DUCTAC CENTREPOINT THEATRE TECHNICAL SPECIFICATION

Similar documents
Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

PRODUCTION SPECIFICATIONS

TECHNICAL SPECIFICATIONS.

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

STAGE SPECIFICATIONS. Newberry Opera House

SHUBERT THEATER 247 College Street, New Haven, CT

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

CIRCUS INCOGNITUS. Technical Rider Version: April 15, 2008

The Civic Hall in Bedworth Technical Specification

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL groteska@groteska.pl Update

Divadlo Inspirace (Ints-per-ats-zay)

MEETING PACKAGES 400 LEVEL

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

TECHNICAL SPECIFICATIONS Paramount website: Paramount

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay

Event Planner/Venue Specialist Phone:

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

Venue Information. Fritzclub im Postbahnhof Venue Information. FritzClub im Postbahnhof. Venue Adress. Straße der Pariser Kommune Berlin

TECHNICAL SPECIFICATIONS

CENTER THEATER TECHNICAL SPECIFICATIONS 404 SEAT PROSCENIUM THEATER WITH FLY LOFT

Cole 100 Auditorium. Equipment Use Instructional Guide

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

the audio/video + lighting menu

Lighting Inventory 2015

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

Watford s Major Entertainment and Hospitality Venue

One of the most incredible places on earth, Rolling Stone Magazine

Theatre Manager: Linda Aitken (03) ,

The new Gustave Eiffel Room On the 1st level of the Eiffel Tower

THEATRE USER INFORMATION GUIDE

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

Video & Data Display Equipment. Projection Equipment. LIGHTING EQUIPMENT Please call for customized Lighting Packages.

Brochure Event Production Suppliers Office Contact Sub Audio 2014

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

TECHNICAL RIDER HULK

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

Technical Specifications Version

TECHNICAL RIDER FESTIVALS 2015

Technical & Production information. Updated

TECHNICAL RIDER

Park 2015 Main Stage. Loudspeaker system

Equipment Guide Human Resources Training Room Suite 205, Building 3377

Allround lyd og lys. Wedges

SYDNEY OPERA HOUSE (Bennelong Point) GPO BOX 4274 SYDNEY NSW 2001 AUSTRALIA

AUDIO SYSTEM SPECIFICATION

An "influenced architecture", designed entirely in diagonals and transparency by the architects Moatti and Rivière, providing an improved experience

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

PA and Lighting Packages - Ready to Go

Guidelines for Technology Classroom Design

Equipment Hire Rate Card!

A laundry with washer, dryer, deep sink, sewing machine, full length mirror, steamer, and ironing equipment is also available.

Sweet Adelines Microphone and Sound System Guidelines

Soundcraft Multi Digital Card

How To Build A Large Room For A Conference

A/V and Video Conference Standards for Teaching and Learning Rooms.

SYDNEY OPERA HOUSE (Bennelong Point) GPO BOX 4274 SYDNEY NSW 2001 AUSTRALIA

SCD Server. SCD Server Pro

Co-designed by TASCAM and

Av das Américas 5.300, Barra da Tijuca, Rio de Janeiro RJ Brasil. CEP:

Perth Concert Hall. Technical and Production Information

Theaters Tilburg - Concertzaal. Address

Videoconference Room Guide

SOLUTION GUIDE AUDI TOR IUM. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

Main Library Meeting Room Use

Service Charges & Price List 2014

United States District Court District of Minnesota. Courtroom Technology Minneapolis

CONCERT HALL TECHNICAL SPECIFICATIONS

Interactive System Audio-Visual Equipment and Event Management

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

Funktional Technologies. Model: Chocolate Box

A1 Amplifier for 1x B2 Sub 750,00. D6 Amplifier 2-channel Digital 1850,00. EP1500 Amplifier 2x 450W/8ohm 135,00. PM1200 Amplifier 2 x 600W 275,00

CLASSROOM TECHNOLOGY GUIDE

Tallinn University School

R E N T A L E Q U I P M E N T [All Prices Exclude GST]

NCSU CBE Conference Room 2018 EB1 Touchpanel Users Guide

Auditorium Audiovisual System User s Guide

Technical Requirements for Zoe Juniper

Conference Equipment Rental

Technical Information. Policies & Procedures. Fee Schedule for Rental & Services

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

MULTIPLE LINE ELECTRO-VOICE INSTALLATION A SURE SHOT AT DOC HOLLIDAY S COUNTRY BAR, ERIE, PA

VENUE RENTAL OVERVIEW

Production Specification.

