Thermoluminescence in ultra-high dilution research



Similar documents
SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

WJP, PHY381 (2015) Wabash Journal of Physics v4.3, p.1. Cloud Chamber. R.C. Dennis, Tuan Le, M.J. Madsen, and J. Brown

STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Chapter Test B. Chapter: Measurements and Calculations

Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY

3 - Atomic Absorption Spectroscopy

ESSAY. Write your answer in the space provided or on a separate sheet of paper.

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Mpemba effect from a viewpoint of an experimental physical chemist. by Nikola Bregović

NaCl Lattice Science Activities

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

Temperature. Temperature

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Guidance for Industry

Application Note: Absorbance

ORGANIC SAMPLE PREPARATION

Principle of Thermal Imaging

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

DOSIMETRIC CHARACTERIZATION OF DYED PMMA SOLID DOSIMETERS FOR GAMMA RADIATION

Test Bank - Chapter 3 Multiple Choice

Trace Gas Exchange Measurements with Standard Infrared Analyzers

2 Absorbing Solar Energy

Molecular Spectroscopy

Chemistry Assessment Unit AS 1

Research for leachables of nuclear grade cation exchange resin

SUCRALOSE. White to off-white, practically odourless crystalline powder

CHAPTER 10: INTERMOLECULAR FORCES: THE UNIQUENESS OF WATER Problems: 10.2, 10.6, , , ,

Chemistry 102 Summary June 24 th. Properties of Light

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Year 10 Investigation. What Makes Ice Melt Fastest? By Rebecca Hogan

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

4.2 Bias, Standards and Standardization

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Radiation-Resistant Single-Mode Optical Fibers

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Experiment 6 Qualitative Tests for Alcohols, Alcohol Unknown, IR of Unknown

Sugar or Salt? Ionic and Covalent Bonds

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Practical Applications of Freezing by Boiling Process

Type: Single Date: Kinetic Theory of Gases. Homework: Read (14.1), Do CONCEPT Q. # (1), Do PROBLEMS # (2, 3, 5) Ch. 14

Features of the formation of hydrogen bonds in solutions of polysaccharides during their use in various industrial processes. V.Mank a, O.

4 Thermomechanical Analysis (TMA)

Electromagnetic Radiation (EMR) and Remote Sensing

5s Solubility & Conductivity

The photoionization detector (PID) utilizes ultraviolet

Physical Science 1 Progression

Chapter 5 Classification of Organic Compounds by Solubility

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

Name Class Date. What is ionic bonding? What happens to atoms that gain or lose electrons? What kinds of solids are formed from ionic bonds?

Solid State Detectors = Semi-Conductor based Detectors

Green Heating. Pupil Research Brief. Teachers Notes. Syllabus Coverage Subject Knowledge and Understanding. Route through the Brief UPIL ESEARCHER

Active noise control in practice: transformer station

Recovery of Elemental Copper from Copper (II) Nitrate

CHEMISTRY II FINAL EXAM REVIEW

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

BB-18 Black Body High Vacuum System Technical Description

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

2 Spectrophotometry and the Analysis of Riboflavin

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Experiment #5: Qualitative Absorption Spectroscopy

GIANT FREQUENCY SHIFT OF INTRAMOLECULAR VIBRATION BAND IN THE RAMAN SPECTRA OF WATER ON THE SILVER SURFACE. M.E. Kompan

Indiana's Academic Standards 2010 ICP Indiana's Academic Standards 2016 ICP. map) that describe the relationship acceleration, velocity and distance.

Type of Chemical Bonds

MOISTURE (Karl Fischer, Buffered)

Phys222 W11 Quiz 1: Chapters Keys. Name:

Calculation of Liquefied Natural Gas (LNG) Burning Rates

Chapter 3 Student Reading

Taking Apart the Pieces

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Atomic Calculations. 2.1 Composition of the Atom. number of protons + number of neutrons = mass number

Chemical Bonds. Chemical Bonds. The Nature of Molecules. Energy and Metabolism < < Covalent bonds form when atoms share 2 or more valence electrons.

