MAC Ope ra tor Terminal



Similar documents
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

RS - SPM. Serial parallel translator module

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

HT580 User Reference Guide. Version 1.0

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PPM Users Manual Signature Software

MAC Ope ra tor Terminal

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ISHIDA BC Scale to Scale Communications

Rack mounted telephone- and leased line modem for industrial applications

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

RC2200DK Demonstration Kit User Manual

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Telephone- and leased line modem for industrial applications TD-36

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

DAB+ / FM Tuner Model: TU-201

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Installation and Operating instructions for. CP70xx Control Panel. Version: 1.6 Date:

Industrial Bar Code Scanners

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Industrial Bar Code Scanners

Senses SV series industrial monitor user manual

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

1-Port R422/485 Serial PCIe Card

1. SAFETY INFORMATION

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Directory chapter 04

Bluetooth to Serial Adapter

THE SERIALS DOTMATRIX DISPLAYS WITH RS-232

VIDEO DOOR PHONE SYSTEM

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

1 Serial RS232 to Ethernet Adapter Installation Guide

LwLVision-USB 2.0. Installation Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LTM-1338B. Plus Communications Manual

The Clavinova-Computer Connection

Integrating Sound Level Meter and Datalogger

Waveguide Access Point WGA631. Product Guide

XP Series Balances Operation Manual

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM

PD-300 SERIES 2 X 20 LCD CUSTOMER DISPLAY Rev. C0

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

MICROSYNC. User Manual. Microgate s.r.l. Via Stradivari, 4 Stradivaristr BOLZANO - BOZEN ITALY

SOUND LEVEL METER 94405

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

How To Run An Nport I5000A Device Server

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Instruction Manual FL

DVR-4TL/8TL/16TL Setup Guide

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Temperature & Humidity SMS Alert Controller

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

REGTRONIC OPERATING INSTRUCTIONS

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Instruction Manual. T3111 T3111L T3111P T3111Ex

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Product Specification instalert Rapid Messenger Variable Message Sign

4.3-inch Back-Up Camera

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

Network Interface Panel User s Guide NPD EN

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

Model: DC-A2IO Advanced HVAC Controller

User Manual I1010Q16DCZ

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

Ethernet Networking Installation & Operations Manual Humminbird ETHERNET

User manual DMX CONTROL 512. Table of contents

Vibration Monitoring System Adash 3600

Combi switchbox with integrated 3/2 way pilot valve

How to read this guide

Teleservice via RS232 interface XC100/XC200

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

aseries A13B Mini Bullet Camera User Manual

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

BW-500 BED WEIGHER USER MANUAL

is then retained absolutely without interruption.

LOW COST GSM MODEM. Description. Part Number

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

PC Utility User s Manual

ELCOMPONENT LTD. User Manual

LCD Drawer User Manual

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

VFS24/32HDIP. Public Display IP Monitor User Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Transcription:

MITSUBISHI ELECTRIC MAC Ope ra tor Terminal Human-Machine-Interface In stal la tion Manual MAC 40+ MITSUBISHI ELECTRIC EUROPE B.V. FACTORY AUTOMATION

Contents Safety precautions...2 Introduction...4 Function overview...5 Installation...6 A small example...11 Overview...14 Technical data...19 Drawings...A1 Mitsubishi Electric Europe B.V.1997 All examples in this manual are used solely to promote understanding of how the equipment works and its operation. Mitsubishi Electric Europe B.V takes. no responsibility if these examles are used in real applications. Because of the great many application areas for this equipment, the user himself must acquire the appropriate knowledge needed to use the equipment correctly for particular applications. Mitsubishi Electric Europe B.V. absolves itself of all responsibilities for damage and injuries that may occur during installation or use of this equipment. Mitsubishi Electric Europe B.V absolves. itself of all responsibilities for any type of modification made to the equipment. Only approved spare parts and accessories manufactured according to specifications of Mitsubishi Electric Europe B.V should. be used. The equipment must not be used in an explosive environment. 1

Safety precautions General Check the delivery for transport damage. If damage is found, advise your supplier. The product fulfils the requirements of article 4 of EMC directive 89/336/EEC. Do not use the product in an explosive environment. Modifications, changes and additions to the product are forbidden. Use only spare parts approved by Mitsubishi Electric Europe B.V. Read the user instructions carefully before use. This equipment should only be operated by qualified personnel. At installation The product is constructed for stationary installation. Install the product according to the accompanying installation instructions. The product must be grounded according to the accompanying installation instructions. This equipment must be installed by qualified personnel. High voltage, signal and supply cables must be separated. The product should not be mounted in direct sunlight. In use Keep the equipment clean. Emergency stop and other safety functions should not be controlled from the terminal. Do not touch the keys, displays, etc. with sharp objects. 2

