Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions
|
|
- Elisabeth Lloyd
- 7 years ago
- Views:
Transcription
1 DVC6200 Digital Valve Controller Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions Digital Valve Controller Configuration (1) Mounting Figure Page DVC6200 DVC6200 SIS DVC6200f DVC6200p Integral mounting to the Fisher GX control valve and actuator system Integral mounting to Fisher rotary actuators Sliding-stem linear applications Quarter-turn rotary applications Product Bulletin With integrally mounted filter regulator 1 1, 2 DVC6205 DVC6205 SIS DVC6205f Remote mount base unit 2 3 DVC6205p DVC6215 Feedback unit DVC6200 digital valve controllers can also be mounted on other actuators that comply with IEC , IEC , VDI/VDE 3845 and NAMUR mounting standards. Magnet Assembly (1) Figure Page SStem #19 19 / 3/4 inch 4 4 SStem #25 25 / 1 inch 5 4 SStem #38 38 / 1-1/2 inch 6 5 SStem #50 50 / 2 inch 7 5 SStem # inch 8 6 SStem # / 8-1/4 inch 9 6 RShaft #1 / LRC (2) Fisher 2052 Size 1 & 3, 1051/1052 Size 40-70, 1061 Size , Sliding Stem > 210 (8.25 inches) 10 7 RShaft #2 / LRC (2) 2052 Size 1, 1051/1052 Size RShaft End 90 degree Linear magnet assembly width dimensions are shown in figure Linear Roller Cam. Figure 1. FIELDVUE DVC6200, DVC6200 SIS, DVC6200f, and DVC6200p Digital Valve Controller with Integrally Mounted Filter Regulator 54.9 (2.16) (11.75) (5.83) 61.1 (2.4) 59.4 (2.34) 1/4- NPT OUTPUT CONN A FISHER 67CFR 1/4- NPT SUPPLY CONN 1/2-14 NPT CONDUIT CONN BOTH SIDES 3/8- NPT VENT CONN 1/4- NPT OUTPUT CONN B (8.00)
2 Product Bulletin DVC6200 Digital Valve Controller Figure 1. FIELDVUE DVC6200, DVC6200 SIS, DVC6200f, and DVC6200p Digital Valve Controller with Integrally Mounted Filter Regulator (continued) 57.7 (2.27) (4.05) (5.73) 4.4 (7.26) 12.9 (0.51) 17.7 (0.70) M8 X H M6 X 1-6H (1.39) 34.6 (1.36) 57 (2.24) 35.3 (1.38) 35.4 (1.39) 35 (1.38) 92.4 (3.64) 32.3 (1.27) GE42896 BACK VIEW (REGULATOR NOT SHOWN) 1 Housing insert for SSTEM #210 magnet assembly (figure 9) inserted here. 2
3 DVC6200 Digital Valve Controller Product Bulletin Figure 2. FIELDVUE DVC6205, DVC6205 SIS, DVC6205f, and DVC6205p Remote Mount Base Unit Envelope Dimensions 56.6 (2.23) 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 1/4- NPT OUTPUT CONNECTION A 59.2 (2.33) (8.26) 132 (5.20) 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 233 (9.17) (5.83) (6.33) 1/4- NPT OUTPUT CONNECTION B 79.6 (3.13) (4.88) GE
4 Product Bulletin DVC6200 Digital Valve Controller Figure 3. FIELDVUE DVC6215 Feedback Unit Envelope Dimensions (4.53) 1/4- NPT AIR PASSAGE (4.16) 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES (5.92) GE53725 Mounting hole locations for the DVC6215 feedback unit are the same as for the DVC6200, DVC6200 SIS, DVC6200f, and DVC6200p digital valve controller. Refer to the back view in figure 1. Magnet Assemblies Figure 4. SStem #19 Magnet Assembly (Also see 2 in figure 6) Figure 5. SStem #25 Magnet Assembly (Also see 2 in figure 6) (2.40) (2.40) 31.2 (1.23) (0.63) 31.2 (1.23) 15.9 (0.62) 32 (1.26) 5.5 (0.22) 32 (1.26) 5.5 (0.22) 8-19 ( INCH) TRAVEL RANGE ( INCH) TRAVEL RANGE 4
5 DVC6200 Digital Valve Controller Product Bulletin Figure 6. SStem #38 Magnet Assembly (2.90) 6.3 (0.25) (1.23) 15.9 (0.62) 5.5 (0.22) 32 (1.26) 6.3 (0.25) ( INCH) TRAVEL RANGE Figure 7. SStem #50 Magnet Assembly (Also see 2 in figure 6) (3.40) 28.5 (1.12) 10 (0.39).7 (0.74) 31.8 (1.25) 57.4 (2.26) ( INCH) TRAVEL RANGE 5
6 Product Bulletin DVC6200 Digital Valve Controller Figure 8. SStem #100 Magnet Assembly (Also see 2 in figure 6) 137. (5.40) 28.5 (1.12) 10 (0.39).7 (0.74) 31.8 (1.25) (4.26) ( INCH) TRAVEL RANGE Figure 9. SStem #210 Magnet Assembly (Also see 2 in figure 6) (10.31).7 (0.74) 28.5 (1.12) 58 (2.28) 71.7 (2.82) ( INCH) TRAVEL RANGE 5.5 (0.22) (0.47) 2.5 (0.10) HOUSING INSERT FOR SSTEM #210 MAGNET ASSEMBLY 1 1 Refer to back view of figure 1 for housing insert placement. 6