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Determination of the enthalpy of combustion using a bomb calorimeter TEC

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

Modern Construction Materials Prof. Ravindra Gettu Department of Civil Engineering Indian Institute of Technology, Madras

Chapter 5 Student Reading

A Beer s Law Experiment

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Chapter 2 Measurements in Chemistry. Standard measuring device. Standard scale gram (g)

The Properties of Water (Instruction Sheet)

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

Vacuum Pumping of Large Vessels and Modelling of Extended UHV Systems

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Exp 13 Volumetric Analysis: Acid-Base titration

Mixtures and Pure Substances

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Intravenous Fluid Selection

EXAMPLE EXERCISE 4.1 Change of Physical State

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER

Transcription:

Thermoluminescence in ultra-high dilution research R. van Wijk, S. Bosman and E. P. A. van Wijk Abstract Objective Thermoluminescence of homeopathically prepared ultra-high dilutions of lithium chloride in D 2 O (10-30 g cm -3 ; C15 LiCl in D 2 O) and similarly prepared D 2 O (C15 D 2 O) was compared in three experiments varying a) time between preparation of substance and time of experimentation, and b) time between irradiation and thermoluminescence recording. Data were also compared with a normal solution 0.1 M LiCl in D 2 O and with pure D 2 O. Methods To record thermoluminescence, the solutions were frozen in liquid nitrogen (77K, -196 o C), irradiated with 1kGY, and after a succession of definite storage periods, were progressively rewarmed to 238K (-35 o C). Results Thermoluminescence patterns of C15 LiCl in D 2 O, C15 D 2 O and D 2 O were similar. The average thermoluminescence intensity of C15 LiCl in D 2 O tends to be less than C15 D 2 O when tests were performed shortly after preparation of the substances and with short storage time between irradiation and recording of thermoluminescence. Thermoluminescence of D 2 O was significantly lower than from C15 D 2 O, particularly when the time between irradiation and recording was increased.

170 Thermoluminescence in ultra-high dilution research Conclusion The nature of the phenomena described here still remains unexplained. Nevertheless, data suggest that thermoluminescence might be developed into a promising tool to study homeopathically prepared ultra-high dilutions. Key words Thermoluminescence, deuterium oxide, lithium chloride, homeopathy, ultra-high dilutions. Introduction Thermoluminescence is the emission of light from a substance when it is heated. It is not to be confused with the light spontaneously emitted from a material when it is heated to incandescence. It is the thermally stimulated emission of light following the previous absorption of energy from radiation. Thermoluminescence is a common tool to study the structure of solids, and it has been utilized following irradiation of samples at room temperature and below room temperature for the purpose of dosimetry, age determination, geology or solid-state defect structure analysis (McKeever, 1985). More recently, it has been investigated as future dating technique for icy bodies in the solar system (Yada et al, 2002). Low-temperature thermoluminescence was also utilized to study properties of liquids through turning them into stable solids with the use of very low temperatures (Rey, 2000). Utilizing thermoluminescence, an anomalous effect was observed with ultra-high dilutions of lithium chloride (10-30 g/cm 3 ), prepared in successive steps alternating vigorous mechanical stirring and 1:100 dilution with deuterium oxide. Although theoretically, such dilutions consist of pure deuterium oxide (D 2 O), thermoluminescence was reported to differ from that of pure D 2 O without previously dissolved and diluted lithium chloride (Rey, 2003). Such data resulted in discussions about the memory capacity of ultra-high dilution regarding original salts dissolved initially (Milgrom, 2003).

