyPe P713 P1715 TyPe P723 TyPe P731 P1135 P1134 TyPe P714 TyPe P739 Figure 1. P700 Series Rotary Actuators! WarNINg failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. fisher equipment must be installed, operated, and maintained in accordance with federal, state and local codes and emerson Process Management regulator Technologies, Inc. (regulator Technologies) instructions. The installation must also comply with NfPa No. 58, ansi K61.1 and D.o.T standards. only personnel trained in the proper procedures, codes, standards and regulations of the lp-gas or anhydrous ammonia (NH 3 ) industries shall install and service this equipment. Warranty Note The use of non-fisher actuators will void internal valve warranty and may result in leakage of the gland packing caused by premature wear. In addition to premature wear, the use of non-fisher actuators may result in lower than expected flow rates and possible leakage across the valve seats. D450336T012 www.fisherregulators.com

Specifications Specifications for the P700 Series is listed on Specifications section and Table 1. The specifications for a given construction as it originally comes from the factory are stamped on nameplates. Available Configuration See Figure 2 Pressure Source Air, Nitrogen, Carbon Dioxide or Propane Vapor Minimum Actuator Pressure Limits Types P713, P723 and P739: 25 psig / 1.7 bar Type P714: 40 psig / 2.8 bar Type P731: 50 psig / 3.4 bar Maximum Actuator Pressure Limits (1) 125 psig / 8.6 bar Temperature Capabilities (1) -20 to 150 F / -29 to 66 C Return Mechanism Spring only no air Thermal Release Fuse plug installed in the pressure supply line with release melt point of 212 F / 100 C. Approximate Weight 5.6 pounds / 2.54 kg 1. The pressure and/or temperature limits listed in this Instruction Manual and any applicable standard limitation should not be exceeded. P - 7 3 9 Code Description 1 1-1/4-inch Valve 3 3-inch Valve 4 4-inch Valve 9 Multiple Sizes 1 Single Flange 2 Double Flange 3 NPT 7 Internal Valves Rotary Actuator Figure 2. P700 Series Product Numbering Table 1. Rotary Actuators Information Operating Pressure Valve Size, INCH Valve Type Actuator Size Actuator Type Description psig bar 1-1/4 C407-10 G21K1 P731 1-1/4-inch NPT 50 to 125 3.4 to 8.6 2 C477-16 G31K1 P739 2-inch NPT 25 to 125 1.7 to 8.6 3 C477-24 G31K1 P739 3-inch NPT 25 to 125 1.7 to 8.6 3 C484-24 G31K1 P713 3-inch Single Flange 25 to 125 1.7 to 8.6 3 C483-24 G31K1 P723 3-inch Double Flange 25 to 125 1.7 to 8.6 4 C404-32 G74K1 P714 4-inch Single Flange 40 to 125 2.8 to 8.6 Introduction Scope of the Manual This manual covers instructions for the Types P731, P739, P713, P723 and P714 pneumatic rotary or quarter-turn actuators used to open and close Fisher Internal Valves. Product Description All Fisher internal valves can be fitted with a rotary actuator that can be used to open and close the internal valves from a remote location. These rotary actuators attach directly to the valve after removal of the cable-operating lever. Included in each assembly is a lever adaptor and mounting hardware. Use of rotary actuators permits the opening and closing of the internal valve to be tied into the air brake of the transport or bobtail. Rotary actuators can also provide a convenient way to remotely operate a number of internal valves on stationary storage tanks at bulk plants. Principle of Operation A pneumatic supply air valve or switching valve installed at a desired location allows air pressure to be applied to the actuator. The pressure supply rotates the coupler (Figures 9 to 13) and the internal valve s operating lever, 2