7 DVC6200 Digital Valve Controller Product Bulletin Figure 10. RShaft Window Magnet Assemblies (4.51) 95.3 (3.75) (6.88) 194 (7.64) 57 (2.24) 33.3 (1.31) 5.3 (0.21) 74 (2.91) 109 (4.29) 5 X 9 (0.35) THRU 4 X 9.7 (0.38) THRU BRACKET SPRING, BIAS BRACKET SPRING, BIAS 29.5 (1.16) 39.7 (1.56) 54.9 (2.16) RSHAFT WINDOW # (1.16) 39.7 (1.56) 49.2 (1.94) RSHAFT WINDOW #2 7
8 Product Bulletin DVC6200 Digital Valve Controller Figure 11. RShaft End Mount Magnet Assembly 4 X 3.4 (0.13) THRU 22 (0.87) 8.2 (0.32) 28 (1.10) Related Documents Bulletin 62.1:DVC6200 DVC6200 Digital Valve Controller (D103415X012) Bulletin 62.1:DVC6200 SIS DVC6200 SIS Digital Valve Controller (D103555X012) Bulletin 62.1:DVC6200f DVC6200f Digital Valve Controller (D103399X012) Bulletin 62.1:DVC6200p DVC6200p Digital Valve Controller (D103564X012) All documents are available from your Emerson Process Management sales office. Also visit our website at (1.45) 7.2 (0.28) Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa USA Sorocaba, 087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore Singapore , 2014 Fisher Controls International LLC. All rights reserved.
Fisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
More informationFisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM
Instruction Manual Supplement Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM Contents Related Documents...
More information4310/4320 Wireless Position Monitor
Quick Start Guide Wireless Position Monitor 4310/4320 Wireless Position Monitor This document is intended to guide you through initial set up of the 4310/4320 wireless position monitor. Steps include:
More informationBaumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
More informationBaumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
More informationBaumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
More informationBaumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
More informationM Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves
M Series Actuators D500239X0 Product Bulletin M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves M Series handwheel gear actuators are totally enclosed, weatherproof, worm gear actuators
More informationValveLink Mobile Software
Quick Start Guide ValveLink Mobile Software Version 4.0 ValveLink Mobile Software ValveLink Mobile software lets you configure, calibrate, and troubleshoot FIELDVUE DVC2000, DVC6000, DVC6000f, DVC6200,
More informationFisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability
Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability 2 Improving Safety Instrumented System Reliability Improving Safety Instrumented System Reliability 3 Safety Instrumented
More informationValveLink Software Quick Start Guide
Quick Start Guide D102813X012 October 2010 ValveLink Software Quick Start Guide ValveLink Solo AMS ValveLink SNAP-ON ValveLink DTM ValveLink PLUG-IN for PRM Refer to the ValveLink Software Installation
More informationFisher 657 and 667 Diaphragm Actuators
657 and Actuators Product Bulletin Fisher 657 and Diaphragm Actuators Fisher 657 and spring-opposed diaphragm actuators position the valve plug in the valve in response to varying controller or valve positioner
More informationFisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)
Sliding-Stem Live-Loaded Packing Product Bulletin Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded) Fisher ENVIRO-SEAL and HIGH-SEAL live-loaded packing systems offer
More informationFisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)
DVC6200 SIS Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS) The FIELDVUE DVC6200 SIS digital valve controller is a HART
More informationENVIRO-SEAL. Valve Packing Systems Extending service life. Meeting environmental requirements.