Introduction 171 D 2 O frozen in liquid nitrogen and then irradiated demonstrated thermoluminescence consisting of Peak 1 near 125 K (-150 o C) and a Peak 2 near 166 K (-107 o C). The two peaks differ in their induction by irradiation (Rey, 2003). Peak 1 luminescence demonstrated an increase greater than 2 orders of magnitude via a dose range between 1 and 20kGy. Peak 2 showed similar thermoluminescence intensity and an increase in intensity via a dose range of 0.02 to 0.4kGy. The two peaks also differ in emission spectrum. The spectrum of the thermoluminescence of Peak 1 was around 350 nm (Peak 1A) and 660 nm (Peak 1B), whereas the spectrum of Peak 2 demonstrated peaks at 450 nm, 485 nm, 525 nm and 575 nm. For the purpose of replicating these observations, however, the study was lacking information regarding a) variability in thermoluminescence of Peak 1 and 2 in identically frozen, irradiated and measured samples, b) time between preparation of sample and its utilization in the experiment, and c) time between irradiation of a sample and measurement of thermoluminescence. The influence of time on thermoluminescence can be twofold. A change, by succussion, in the physical properties of a substance during the preparation of an ultra-high dilution can decrease over time while in storage. A change in the activated state following irradiation can also spontaneously decrease. The present study was an attempt to provide information on these topics. New data were collected for: a) D 2 O, b) 0.1 M lithium chloride in D 2 O, c) ultra-high dilutions of D 2 O prepared by 15 times (C15 D 2 O) a dilution of 100 fold alternated with vigorous mechanical stirring, and d) ultra-high dilution of lithium chloride in D 2 O by 15 times (C15 LiCl) a dilution of 100 fold with D 2 O alternated with vigorous mechanical stirring. Thermoluminescence of these samples was determined a) three weeks after their preparation and with only one week at very low temperature storage between irradiation and recording, b) seven weeks after preparation and with two weeks of storage, and c) twelve weeks after preparation and three weeks of storage.

172 Thermoluminescence in ultra-high dilution research Materials and Methods Materials D 2 O and LiCl were obtained from Sigma-Aldrich, Zwijndrecht, The Netherlands. Bottles, 20 ml, brown glass, hydrolytic Class 2, were utilized untreated from original packaging; all bottles were from the same package. Dilutions were prepared by VSM Geneesmiddelen bv (Alkmaar, The Netherlands) according to a standard protocol. First dilution was prepared by solving 0.1 g lithium chloride (Sigma-Aldrich, Zwijndrecht, The Netherlands) in 9.9 ml of deuterium oxide (D 2 O; Sigma-Aldrich, Zwijndrecht, The Netherlands). Following solutions were made by dissolving 1 (mass) part of the preceding solution in 99 (mass) parts of D 2 O. Each solution was prepared in a new, clean glass bottle. Between each diluting step, the solutions were mechanically succussed (Klinkhamer apparatus), in a vertical direction (100 strokes in 15 seconds). This procedure was repeated until a concentration of 10-30 was reached (C15 LiCl). The control preparation (C15 D 2 O) was prepared according to the same procedure with the exception that the first solution existed of 1 part of D 2 O in 99 parts of D 2 O. Cleaning between potentizing different substances was performed according to Dutch pharmaceutical regulations. The dilutions and the solutions of 0.1 M LiCl in D 2 O and pure D 2 O were stored in tightly closed brown bottles under nitrogen at room temperature. All preparations were made from the same batch of D 2 O and at the same time. The four solutions were utilized throughout the experiment.

Materials and Methods 173 Fig 1: Experimental design of experiments A, B and C, indicating time between preparation of substance (a), freezing (b), irradiation (c) and thermoluminescence measurement (d) Experimental design At three, seven and twelve weeks after preparation, the four substances were utilized in a thermoluminescence experiment. These experiments are indicated as A, B and C, respectively. In each of the three experiments, three samples from each of the four solutions were frozen, irradiated, and analyzed for thermoluminescence. The three samples for all three experiments were taken from the same bottle. Within the same experiment, freezing and irradiation of the twelve samples were performed at the same time. The freezing and irradiation were identical for all 36 samples in the three experiments. Time between irradiation and analysis of thermoluminescence was different in the three experiments (Figure 1). Time of freezing after sample preparation and time between irradiation and measurement were not independently varied in this study, partly because of limitations in capacity.