Figure 3. Coupler Installation For Size 1-1/4-inch Rotary Actuator opening the valve. Upon release of supply pressure, the valve s operating lever returns to the closed position. Supply pressure sources may include dry/filtered air, nitrogen, carbon dioxide or propane vapor. Installation NoTICe Minimum air consumption and maximum internal valve life are obtained by using an actuator operating pressure as indicated in Table 1. a 67C Series regulator can be used to supply pressure to the actuator if desired.! WarNINg Identify the gland mounting hardware on your valve. Downstream pressure must be released before removing the screws holding the gland housing to the internal valve body. failure to do so could result in personal injury. Size 1-1/4-inch NPT rotary actuator Bracket Installation 1. Remove the (2) socket head cap screws from the valve gland. 2. Align the actuator bracket to the mounting holes. 3. Reinstall socket head cap screws and split lock washers to secure. Coupler Installation 4. Using the hand actuation lever, turn the internal valve stub clockwise by hand until the valve cam is touching the valve stem (see Figure 14). Figure 4. Air Fittings and Fusible Link Installation 5. Slide the rotary actuator coupling over the valve stub so that the holes of the valve stub shaft and the coupling are aligned. Press the supplied roll pin into the aligned through holes. 6. With the coupler and stub shaft pinned together and the valve cam touching the valve stem turn the coupling counter clockwise 1/8 of a turn, or until the flat of the coupling is square with the valve (see Figure 3). Actuator Installation 7. Place four actuator mounting studs through the bracket holes. 8. Install the four supplied split lock washers and nuts. Air Fittings and Fuse Plug Installation 9. Place the brass NPT Tee into the actuator inlet port, see Figure 4. 10. Install Fuse plug into unused port on brass NPT tee. Size 2 and 3-inch NPT rotary actuator Coupler Installation 1. Using the hand actuation lever, turn the internal valve stub clockwise by hand until the valve cam is touching the valve stem (see Figure 14). 2. Slide the rotary actuator coupling over the valve stub so that the holes of the valve stub and the coupling are aligned. Press the supplied roll pin into the aligned through holes. 3. With the coupler and stub pinned together and the valve cam touching the valve stem turn the coupling counter clockwise 1/8 of a turn, or until the flat of the coupling is square with the valve (see Figure 5). 3

Figure 5. Coupler Installation for Sizes 2 and 3-inch Rotary Actuator Bracket Installation NoTe for valves with the gland restrained with cap screws continue to step 4, for valves with easy mount studs skip to step 6. for Valves with Cap Screws 4. Remove the (3) cap screws and split lock washers from the valve gland. Align the actuator bracket to the mounting holes. 5. Reinstall cap screws and split lock washers. for Valves with easy Mount Studs 6. Align the actuator bracket to the gland studs. 7. Install lock washers and nuts on the two long studs. NoTe The short stud does not require an installed nut, see figure 6. Actuator Installation 8. Place four actuator mounting studs through the bracket holes. 9. Install the four supplied split lock washers and nuts. Air Fittings and Fuse Plug Installation 10. Place the brass NPT Tee into the actuator inlet port, see Figure 4. 11. Install Fuse Plug into unused port on brass NPT tee. Size 3-inch Single and Double flange rotary actuators Coupler Installation 1. Using the hand actuation lever, turn the internal valve stub clockwise by hand until the valve cam is touching the valve stem (see Figure 14). Figure 6. Bracket Installation for Valves with Short Stud 2. Slide the rotary actuator coupling over the valve stub so that the holes of the valve stub and the coupling are aligned. Press the supplied roll pin into the aligned through holes. 3. With the coupler and stub pinned together and the valve cam touching the valve stem turn the coupling counter clockwise 1/8 of a turn, or until the flat of the coupling is square with the valve (see Figure 7). Bracket Installation 4. Remove the (2) cap screws and split lock washers from the valve fl ange. Align the actuator bracket to the mounting holes. 5. Reinstall cap screws and split lock washers. Actuator Installation 6. Place four actuator mounting studs through the bracket holes. 7. Install the four supplied split lock washers and nuts. Install Air Fittings and Fuse Plug 8. Place the brass NPT Tee into the actuator inlet port, see Figure 4. 9. Install Fuse Plug into unused port on brass NPT tee. Size 4-inch Single flange rotary actuator Bracket Installation 1. Remove the (4) cap screws from the valve gland. Align the actuator bracket to the gland retaining fl ange and the mounting holes. 2. Reinstall cap screws and split lock washers. Confi rm washer is fl attened. Coupler Installation 3. Using the hand actuation lever, turn the internal valve stub clockwise by hand until the valve cam is touching the valve stem (see Figure 14). 4

