SYSTEM FOR INSULATED PANELS. Konnektor ACCREDITED. System for insulated panels

Similar documents
Technical handbook Panel Anchoring System

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Detailing of Reinforcment in Concrete Structures

Dubai Municipality Standard DMS 1: Part 5: 2004

TARIFF CODE and updates standard

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Installation Manuals Version n. 01 of 14/06/2013

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Machine devices, jig devices

MONDOATHENS BASKETBALL SET (Reference PK110)

Modular Access Floor for Data Center. From Rack to Row to Room to Building

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Hanson Building Products. precast basement solutions

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Aluminium systems profile selection

Mechanical arms, belts and sheets

Mounting Instructions for SP4 Power Modules

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SINTEF Building and Infrastructure. Contents

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

James M. Pleasants Company

4 Installation Requirements

Cable Trays Technical Instructions & Specifications

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Embedded Parts Introduction - Anchors

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

DE Frame with C Series Sidelight

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

39HQ Airovision Air Handling Units

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

LAYING BLOCK AND BRICK

Residential Garage Door Terminology

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

Subminiature Load Cell Model 8417

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

Integral Kit Instructions

Connection Solutions

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

Design and Construction of Cantilevered Reinforced Concrete Structures

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

19 DYNAmax Free Standing Server C A B I N E T s

General Allowances for Insulation & Cladding

Awning Instructions. Standard Manual 1.5m to 4.5m

EAST LYME HIGH SCHOOL

Dear costumers, You have just received our new catalogue with KOPOS KOLIN a.s. offer of metal cable support system products. Those types of products

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

SECTION 6. Glass Storefront Doors:

Fire Barrier Duct Wrap 15A

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Quality Regulations for Profiles

Testing Rules for Thermal Conductivity October 2015

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Nuffield and Middleweight Leyland Tractor - 11 inch - Double Clutch Overhaul Part 1 - Clutch Removal and Dismantling

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Elevating Your House. Introduction CHAPTER 5

19 DYNAmax Free Standing Server C A B I N E T s

Free piston Stirling engine for rural development

APE T CFRP Aslan 500

Sheet metal operations - Bending and related processes

Design Manual to BS8110

City of San Diego, CWP Guidelines

FRACASSO SCAFFOLDING PS 720

INTRODUCTION TO BEAMS

12.1 Schlüter -KERDI-BOARD

PB accessories. PB accessories. Labelling option. Order Information B Printed board handle A BZA42727 BZA42724.

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Highly flexible couplings

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

IPR Äspö Hard Rock Laboratory. International Progress Report. Temperature Buffer Test. Report for retaining plug and anchoring

Chapter 3 Pre-Installation, Foundations and Piers

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

SECTION WINDOW WASHING SYSTEMS

Transcription:

SYSTEM FOR INSULATED PANELS 1 ACCREDITED Konnektor System for insulated panels

2 Konnektor System for insulated panels WHAT IS KONNEKTOR? Konnektor is a patented system that uses support and connection devices between two freely expansible reinforced concrete layers, for the construction of concrete panels with insulation and structural section. Panel with insulation. Panel with insulation and lightened carrier layer. Ventilated panel with insulation. The connecting devices between the two layers are designed to allow the construction of panels without size limit. Konnektor allows the production of panels with insulation of various kinds: lightened, aerated, and ventilated. SUPPORT DEVICES The supports are bound to the carrier layer and bear the weight of the supported layer in an isostatic manner, without preventing thermal expansions/contractions of the hanging layer. They are made with a Ø 40 mm galvanized steel pin, which is anchored in the carrier layer and supports the load of the hanging layer. At the base of the supports, suitably shaped, a metal bar (hereinafter called guide) is installed to distribute the load and to be fixed to the reinforcing mesh of the hanging layer, keeping the support in the appropriate position during casting operations (Fig. 1). Fig. 1 The support is anchored to the reinforcing mesh of the hanging layer.