Service and maintenance The agreed warrenty applies. Clean the display and face with a soft cloth and mild detergent. Repairs should be made by qualified personnel. At disassembly and scrapping Local regulations apply concerning recycling of products or part. Please note that the lithium battery, electrolyte condenser and display contain hazardous substances. 3

Introduction This manual describes the operator s panels MAC 40+ and MTA-100. Hereafter these products are referred to as the terminal. The terminal is operator s panel in a family of terminals developed to satisfy the demands made for man-machine communication. The functions built into the terminal include among other things the possibility to display text with dynamic indication, control, function keys and LEDs. A terminal is programmed directly from the built-in keyboard or from a PC with the MAC Programmer/SW-MTA software. The programmed project is stored in the terminal. Terminals have for the most part an object-orientated way of working which makes them easy to use. For more detailed information see the manual for the terminals. 4

Summary of functions Textblock Textblock is used to build up dialogs. A Textblock can consist of an arbitrary number of text lines. At the same time, 2 rows each of 16 characters are displayed. Static text Static text is text written in Textblock which is not changed when executing the program. Dynamic objects Dynamic objects are fields in the text which are linked to the signals in the PLC system. There are 7 types of dynamic object: digital, analog, jump, date/time, bar graph, multiple choice object and text object. Function keys F1 The function keys can be linked to the digital signals which are set when the function key is pressed in run-time mode. LED The LEDs are controlled by digital signals in the PLC system. 5

Installation A-CPU The terminals are connected to the PLC system s CPU port or the A series communication ports. Voltage supply Power for the terminal is supplied from the front port through the cable. FX Connection to the PLC system s CPU port Connect the MAC30/40-CAB cable to the outlet on the back of the terminal. To connect to the F1/F2 series, the F2-20GF1 adaptor is required. The F2-20GF1 should be set to 19,200 baud. If the terminal is to be connected to an FX0 system, the FX-20P-CABN cable or the enclosed cable together with the FX-20P-CADP cable is used. The maximum cable length between the terminal and the PLC system is 3 meters. If you need a longer cable you must use a cable in which the power supply voltage is made external (the same cable as you use when the terminal is connected to F1/F2). 25-pol D-SUB male CTS+ 5 CTS- 18 RXD+ 3 RXD- 16 RTS+ 4 RTS- 17 TXD+ 2 TXD- 15 VCC 12 GND 7 VCC 13 GND 8 20 21 Shield connected to D-sub cover MAC30/40-CAB 25-pol D-SUB male 5 18 3 16 4 17 2 15 12 VCC 7 GND 13 VCC 8 GND 20 GND 21 RXD ENABLE Shield connected to D-sub cover FX0 RXD+ 7 RXD- 4 TXD+ 2 TXD- 1 +5V 5 0V 3 Mini-DIN cover FX-20P-CABN 3 TXD+ 16 TXD- 2 RXD+ 15 RXD- 12 VCC 7GND 21 RXD 20 GND ENABLE 6

C24 Connection to an AJ71C24/ AJ71UC24 25-pin D-sub male 330Ω RXD+ 3 RXD- 16 TXD+ 2 TXD- 15 GND 7 GND 8 VCC 12 VCC 13 Shield connected to D-sub cover +5V 0V SDA SDB RDA RDB SG The terminal is connected to the RS422 port on the AJ71C24/AJ71UC24. Power supply voltage +5 VDC, must be connected from an external power supply. The switches on the AJ71C24 should be set as follows: Station no.: 00 Mode: A Transmission 11, 12, 14, 15, 21 and 22 ON, switches remainder OFF. The switches on the AJ71UC24 should be set as above. Furthermore switch 23 should be ON. The settings result in 19,200 baud, 8 data bits, 1 stop bit and no parity. The parameters in configuration mode under Port parameters, PLC, in the terminal should be set in the same way. Connection to an A1SJ71C24-R4 The terminal is connected to the RS422 port on the A1SJ71C24-R4. Power supply voltage +5 VDC, must be connected from an external power supply. The switches on the AJ71C24 should be set as follows: Mode: 5 Transmission 2, 4, 6, 7, 8, 12 ON switches remainder OFF. The settings result in 19,200 baud, 8 data bits, 1 stop bit and no parity. The parameters in configuration mode under Port parameters, PLC, in the terminal should be set in the same way. 7