174 Thermoluminescence in ultra-high dilution research Thermoluminescence recordings in each experiment were carried out within a period of 36 h. Freezing and blinding procedure 1 ml of each solution was placed in aluminum test cups of 20 mm diameter and 2 mm depth and frozen to 253K (-20 o C). Each test cup had a number and the numbers corresponding with each of the four solutions were noted. The frozen samples were kept one day at 253K to achieve stability of the crystallization pattern. Then, the cups were randomly placed by another person on top of each other in two special holders and immersed into liquid nitrogen and maintained at 77K (-196 o C) for one week in a large liquid nitrogen-containing Dewar vessel before irradiation. Samples were maintained in the same ordered arrangement in the liquid nitrogen during irradiation. The sequence of the cups in the holder was essentially unknown until after their thermoluminescence was recorded. The thermoluminescence was recorded by a third person who was not present in any of the previous stages (coding, freezing or irradiation). This person took the samples one after the other from the holder, starting with the upper cup. By recording the number of the cup after the thermoluminescence, it was evident what the sequence in the holder was and which thermoluminescence data corresponded with which of the four solutions. Irradiation Irradiation of the two holders with cups was performed with the Co-60 source Gammacell 220 Excell (GC220E) from MDS Nordion (Fleurus, Belgium). A special Dewar vessel with a size to fit in the radiation chamber was used. The dose selected was 1kGy. The Average dose rate was approximately 30 cgy/sec; irradiation time was 58 min. This dose was selected because it is in the range that thermoluminescence of both Peak 1 and 2 are directly related with the dose (Rey, 2003). The exact absorbed dose distribution in a vertical plane through the central vertical axis of the irradiation chamber is known. After irradiation, all samples were trans-

Materials and Methods 175 ferred into the large liquid nitrogen container for one, two or three weeks before thermoluminescence measurements. Thermoluminescence equipment and procedure Thermoluminescence equipment (JMD electronique, Montelier, France) was equipped with a Statop 4849 temperature controller (Chauvin Arnoux, Vaulx en Velin, France). For each measurement, the Dewar of the thermoluminescence equipment was filled with liquid nitrogen. When the aluminum temperature block had reached 78K, a cup was transferred rapidly to the block and heating was started. The average time to increase the temperature of the block was approximately 20 min before the sensors registered a linear increase of temperature in time. Temperature increase was 6 o C per min from 85K to 235K. Thermoluminescence produced by the sample reached the photomultiplier at a distance of 216 mm utilizing a steel tube with reflecting walls. Photomultiplier The photomultiplier connected to the thermoluminescence equipment was a 9235QB, selected type, photomultiplier in a single-counting mode from Electron Tubes Limited (Ruislip, England). The photomultiplier has a window of 52-mm diameter and a spectral sensitivity range of 200 to 650 nm, allowing optimal detection of Peak 1A and Peak 2. The front ring of the photomultiplier was vented inside, avoiding the condensation of moisture at the quartz window. The photomultiplier was maintained at a temperature of 238K (-25 o C) to reduce the dark current. The dark current during the experimental period was 5.1±0.3 cps.

176 Thermoluminescence in ultra-high dilution research Results D 2 O and solution of 0.1 M LiCl in D 2 O Thermoluminescence between 85K and 235K of 1kGy-irradiated D 2 O resulted first in a small peak at 120K 140K. This was followed by the major emission between 165K and 210K (Figure 2A). The peak at 120K 140K is indicated as Peak 1 and the major emission peak is indicated as Peak 2. Thermoluminescence of 0.1 M LiCl in D 2 O was substantially different from pure D 2 O. Data showed that 0.1M LiCl erased the D 2 O peak. Instead, a strong peak occurred at approximately 110K (Figure 2B). 350000 300000 A Peak 2 250000 D2O Photon counts (/s) 200000 150000 100000 50000 Peak 1 0 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225 235 Temperature (K) Fig 2a: Thermoluminescence of D 2 O solution in D 2 O irradiated at 78K by gamma rays (1kGy)

Results 177 700000 600000 B Photon counts (/s) 500000 400000 300000 200000 LiCl 100000 0 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225 235 Temperature (K) Fig 2b: Thermoluminescence of a 0.1 M LiCl solution in D 2 O irradiated at 78K by gamma rays (1kGy) Table 1: Photon counts in the thermoluminescence Peak 1 (125 150K) and Peak 2 (160 215K) from D 2 O, C15 D 2 O, and C15 LiCl in D 2 O, irradiated at 78K by gamma rays (1kGY). Mean and standard error were determined in three experiments, utilizing three thermoluminescence data sets of each substance per experiment. Counts (x 10 6 ) ± S.E. (x 10 6 ) Peak 1 (125K 150K) Exp D 2 O C15 D 2 O C15 LiCl A 6.01 3.32 4.54 A 4.50 3.61 4.22 A 2.15 4.09 4.14 A 4.22±1.12 3.67±0.22 4.30±0.12 B 10.39 5.34 3.60 B 3.88 9.12 11.77 B 3.48 3.06 6.41 B 5.91±2.24 5.84±1.77 7.26±2.40 C 6.10 11.17 12.50

