Agilent Technologies. Product Specifications Multiplexer (Option 010/HP 44470A)

Similar documents
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Agilent 8762/3/4A,B,C Coaxial Switches

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

HIGH RELIABILITY POWER SUPPLY TESTING

Microwave Multiplexer Module

Switch Selection Guide

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

HP 8970B Option 020. Service Manual Supplement

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

APPLICATION NOTES POWER DIVIDERS. Things to consider

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Rack mounted telephone- and leased line modem for industrial applications

Modular I/O System Analog and Digital Interface Modules

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

38 Series - Relay interface modules A

MODEL 1211 CURRENT PREAMPLEFIER

SL Series AC and DC Electronic Loads

CMOS 5 V/+5 V 4 Single SPDT Switches ADG619/ADG620

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Agilent E5100A Network Analyzer

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

Experiment 7: Familiarization with the Network Analyzer

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

PRODUCT SPECIFICATION

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Research RF Sputtering Packages

Series CCR-38S/CR-38S Multi-Throw DC 18 GHz/DC-22 GHz Normally Open Coaxial Switch

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Features, Benefits, and Operation

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Model CFA-24 Transparent Cable Farm Automation Switch

NetScanner System. Toronto: , Montreal: , Toll Free: ,

SYSTEM 45. C R H Electronics Design

Temperature & Humidity SMS Alert Controller

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

DCS Series 1 kw, 1.2 kw, & 3 kw

MLC TM Maximum Productivity and Versatility for Control without Compromise!

38 Series - Relay interface modules A

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

iva Cable & Antenna Analyzer

UGF W, 1 GHz, 26V Broadband RF Power N-Channel Enhancement-Mode Lateral MOSFET

Grounding Demystified

Byonics Micro Trak 1000 High Altitude Balloon Tracker

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ MAGNETIC-LATCHING RF RELAY

Kit Watt Audio Amplifier

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

INTELLIGENT INTERACTIVE SYNTHESIZER SURFACE MOUNT MODEL: MFSH

LOXONE 12 Channel Amplifier

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent 8753ET/8753ES Network Analyzers

How To Sell A Talan

How To Use A Sound Card With A Subsonic Sound Card

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

CMOS 5 V/5 V 4 Dual SPST Switches ADG621/ADG622/ADG623

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Compact EGC Amplifier Model 93251

Telephone- and leased line modem for industrial applications TD-36

8 by 8 dot matrix LED displays with Cascadable Serial driver B32CDM8 B48CDM8 B64CDM8 General Description

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

E1-GSM RION ORION TELECOM NETWORKS INC. E1 Channel Bank with 30 X GSM Wireless Interface(s) TELECOM NETWORKS

Schematic Mechanical Drawing Derating Curve. Input. Output. Product Catalogue

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

80 Series - Modular timers 16 A. Features

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

iva Cable & Antenna Analyzer

Ultra640 SCSI Measured Data from Cables & Backplanes

Features. Applications. Truth Table. Close

SMART SENSOR COLLECTION

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

PSC RF Multi SR Six Pack

Electronic Control Devices The European Product Catalogue 2007

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Multi-Range Programmable DC Power Supplies 9115 Series

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Digital Active Indoor Antenna SRT ANT 10 ECO

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Balun Parameter Definitions & Measurement May 2004

2. The Vector Network Analyzer

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

Agilent Test Solutions for Multiport and Balanced Devices

2 CMOS 5 V/5 V, SPST Switches ADG601/ADG602

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

MasterINTERFACE 39 Series - Relay interface modules

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Power Supplies 3. SDN-P DIN Rail Series

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Transcription:

Agilent Technologies Product Specifications Multiplexer (Option 010/HP 44470A) Option 010 is a 10-channel multiplexer for scanning or multiple signal connections. Channels switch 2 wires (Hi and Lo) with 2PST relays for DVM inputs and other signals up to 250V and 2A. This module can also be used to multiplex signals to other switching functions, such as the matrix module. Maximum Voltage: (terminal-terminal or terminal-chassis): 250 V dc, 250 Vac rms, 350 Vac peak Maximum Current: 2A dc, 2 A ac rms Channel Relay Multiplexer (HP 44470D) The Agilent 44470D Relay Multiplexer module provides 20 two-wire channels to switch analog signals to a common bus. The Relays exhibit low thermal offset characteristics, making them ideal for precision low-level measurements. The individual relays on this module are rated for a maximum, open circuit voltage of 250 volts dc or ac rms. Maximum current per relay is 2 amps dc or ac rms and maximum power per relay is 60 watts dc or 125 VA ac. Maximum closed channel resistance is lower than 20HM. The Agilent 44470D can be operated in either a break-before-make (BBM) mode or a mode where multiple channels may be closed together. The Agilent 44470D offers many possible uses, including multiplexer signals directly to a measuring instrument. It can also be used as an input/output multiplexer with the Agilent 44473 Amatrix-option card or other switching configurations. The Agilent 44470D doubles the number of channels of the Agilent 44470A and is compatible with its command set. A new removable terminal block (HP 44480B) is provided for convenience in wiring. Notice: the Agilent 44470D must be used with an upgraded Agilent 3488A Switch/ Control Unit (Agilent 3488A opt. #023). To upgrade an existing Agilent 3488A, order Agilent P/N 44488A. Total Channels: 20 Maximum Voltage: 250V dc or ac rms (terminal-terminal or terminal-chassis) Maximum Current: 2A dc or ac rms (per channel or module) Maximum Power: 60 W dc, 125 VA ac (per channel or module) Overvoltage Transients (max) 1400Vpk differential or single-ended Closed Channel Resistance < 2ohm (end of relay life) Maximum Scan Rate : 43 Channels/sec (Using Agilent 3488A external increment & channel closed, with Agilent 44474A display off) DC Isolation (with one channel closed) Open Channel: < (40ºC, 60% RH): > 10 11 ohm

