Orbital Reconstruction. Solutions for treating orbital fractures.

Similar documents
Titanium Wire with Barb and Needle. For canthal tendon procedures.

Cranial/Neurosurgical Implants

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

MatrixNEURO CMF Matrix

PSI Patient Specific Implants. Derived from CT data for excellent reconstructive results.

PERIPROSTHETIC IMPLANTS

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Scout Vessel Guard. A hydrogel membrane with exceptional handling characteristics.

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

TriLock 1.5 Implants for the Phalanges

How To Fix A Radial Head Plate

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

MatrixNEURO. The next generation cranial plating system.

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Battery Power Line. Battery-driven power tool system for orthopaedics and traumatology.

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Small Battery Drive. For orthopaedic trauma applications.

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Dental Implant Options in Atrophic Jaws

Lentur Cable System. Surgical Technique

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

Zimmer Small Fragment Universal Locking System. Surgical Technique

Knotilus TM. Anchor Instability Repair. Technique Guide

ARCS Pre-Implantology

Tissue Reinforcement with Strattice Reconstructive Tissue Matrix following Correction of Severe Breast Deformity

Product Catalogue Edition

esims Web Overview. Synthes Information Management Suite.

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

The information contained in this document is intended for healthcare professionals only.

CeSpace Titanium / PEEK

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Zimmer DeNovo NT Natural Tissue Graft

Standard Internal Hex

Zimmer Periarticular Proximal Tibial Locking Plate

V-TEK IVP System 2.7 System 4.0

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Zimmer Periarticular Elbow Locking Plate System

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Products for. the Oral and Maxillofacial Surgeon CMF

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

Acetabular Wedge Augment System

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

Shoulder Restoration System

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Double Bone Plug Meniscus Reconstruction Surgical Technique

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

Traumatic Primary Eyelid and Facial Laceration Repair. Riva Lee Asbell Philadelphia, PA

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

FREEBIRD THE ORIGINAL D.I.Y. ORNITHOPTER! Tools and Glue. Required Materials

NCB Distal Femur System. Surgical Technique

Degenerative Spine Solutions

Achilles Tendon Repair, Operative Technique

Forming the Interface Between Doctor and Designing Engineer

Minimally Invasive Hip Replacement through the Direct Lateral Approach

IMPLANT DENTISTRY EXAM BANK

How To Use A Phoenix Retrograde Femoral Nail

TwinFix Cannulated Compression Screw

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Product Reference Guide

Neuro Closure C A T A L O G

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

Product Catalogue 2013

Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

Abdominal Pedicle Flaps To The Hand And Forearm John C. Kelleher M.D., F.A.C.S.

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Malleolar fractures Anna Ekman, Lena Brauer

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

MEDICAL TECHNOLOGY IN IMPRESSIVE 3D

Ventral Hernia Repair

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

Titanized Mesh Implants Hernia Surgery

IMPLANT MENTOR PROGRAM

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC

IVALON Ophthalmic. IVALON Ophthalmic Products

Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.

(English) NEXUS SPINE SPACER SYSTEM

HUNTER TENDON IMPLANTS

Selection & Use of Surgical Needles

Bone augmentation procedure without wound closure

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

LCP Compact Foot/Compact Hand.

Don t Let Life Pass You By Because Of Oral Bone Loss

Transcription:

Orbital Reconstruction. Solutions for treating orbital fractures. Extensive orbital defects Isolated blow-out fractures Canthal tendon surgery

Titanium Orbital Mesh Plates Orbital Floor Mesh Plates Recommended for all types of orbital fractures and reconstruction of the bony orbit. Features Radial design simplifies cutting Malleable material facilitates contouring Three rows of screw holes provide a variety of fixation points to adapt to orbital anatomy Available in 0.2 mm, 0.3 mm and 0.4 mm thicknesses Available for use with 1.0 mm or 1.3 mm titanium screws Universal design for either right or left orbit Manufactured from commercially pure (CP) titanium Available sterile or nonsterile Orbital Mesh Plates 1.0 mm 1.3 mm Color 420.302 421.302 0.2 mm Purple 420.303 421.303 0.3 mm Teal 420.304 421.304 0.4 mm Gold Enlarged view These implants are available nonsterile or sterile-packed. Add S to product number for sterile product. Synthes