Valve Packing Systems Extending service life. Meeting environmental requirements. 2 Valve Packing Systems valve packing systems: Designed specifically to reduce your total cost of ownership for non-environmental
More informationFisher 4320 Wireless Position Monitor, with On/Off Control Option
Product Bulletin Fisher Wireless Position Monitor, with On/Off Control Option The Fisher eliminates the need for wiring to an on/off pneumatically actuated valve. It provides a precise wireless feedback
More informationFisher GX Control Valves
Fisher GX Control Valves Fisher GX Control Valves Innovation. Technology. Reliability. Emerson engineers started with a clean slate in developing Fisher GX control valves. Their goal was to bring unmatched
More informationFisher 2625, 2625SST, and 2625NS Volume Boosters
Instruction Manual 2625, 2625SST, and 2625NS Volume Booster Fisher 2625, 2625SST, and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational
More informationFisher FIELDVUE DVC6200f Digital Valve Controller for FOUNDATION fieldbus
Instruction Manual DVC62f Digital Valve Controller Fisher FIELDVUE DVC62f Digital Valve Controller for FOUNDATION fieldbus This manual applies to: Device Type 462 Device Revision 2 Hardware Revision 8
More informationSafety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator
Instruction Manual Supplement ED, ES, ET, EZ, HP, HPA Valves with 657/667 Actuator Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator Purpose This safety manual provides information
More informationFisher FIELDVUE DVC2000 Digital Valve
DVC2000 Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller is simple to use, compact, and designed for easy mounting.
More informationFisher FIELDVUE DVC6200 Digital Valve
Instruction Manual DVC6200 Digital Valve Controller Fisher FIELDVUE DVC6200 Digital Valve Controller This manual applies to Instrument Level HC, AD, PD, ODV AC Device Type 03 07 Device Revision 2 2 Hardware
More information4310/4320 Wireless Position Monitor Burst Configuration and Diagnostics
Instruction Manual Supplement 4310/4320 Wireless Position Monitor 4310/4320 Wireless Position Monitor Burst Configuration and Diagnostics This document applies to: Fisher 4320 Device Type 1308 (hex) 4872
More informationFisher CV500 Rotary Globe Control Valve
CV500 Valve D101606012 Product Bulletin Fisher CV500 Rotary Globe Control Valve The Fisher CV500 Cam Vee-Ball control valve combines the rangeability of the cammed-segmented V-notched ball, with the inherent
More informationSIS. Fisher FIELDVUE DVC6200 Series Digital Valve Controllers. Contents. Before You Begin... 2
Quick Start Guide DVC6200 Digital Valve Controllers Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Contents Before You Begin... 2 Step 1. Install the DVC6200 on the Valve... 3 Step 2. Connect
More informationBaumann 24000SB Barstock Control Valve
Instruction Manual 24000SB Valve Baumann 24000SB Barstock Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Disassembly...
