P600 Series Pneumatic Actuators

Similar documents
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

1805 Series Relief Valves

DYNA RIDER FOOTBOARD KIT

167D Series Switching Valves

MP8000 Series Pneumatic Valve Actuators

Fisher 377 Trip Valve

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Type 119 Control Valve

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Fisher 249 Caged Displacer Sensors

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

289 Series Spring-Loaded Relief Valves

Easy Tool Retracting System CMC-SR2159ER36

TITAN 13 x 2 ½ BRAKES

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

Stainless Steel Single and Dual Circulation Kits

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

POWERS Controls No. 4 Pneumatic Damper Actuator

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Baumann Flexsleev Sanitary Control Valve

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

DiscPlus DX195 and DX225 Air Disc Brakes

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Fisher 377 Trip Valve

TYPE E Main Valve Sizes 3 /8 through 12

67C Series Instrument Supply Regulators

Float and Thermostatic Traps Series H, C and X

CHROME FRONT BRAKE MASTER CYLINDER KIT

HYDRAULIC LIFT TABLE CART 2200-LB.

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

PRESSURE REDUCING CONTROL VALVE

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

Baumann Little Scotty Bronze Control Valve

1301 Series High-Pressure Regulators

1000-LB. TRAILER JACK OWNER S MANUAL

Types 66R and 66RR Low-Pressure Relief Valves

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

1/29/2008 DR50. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Model 43AP Pneumatic Controller, Style B

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

WE-350 Series ¼ Turn Electric Actuator

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Baumann Mikroseal Control Valve

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

TECHNICAL DATA. Dry 122a. November 12, 2013

HYDRAULIC TABLE CART 500-LB.

TABLE OF CONTENTS. Section 1 - Assembling your new pit bike.

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

DR50 Hensim Dirt Runner 49cc Dirt Bike (VIN PREFIX LLCH or LUAH)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

DR90. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51

DR90. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51

Fuel Injection Pump, Rotary ( )

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Installation, Operation and Maintenance Manual for Pilot Operated Valves

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Baumann Way Bronze or Stainless Steel Control Valve

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

758 Heavy-duty Ratchet Guy Wire Cutter

Baumann 24000SB Barstock Control Valve

TOOL SCHEMATIC AND PARTS MODEL 3150/38 W16R STAPLER

STEERING SYSTEM - POWER

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

TECHNICAL SERVICE MANUAL

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

IOM SERIES 820-E/P Electro-Pneumatic Positioner

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Fisher CV500 Rotary Globe Control Valve

Spicer Axles & Brakes ABIB-0302

60 Series Pilot Regulator

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Toroidal Conductivity Sensor

Unique DV-ST UltraPure - Manuel: for valve sizes DN8 to DN80 (¼ to 3 )

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

SELECTION, APPLICATION & MAINTENANCE

Flat Bottom Long Ram Hydraulic Jack

NITROUS TRANSFER PUMP INSTRUCTIONS

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Transcription:

Instruction Manual MCK-2159 P600 Series August 2013 P600 Series Pneumatic Actuators P1131 P1132 TYPE P613 TYPE P623 P1135 P1134 TYPE P614A TYPE P639A Figure 1. P600 Series Pneumatic Actuators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher equipment must be installed, operated, and maintained in accordance with federal, state, and local codes and Emerson Process Management Regulator Technologies, Inc. (Regulator Technologies) instructions. The installation in most states must also comply with NFPA No. 58, ANSI K61.1, and DOT standards. Only personnel trained in the proper procedures, codes, standards, and regulations of the LP-Gas or Anhydrous Ammonia (NH 3 ) industries should install and service this equipment. Warranty Note The use of non-fisher actuators will void internal valve warranty and may result in leakage of the gland packing caused by premature wear. In addition to premature wear, the use of non- Fisher actuators may result in lower than expected flow rates and possible leakage across the valve seats. D450162T012 www.fisherregulators.com