Figure 7. Coupler Installation for Size 3-inch Single and Double Flange Rotary Actuators Figure 8. Coupler Installation for Size 4-inch NPT Single Flange Rotary Actuator 4. Slide the rotary actuator coupling over the valve stub so that the holes of the valve stub and the coupling are aligned. Press the supplied roll pin into the aligned through holes. 5. With the coupler and stub pinned together and the valve cam touching the valve stem turn the coupling counter clockwise 1/8 of a turn, or until the fl at of the coupling is square with the valve (see Figure 8). Actuator Installation 6. Place four actuator mounting studs through the bracket holes. 7. Install the four supplied split lock washers and nuts. Install Air Fittings and Fuse Plug 8. Place the brass NPT Tee into the actuator inlet port, see Figure 4. 9. Install Fuse Plug into unused port on brass NPT tee. The installation of fuse plugs in the actuator piping will allow the pneumatic pressure to vent, closing the valve if the plug is exposed to temperature above 208 to 220 F / 98 to 104 C. After installing the unit, operate the actuator with pressure to see that it smoothly opens and closes the internal valve without sticking or jamming. Maintenance regulator Technologies recommends these steps be conducted once a month: 1. Regularly inspect the coupling to see that it operates freely and that there is no leakage around the stub shaft. If there is leakage or sticking, the packing should be replaced. 2. Check for tight closure of the Internal Valve seat discs regularly. Any leakage indicates damage to the seat caused from wear or from dirt or scale lodging and embedding in the seat. To check for leakage, close the internal valve and exhaust downstream pressure. Close the first valve downstream from the internal valve, and note any pressure build-up by means of a pressure gauge. If leakage is indicated, the seat discs should be replaced. Parts ordering When corresponding about this equipment, always reference the equipment type number found on the nameplate. When ordering replacement parts reference the complete 11-character part number of each part. 5

1/4-20 X 0.62 BOLT (2) ROTARY ACTUATOR 1/4 WASHER (2) ERAA05038 1/4 NUT (4) Figure 9. Type P713 for Type C484-24 Internal Valves (Single Flange) 5/16 WASHER (2) 5/16-24 X 0.75 BOLT (2) ROTARY ACTUATOR 1/4 NUT (4) ERAA05041 Figure 10. Type P723 for Type C484-24 Internal Valves (Double Flange) 1/4 NUT (4) ROTARY ACTUATOR ERAA05035 Figure 11. Type P731 for Type C483-24 Internal Valves 6

1/4 NUT (4) ROTARY ACTUATOR ERAA04775 Figure 12. Type P739 for Types C407, C471 and C477 (2 and 3-inch NPT) Internal Valves ROTARY ACTUATOR 1/4 NUT (4) 3/8-16 UNC X 1 BOLT (4) 3/8 WASHER (4) ERAA05047 Figure 13. Type P714 for Type C404-32 Internal Valves 7

CAM CAM Location of cam when in contact with stem Location of cam when actuator is installed Figure 14. Cam Location Parts List Description Actuator Kit Type P731 Type P739 Type P713 Type P723 Type P714 Part Number ERAA04251A0 ERAA04252A0 ERAA04254A0 ERAA04255A0 ERAA04262A0 LP-Gas Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 2013, 2014; All Rights Reserved