More informationFisher D3 Control Valve
D3 Valve Product Bulletin Fisher D3 Control Valve The Fisher D3 control valve is a compact, rugged valve designed for on/off or throttling control, and utilizes FloPro technology, using either pneumatic
More informationUncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves
Baumann TM Sanitary and Aseptic Process Valves The Company Fisher Controls International LLC, Baumann Control Valves, is an ISO 9001 certified, PED compliant manufacturer of general utility, precision
More informationSimulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals
Instruction Manual Supplement 249 Sensors Simulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals Displacer / torque tube
More informationFisher 8580 Rotary Valve
8580 Valve Product Bulletin Fisher 8580 Rotary Valve The Fisher 8580 rotary valve offers excellent throttling and automated on-off, quarter-turn performance. An approximately linear flow characteristic
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationFIELDVUE. DVC6200 Series Digital Valve Controller A Single Instrument Solution Across Your Facility
FIELDVUE DVC6200 Series Digital Valve Controller A Single Instrument Solution Across Your Facility 2 A Single Instrument Solution What if you had a single instrument solution that could... Meet your control
More information167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
More informationFisher 377 Trip Valve
Instruction Manual Fisher 377 Trip Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Supply Pressure Requirements...
More informationBasic Fundamentals Of Safety Instrumented Systems
September 2005 DVC6000 SIS Training Course 1 Basic Fundamentals Of Safety Instrumented Systems Overview Definitions of basic terms Basics of safety and layers of protection Basics of Safety Instrumented
More informationFisher 249 Caged Displacer Sensors
Instruction Manual 249 Caged Sensors Fisher 249 Caged Displacer Sensors Contents Introduction... 1 Scope of Manual... 1... 2 Type Number... 3 Educational Services... 4 Maintenance... 4 Cleaning the Cage...
More informationAMS ValveLink SNAP-ON Application
AMS Suite: Intelligent Device Manager Product Data Sheet AMS ValveLink SNAP-ON Application Communicate with both HART and Foundation fieldbus FIELDVUE digital valve controllers in the same application.
More informationFisher GX 3-Way Control Valve and Actuator System
GX 3-Way Valve and Actuator Product Bulletin Fisher GX 3-Way Control Valve and Actuator System The Fisher GX 3-Way is a compact, state-of-the-art control valve and actuator system, designed to accurately
More information289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
More informationFisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter
3710 and 3720 Positioners Product Bulletin Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter Fisher 3710 pneumatic and 3720 electro-pneumatic positioners are designed for use with either
More informationFisher Vee-Ball Rotary Control Valves Highly efficient rotary valves to meet a variety of applications
Fisher Vee-Ball Rotary Control Valves Highly efficient rotary valves to meet a variety of applications Fisher Vee-Ball Rotary Control Valve Emerson wants to be your partner. With Emerson, you ll have the
More informationFisher 846 Electro-Pneumatic Transducer
846 Transducer Product Bulletin Fisher 846 Electro-Pneumatic Transducer The Fisher 846 electro-pneumatic transducer is a rugged, field-mountable transducer that accepts an electrical input signal and converts
More informationDamcos. LPU-D for double-acting actuator. Product Data Sheet November 2014 SD 1502-2E06
Damcos LPU-D for double-acting actuator Product Data Sheet November 2014 SD 1502-2E06 TM Damcos LPU-D November 2014 LPU-D The LPU-D is designed for the control of double-acting actuators requiring hydraulic
More informationValveLink DTM ValveLink PLUG IN for PRM
ValveLink Software Product Bulletin ValveLink Software ValveLink Solo AMS ValveLink SNAP ON ValveLink DTM ValveLink PLUG IN for PRM Communicate with both HART and FOUNDATION fieldbus FIELDVUE digital valve
More informationFisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations
Instruction Manual 1061 F & G Actuator Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationSLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM
SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.