When the guide is filled with concrete, a hinge is created (fixed support); the free guide, provided with its appropriate sponge, is a sliding system which can be moved up to 8 mm (sliding support). The bar that acts as a guide to the sliding support is coated internally with Teflon, a material that allows canceling internal friction, guaranteeing sliding between layers in any situation. Around the pin, the insulation thickness should be reduced, creating a cylinder of at least 12 cm in diameter within which the fretting spring is located. As summarized in table 1, the insulation thickness in the area around the support may be maximum 4 cm, compatibly with the required carrying capacity and strength of the concrete. PN = RATED CARRYING CAPACITY OF SUPPORT (KN) insulation Rckj (N/mmq) layer thick s (cm) 10 15 20 25 30 1 19 29 38 48 48 2 14 22 29 36 36 3 12 18 24 30 30 4 10 15 20 25 25 Tab. 1 50 cm 12 cm KONNEKTOR 3 Especially for vertical panels, which, after being balanced, unload all the weight of the outer layer only on the fixed support, the carrying capacity of the support should be used as much as possible, reducing up to 1 cm. max 10 s 6 Using insulating panels with thickness greater than 4 cm, it is always necessary to operate a reduction as shown in figures 2 and 3, depending on whether there are reinforcements or not. Fig. 2 15 cm During formwork removal, storage, and transport, all panels are always considered horizontal. During formwork removal, which is characterized by a reduced strength of concrete, it is necessary to set the number of supports and the insulation thickness on each support. The number of supports is determined in relation to the weight to be supported, panel dimensions, and thickness of the hanging layer. The cases that can be found are summarized in figure 4. Fig. 3 Fig. 2 and 3 Reduction of insulation around the supports. The reduction of the insulation, and possibly lightening, must be such as to enable full development of the distribution load at 45 in the carrier layer from the fretting spring plate, with the exception of cases in which the support is within a reinforced curb. Fig. 4 In a small size panel, the fixed support only should be exactly in the center. To avoid torsion effects during handling, a double crossed fork should be added or continuous connections should be used. In panels with two supports, they are placed on cross curbs at a distance from the edge between 0.2 and 0.25 L. In long horizontal panels, the fixed support is designed to be in the center and the two sliding supports are placed at a distance from the edge between 0.1 and 0.25 L. It is advisable, in the case of vertical panels, to put F at the base or on the head.

4 Konnektor CONNECTION DEVICES It is planned to give a type of perimeter connections installed after laying of the insulation (C10 and Forks) and a second type, an alternative to the previous one, which is put in place before casting the hanging layer, simultaneously with the support devices (continuous connections). The choice is made in relation to the production method and time of concrete setting. All types of perimeter connections are made of stainless steel and prevent that the carrier layer is detached from the carried layer, leaving them to be free and independent to dilate or contract. When the panel is made on folding tables, the connections keep the 2 layers connected in handling during storage, transport, and assembly, resisting to wind suction in place. If the panel is manufactured on fixed platforms, the connections also support the direct weight of the carried layer during tilting. If the traditional method is used, by inserting the connections after laying of the insulation (Fig. 5), the nominal carrying capacity of connectors C10 and Forks is in relation to the strength of concrete and is reported in Table 2. Unlike the forks, C10 connectors were made with stainless steel wire cables consisting of very small diameter wires, which bend without yielding and effectively anchor in wet concrete. The follo-wing figures show the insertion procedure of C10 connectors. First, the C10 connector is coupled to the polystyrene spacer, the height of which is determined according to the insulator thickness to ensure a fixed distance of 10 cm between the two anchoring points. Subsequently, the two ends of the cable are folded manually. The C10 connectors allow a relative displacement between the two layers of about 1 cm. The forks are simply pushed into the insulation layer from above, until they reach the bottom of the caisson or the outer finishing layer. Tab. 2 RATED CARRYING CAPACITY OF CONNECTORS Cls Rcj (N/mm 2 ) supportable kn m 2 supportable for thickness 6 cm 10 1,50 1,00 0,86 15 2,25 1,50 1,30 20 3,00 2,00 1,72 25 3,75 2,50 2,15 30 4,50 3,00 2,60 for thickness 7 cm Connector C10 Fig. 5 The polystyrene tubular bar is used as the template to give the right penetration of the 2 cable ends in the concrete.