Titanium Anatomic Orbital Floor Plates Features Microperforation design minimizes tissue ingrowth Three configurations address large or small defects Anatomic design minimizes cutting Universal configuration can be used in left or right orbit Radial reliefs simplify contouring Malleable, 0.3 mm thick material facilitates anatomic adaptation Multiple screw holes provide a variety of fixation points Available for use with 1.0 mm or 1.3 mm titanium screws Manufactured from commercially pure (CP) titanium Available sterile or nonsterile Anatomic Orbital Floor Plate, small Recommended for small isolated orbital floor fractures. Anatomic Orbital Floor Plate, small Anatomic Orbital Floor Plate, medium Recommended for large orbital floor fractures. Anatomic Orbital Floor Plate, medium Anatomic Orbital Floor Plate, large Recommended for orbital floor defects with medial and lateral wall involvement and reconstruction of tumor resections Medial wing clears lacrimal duct M-shaped cutout designates medial wing Anatomic Orbital Floor Plate, large 2 Synthes Orbital Reconstruction

Anatomic Orbital Floor Plates 1.0 mm 1.3 mm Small 420.401 421.048 0.3 mm Medium 420.403 421.043 0.3 mm Large 420.402 421.049 0.3 mm Universal Orbital Floor Plates and Medial Wall Plates 1.0 mm Universal 420.40 0.4 mm Medial Wall L 420.44 0.5 mm Medial Wall R 420.45 0.5 mm 1.3 mm Universal 420.40 0.4 mm Medial Wall L 420.44 0.5 mm Medial Wall R 420.45 0.5 mm 1.5 mm Universal 446.40 0.6 mm Medial Wall L 446.44 0.6 mm Medial Wall R 446.45 0.6 mm Universal Orbital Floor Plate Medial Wall Plate These implants are available nonsterile or sterile-packed. Add S to product number for sterile product. Orbital Reconstruction Synthes 3

1.3 mm and 1.5 mm Titanium Contourable Mesh Plates Features Plates are easily contoured without kinking to match the irregular craniofacial anatomy Malleable and rigid mesh are available for most craniofacial repair and reconstruction indications Available for use with 1.3 mm or 1.5 mm titanium screws Made from commercially pure (CP) titanium Available in a variety of shapes: rectangular, round and arc Contourable Mesh Plates Malleable, rectangular 421.004 1.3 mm, 38 mm x 45 mm 0.4 mm 421.007 1.3 mm, 100 mm x 100 mm 0.4 mm 446.014 1.5 mm, 38 mm x 45 mm 0.4 mm 446.017 1.5 mm, 100 mm x 100 mm 0.4 mm Rigid, rectangular 421.005 1.3 mm, 38 mm x 45 mm 0.6 mm 421.008 1.3 mm, 100 mm x 100 mm 0.6 mm 421.009 1.3 mm, 200 mm x 200 mm 0.6 mm 446.015 1.5 mm, 38 mm x 45 mm 0.6 mm 446.018 1.5 mm, 100 mm x 100 mm 0.6 mm 446.019 1.5 mm, 200 mm x 200 mm 0.6 mm Rectangle Malleable Mesh Rigid Mesh These implants are available nonsterile or sterile-packed. Add S to product number for sterile product. 4 Synthes Orbital Reconstruction