More informationType 119 Control Valve
Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information
More informationFisher V500 Rotary Globe Control Valve
V500 Valve D100054012 Product Bulletin Fisher V500 Rotary Globe Control Valve The Fisher V500 eccentric plug rotary control valve controls erosive, coking, and other hard-to-handle fluids, providing either
More information1301 Series High-Pressure Regulators
1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk
More informationWorcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
More informationHazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
More informationBristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters
July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson
More informationRosemount 1199 Submersible Seal
Product Data Sheet January 2015 00813-0400-4016, Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and
More informationRosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
More informationSmart Wireless Solutions. Intelligent Well Production Starts Here
Smart Wireless Solutions Intelligent Well Production Starts Here Enable the intelligent field Apply Smart Wireless from wellhead to the operations center Automate Hundreds of Wells or a Few Emerson s
More informationSupportNet Technical Services
TM SupportNet Technical Services Help is Just a Mouse Click Away Introducing SupportNet Technical Services Now you can get technical support for your ROC, FloBoss, Bristol, and ControlWave brand products
More informationFull-time Career Opportunities Launch Your Career with Emerson
Full-time Career Opportunities Launch Your Career with Emerson CONTENTS CONTROLS ENGINEER 3 ELECTRO-MECHANICAL TECHNICIAN 4 ELECTRONICS DESIGN ENGINEER 5 FIRMWARE DESIGN ENGINEER 6 MECHANICAL DESIGN ENGINEER
More informationFisher FIELDVUE DVC6200f Digital Valve Controller for FOUNDATION fieldbus
Instruction Manual DVC62f Digital Valve Controller Fisher FIELDVUE DVC62f Digital Valve Controller for FOUNDATION fieldbus This manual applies to: Device Type 462 Device Revision 2 Hardware Revision 8
More informationFisher 646 Electro Pneumatic Transducer
Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...
More informationTorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
More informationModel 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
More informationRosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level
Solutions for the Process Industries Rosemount Analytical s -STREAM E Web-Browser Interface Takes Process Analysis to the Next Level The -Stream E takes process gas analysis to the level of ease of use
More informationFisher FIELDVUE DVC6200 Digital Valve
Instruction Manual DVC6200 Digital Valve Controller Fisher FIELDVUE DVC6200 Digital Valve Controller This manual applies to Instrument Level HC, AD, PD, ODV Device Type 09 Device Revision 1 & 2 Hardware
More informationTypes 66R and 66RR Low-Pressure Relief Valves
November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling
More informationG-Series Pneumatic and Hydraulic Actuators. Next Generation Valve Automation Solutions
G-Series and Hydraulic Actuators Next Generation Valve Automation Solutions Design and Construction Bettis G-Series with Wireless Transmitter Emerson Process Management sets the standards for innovation
More informationFisherr 8510 and 8510B Eccentric Disc Control Valves (EMA)
8510/8510B Valve Product Bulletin Fisherr 8510 and 8510B Eccentric Disc Control Valves (EMA) Fisher 8510 and 8510B eccentric disc valves feature an eccentrically mounted disc and a PTFE or 316 stainless
More informationFisher 3582 and 3582i Positioners and 582i Electro-Pneumatic Converter
3582 and 3582i Positioners Product Bulletin Fisher 3582 and 3582i Positioners and 582i Electro-Pneumatic Converter Fisher 3582 pneumatic valve positioners and 3582i electro-pneumatic valve positioners,
More informationAMS Suite: Intelligent Device Manager: An Automated Instrument Calibration System
June 2007 AMS Suite: Intelligent Device Manager: An Automated Instrument Calibration System This paper describes advanced asset optimization software interfaces with selfdocumenting calibrators, making
More informationAMS Suite: Intelligent Device Manager
Product Data Sheet AMS Suite: Intelligent Device Manager with the DeltaV System Predict necessary maintenance activities instead of reacting to problems that are already impacting your process. Manage
More informationTECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12
TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem
More informationFisher A11 High-Performance Butterfly Valve
A11 Valve Product Bulletin isher A11 igh-performance Butterfly Valve The isher A11 igh-performance Butterfly Valve maintains tight shutoff, and can be specified for a wide range of pressure and temperature
More informationValv-Powr Series VPVL Stainless Steel Model D Double-Acting and Spring-Return Rack-and-Pinion Compact Pneumatic Actuators
Valv-Powr Series VPVL Stainless Steel Model D Double-Acting and Spring-Return Rack-and-Pinion Compact Pneumatic Actuators Valv-Powr VPVL double-opposed piston actuators combine the benefits of high cycle