Channel Channel: < (40ºC, 95% RH): > 5x10 9 ohm Hi-Lo: < (40ºC, 60% RH): > 5x10 10 ohm < (40ºC, 95% RH) > 10 9 ohm Channel - Chassis < (40ºC, 60% RH) > 5x10 10 ohm < (40ºC, 95% RH) > 10 9 ohm Capacitance Open Channel, (with 1 channel closed) Channel - Channel < 7pF Hi - Lo < 27pF Channel - Chassis < 80pF Insertion Loss (db) 100 KHz < 0.2 (with 50 ohm termination) 1 MHz < 0.25, 10 MHz < 1.2 Crosstalk (db) 100 KHz < -73, 1MHz < -53, 10 MHz < -31 General Purpose Relay (Option 01l/HP 44471A) This module consists of 10 SPST independent relays for general signal switching and control of external devices. Quality connections make this module ideal for switching signals when multiplexing is not required, or for supplying switchable power to the device under test. Maximum Voltage (terminal-terminal or terminal-chassis): 250 V dc, 250 Vac rms, 350 Vac peak Maximum Current: 2A dc, 2 A ac rms General Purpose Relay (HP 44471D) The Agilent 44471D General Purpose (GP) Relay module provides 20 independent single pole-single throw (SPST, Form A) switches. The module can find many uses as an actuator assembly. Its low thermal characteristics make it ideal for independent (non-multiplexed) signal switching. The individual relays on this module are rated for a maximum, open circuit voltage of 250 volts dc or ac rms. Maximum current per relay is 1 amp dc or ac rms and maximum power per relay is 60 watts dc or 125 VA ac. Maximum closed channel resistance is lower than 2 Ohm. The Agilent 44471D doubles the number of channels of the Agilent 44471A and the compatible terminal block (HP 44481B) is provided for convenience in wiring. Notice: the Agilent 44471D must be used with an upgraded Agilent 3488A Switch/Control Unit (Agilent 3488A opt. #023). To upgrade an existing Agilent 3488A, order Agilent P/N 44488A.

Total Channels: 20 Maximum Voltage: 250V dc or ac rms (terminal-terminal or terminal-chassis) Maximum Current: 1A dc or ac rms (per channel or module) 20A dc or ac rms Maximum Power: 60 W dc; 125 VA ac (per channel or module) Overvoltage Transients (max) 1400Vpk differential or single-ended Closed Channel Resrstance < 2ohm (end of relay life) Maximum Scan Rate 43 Channels/sec (Using Agilent 3488A external increment & channel closed, with Agilent 44474A display off) DC Isolation (with one channel closed) Open Channel, < (40ºC, 60% RH): > 10 11 ohm Channel - Channel < (40ºC, 95% RH): > 10 9 ohm Channel - Chassis < (40ºC, 60% RH) > 5x10 11 ohm < (40ºC, 95% RH) > 10 10 ohm Capacitance Open Channel, (with 1 channel closed) Channel - Channel < 7pF Hi - Lo < 10pF Channel - Chassis < 25pF Insertion Loss (db) 100 KHz < 0.2 (with 50 ohm termination) 1 MHz < 0.25 10 MHz < 1 Crosstalk (db) 100 KHz < -71 (with 50 ohm termination) 1MHz < -51 10 MHz < -31 VHF Switch (Option 012/HP 44472A) The VHF module provides broadband switching for high-frequency and pulse signals. The two independent groups of bidirectional 1 x4 switches can be used for signals from dc to 300 MHz. All channels have 50-ohm characteristic impedance and are break-before-make within a group of four channels. Each group is isolated from the other and from ground to prevent ground loops. Excellent isolation makes this module ideal for high-frequency signal analyzer measurements requiring a large dynamic range. Maximum Voltage Center-center, center-low: 250 Vdc, 30 Vac rms, 42 Vac peak Low-chassis, low-low: 42 V dc Maximum Current (per channel): 30 ma dc, 300 ma ac rms Thermal Offset: <15 µ V per channel Characteristic Impedance: 50 ohm 30 MHz 100 MHz 300 MHz Crosstalk (db) Channel-Channel <-100 <-85 <-65 Group-Group <-85 <-85 <-50 Insertion Loss (db) <0.5 <0.75 <1.25 VSWR <1.06 <1.12 <1.43