Contourable Mesh Plates continued Malleable, arc 421.011 1.3 mm, small 0.4 mm 421.012 1.3 mm, large 0.4 mm 446.033 1.5 mm, small 0.4 mm 446.034 1.5 mm, large 0.4 mm Rigid, arc 421.013 1.3 mm, small 0.6 mm 421.014 1.3 mm, large 0.6 mm 446.035 1.5 mm, small 0.6 mm 446.036 1.5 mm, large 0.6 mm Arc Malleable, round 421.015 1.3 mm, 30 mm diameter 0.4 mm 421.016 1.3 mm, 70 mm diameter 0.4 mm 421.017 1.3 mm, 100 mm diameter 0.4 mm 446.050 1.5 mm, 30 mm diameter 0.4 mm 446.051 1.5 mm, 70 mm diameter 0.4 mm 446.052 1.5 mm, 100 mm diameter 0.4 mm Rigid, round 421.018 1.3 mm, 30 mm diameter 0.6 mm 421.019 1.3 mm, 70 mm diameter 0.6 mm 421.020 1.3 mm, 100 mm diameter 0.6 mm 446.053 1.5 mm, 30 mm diameter 0.6 mm 446.054 1.5 mm, 70 mm diameter 0.6 mm 446.055 1.5 mm, 100 mm diameter 0.6 mm Round Malleable Mesh Rigid Mesh These implants are available nonsterile or sterile-packed. Add S to product number for sterile product. Orbital Reconstruction Synthes 5

SynPOR Titanium Reinforced Fan Plates SynPOR Titanium Reinforced Fan Plates Porous sheet embedded with the Synthes fan-shaped 1.3 mm titanium orbital floor plate. SynPOR Smooth Titanium Reinforced Fan Plates Porous sheet embedded with the Synthes fan-shaped 1.3 mm titanium orbital floor plate. SynPOR Smooth Titanium Reinforced Fan Plates provide a barrier to minimize soft tissue adhesion on the superior surface and a porous surface on the reverse side to support tissue in-growth. Radiographic visibility Increased sheet strength and contour retention Available with titanium mesh partially exposed or completely covered for multiple fixation options Anatomical shape and radial titanium mesh design minimize cutting Polyethylene sheets reduce sharp titanium edges after cutting and facilitate insertion Fixation hole positions allow optimal screw placement Available in two thicknesses: 0.8 mm and 1.5 mm Compatible with 1.3 mm titanium screws Technique tip: For smooth implants, place the smooth side of the implant toward the soft tissue to minimize adhesion and ensure motility of the globe. SynPOR Titanium Reinforced Fan Plate SynPOR Titanium Reinforced Fan Plate, with exposed fixation holes SynPOR Titanium Reinforced Fan Plates, sterile 08.520.120S 0.8 mm thick 08.520.121S with fixation holes, 0.8 mm thick 08.520.130S 1.5 mm thick 08.520.131S with fixation holes, 1.5 mm thick SynPOR Smooth Titanium Reinforced Fan Plates, sterile 08.520.220S 0.8 mm thick 08.520.221S with fixation holes, 0.8 mm thick 08.520.230S 1.5 mm thick 08.520.231S with fixation holes, 1.5 mm thick SynPOR Smooth Titanium Reinforced Fan Plate SynPOR Smooth Titanium Reinforced Fan Plate, with exposed fixation holes 6 Synthes Orbital Reconstruction

SynPOR Porous Polyethylene Sheets Features Porous structure supports tissue ingrowth Smooth implants have one barrier surface allowing tissue ingrowth on only one side Nonabsorbable and biocompatible material Semirigid material is strong yet flexible Contourable and easily shaped Implants may be fixated with screws, tacks, wire, or suture SynPOR Porous Polyethylene Sheets, sterile SynPOR porous polyethylene sheets are well-suited for craniofacial reconstruction and augmentation. Open, interconnected pores permeate the material and support fibrovascular tissue ingrowth. SynPOR Sheets Engineered to maintain an open interconnected porosity throughout the implant to support tissue ingrowth. SynPOR Smooth Sheets Implants have a thin layer of solid polyethylene on the superior surface to minimize tissue adhesion and porous polyethylene on the inferior surface to support tissue ingrowth. Synthes 7