More informationAMS Suite: Intelligent Device Manager with the DeltaV system
with the DeltaV TM system AMS Suite: Intelligent Device Manager with the DeltaV system Manage your HART, FOUNDATION fieldbus, WirelessHART, and Profibus DP devices using a single, integrated application
More informationDeltaV System Health Monitoring Networking and Security
DeltaV Distributed Control System White Paper DeltaV System Health Monitoring Networking and Security Introduction Emerson Process Management s DeltaV System Health Monitoring service enables you to proactively
More informationFisher C1 Pneumatic Controllers and Transmitters
C1 Controllers and Transmitters Product Bulletin Fisher C1 Pneumatic Controllers and Transmitters Fisher C1 controllers and transmitters continue the tradition of durable and dependable Fisher pressure
More informationColocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
More informationROC800-Series Advanced Pulse Module
ROC800:APM Product Data Sheet D301231X012 May 2014 ROC800-Series Advanced Pulse Module The Advanced Pulse Module (APM) for the ROC800-Series Remote Operations Controller (ROC800) provides advanced functionality
More informationGeneral Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
More informationAAT001-10E TMR Angle Sensor
Data Sheet AAT001-10E TMR Angle Sensor Key Features Tunneling Magnetoresistance (TMR) Technology Very High Output Signal Without Amplification Wide Airgap Tolerance Very High Resistance for Extremely Low
More informationIntegrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
More information4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
More informationFisher GX Control Valve and Actuator System
GX Control Valve and Actuator Product Bulletin Fisher GX Control Valve and Actuator System The Fisher GX is a compact, state-of-the-art control valve and actuator system, designed to control a wide range
More informationOpenEnterprise. Lifecycle Services
TM OpenEnterprise Lifecycle Services Emerson offers a comprehensive Lifecycle Services approach to help our customers achieve maximum business value and operational excellence Lifecycle Services are Emerson
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationType 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
More informationHARDWARE SOFTWARE BRAINWARE
Discover Aperio HARDWARE SOFTWARE BRAINWARE Emerson s Aperio system is developed to integrate control and monitoring functions on any type of ship and application, e.g. engines, generators, switchboards
More informationFisher 846 Current-to-Pressure Transducer
Instruction Manual 846 Transducer Fisher 846 Current-to-Pressure Transducer Contents 1. Introduction Scope of Manual... 2 Description... 2 Specifications... 2 Related Documents... 5 Educational Services...
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationThis document has been provided by the International Center for Not-for-Profit Law (ICNL).
This document has been provided by the International Center for Not-for-Profit Law (ICNL). ICNL is the leading source for information on the legal environment for civil society and public participation.
More informationInstallation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
More informationFisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter
360J and 3620J Positioners Product ulletin Fisher 360J and 3620J Positioners and 3622 Electro-Pneumatic Converter Fisher 360J or 360JP pneumatic and 3620J or 3620JP electro-pneumatic positioners are used
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationJAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES
JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES The new improved Quartz is available in explosion/flame proof (QX), intrinsically safe and nonincendive (QN) and general purpose (QG)
More informationType 99 Pressure Reducing Regulator
Bulletin 7: February 2016 Type Pressure Reducing Regulator W27 W76 Figure 1. Typical Type Regulator Introduction The Type gas regulators provide a broad capacity for controlled pressure ranges and capacities
More informationSAGEON SITE MONITOR (SSM) Application Note AN103-4012-00
SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00 AN 103-4012-00, Issue 2a sageon_sm-an.pdf www.unipowerco.com SALES: +1-800-440-3504 HEAD OFFICE: +1-954-346-2442 EUROPE: +44 (0)1903 768200 SAGEON
More informationFIELDPOINT BUS EXTENDER CABLE
INSTALLATION GUIDE FIELDPOINT BUS EXTENDER CABLE If you have space constraints, you can use the FieldPoint Bus Extender Cable to mount a FieldPoint bank in two or three rows. Caution You should not use
More informationFisher HP Series Control Valves
HP Valve Product Bulletin Fisher HP Series Control Valves HP (Globe Valve) HPA (Angle Valve) Balanced High-Temperature Trim Balanced Tight Shutoff Trim Unbalanced Trim Fisher HP Series control valves are
More informationHazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
More informationRGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
More information