Specifications Available Configuration See Figure 2 Pressure Source Air or Nitrogen Types P613, P623, and P639A Actuator Pressure Limits Minimum: 20 psig / 1.4 bar Maximum: 125 psig / 8.6 bar Type P614A Pressure Limits Minimum: 40 psig / 2.8 bar Maximum: 125 psig / 8.6 bar Temperature Capabilities -20 to 150 F / -29 to 66 C Return Mechanism Spring only no air Thermal Release 1/4 NPT fuse plug installed in center port of actuator housing Thermal Release Melt Point 212 F / 100 C Approximate Weight 5.6 pounds / 2.6 kg P - 6 3 9 CODE DESCRIPTION 3 3-inch Valve 4A 9A 4-inch Valve Multiple Sizes 1 Single Flange 2 Double Flange 3 NPT 6 Internal Valves Actuator Figure 2. P600 Series Product Numbering Introduction Scope of the Manual This manual covers instructions for the Types P613, P614A, P623, and P639A pneumatic actuators used to open and close Fisher Internal Valves. Product Description All Fisher, 3 and 4-inch internal valves can be fitted with a pneumatic actuator that can be used to open and close the internal valves at the valve or from a remote location. These pneumatic actuators attach directly to the valve after removal of the cableoperating lever. Included in each assembly is an operating lever and mounting hardware. Use of pneumatic actuators permits the opening and closing of the internal valve to be tied into the air brake of the transport or bobtail. Pneumatic Actuators can also provide a convenient way to remotely operate a number of internal valves on stationary storage tanks at bulk plants. Principle of Operation A pneumatic supply air valve or switching valve installed at a desired location allows air pressure to be applied to the actuator. The pressure supply moves the clevis (key 8B, Figures 4 to 7) and the internal valve s operating lever (key 5, Figures 4 to 7), opening the valve. Upon loss of air pressure, the valve s operating lever immediately returns to the closed position. Pneumatic supply pressure sources include dry/filtered air, nitrogen or carbon dioxide. Before beginning, refer to Figure 8 for proper cam orientation. Installation CAUTION Minimum air consumption and maximum internal valve life are obtained by using an actuator operating pressure as indicated in Table 1. A 67C Series 2

Table 1. Pneumatic Actuators Information INTERNAL VALVE TYPE NUMBER PNEUMATIC ACTUATOR TYPE NUMBER RECOMMENDED OPERATING PRESSURE RANGE C484-24 Jet Bleed Internal Valve C404-24 Internal Valve C483-24 Jet Bleed Internal Valve C403-24 Internal Valve C471 and C477 Jet Bleed Internal Valve C421 and C427 Internal Valve P613 P623 P639A 20 to 40 psig / 1.4 to 2.8 bar 20 to 40 psig / 1.4 to 2.8 bar 20 to 40 psig / 1.4 to 2.8 bar C404-32 Internal Valve P614A 40 to 60 psig / 2.8 to 4.2 bar Regulator can be used to supply pressure to the actuator if desired. To install an actuator kit, first remove any existing operating lever from the internal valve shaft. When installing the type: Type P623 Mount the bracket (key 1) to the flanges with 2 bolts (key 2) and 2 lock washers (key 12) using 96 to 120 inch-pounds / 10.85 to 13.56 N m torque as shown in Figure 5, fitting the operating lever (key 5) on the internal valve shaft. Type P613 Mount the bracket (key 1) to the flanges with 2 bolts (key 2) and 2 lock washers (key 14) using 96 to 120 inch-pounds / 10.85 to 13.56 N m torque as shown in Figure 4, fitting the operating lever (key 5) on the internal valve shaft.! WARNING Downstream pressure in the internal valve must be released before mounting the P614A bracket. Failure to do so could result in personal injury. Type P614A There must be no downstream pressure in the internal valve. Mount the bracket (key 1) to the flanges with 4 bolts (key 4) and lockwashers (key 14) using 120 to 180 inch-pounds / 13.56 to 20.34 N m torque as shown in Figure 7, fitting the operating lever (key 5) on the internal valve shaft. CAUTION For valves using the three-hole gland assembly, it is important to identify the hardware design that secures the gland to the body. For Screw-Type design using keys 2 and 12, proceed with instructions below in section labeled Screw-Type Mounting Hardware. For the Stud-Type design using keys 12, 19, and 21, as shown in Figure 6 skip to Hardware section. All keys are referenced in Figure 6.! WARNING Screw-Type Hardware: Downstream Pressure must be released before removing the screws holding the gland assembly to the internal valve body. Failure to do so could result in personal injury. Type P639A with Screw-Type Hardware There must be no downstream pressure in the internal valve. Install new stud-mounted hardware Position the lever (key 5) with Side B facing away from the bracket. Insert the clevis pin (key ) through the clevis (key 8B) and the lever and secure with the small cotter pin (key 8D). Remove the three cap screws holding the gland housing to the internal valve body and discard them. Install the provided long studs (key 20) in the topmost hole locations, and the short stud (key 21) in the bottom-most 6 o clock location. Secure the gland to the body with the first set of washers (key 12) and nuts (key 19). Mount the actuator bracket (key 1) as shown in Figure 6 and secure using the second set of washers (key 12) and nuts (key 19) supplied with this unit. Fit the operating lever on the internal valve shaft as the bracket is moved into place. Type P639A with Stud-Type Hardware A Type P639A Actuator can be installed on a valve equipped with Stud-Type hardware without removing downstream pressure from the piping system. First, position the lever (key 5) with Side B facing outwards, away from the bracket. Insert the clevis pin (key ) through the 3

