Compact Light Fitting Series C-LUX 6100 / 6500

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices SolConeX 16 A Series 8570

Terminal Boxes Series 8146

Series 8146/5-V37 and Series 8150/5-V37

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

7 Lighting Technology

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Emergency Light Fittings

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Control and Distribution Boxes made of Stainless Steel Series 8150

Control Stations Made of Polyester Resin Series 8146

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

A good connection. International approvals.

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Control Stations in Sheet steel or Stainless Steel Series 8125

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

9 Control Equipment. Control Button Series 8082

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Floodlight Range Installation Guide

H45 LED - Direct and indirect pendant

type V46, solenoid or pneumatic operated

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

e explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/ nd 187/188...

Medical Lighting. XL4 Patient Light

Wolflite Safety Handlamp H-251E

Technical Data. Dimensions

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Mureva Assembly surface mounted wiring devices

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Solenoid Valve Island Type 3965

HERZ-Thermal Actuators

Digital inductive conductivity transmitter

120W High Bay II Datasheet

Acclaim III Recessed Fluorescent Luminaires ATEX

Electric Rotary Actuator - On/Off or programmable control actuator

Operating Instructions

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

COOL Shelf Quick Connect

Guide to enclosures for potentially explosive atmospheres

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Abtech Custom Solutions

3/2-way pneumatic cartridge solenoid valve

400 Series Buccaneer BUCCANEER POWER. bulgin

8146/5 Series Breaker Panelboards

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Product and functional description

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

ACS-30-EU-EMDR-10-MOD

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Control- and feedback head for integrated mounting on Robolux valves Type 2036

UM-X Field display for continous level sensors

Electro-pneumatic control valves

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat


HARTING Ethernet Cabling 4-poles Overview

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Redundancy Module QUINT-DIODE/40

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Morgue refrigeration unit

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Low / High Bay Datasheet

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

TEIP11 I/P signal converter for standard signals. Measurement made easy

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

ASSEMBLED SOCKET-COMBINATIONS

46120-F0 Solar Energy Training System

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Operating Instructions Bedienungsanleitung Mode d emploi

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

High / Low Bay Datasheet

Technical Information RIA14

Product Information Sheet UH36 Hi Pot Tester

New XUY roller sensors

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

High / Low Bay PC Reflector Datasheet

TIG INVERTER INSTRUCTION MANUAL

Technical Data. Dimensions

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

How To Build A Low Voltage Capacitor Lvcp

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Software and Display instruments

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings

Compact pressure switch Flameproof enclosure Ex d Model PCA

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

WE-350 Series ¼ Turn Electric Actuator

ELECTRICAL PLUG TYPE CONNECTIONS

Cable Plug acc. to DIN EN , Form A

Emergency Lighting Introduction

Transcription:

> Suitable for wall or ceiling mounting > Can be fitted to order with emergency exit signs > Central locking > All-pole disconnection via N/C switch when cover is opened (Series 6100) www.stahl.de 01907E00 Series C-LUX 6100 and 6500 compact light fittings can be used for normal lighting, but also as information fittings or as group- or centrally-powe emergency lights. ATEX / GOST* Zone 0 1 2 20 21 22 C-LUX 6100: For use in x x x x C-LUX 6500: For use in x x x *) only 6100 WebCode 6100A Lighting /1