Connection to an A2CCPUC24 The terminal is connected to the CPU port or the Computer Link port (RS422) on the A2CCPUC24. The switches on the Computer Link port should be set as follows: Station no. 00 Mode: A Transmission 12, 13, 14, 18, 19 and 20 ON switches remainder OFF. The settings result in 19,200 baud, 8 data bits, 1 stop bit and no parity. The parameters in configuration mode under Port parameters, PLC, in the terminal should be set in the same way. Programming from personal computer For programming of the terminal it is recommended that the PC software, MAC Programmer/SW-MTA, is used. This software will make programming easy and also gives a back-up of the project. To connect a terminal to a PC use the convert unit SC-06N. The example in this manual is programmed directly from the terminal keyboard. 8

Keyboard and choice of menu F1 F2 F3 F4 F5 F6 F1 Upper case Lower case Del Ins F2 A E I M Q U Y C1 C5 + (! B F J N R V Z C2 C6 = )? Clear MAIN MENU Enter Del Block Spec. Char. Mem Left The terminal has a compact keyboard where each key has several functions. There are four further characters in each corner of the number keys, the [-] and [.] keys. One of the functions keys is used to write these. [F1] for the character in the upper left corner, [F2] for the upper right. [F4] for lower left and [F5] for the lower right. Hold the function key pressed while pressing the required key. The codes C1-C8 stand for the character codes specific for your own language. The terminal is designed with a menu system which makes it easy for the user to enter information and monitor his system. There is a general rule when choosing from the menus. To be able to select a function, you must first point to it. You do this by moving the cursor to the right line with the arrow keys. Then press [NEXT], key [F6]. If several alternatives exist than there is room for on the screen, you can scroll the text with the arrow keys. Press [LEAVE], key [F5], to exit from a menu. F3 C G K O S W C3 C7 * < Blank F4 D H L P T X % C4 C8 / > # 9

Settings A number of basic settings have to be entered before using the terminal. The settings are entered in the configuration mode. You are automatically in the programming mode when start up. To change to the configuration mode quickly press [LEAVE], that is to say [F5], twice. The SETUP menu is displayed in the configuration mode. The following settings are necessary: Choice of PLC system You must choose to which PLC system the terminal is to be connected. Move the cursor with the arrow keys to the PLC-selection menu and press [ENTER]. Select the required PLC system and press [ENTER]. Choice of character set The majority of languages have letters which are specific to that language. By selecting the character set you can choose to which letters the keys C1-C8 correspond. Menu language Various menu languages can be chosen with the terminal. This manual assumes that English has been chosen as menu language. --- [SETUP] --- >PLC Selection System signals Language Character set Date/Time Format Port parameters Erase memory Terminal options >F1/F2 FX A-CPU AJ71-C24 (S3) 10

A small example >Edit Transfer Block list The following section gives a small example of how to start creating applications quickly. The example follows the whole sequence from building up an application to executing to the PLC system. The terminal and the PLC system must be connected together to be able to use the example. In this example we shall make a Textblock which shows the status of the X0 input. Switch on the terminal and enter the programming mode. The start-up screen will be seen for a short period. This is followed by the Programming menu. The Edit alternative is marked from the beginning. Press [NEXT] to enter the editing mode. You select the type of object in the menu now displayed. In this example we shall define a Textblock. 11

1. Select Text blocks. Press [NEXT]. 2. Enter the number of the block here, in this case 0. The cursor,_, is placed in the right position so that all that is needed is to press [0] and then [ENTER]. 3. Move the cursor to Statusword and press [INFO]. >Text blocks Function keys BLOCK NUMBER:0 Disp. sign.: Status word: 4. Place the cursor on 1st obj and press [INFO] to show YES. 5. Press [NEXT]. 6. Press [NEXT] to begin editing the block. The screen clears and you can begin entering text. Curs. off:no 1:st obj:yes Dis. MAIN:NO MORE-ind.:NO Auto Ent:NO 12

>Digital Analog Jump Date/Time Bar graph Mult.choice Text 7. Press #, [F4] [.]. A list of available dynamic objects is now displayed. 8. The Digital option is already marked. Press [ENTER]. The dialog box is now displayed for the digital object. D.Obj.: X0 Text 0: OFF Text 1: ON Manoeuv: NO 9. First enter which I/O signal the object is to illustrate. Do this by entering the required address, in this case X0, after the text D.Object. Finally press [ENTER]. 10. Enter the text which will be displayed when the signal is 0, in this example OFF, and press [ENTER]. 11. Enter the text which will be displayed when the signal is 1, in this example ON, and press [ENTER]. 12. Press [NEXT] to close the dialog box. The dynamic object is now shown by # and two - on the screen. 13. Press [LEAVE] until the programming menu is shown. When the program is ready, it can now be checked in run-time mode. Press [MAIN MENU] [INFO] to switch to run-time mode. When the run-time mode starts the start-up screen is displayed. The block is then displayed automatically. 13