GREY PANEL GRIT PANEL STEP 1 spacer H30 mm distanziatore wire mesh KONNEKTOR 5 wire mesh grit Fig. 6A To disconnect manufacturing from concrete setting time, ensuring formwork removal on the next day, it is possible to use C-shaped and knurled continuous connections. These items are 2 meters long and are made of stainless steel to keep high ductility, as it is certified by laboratory tests carried out at the ITC-CNR in Milan. It is planned to have a connection every 50 cm on the entire perimeter and possibly in the central curb for panels of a width exceeding 2.50 meters. The connections are placed by fixing them to the wire mesh of the hanging layer (see casting sequence in Fig. 6). The choice of the type of continuous connection to be used is guided by the type of reinforcement or shape of the formwork bank; their behavior for the purpose of formwork removal is still the same. Fig. 6A GREY PANEL 1. Position of the wire mesh with 3 cm spacer. 2. Laying on the wire mesh and anchoring with at least two brackets of pebbled connections. WASHED PANEL 1. Casting with 3 cm grit. 2. Straight edge of grit. 3. Laying on the wire mesh and anchoring with at least two brackets of pebbled connections. Fig. 6B Completion of supported layer casting. Fig. 6C Positioning of the insulating material layer in double layer, or interposing a polyethylene sheet between the carrier layer and the insulating layer. Fig. 6D Positioning of reinforcements and lightening material. Fig. 6E Casting of the carrier layer. STEP 2 STEP 3 Fig.6B Fig. 6C STEP 4 STEP 5 Fig.6D Fig. 6E

6 Konnektor Design criteria To determine the number and type of connections, in the design stage, reference is made to a calculation program (Fig. 7), ICMQ certificate, which is provided free of charge and also allows the check of transmittance in relation to the regulations in force. DESIGN OF SUPPORTS In horizontal panels, the number of supports is decided by the weight of the carrier layer and the strength of concrete at the time of formwork removal (see Table 1). The vertical panels are removed from the formwork, stored, and transported as if they were horizontal panels, i.e. distributing the weight of the carried layer on all the supports. When, upon assembly, it is rotated by 90 to bring it into the vertical position, the whole weight of the carried layer is loaded on the fixed support only, which is anchored to a carrier layer and has its final strength. The support is inserted into a concrete volume side 15 cm, in a position coinciding with a rib. If, during assembly, the support cannot be entered in a rib on its vertical side (as is often the case in vertical panels), a reinforcement of the concrete volume should be prepared consisting of two vertical brackets Ø 14 (Fig. 8). For very high vertical panels, it may be necessary to put two fixed supports in one transverse bead, taking care to keep them spaced apart by at least 50 cm. Sometimes, for example when there are doors inserted in the panel, the end connection between the two layers can be considered a fixed point and it will be possible to put only one sliding support. PROGETTAZIONE DESIGN OF CONNECTION DEI CONNETTORI DEVICES Fig. 7 Page taken from a calculation software with Ruredil Konnektorr Fig. 8 Reinforcement of the supports when there is no longitudinal reinforcement curb. The frequency of connectors can be found in table 2. Of these, the frequency of connectors C10 may be determined assuming the characteristic strength of concrete after curing, and interposing a fork between two C10 connectors. In installed panels, it is intended to yield due to expansion. In any case, it will be very useful in the early handling stages with lower strength concrete. Other forks are positioned in correspondence of anchors by tilting, or edges due to the presence of openings or protrusions in the panel, which are the most stressed points during formwork removal. The forks H160 are used for insulations with up to 6 cm thickness; for thicker panels, sup to 10 cm, H200 forks are necessary. Regarding the design of continuous connections, it will be sufficient

Konnektor Thermal performance to calculate the perimeter of the panel and possibly the presence of openings, to obtain the linear meters of connection required. In this case, reinforcements are not needed at the anchors. For insulation thicknesses from 8 to 10 cm, H200 knurled connections are to be used. As an example, two situations are reported as follows: KONNEKTOR 7 Positioning of supports and knurled connections in the panel. CALCULATION OF THERMAL TRANSMITTANCE OF PANELS The reference standard for calculating the transmittance of components for building is UNI EN ISO 6946:2008. This simplified calculation method is implemented in the system software which also provides an alternative method, if the limits of applicability of the simplified method are exceeded. detail A detail A Panel with insulation structural section detail A detail A Panel with through thermal bridges Considerations The Konnektor system requires no special compressive strength of insulation other than that required to withstand the wind pressure. It is therefore also possible to use the cheapest insulation (if the insulator is polystyrene, with EPS 70). It is always recommended to use the insulation in a double overlay sheet to reduce the frictions between the two layers due to the expansions and, at the same time, to close the thermal bridges between juxtaposed slabs. The advantage of structural cutting is to avoid that the panel is deformed by curving with different temperatures of the layers. (Fig. 9) When requested, humidity control must ensure that no condensation is formed inside the panel, for which a vapor barrier may be needed. Ventilated panels eliminate the internal condensation in the winter, leaving a breathable wall, and in the summer they do not allow sunlight to increase the internal temperature. Fig. 9 Panels without structural section often take non-acceptable curves on a daily cycle, while structural section panels are not exposed to these problems.