178 Thermoluminescence in ultra-high dilution research Counts (x 10 6 ) ± S.E. (x 10 6 ) Peak 1 (125K 150K) C 3.12 5.09 6.33 C 4.25 7.50 4.27 C 4.48±0.87 7.92±1.77 7.70±2.47 Counts (x 10 6 ) ± S.E. (x 10 6 ) Peak 2 (160K 215K) Exp D 2 O C15 D 2 O C15 LiCl A 174.72 164.76 38.26 A 49.19 52.75 23.63 A 41.53 63.16 44.98 A 88.48±43.17 93.56±35.73 35.62±6.30 B 35.33 49.63 18.68 B 14.48 46.40 37.20 B 18.37 28.08 58.23 B 22.73±6.40 41.37±6.71 38.04±11.42 C 24.10 110.98 183.69 C 8.55 92.11 54.28 C 9.56 131.83 71.93 C 14.07±5.02 111.64±11.47 103.30±40.52 Ratio Peak 2 / Peak 1 Exp D 2 O C15 D 2 O C15 LiCl A 29.07 49.63 8.43 A 10.93 14.61 5.59 A 19.32 15.44 10.86 A 19.77±5.24 26.56±11.54 8.29±1.52 B 3.40 9.29 5.18 B 3.73 3.16 3.16 B 5.28 9.18 9.08 B 4.14±0.58 7.21±2.03 5.81±1.74 C 3.95 9.94 14.70 C 2.74 18.10 8.58 C 2.25 17.58 16.85 C 2.98±0.51 15.21±2.64 13.38±2.42

Results 179 Effect of succussion The stepwise repetition of succussion and dilution of D 2 O with nonsuccussed D 2 O resulted in C15 D 2 O. Similarly, such stepwise procedure starting with LiCl resulted in potentized LiCl in D 2 O (C15 LiCl in D 2 O). Figure 3 shows the average thermoluminescence patterns of LiCl, D 2 O, C15 D 2 O and C15 LiCl in D 2 O in the experiments A (Figure 3A), B (Figure 3B) and C (Figure 3C). These experiments differed in time after preparation of substances and time between irradiation and analysis of thermoluminescence. In experiment A, samples were tested three weeks after their preparation and with only 1 week storage at 78K, after their radiation. In experiments B and C the samples were tested at seven and twelve weeks after preparation, and with two and three weeks storage at 78K, respectively. Quantitative information including mean and standard error of the counts of thermoluminescence in the different peaks is given in Table 1. Our experiments clearly show that the variability of the Peak 2 thermoluminescence increases with its mean. Consequently, for further statistical analysis we took all data to its logarithm, thus achieving homogenous variances across all conditions and substances. Next, we fitted a two-way analysis of variances (ANOVAs) to the data where the conditions (A, B, or C), the substances (D 2 O, C15 D 2 O and C15 LiCl) and the conditionsubstance interaction were taken as fixed factors. From this model we can conclude that C15 LiCl does not significantly differ from C15 D 2 O in experiments B and C (p = 0.72, and p = 0.63, ANOVA t-tests). In experiment A, there tends to be a difference between both groups (p = 0.059, ANOVA t-test). Moreover, in experiment C D 2 O statistically differs from C15 D 2 O (p<0.0001, ANOVA t-test).

