4 inputs for standardized signal measuring 0 10 V, 0 20 ma, 4 20 ma. Communication via RS232 or RS485 lines

Similar documents
Modular I/O System Analog and Digital Interface Modules

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

IO-DIM6 6-Channel, Digital to Analogue Converters

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

T0118 T2118 T3118. Instruction Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

Inwall 4 Input / 4 Output Module

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Designing VM2 Application Boards

Vibration Monitoring System Adash 3600

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Install the DeviceNet Module using the following procedure:

Temperature & Humidity SMS Alert Controller

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Digital input modules

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

USER MANUAL V5.0 ST100

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Disturbance Recoder SPCR 8C27. Product Guide

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

M2M/IoT Solutions.

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Installation Manual for D0700 ISDN Analogue Converter

NC-12 Modbus Application

Digital Keypad Use s Manual

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Setup guide. point to point wall plate extenders

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

User manual Compact Web PLC WP240 series IEC-line

EVAL-UFDC-1/UFDC-1M-16

Technical description MX-1 VB Edge

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

DALI RC BASIC SO. Control unit Operating instructions

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Application/Connection Examples

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Multifunction devices

PCS0100en Persy Control Services B.V. Netherlands

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Impedance 50 (75 connectors via adapters)

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

TX OPEN RS232/485 module

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

L5354 ControlNet Communications Interface

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Documentation. M-Bus 130-mbx

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

1. SAFETY INFORMATION

is then retained absolutely without interruption.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

EDI Distributor Control Interface Wiring and Setup Instructions

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

PD 100A. Printing data system

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

MOTION COORDINATOR MC206X Quick Connection Guide

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Contents. Document information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15 TUTORIAL OUTCOME 2 Part 1

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Transmitter Interface Program

SYSTEM 4C. C R H Electronics Design

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Advanced Data Capture and Control Systems

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

Instruction Manual. T3111 T3111L T3111P T3111Ex

AUTODIALLER / QUICKDIALLER - SA132

Table of Contents. Creating a VC1000 Network... 3

Current Monitoring Kit QUICK START GUIDE

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

DMX2PWM 9 Channel Dimmer Setup Manual

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Danfoss Link Mobile Phone Butler

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Transcription:

Measuring converter 4 inputs for standardized signal measuring 0 10 V, 0 20 ma, 4 20 ma Communication via RS232 or RS485 lines 15. June 2009 w w w. p a p o u c h. c o m 0294.01.02

Datasheet Created: 4.5.2007 Last update: 6/15/2009 10:17 AM Number of pages: 12 2009 Address: Strasnicka 3164 102 00 Prague 10 Czech Republic Tel: +420 267 314 267 +420 267 314 268 +420 602 379 954 Fax: +420 267 314 269 Internet: E-mail: info@papouch.com Page 2

CONTENT Basic information... 4 Description... 4 Application... 4 Features... 4 Block diagram and operation... 5 Examples of connection structure... 5 Voltage measurement... 5 Sensors with output of 0 to 20 ma and own power supply... 6 Sensors with output of 0 to 20 ma, supplied through current loop... 6 Connectors... 7 Measuring terminals... 7 Power supply... 8 RS232... 8 RS485... 9 Technical parameters... 10 Available Designs... 11 Indications... 11 Detailed description of communication protocol... 11 Page 3

BASIC INFORMATION D e s c r i p t i o n measuring converter is a 4-input A/D converter which enables the user to measure to four current inputs ranging from 0(4) to 20 ma or voltage between 0 and 10 V. The measured values are then transferred to a superior system in digital form. has been produced in three versions differing in their communication interface the data can be transferred via RS232/RS485 lines, over USB interface or the Ethernet. The version communicates via RS232 serial line or RS485 bus. A p p l i c a t i o n Measurement of values from sensors with voltage or current output. Reading of sensors whose output is a standardised current signal Digitalisation of measured values from level, pressure, temperature, distance and other sensors F e a t u r e s Four analogue inputs for current or voltage Measuring scale divided into 10 000 divisions Full isolation of the measuring part from power supply and communication lines Measurements carried out by a multiplex 16 bit sigma-delta A/D converter The maximum measuring speed of each input equals 406 ms Two measuring modes: o Single measurement sends one measured value from each input upon a request. o Continuous measuring measures all inputs in the set interval and regularly sends the measured values via the communication line. Communication via RS232 (COM port) or RS485 (industrial bus) Measuring Wix software for temperatures displaying and storing for Windows Wide range of power supply voltage (6 to 30 V) Page 4

BLOCK DIAGRAM AND OPERATION The measuring part is fully isolated from the communication line and power supply. Fig. 1 Block diagram of The measuring device uses one switched sigma-delta A/D converter. After switching on the power supply voltage, the processor initiates the A/D converter and set the device parameters according to the data saved in memory. Then the device start to regularly measure the values of voltage found on the analog inputs and saves the results into the integrated memory. In the continuous measuring mode sends the measured values in the set interval. EXAMPLES OF CONNECTION STRUCTURE The following figures show examples of connection structure. V o l t a g e m e a s u r e m e n t An example of voltage supply connection to terminals. The inputs are fully isolated from the power supply. Fig. 2 Voltage measurement Page 5

S e n s o r s w i t h o u t p u t o f 0 to 2 0 m A a n d o w n p o w e r s u p p l y Sensors with currents outputs can be connected directly to the inputs with current range and supplied either from their own power supply (in this case, the sensor is isolated from power supply) or from the same supply as (see the dashed lines in Fig. 3; in this case, sensors are not isolated). Fig. 3 Current sensors with their own power supply S e n s o r s w i t h o u t p u t o f 0 to 2 0 m A, s u p p l i e d t h r o u g h c u r r e n t l o o p With a separate source for sensors In this case, the sensors are isolated from power supply. Fig. 4 Current sensors with separate supply through current loop Page 6