Selection Table Version Lamps Lamps Electronic ballasts Order number Weight C-LUX 6100 Zones 1, 21 piece kg Fluorescent lamp 1 x 8 W 1 6100/1081-8011-3430-00 3.390 2 x 8 W 1 6100/1082-8011-3430-00 3.500 2 6100/1082-9011-3430-00 2.400 3 x 8 W 1 6100/1083-8011-3430-00 3.530 2 6100/1083-9011-3430-00 2.600 C-LUX 6500 Fluorescent lamp 1 x 8 W 1 6500/1081-8010-8430-00 2.400 Zones 2, 21, 22 2 x 8 W 2 6500/1082-9010-8430-00 2.500 3 x 8 W 3 6500/1083-9010-8430-00 2.600 DULUX-L lamp 1 x 24 W 1 6500/3241-8010-2430-00 2.400 Incandescent lamp 1 x 60 W - - 6500/6601-0010-0430-00 2.150 2 x 40 W - - 6500/6402-0010-0430-00 2.300 Order Number Supplement Cable entries Standard: 1 x cable gland M25 x 1.5 6.00/...-..1.-...-.. 2 x stopping plugs M25 x 1.5 Special: Specify non-standard entries in writing 6.00/...-..9.-...-.. Monitoring module without 6.00/...-...-...0-.. with 6.00/...-...-...2-.. Emergency exit needed only when used as information lights or escape sign lights; With adhesive symbols positioned as follows: Mounting position Standard Special please specify other positions in writing Please specify emergency exit sign number (see below) Symbol complying with VGB 125, DIN 4844, DIN 5035; recognition distance e = 30 m; size 150 x 355 mm 08481E00 without emergency exit sign 6.00/...-...-...-00 6.00/...-...-...-60 08483E00 6.00/...-...-...-61 08482E00 6.00/...-...-...-62 08484E00 /2 Lighting

Order Number Supplement Emergency exit 6.00/...-...-...-91 08485E00 03206E00 6.00/...-...-...-71 6.00/...-...-...-81 12617E00 6.00/...-...-...-92 08486E00 6.00/...-...-...-72 09020E00 12618E00 6.00/...-...-...-82 08487E00 6.00/...-...-...-90 6.00/...-...-...-70 03203E00 6.00/...-...-...-80 12616E00 6.00/...-...-...-93 08488E00 6.00/...-...-...-73 12615E00 6.00/...-...-...-83 12619E00 Note Compact light fittings can be operated as emergency lighting via a group or central battery system; fittings are supplied without lamps, which must be orde separately; further escape and information signs available on request. Lighting /3

Explosion Protection Europe (ATEX) Gas Zone 1: PTB 97 ATEX 2119 Zone 2: SNCH 03 ATEX 3558 Zone 1: E II 2 G EEx eds IIC T4 Zone 2: E II 3 G EEx n A II T4 (T3 for incandescent lamps) Dust Zone 21: LCIE 03 ATEX 6158 Zone 21: SNCH 03 ATEX 3557Zone 22: SNCH 03 ATEX 3558 Zone 21: E II 2 D IP66 T130 C Zone 21: E II 2 D IP66 T 1) Zone 22: E II 3 D IP66 T 1)1) T85 C for 8 W lamps; T68 C for DULUX L lamps; T117 C for incandescent lamps Certificates and approvals Certificates Technical Data Electrical data Rated voltage ATEX, Canada (CSA), Kazakhstan (GOST-K), Russia (GOST-R), Serbia (IZP), Belarus (GOST-B) for fluorescent lamps: for DULUX-L lamps: for incandescent lamps: ATEX, China (CQST), Canada (CSA), Russia (GOST-R), Serbia (IZP), Ukraine (GOST-U), USA (FM), Belarus (GOST-B) AC: 220 (- 10%)... 240 (+ 10%) V; 50 / 60 Hz DC: 198... 250 V AC: 220 (- 10%)... 240 (+ 6%) V; 50 / 60 Hz DC: 176... 254 V 230 V Disconnection of light fitting on opening Central locking device with safety interlock; switch 8080 with N/C contacts; when central lock is opened, voltage to ballast is disconnected on both poles;a safety interlock in switching mechanism prevents fitting from being reconnected while cover and central lock are open. Standard light fitting 6500: without swtching off Faulty lamp If lamp is faulty power supply is automatically switched off by electronic ballast Luminous Characteristics Lamps Fluorescent lamps DULUX-L Incandescent lamps Number of 1 x 8 W 2 x 8 W 3 x 8 W 1 x 24 W 1 x 60 W 2 x 40 W lamps Electronic 1 1 2 1 2 1 - - - - ballast Rated current 0.088 A 0.135 A 0.176 A 0.2 A 0.223 A 0.11 A 0.30 A 0.39 A Light guides Reflector painted ; Cover with prism structure providing directed light from fitting Operating modes Mains operation for general lighting or as information lights. Emergency light operation, supplied from group or central battery system for emergency or escape route lighting. Ambient conditions Ambient temperature -20... +50 C -20... +50 C (with fluorescent lamp) -20... +40 C (with DULUX-L lamp) -50... +40 C (with incandescent lamp) Mechanical data Degree of protection IP66 (IP64 with breather 8162) Protection class I(with internal PE connection terminal) Material Enclosure glass fibre reinforced polyester resincolour:, similar to RAL 9010 Lamp cover Polycarbonate Seal Polyurethane; foamed into cover Cover options Central locking using socket spanner M8 / SW 13; cover hinged for access central lock cover hinge 08478E02 /4 Lighting