180 Thermoluminescence in ultra-high dilution research 700000 600000 A Photon counts (/s) 500000 400000 300000 200000 LiCl C15 D2O 100000 D2O C15 LiCl 0 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225 235 Temperature (ºK) Fig 3a: Thermoluminescence of 0.1 M LiCl in D 2 O, D 2 O, C15 LiCl in D 2 O, and C15 D 2 O, irradiated at 78K by gamma rays (1kGy). Freezing was three weeks after preparation of substances; very low temperature storage for one week occurred between irradiation and recording. 500000 400000 B Photon counts (/s) 300000 200000 100000 LiCl C15 LiCl C15 D2O 0 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225 235 Temperature (ºK) Fig 3b: Thermoluminescence of 0.1 M LiCl in D 2 O, D 2 O, C15 LiCl in D 2 O, and C15 D 2 O, irradiated at 78K by gamma rays (1kGy). Freezing was seven weeks after preparation; storage between irradiation and recording was two weeks. D2O

Discussion 181 700000 600000 C 500000 Photon counts (/s) 400000 300000 200000 LiCl C15 D2O D2O C15 LiCl 100000 0 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225 235 Temperature (ºK) Fig 3c: Thermoluminescence of 0.1 M LiCl in D 2 O, D 2 O, C15 LiCl in D 2 O, and C15 D 2 O, irradiated at 78K by gamma rays (1kGy). Freezing was twelve weeks after preparation; storage between irradiation and recording was three weeks. It has been suggested that Peak 2 could be connected to the hydrogen-bond network within the ice, while Peak 1 is closely related to the molecule (Rey, 2003). To compare Peak 2 counts for the different conditions and substances, the emitted light in Peak 2 can also be normalized taking Peak 1 as the reference. The ratio Peak 2/ Peak 1 is shown in Table 1. In doing so, we were able to conclude that in the two-way ANOVA t-test there was a significant difference between LiCl C15 and C15 D 2 O in experiment A (p = 0.0128), but not in experiment B and C (p = 0.60 and 0.73, respectively). In experiment C D 2 O statistically differs from C15 D 2 O (p<0.0004). Discussion We report here differences in thermoluminescence between C15 D 2 O and C15 LiCl, which correspond with the observations reported by Rey (2003). However, the difference from all of these recordings of these substances

182 Thermoluminescence in ultra-high dilution research was not statistically significant. The present data suggest that such difference tended to be significant only when the experiment was carried out three weeks after preparation of the substances and with a short time between irradiation and thermoluminescence recording. Another observation in the present study was the difference in thermoluminescence between C15 D 2 O and D 2 O. Data suggest an increased difference during long storage conditions. We can only speculate about the significance of the observed opposite trends. Given that the original pure D 2 O had not been modified and was also the basis for the preparation of succussed ultra-high dilutions, it is proposed that it would not be additionally activated after irradiation in the experiments carried out at 3, 7 and 12 weeks after its use for the preparation of the succussed ultra-high dilutions. It is more likely that the obvious thermoluminescence decreasing trend of D 2 O compared to C15 D 2 O under long storage conditions suggests the possibility that stored irradiation energy in D 2 O might be more easily released at very low temperatures. Be that as it may, it appears that the structural state of a solution made in D 2 O can be modified by strong succussion. The explanation of the trend observed in the difference between C15 D 2 O and C15 LiCl might be just the opposite. It has been proposed that LiCl suppresses hydrogen bonds. With such strong hydrogen bond suppression as a ghost effect after succussion in the ultra-high dilution, one can imagine that it is more likely to be present shortly after preparation. Such a ghost effect would be lost after a long storage of the substance. With this in mind, the hypothesis to explain the data include a) succussion stabilizes the D 2 O physical structure in such a way that stored radiation energy can be kept for a longer period, and b) the ghost effect of LiCl after preparation interferes with this stabilization process, but only for a limited time. The nature of the phenomena here described still remains unexplained. Generally, liquid water is described as a disordered ensemble of highly polar molecules linked through a fluctuating network of intermolecular hydrogen bonds. Recent studies demonstrated the efficiency of energy redistribution within the hydrogen-bonded network, and that water loses the memory of persistent correlations in its structure within 50 fs (Cowan et al, 2005). Energy-transfer dynamics studies of a water molecule that is enclosed by acetone molecules, has demonstrated hydrogen bond dynamics with time constant of 1.3 ps (Gilijamse et al, 2005). This means that the