clevis (key 8B) and the lever and secure with the small cotter pin (key 8D). Remove the protective caps from the studs, exposing the threads. Fit the operating lever on the internal valve shaft as the bracket is moved into place. Mount the actuator bracket (key 1) as shown in Figure 6, securing the bracket to the two long studs (key 20) with the two nuts (key 19) and washers (key 12) supplied with the unit. P623 MM-YY Using existing capscrews Position the lever (key 5) with Side A facing away from the bracket. Insert the clevis pin (key ) through the clevis (key 8B) and the lever and secure with the small cotter pin (key 8D). Remove the three cap screws (key 3) holding the gland housing to the internal valve body and mount the actuator bracket (key 1) as shown in Figure 6 and secure using the same three cap screws. Fit the operating lever on the internal valve shaft as the bracket is moved into place. For All Models: 1. Install the cotter pin (key 6) through the operating lever and the internal valve shaft. The clevis (key 8B) is factory installed at 0.79 inch / 20 mm from the face of the brake chamber for optimal operation and should not need additional adjustments. If the internal valve does not close, then adjust the clevis position as follows. 2. Loosen the clevis hex nut (key 8E), the cotter pin (key 8D) and clevis pin (key ) to adjust the clevis (key 8B). 3. Establish the clevis position by moving the lever (key 5) so that the cam inside the internal valve is touching the stem (see Figure 8). 4. Rotate the lever back 1/8 inch / 3.2 mm which moves the cam away from the follower (See Figure 8). 5. Adjust the clevis (key 8B) to fit the lever position in step 4. 6. Tighten the clevis hex nut (key 8E). Attach the clevis pin into the lever and clevis. Install the cotter pin on to the clevis pin. The actuator has two 1/4-inch NPT supply ports. A thermal fuse plug is installed in the center port. Install the supply pressure tubing in the other port. If the center port is to be used for the supply pressure, remove the fuse plug and put it into the other opening. The installation of fuse plugs (key 9) in the actuator piping at the valve will allow the pneumatic pressure to vent, closing the valve if the plug is exposed to temperature above 208 to 220 F / 98 to 104 C. Before proceeding, make sure that the downstream system is prepared for product. After installing the unit, operate the actuator with pressure to see that it smoothly opens and closes the internal valve without sticking or jamming. If not, check the cotter pin and the lever to see if its binding with the bracket or binding on each other. Maintenance Figure 3. Actuator Date Code A simple preventive maintenance program for the valve and its controls will reduce potential problems. Regulator Technologies recommends these steps be conducted once a month: 1. Regularly inspect the operating lever to see that it operates freely and that there is no leakage around the stub shaft. If there is leakage or sticking, the packing should be replaced. 2. Check for tight closure of the Internal Valve seat discs regularly. Any leakage indicates damage to the seat caused from wear or from dirt or scale lodging and embedding in the seat. To check for leakage, close the internal valve and exhaust downstream pressure. Close the first valve downstream from the internal valve, and note any pressure build-up by means of a pressure gauge. If leakage is indicated, the seat discs should be replaced. 3. Because the actuator has a diaphragm seal, internal lubrication is not required. Periodic lubrication of the operating lever/actuator rod pivot is recommended. 4. All operating controls should be regularly inspected, cleaned and oiled. Periodic lubrication of the operating lever/clevis pivot is recommended. Check to see that the actuator fully opens and closes the internal valve without sticking. A build-up of mud, corrosion, or foreign material could prevent the actuator from closing, jamming the internal valve open. Do not permit this condition to occur. 4