With a joint source for sensors and In this case, the sensors are isolated with power supply. Fig. 5 Current sensors supplied through current loop from joint source with CONNECTORS M e a s u r i n g t e r m i n a l s Note: The input types (voltage or current) are unchangeable and must be specified by the user when ordering the device. Subsequently they can be changed only by the manufacturer.. The measuring terminal unit is a six-slot terminal unit shown in Figure 6. It contains four inputs and two grounding terminals. All four measuring terminals have a joint grounding on the two sides of the terminal unit. This grounding is isolated from other grounding terminals found in the device. The measuring terminals have been designed for the measurement of voltage of current. Wires can be connected individually and fixed by means of a screw (use flat bladed screwdriver 2.5 mm). Fig. 6 Terminals for power supply connection and measuring terminals Page 7

P o w e r s u p p l y DC supply 6 to 30 V shall be connected to the double terminal shown in Fig. 6. The input has an integrated polarity reversal protection. Wires can be connected individually and fixed by means of a screw (use flat bladed screwdriver 2.5 mm). R S 2 3 2 RS232 serial line shall be connected via the CAN9F connector (female plug). A usual extension cable is suitable for RS232 connection. The serial line connector is shown in Fig. 7, the connection diagram for individual conductors can be found in Fig. 8. A simultaneous use of RS232 and RS485 as communication interfaces is possible. is able of receive commands only from one line at a time. It is necessary to make sure does not receive commands from both RS232 and RS485 simultaneously. Fig. 7 Terminals for RS232 and RS485 1 serial lines connection Fig. 8 RS232 connector diagram 1 RS485 line conductors are often marked as A (RxTx+) and B (RxTx-). Page 8

R S 4 8 5 The connection to RS485 bus can be made by means of the terminal next to the Cannon connector. The terminal connection is shown in Fig. 7. A simultaneous use of RS485 and RS232as communication interfaces is possible. is able of receive commands only from one line at a time. It is necessary to make sure does not receive commands from both RS485 and RS232 simultaneously. Connection of RS485 termination It is not necessary to use the termination in most cases. However, if the RS485 communication line runs through interfering environment (it runs in parallel with power conductors etc.) it is suitable to connect the termination. There can be only up to 2 modules with connected termination on one line (at the opposite ends of the line). Inside the device can be found a jumper which can be shorted out to connect the termination (see Fig. 9). The housing can be opened after unscrewing the screws on the sides. Fig. 9 Jumper for RS485 termination Page 9

TECHNICAL PARAMETERS Analogous inputs: Number of inputs... 4 Input type... unipolar Voltage input range... 0 10 V; 10 000 divisions Input impedance (voltage inputs)... 1 MΩ (100 kω / 1 V) Current input ranges... 0 20 ma; 4 20 ma; 10 000 divisions Calibration... 10 000 divisions/range A/D converter resolution... 16 bits Maximum non-linearity... 10 divisions Maximum zero error... 10 divisions Maximum rang error... 10 divisions Maximum measuring speed... 406 ms (all channels) Calibration method... software 2 Control interface: Type... RS232 and RS485 Connector... slip-on terminal unit Communication speed... adjustable 300 Bd to 230.4 kbd (default: 9.6 kbd) Number of data bits... 8 Parity... no parity Number of stop-bits... 1 Isolation... ± 300 V Communication protocol... Spinel Minimum response delay... 2 ms 3 Power supply: Supply voltage... DC 6 to 30 V (with polarity reversal protection) Power consumption... usually 30 ma at 12 V Other parameters: Operation temperature... -20 C to +70 C Dimensions... 104 mm 55 mm 24 mm Dimensions incl. connectors... 121 mm 55 mm 24 mm Dimensions incl. DIN rail holder... 104 mm 55 mm 33 mm 2 Calibration is described in greater detail in the communication protocol description which is available to be downloaded from the device web page. 3 Due to the delay when switching the communication direction over to RS485. Page 10

Weight... 145 g A v a i l a b l e D e s i g n s Assembly: Without a holder (standard design) With a DIN rail holder Input ranges: 0 to 10 V 0 to 20 ma 4 to 20 ma It is possible to deliver another current or voltage range upon request; it is also possible to combine more ranges in one device Fig. 10 - with DIN rail holder With a wall holder Fig. 11 AD4 with wall holder Do not hesitate to contact us in case of any other special requirements concerning the module design and functions. INDICATIONS The device contains three light indicators showing the operational status: ON Green light. Lights when the supply voltage is connected. COM Yellow light. Flashes once after the device initiation following the power supply switch-on and also during communication running on RS232 or RS485. OVR Red light. Flashes repeatedly when the input range of any channel has been exceeded. DETAILED DESCRIPTION OF COMMUNICATION PROTOCOL The detailed description of Spinel communication protocol used by is available for downloading from the web page. Page 11

Data transmission in industry, line and protocol conversions, RS232/485/422/USB/Ethernet/GPRS/ WiFi, measurement modules, intelligent temperature sensors, I/O modules, and custommade electronic applications. Address: Strasnicka 3164 102 00 Prague 10 Czech Republic Tel: +420 267 314 267 +420 267 314 268 +420 602 379 954 Fax: +420 267 314 269 Internet: E-mail: info@papouch.com w w w. p a p o u c h. c o m