Classroom Technology Emergency Hot Line. Amherst College Classroom Technology Support. Classroom Equipment Guide. Fayerweather Classrooms

STAS MIKHAYLOV - Technical rider (for PRIVAT PARTY). 1. PA SYSTEM. P.A. Professional quality, stereo multiway (4 - way) system with active

alaire diego cortés cristo fontecilla xavi turull TECHNICAL RIDER

ChamSys. Inspiring Performance. MagicQ Compact Series

CONTACTS: * Alejandra Gómez [Management] alejandra@biche.com.co (+57) * Julián Salazar [Director] infomitu@gmail.com (+57)

Craftsound prijslijst 2014

Scale of Hire Charges

Rental Policy & Pricing 2013

Auer Hall Technology Instructions

Transcription:

DUCTAC CENTREPOINT THEATRE TECHNICAL SPECIFICATION Technical Manager: Craig Burgess c.burgess@ductac.org +971 (0) 4341 4777 ext 329 Chief Technician: Philip Fortaleza p.fortaleza@ductac.org +971 (0) 4341 4777 ext 218 Technician: Anthony Manalo a.manalo@ductac.org +971 (0) 4341 4777 ext 334

Seating Our main auditorium is tiered on two levels (Stall and Balcony) and has the capacity of 543. Provision is made for four wheelchair usage. Our first two rows are removable to facilitate an orchestra pit. Also there are two VIP boxes (4 seats each) situated on both side of the balcony, two VIP boxes (8 seats each) at rear of stall next to both side of the technical control room. Stage Flat built timber covered sprung floor painted black with 12m x 7.2 m proscenium opening Performing area: 12m W x 10.8m D x 15 m to grid. 17.5 to hanging points (RSJ) Wing space: S.L. 3.2m W x 8 m D x 6 m H; S. R. 3.3m W x 9 m D x 6 m H Communication Stage Manager s desk is located at Stage Left with cast call paging system, cue light control and clear COM talkback system. Six intercom lines with headsets can be installed at control box (2 points), SR, SL. Fly floor or Follow spot room. Flying System 6 counterweighted bars (SWL 350 kg) Operated on the SL gallery 5 motorized bars (SWL 350 kg) Fixed control panel DSL 1 motorized bar with cyclorama/blacks (SWL 350 kg) 4 hemp bars (SWL 350 kg) tied off on the SR gallery 2 hand winched bars in wings (6x available lighting ladders) 10 3m Fixed bars for legs (Masking) Masking and soft Hanging 1 set of red velvet house tabs (permanent attachment) 1 set of black mid-stage tabs (permanent attachment) dead hung 5 sets of black soft legs (3m x 8m - fixed) dead hung 3 Black soft borders (3m x 16m) 1 White cyclorama (16m x 7m) 1 Black backdrop (16m x 8m) 1 Black gauze (16m x 8m) Get-In / Access All vehicles arriving must be less than 2.8m high to park/unload on level 2 (DUCTAC) Loading platform is 0.75m above driveway level with roller shutter door of 4m wide / 6m height Larger vehicles can unload at Loading Bay 10 and use the large lifts to get to level 2 (DUCTAC) Lift door size is 2.40m (7.87ft) x 2.40m (7.87 ft). Maximum lift load is 5000 kg. Dock is Large and has easy access to stage with high scenic doors