Parts Ordering CAUTION These Actuators are produced with common automotive service chambers, customized specifically for use with Fisher valves. Do NOT use a standard, off-the-shelf service chamber for replacement as valve damage can occur. The service chamber push rod has been modified to work specifically with Fisher valves. Regulator Technologies recommends contacting your local distributor for replacement service chambers. When corresponding about this equipment, always reference the equipment type number found on the nameplate. When ordering replacement parts reference the complete 11-character part number of each part. Should the user desire to repair the service chamber diaphragm and outer clamp, it is recommended to contact the local Haldex (www.haldex.com) office for a listing of replacement parts and procedures for repairing your service chambers. Reference the SC09 brake chamber for the Types P613, P623, P639A, and P614A models, and the SC20 brake chamber for the Type P614 models. When ordering parts for your actuator you must note the month and date code on the actuator bracket (Figure 3). If your actuator was made prior to 10/09, order from the prior to 10/09 list. If produced 10/09 or later, then use the 10/09 or later list. Also, parts lists section on page 7 distinguishes the part numbers applicable for Type P614 or P614A. When ordering parts for Type P614A, use the corresponding part number provided for this model. Please note that an Actuator model that is before or after the 10/09 are fully interchangeable with the respective valves. Parts Lists for Types P613, P623, and P639A (Figures 4 through 6) Key Description Part Number Prior to 10/09 10/09 or Later Brake Chamber Assembly Repair Kits (include keys 8A, 8B,, 8D, and 8E) For Types P613, P623, and P639A GE31134X012 GE40920X012 1 Mounting Bracket, Stainless Steel Type P613 GE29439X012 GE40003T012 Type P623 GE29437X012 GE40004T012 Type P639A GE29438X012 GE40002T012 2 Hex Head Screw, Zinc-plated Steel (2 required) Type P613 1A407824052 1A407824052 Type P623 1A411624052 1A411624052 3 Hex Head Screw (3 required) Type P639A T12499T0012 - - - - - - - - - - - 5 Lever Types P613 and P623 GE29444X012 GE39989T012 Type P639A GE29444X012 ERAA02647A0 6 Cotter Pin 1H837128982 1H837128982 8 Brake Chamber Assembly - - - - - - - - - - - GE40920X012 9 Fuse Plug T1033699982 T1033699982 10 Push-in Fitting, Brass GE33586X012 GE33586X012 12 Spring Lock Washer (2 required) Type P613, Zinc-plated Carbon Steel 1C225628982 1C225628982 Type P623, Plated Carbon Steel 1C225728982 1C225728982 12 Spring Lock Washer (3 required) Type P639A 1C225728982 1C2257K0012 19 Nut, Stainless Steel (3 required) Type P639A - - - - - - - - - - - 1A309338992 20 Long Stud (2 required) Type P639A - - - - - - - - - - - ERAA02623A0 21 Short Stud Type P639A - - - - - - - - - - - ERAA02652A0 5

TORQUE: 96 TO 120 INCH-LBS / 10.85 TO 13.56 N m 12 2 5 6 1 8E 8A 9 8D 8B 10 GE31237 Figure 4. Type P613 for Type C484-24 Internal Valves TORQUE: 96 TO 120 INCH-LBS / 10.85 TO 13.56 N m 12 2 1 5 8B 8E 8A 6 9 8D 10 GE29523 Figure 5. Type P623 for Type C483-24 Internal Valves TORQUE: 90 TO 100 INCH-LBS / 10.2 TO 11.3 N m 20 21 20 19 20 12 3 6 1 8E 19 12 5 8A 19 12 21 9 8D 8B 10 GE31236 GE31236 Figure 6. Type P639A for Types C407, C471, and C477 (2 and 3-inch NPT) Internal Valves 6

3.0 INCHES P600 Series TORQUE: 96 TO 120 INCH-LBS / 10.85 TO 13.56 N m 4 5 6 1 8A 14 8E 8D 9 GE31240 8B 10 Figure 7. Type P614A for Type C404-32 Internal Valves Parts Lists for Types P614 and P614A (Figure 7) Key Description Part Number Prior to 03/15/12 03/15/12 or Later Brake Chamber Assembly Repair Kits (include keys 8A, 8B,, 8D, and 8E) For Type P614A only - - - - - - - - - - - GE40920X012 For Type P614 only GE31135X012 - - - - - - - - - - - 1 Mounting Bracket, Stainless steel Type P614A - - - - - - - - - - - GE45399X012 Type P614 GE29442X012 - - - - - - - - - - - 4 Hex Head Cap Screw, Zinc-plated Steel (4 required) Types P614A and P614 T1133624052 T1133624052 5 Lever, Stainless steel Type P614A - - - - - - - - - - - GE45407X012 Type P614 GE29510X012 - - - - - - - - - - - 6 Cotter Pin, Plated Carbon Steel Types P614A and P614 1H837128982 1H837128982 8 Brake Chamber Assembly Type P614A - - - - - - - - - - - GE40920X012 9 Fuse Plug T1033699982 T1033699982 10 Push-in Fitting, Brass GE33586X012 GE33586X012 14 Spring Lock Washer, Plated Carbon Steel (4 required) Types P614A and P614 1A505628982 1A505628982 7

CAM CAM LOCATION OF CAM BEFORE LOCKING THE CLEVIS LOCATION OF CAM AFTER LOCKING THE CLEVIS Figure 8. Cam Location LP-Gas Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872, USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 2002, 2013; All Rights Reserved