SynPOR Porous Polyethylene Sheets SynPOR Porous Polyethylene Sheets, sterile 08.510.110S 50 mm x 50 mm 0.45 mm thick 08.510.120S 50 mm x 50 mm 0.8 mm thick 08.510.130S 50 mm x 50 mm 1.5 mm thick 08.510.140S 50 mm x 50 mm 3.0 mm thick SynPOR Smooth Square Sheets, sterile 08.510.220S 50 mm x 50 mm 0.8 mm thick SynPOR Square Sheet SynPOR Smooth Square Sheet SynPOR Orbital Floor Plates, sterile 08.510.540S 24 mm 0.8 mm thick 08.510.541S 30 mm 0.8 mm thick 08.510.542S 35 mm 0.8 mm thick 08.510.543S 24 mm 1.5 mm thick 08.510.544S 30 mm 1.5 mm thick 08.510.545S 35 mm 1.5 mm thick SynPOR Smooth Orbital Floor Plates, sterile 08.510.640S 24 mm 0.8 mm thick 08.510.641S 30 mm 0.8 mm thick 08.510.642S 35 mm 0.8 mm thick SynPOR Orbital Floor Plate SynPOR Fan Plate SynPOR Fan Plates, sterile 08.510.546S 35 mm radius 0.8 mm thick 08.510.547S 35 mm radius 1.5 mm thick SynPOR Smooth Fan Plates, sterile 08.510.646S 35 mm radius 0.8 mm thick 8 Synthes Orbital Reconstruction

Resorbable Plates Features Implants are fully resorbable Radiolucent in x-ray, MRI, and CT Scan Eliminates secondary surgery for implant removal Resorbable Orbital Floor Plates, sterile Recommended for orbital floor fractures. Indications Synthes Rapid Resorbable Fixation System is intended for use in fracture repair and reconstructive procedures of the craniofacial skeleton in pediatric and adult populations. In addition, resorbable meshes, sheets, screws and tacks may be used in non-load-bearing applications for maintaining the relative position of, and/or containing, bony fragments, bone grafts, (autograft or allograft), or bone graft substitutes in reconstruction of the craniofacial or mandibular areas. 1.5 mm Resorbable Orbital Floor Plate, sterile Color 821.540.01S 24 mm x 24 mm 0.5 mm Transparent 1.5 mm Rapid Resorbable Orbital Floor Plates with Bending Template 851.689.01S 24 mm x 24 mm 851.690.01S 30 mm x 30 mm 851.691.01S 35 mm x 35 mm 24 mm 24 mm 1.5 mm Rapid Resorbable Orbital Floor Plates, sterile Color 851.540.01S 24 mm x 24 mm 0.5 mm Transparent 851.541.01S 30 mm x 30 mm 0.5 mm Transparent 851.542.01S 35 mm x 35 mm 0.5 mm Transparent Bending Templates for 1.5 mm Resorbable Orbital Floor Plates 329.632 24 mm 0.25 mm 329.633 30 mm 0.25 mm 329.634 35 mm 0.25 mm Synthes 9

Titanium Wires Features Manufactured from commercially pure titanium Compatible with titanium bone fixation systems Minimal MRI scatter Four gauges available: 26, 28, 30, and 32 gauge Convenient and easy handling Accommodate a variety of surgical techniques Indications Synthes Titanium Wire and Titanium Wire with barb and needle is indicated for use in soft tissue approximation and/or ligation, for canthoplasty, canthopexy, and/or canthal tendon repair. Titanium Wires, with needle, 500 mm, sterile 493.100.01S 26 Gauge (0.4 mm diameter) 493.101.01S 28 Gauge (0.31 mm diameter) 493.102.01S 30 Gauge (0.25 mm diameter) 493.103.01S 32 Gauge (0.2 mm diameter) Titanium Wire, with barb and needle, 500 mm, sterile 493.104.01S 28 Gauge (0.31 mm diameter) 10 Synthes Orbital Reconstruction

Synthes CMF 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.synthes.com 2003 Synthes, Inc. or its affiliates. All rights reserved. SynPOR and Synthes are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 2/12 J4525-D