Sound Control room is located at the rear of the stalls. Console: MIDAS Pro2c digital console including 8 integral mic/line inputs with MIDAS mic preamps, 64 simultaneous input processing channels, 8 VCA s, 6 POP groups. For more info: www.midasconsoles.com Stage box/facility panels: 1 MIDAS DL521 I/O box. 48 Inputs & 16 Outputs 4 fixed panels located - USL (8 In & 4 Out), DSL (12 In & 4 Out), USR (8 In & 4 Out), DSR (12 In & 4 Out). Sound System: VQnet Software controls the main system. This is networked with VQnet enabled cabinets giving full control via a computer located in the control room, next to the main sound console. Main System: 2x Tannoy VQnet 60. 2x Tannoy VQnet 218 Centre Cluster: 2x Turbosound TQ 315 Crown IT Series amplifiers Front Fills: 4x Turbosound TCS-35 Crown IT Series amplifiers Balcony: 3x Turbosound TCS-40 Crown IT Series amplifiers On Stage Foldback/Monitoring: 4x Turbosound TFM 212 (Wedge) 2x Turbosound TQ 315 & 2x Turbosound TQ 425 (Side Fills) Crown IT Series amplifiers Microphones: 4 Shure SLX Wireless 84 Lavaliere/Lapel with belt pack - HIRE CHARGE AED 200 per day 4 Shure SLX Wireless SM 58 & 4 BETA 58 Handheld - HIRE CHARGE AED 200 per day 6 Sennheiser MKE 1 Wireless with belt pack HIRE CHARGE AED 350 per day 2 Sennheiser MEG 14-40 B Gooseneck HIRE CHARGE AED 40 per day 5 Shure SM 58 HIRE CHARGE AED 40 per day 6 Shure SM 57 HIRE CHARGE AED 40 per day 4 Shure BETA 87A HIRE CHARGE AED 60 per day 2 Shure SM 81-LC HIRE CHARGE AED 60 per day 1 Shure BETA 52A HIRE CHARGE AED 60 per day 3 Crown PCC 160 HIRE CHARGE AED 60 per day 4 DPA 4060 FM head-set HIRE CHARGE AED 90 per day 8 DPA 4098HB hanging mic HIRE CHARGE AED 50 per day 16 K&M tall boom mic stands, 4 K&M short boom mic stands

Outboard: Yamaha SPX2000 1 KLARK TEKNIK Parametric EQ 1 KLARK TEKNIK Compressor 6 KLARK TEKNIK 31 Band EQ Playback equipment: 1 Sony CD player 1 Tascam 350 Mini disc recorder 2 Tascam 112MKII cassette recorders Audio Recording: A stereo mix from the console can be recorded in digital formats. Please note advance notice is required for set up. HIRE CHARGE AED 500 per day Lighting Control room at rear of stalls Consoles: ETC ION 20 fader sub master wing, itouch remote, fully networked, 2 DVI screens Strand 300 Classic Palette 250 channels, 24 sub master, Tracker, Net worker, WYSIWIG Martin M2GO 4 DMX universes, 1000 cue lists, Submaster, Groupmaster and Override functionality. Luminaries Hui Flood 24 1000w Rama PC 15 6 12 1200w 7 55 Rama PC 15-6 Fresnel 20 1200w 5 60 Pacific Profile 16 1200w 14 35 Pacific Profile 6 1200w 12 28 Pacific Profile 6 VNZ 1200w Profile 4 26 600 W Profile 4 23 50 600 W Profile 4 15-32 600 W Par 64 12 1000w Arena 6 2500w spot flood Arena 6 2000w spot - flood Robe Spot 250 AT 8 250 W moving yoke lighting fixture HIRE CHARGE AED 100 Martin MAC Aura 16 LED wash fixture HIRE CHARGE AED 150 per unit / per day Altman Spectra 200-CYC 10 LED CYC wash fixture Clay Paky Shadow ST 2 Follow Spot 1200 W full colour changing HIRE CHARGE AED 350 Colour Scroller 15 15 Colour scroller Martin Atomic 3000 1 DMX Strobe Light 3000W Blues/Working Light Blue LED fixtures are installed in the control room and in each wing for show working light The stage has fluorescent strip lighting for working light during fit up s and get out s Accessories and Effects 1 JEM ZR33 Hi Mass Smoke HIRE CHARGE AED 300 per day 1 Martin Magnum Hazer Machine HIRE CHARGE AED 300 per day 15 Metro-deck stage units (Different size legs available) HIRE CHARGE AED 80 per day Acrylic Lectern (Including goose neck microphone) HIRE CHARGE AED 100 per day