Technical Data Assembly / Installation Cable entry Standard Special version Connection Terminal size Marking Terminal block Installation notes Mounting Looping through of cables 1 cable entry 8161 in plastic, M25 x 1.5 and 2 plugs 8290 in plastic, M25 x 1.5 (enclosed) Other entries in moulded plastic or metal are available to order - details available on request. 2 x 4 mm 2 for solid cores 2 x 2.5 mm 2 for flexible cores L, N, PE in polyamide with cover Can be wall- or ceiling-mounted 2 leads can be connected to each terminal on the input side, making fittings suitable for looped connection Monitoring module Function Monitoring and switching module for emergency light systems according to VDE 0108: The module is used for the monitoring of individual lights and for the control of network and safety lights. The module offers the following functions: Control of the light (ON / OFF) and function test Up to 20 addresses can be set for each electric circuit by means of a coding switch The operating mode of the lamp (continuous light, stand-by light or activation by means of a switch) is freely programmable Mixed operation within one circuit is possible Input voltage (Input between L+ and N-) Control input (between L and N) Connected power (output to light) Ambient temperature Dimensions Emergency exit signs Use Material Mounting Options Recognition distance Dimensions U N U DC U N P T a (Module) 230 (+ 10 % / - 15 %) V AC, 50 Hz 175... 275 V DC 230 (+ 10 % / - 15 %) V AC, 50 Hz 4... 100 W - 10... + 50 C L x W x H = 95 x 40 x 32 mm for information and escape sign fittings Foil, self-adhesive, printed with various pictograms in different colours Foil is stuck to cover externally The various types of adhesive foil which can be supplied are detailed in table "Accessories and Spare parts" e = 30 m see dimensional drawings 08480E00 Lighting /5

Accessories and Spare Parts Designation Illustration Description Order number Weight Fluorescent lamps 04936E00 8 W, d 16 mm, for two-pin G5 holder 0.000 Colour of Light flux light cool 450 Im 10 pcs kg 119045 0.415 Socket spanner M8 / wrench size 13; to open/close the central locking 140486 0.126 Adapter plate 05321E00 05755E00 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 115826 0.060 115828 0.060 Emergency exit sign Adhesive foil: size: recognition distance: Colour: Symbol/Text 150 x 355 mm e = 30 m 1 pc 113182 0.015 08483E00 1 pc 113183 0.015 08482E00 1 pc 113184 0.015 08484E00 1 pc 113210 0.015 08485E00 1 pc 113193 0.015 03206E00 1 pc 113200 0.015 12617E00 1 pc 113211 0.015 08486E00 1 pc 113194 0.015 09020E00 1 pc 113201 0.015 12618E00 1 pc 113209 0.015 08487E00 1 pc 113192 0.015 03203E00 1 pc 113199 0.015 12616E00 /6 Lighting

Accessories and Spare Parts Designation Illustration Description Order number Weight Emergency exit sign Adhesive foil: 0.000 size: recognition distance: Colour: Symbol/Text 150 x 355 mm e = 30 m 1 pc kg 113212 0.015 08488E00 1 pc 113195 0.015 12615E00 1 pc 113202 0.015 Diffuser 12619E00 for light fitting 8 W 119044 0.250 05704E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 181 a 4 9 R3,5 425 11 445 7 Additional dimensions for cable entries 8161 and plugs 8290 a (mm) 8161 M25 x 1.5 32 8290 M25 x 1.5 6 119 150 355 04293E00 Emergency exit sign We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be conside binding. 04295E00 Lighting /7