Discussion 183 exact nature of the phenomena presented in this paper is not, at present, in agreement with current theories on the fluctuations in the network of intermolecular hydrogen bonds. It is evident that the results need further study. The point must be stressed that we obtained a very good qualitative reproducibility of the thermoluminescence pattern, but the quantitative reproducibility was rather poor, and p-values should be interpreted in the sense of descriptive statistics. Subsequent sample size calculations show that 18 Peak 2 measurements (9 with each group) were needed to detect a difference between C15 LiCl and C15 D 2 O with a power of 90%. The variation between samples can only partially be explained by the time between substance preparation and testing, and/or time between irradiation and recording. The variation is slightly reduced if we normalized the emitted light readings in Peak 2 utilizing Peak 1 as the reference (Rey, 2003). To study the origin of the fluctuations within one set of data, we have looked at the following variables: a) Filling the cups was kept constant. The thermoluminescence was not correlated filling the cups sequence or placing them in the freezer. b) The samples were frozen under similar conditions. c) The procedure for irradiation was constant. The location of the cups inside the irradiation chamber was compared with the absorbed dose-distribution in the irradiation chamber, and no correlation was observed between the location in the chamber and the luminescence recorded. d) The procedure for recording thermoluminescence was kept constant. Although some variation was observed in time before temperature increased linearly, this linear increase always began when the temperature was at approximately 87K, demonstrating no correlation with the differences in luminescence intensity. Comparing all these steps in the experimental protocol, it can be suggested that the freezing process causes the variation in thermoluminescence. It is well known that in this process, variations arise as they do in ice crystallization patterns. Yada et al (2002) observed that Peak 2 is extremely dependent upon oxygen content. Further studies are required to study the role of oxygen in the variation.

184 Thermoluminescence in ultra-high dilution research Conclusions In summary, the present data suggest that the thermoluminescence technique can contribute to the challenge of succussion and ultra-high dilution preparation procedures commonly applied to homeopathic medication preparation. In order to improve the protocol, our data suggest further research utilizing a large number of observations to include a) different time periods between the preparation of substances and their use in an experiment, and b) different time periods between irradiation and thermoluminescence registration. If such protocol were to be developed, it could be utilized to compare different procedures currently used in homeopathic pharmaceutical practice. References Chen R, McKeever SWS. Theory of Thermoluminescence and Related Phenomena. Singapore: World Scientific, 1997, 1 559. Cowan ML, Bruner BD, Huse N, Dwyer JR, Chugh B, Nibbering ETJ, Elsaesser T, Miller RJD. Ultrafast memory loss and energy redistribtion in the hydrogen bond network of liquid H 2 O. Nature 2005; 434: 199 202. Gilijamse, J.J., Lock, A.J., Bakker, H.J., Dynamics of confined water molecules, Proc. Natl. Acad. Sci. USA 102 (2005) 3202 3207. McKeever SWS. Thermoluminescence of Solids. Cambridge: University Press, 1985, 1 376. Milgrom LR. The memory of water regained? Homeopathy 2003; 92: 223 224. Rey LR. Thermoluminescence de la glace. C.R. Physique 2000;1: 107 110. Rey LR. Thermoluminescence of ultra-high dilutions of lithium chloride and sodium chloride. Physica A 2003; 323: 67 74. Yada T, Norizawa K, Hirai M, Yamanaka C, Ikeya M. Optically stimulated luminescence study on γ-irradiated ice frozen from H 2 O and D 2 O. Jpn. J. Appl. Phys. 2002; 41: 5874 5880.

Acknowledgements 185 Acknowledgements We would like to thank the Karl and Veronica Carstens-Foundation for financial support, and VSM Geneesmiddelen B.V. for preparation of test solutions. Dr. Roeland van Wijk, Dr. Saskia Bosman and Dr. Eduard P.A. van Wijk Corresponding author: Dr. Roeland van Wijk, International Institute of Biophysics, Raketenstation Hombroich, Kapellener Straße, 41427 Neuss Aus: The Journal of Alternative and Complementary Medicine 2006; 12 (5), 437 443 (Mary Ann Liebert, Inc)