8 Konnektor Operation steps 1 2 3 4 5 6 7 8 9 10 1 Once the formwork has been prepared, Ø 5/15 wire mesh of the supported layer (e.g. 6 cm) is placed on 3 cm spacers (or, possibly, on the layer of grit already casted). The supports should be placed vertically and anchored to the wire mesh using two extra Ø 8 rods with a length of at least 25 cm to be inserted into the holes of the guide. The guide must always be parallel to the longer side of the panel, without distinction for horizontal and vertical panels and for each type of support. At this stage, also C shaped and knurled connections are anchored to the wire mesh along the entire perimeter of the panel.. 5 If continuous connections are not used, C10 connectors and the forks shall be inserted at this stage. Between operations 3 and 5, using the C10 connectors and forks, concrete should not start setting. 6 The lightening insulation is placed. The wire mesh of the carrier layer is placed. The upper concrete cast is completed, making sure to vibrate with needle or through paver, then making the final straight edge. 2 The carried layer is casted to the upper edge of the guide, which will be consequently at 6 cm. If the thickness of the hanging layer is more than 6 cm, the spacers for wire mesh shall be selected accordingly (example 7 cm = 4 cm spacer). 7 De-molding. For panels longer than 8 meters, it is recommended overturning by 4 anchors. 8 Storage. 3 The insulation is positioned in double layer or interposing a polyethylene sheet over the entire surface, between the carrier layer and the insulating material, the appropriate holes are drilled and reductions are made on the supports. If required, the vapor barrier is laid on the insulating layer. 9 Transport. 10 Assembly. In steps 8, 9, 10, the panels must be placed on the carrier layer only. 4 The reinforcing cage with its lifting anchors is prepared. To speed up the operations, it is necessary to prepare the reinforcing cage (preferably with the anchoring material already in place).

Konnektor Description of items Ø 9 1 SUPPORTS (FIXED AND SLIDING) Ø 72 Ø 40 165 Ø 120 Code Item Pack. 0318002001 Fixed Support 6 pcs. 0318003001 Sliding Support 6 pcs. Materials: A: FIXED SUPPORT - pin Ø 40 mm ST 52.3 galvanized - section bar: Fe 37 galvanized - spring: C70 galvanized - electrolytic galvanization UNI-ISO 2081 standard B: SLIDING SUPPORT - filling with synthetic foam - SECTION BAR: Fe 37 with Teflon internal coating KONNEKTOR 9 H 2 SPACER Polystyrene spacer 3 CONNECTOR C10 110 60 50 14,5 220 35 7,5 35 25 120 50 Code Item Pack. 0318051001 Spacer H 40 500 pcs. 0318051002 Spacer H 60 500 pcs. 0318051003 Spacer H 20 500 pcs. Materials: - polystyrene d 25 kg/m³ sizes on request H = 20 / 40 / 60 Code Item Pack. 0318052001 Connector C10 500 pcs. Materials: - cable AISI 316 Ø 3 mm - nylon + glass fiber tubular bar Connector C10

10 1 Konnektor Description of items Third Edition 06/2016 4 FORK Code Item Pack. 0318004001 Fork H 160 500 pcs. 0318031001 Fork H 200 500 pcs. Materials: - stainless steel 160 200 2,8 2,8 Fork H 160 Fork H 200 5 CONTINUOUS CONNECTIONS Code Item Pack. 500 500 500 0318055001 C Connection 40 meters 0318054002 Knurled connection H 200 40 meters 0318054003 Knurled connection H 260 40 meters Materials: - Stainless steel 1980 180 C Connection 500 500 500 500 500 500 1980 1980 200 260 Knurled connection H 200 Knurled connection H 260