Overview Modes The terminal has three modes Run-time mode Alter between run-time mode and programming mode with [MAIN MENU] [INFO]. Programming mode Alter between programming mode and run-time mode with [MAIN MENU] [INFO]. Configuration mode Press [LEAVE] when the start-up screen is displayed in programming mode Dynamic objects The following dynamic text objects can be used in block and linked to the stated types of signals Digital: A series: X, Y, M, B, F, T, C FX series: X, Y, M, S, T, C Analog: Bar graph: Multichoice: Text: Jump: Date/time: A series: D, W, R, T, C FX series: D, T, C A series: D, W, R, T, C FX series: D, T, C A series: X, Y, M, B, F, T, C FX series: X, Y, M, S, T, C A series: D, W, R FX series: D Jump objects do not use signals from the PLC system PLC clock. 14

System block Certain blocks are reserved for special purposes: 0 Main menu 990-997 Reserved, do not use 998 LED 999 Function keys 15

Keys Programming mode Shift Shift Shift Shift Shift Leave Next F1 F2 F3 F4 Leave F5 Next F6 Move Shift between alternatives Display status word menu Erase the character on the left Clear Next line Enter Erase the character by the cursor Insert characters Upper case (capital) letters Lower case (small) letters Gives access to special character table F1 F1 F1 F1 F1 MAIN MENU 16

F1 F1 Clear Number of bytes remaining Erase block in block menu MAIN MENU Shift between programming and run-time modes F1 F2 Keyboard layout 17

Run-time mode Function keys F1 Next F6 Move between objects Move linewise Display 0 and 1 texts for digital object Display min and max limits for analog and bar graph objects Display Textblock 0 MAIN MENU Carry out jump with jump object End entering analog object Forcibly set digital object Entry field text object List of choices multi-choice object Enter Erase character on the left when entering Clear Shift between programming and run-time modes MAIN MENU 18

Technical data Front panel Width 150 x height 170 mm. Black anodized aluminumsheet Fitting depth Max 33 mm. Fitting holes Hole: Width 132 ±4mm x 152 ±4mm, 4 fixed screws, M4, C-C 140 x 160 mm. Max panel thickness 7 mm. Safety standard for front panel IP 65 Safety standard for reverse side IP 20 Keyboard materials Membrane keyboard with metal snap discs. Overlay film of polyester with print on reverse side. Life: 1 million operations. Reverse side material Textured powder varnish, 1 mm steel plate Weight Excl. D-sub cabling, 0.7 kg PLC system connection 25-position D-sub connector, female with standard screw lock 4-40 UNC, RS422 communication. Cable for PLC system 6 pair cable, shielded, shielded D-sub casing. Locking screws to the PLC system: M2.5 locking screws to the terminal: 4-40 UNC. Display LCD display (liquid crystal), Supertwist 2 lines of 16 characters each. 8 mm character height. The contrast adjustable with potentiometer inside. 19

Supply voltage From PLC system or via external power supply 5 VDC ±5% min200 ma. Memory 10 year data retention min. 10000 write cycles/ byte. EEPROM. Internal logic voltage +5V ±5%. Connected to the chassis via 0.1µF capacitor. Ambient temperature 0º to 50ºC Storage temperature -20º to +60ºC Air humidity Max 90% without condensation Interference test Interference tested for external noise according to: IEC 801-2 (6 kv contact discharge, 8 kv air discharge), IEC 801-3 (10V/m), IEC 801-4 level 4. The product have passed and comply with specifications of the above tests. The product must only be used for applications covered by these standards. EMC-tests on the terminal Beijer Electronics confirm that the terminals conforms with the essential protection requirements in article four of the directive 89/336/EEC. GB 20

A-1

A-2

A-3

A-4

A-5

A-6

A-7

A-8

A-9

A-10

A-11

A-12

MITSUBISHI ELECTRIC MITSUBISHI ELECTRIC EUROPE B.V. FACTORY AU TO MA TION GOT HA ER STR. 8, D- 40880 RA TIN GEN TEL.: (0 21 02) 4 86-10, FAX: (0 21 02) 4 86-1 12