Harlequin Dance Floor (Black/Grey) HIRE CHARGE AED 1,300 per day Projection Eiki LC-XT3 - LCD Projector XGA 10,000 ANSI lumens mid throw zoom lens HIRE CHARGE AED 2,000 LG - DVD/VCR player PC Laptop / Macbook Pro HIRE CHARGE AED 250 per day Resolution of projection = 1024 x 768 ONLY DVD, VHS or LAPTOP (VGA) formats will be accepted 4.5m / 6m projection screen (Front projection) Power Stage Left 1x 32a Single Phase (Sound Only), 1x 63a Three Phase, 1x 16a Single Phase, 13a Sockets (Various) Stage Right 1x 32a Single Phase (Sound Only), 1x 63a Three Phase, 13a Sockets (Various) Control Room 13a sockets only (Various) Scene Dock 3x 16a Single Phase, 3x 32a Three Phase, 13a sockets (Various) FOH 13a sockets only (Various) Dressing Rooms/backstage Dressing rooms: Total 7, all equipped with ablutions, can accommodate up to 104 performers With show relay/cast paging. Wardrobe: 1 washing machine, 1 dryer, 10 hanging rails Dressing Room Dimensions and Capacity Below shows the Maximum capacity all Dressing rooms & Wardrobe. Dressing Room 1, 2, 3 and 4 4520mm (14.83ft) x 5275mm (17.31ft) = 256.71 ft2 / 36 = 7 people only. We can round off this to 10 people only. Dressing Room 5 5390mm (17.68ft) x 7725mm (25.34ft) = 448 ft2 / 36 = 12 people only or we can round this off to 15 people only. Dressing Room 6 7960mm (26.11ft) x 4295mm (14.09ft) = 367.89 ft2 / 36 = 10 people only or we can round this off to 13 people only. Dressing Room 7 5390mm (17.68ft) x 3400mm (11.15ft) = 197.13 ft2 / 36 = 5 people only. Wardrobe 10,380mm (34.05ft) x 9095mm (29.83ft) = 1,015 ft2 / 36 = 28 people or we can round this off to 31 people only. TOTAL of 104 people only. Centrepoint Theatre Stage Regulations for Visiting Companies No Live naked Flames (Candles/Torches etc)

No access to Control Room, Fly floors, Bridges & Grid areas without DUCTAC Technical staff supervision No rigging from the Grid unless discussed with the Technical Manger and Risk assessed Flying counterweight or motorized systems should only be operated by DUCTAC Technical staff (If flying is required during your show please give advance warning so staff can be allocated) No water pools or water effects Pyrotechnic and smoke effects should be discussed in advance with the Technical Manager Use of compressed gasses must be discussed in advance with the Technical Manager Use of the Tallescope and other access equipment may only be used by DUCTAC staff unless otherwise agreed A pre-rig may not always be achieved before your arrival Please send Lighting/Stage plans ASAP to help us prepare for you Please give advance warning for deliveries (We need to seek permission from the mall security) Get out s should start immediately after the show, removing Sets off site unless agreed by the Technical manager (We do not have space to store Sets/Props) No eating or drinking on stage, control room & Auditorium Health & Safety is taken very seriously in our venue and we reserve the right to cancel the show if we do not deem it safe No camera JIB s / Cranes allowed in the auditorium External lighting fixtures must be supplied with rated safety bonds/chains

LOADING BAY 10 MAP