All channels break-before-make within a group of 4 channels. Matrix Switch (Option 013/HP 44473A) Option 013 offers highly flexible switching with a 4x4, 2-wire matrix. Any combination of four input channels maybe connected to any combination of 4 output channels. Each cross point or node in the matrix uses a 2PST relay to switch two lines (Hi and Lo) at a time. Multiple 4 x 4 modules can be connected to form larger matrices. Multiplexer can be used in conjunction with this module to effectively expand the number of inputs and outputs of the matrix. Maximum Voltage (terminal-terminal or terminal-chassis): 250 V dc, 250 Vac rms, 350 Vac peak Maximum Current: 2A dc, 2 A ac rms Digital I/O (Option 014/HP 44474A) This module offers 16 very flexible bidirectional I/O lines and 4TTL-compatible handshake lines for sensing and control of external devices. The digital inputs can be used to sense contact closures to ground. Each channel provides current sinks for remote switching of external relays, such as the Agilent 33311 series coaxial switches. I/O Lines Maximum Voltage: +30 Vdc (line-chassis) Output Characteristics: V (high) >=2.4 V; V (low) <=0.4 V I (low) Maximum: 125 ma @ V (low) <=1.25 V; fused at 250 ma : V (high) >=2 V; V (low) <=0.8 V External Increment: Advances Agilent 3488A to next programmed configuration on falling edge of TTL pulse Channel Closed: Indicates completion of new configuration; TTL pulse Microwave Switch (Option 016/Hp 44476A) This microwave switch furnishes three independent SPST 50-ohm coaxial switches with excellent performance from dc to 18 GHz. The 3.5 mm SMA connector allows you to easily connect cables for multiple system configurations. Frequency Range: DC to 18 GHz Isolation: >90 db Impedance: 50 ohm Insertion Loss: < 0.05 db SWR: 1.40 Form-C Relay (Option 017/HP 44477A) This module provides seven separate SPDT channels for general purpose switching and control of external devices. Using a power supply, the module can drive programmable attenuators and non-hp coaxial switches. Maximum Voltage (terminal-terminal or terminal-chassis): 250 V dc, 250 Vac rms, 350 Vac peak

Maximum Current: 2A dc, 2 A ac rms Microwave Switch (Option 018/HP 44476B) The module brings multi-port 50 ohm coaxial switching to your test system. The module can mount any two Agilent 3331XX coaxial switches. The Agilent coaxial relays come in 3-, 4-, and 5-port configurations-- different switches for a variety of applications. Agilent coaxial switches that can be used are: Agilent Coaxial Switch Port Frequency Agilent 33311B/Opt 011 3 dc to 18 GHz Agilent 33311C/Opt 011 3 dc to 26.5 GHz Agilent 33312B/Opt 011 4 dc to 18 Ghz Agilent 33312 C/Opt 011 4 dc to 26.5 Ghz Agilent 33313B/Opt 011 5 dc to 18 GHz Agilent 33313C/Opt 011 5 dc to 26.5 GHz Microwave Switch Module Refer to Agilent 3331XX product specifications. 1.3 GHz 50 Ohm Multiplexer (Option 019/HP 44478A) 1.3 GHz 75 Ohm Multiplexer (Option 020/HP 44478B) These modules bring bi-directional switching of signals from dc to 1.3 GHz, with high-channel isolation (> 55 db @ 1 GHz). Each module consists of two groups of 1x4 multiplexer. All test connections are made to BNCs on the module?s edge. Off-channels can be resistively terminated. Maximum Voltage: 42 Vdc + ac peak Maximum Current per Channel: 1 A DC or AC rms Maximum Power per Channel: 24 W, 24 VA, or 44 dbm Impedance: 50 ohm (Opt 019/HP 44478A) 75 ohm (Opt 020/HP 44478B) AC Performance <= 10 MHz <= 100 MHz <= 500 MHz <= 1.3 GHz Insertion Loss (db) <= (40º C, 95% RH) <0.3 <0.7 <1.5 <30 <= (25º C, 40% RH), (Typ.) <0.2 <0.5 <1.1 <1.9

Crosstalk (db) Channel-Channel Channel-Common <-90 <-80 <-65 <-55 Group-Group, Module-Module <-90 <-80 <-70 <-60 VSWR <1.2 <1.25 <1.35 <1.55 Breadboard (Option 015/HP 44475A) The breadboard module provides a convenient way to implement custom circuits and special functions that interface directly to the Agilent 3488A backplane control signals.