AFL Pumps Double-Acting, Single Ended, High Flow Liquid Pump Product Catalogs
Air-Driven, High Pressure Liquid Pump Series AFL35-1D Double-Acting, Single Ended, Single Piston Air Drive Technical Data: Liquid Side Specifications Service: Oil, Water or Water/Oil mixture and other fluids depending on material compatibility Maximum Outlet Pressure: 5,600 psi (386 bar) Air to Liquid Pressure Ratio: 1:39 Isolation Chamber (prevents process contamination of air section): Standard Volume Displacement Per Stroke: 6.02 in 3 (98.7 cm 3 ) Inlet Connection: 1" NPT Outlet Connection: Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure (Contact Parker Autoclave Engineers for Additional Options) Technical Data: Air Side Specifications Air Drive Pressure Range: 15-150 psi (1-10 bar) *See note Nominal air pressure required for 5,600 psi (386 bar) output pressure is 144 psi (9.9 bar) Inlet Port: 3/4" FNPT Pilot Port: 1/8" FNPT (unregulated air) Exhaust Port (muffler removed): 1" NPT Max Air Consumption @ 90 psi: 167 SCFM Prelubricated at Factory General Specifications Maximum Operating Temperature: 0-140º F (-18º to 60º C) Net Weight: 51.8 lbs. (23.5 kg) Pressure Head: 15-5 PH Stainless Steel Stainless steel plunger utilizing a proprietary multi-layer carbon based coating with diamond like carbon exterior layer - 3 times the hardness of stellite with a coefficient of friction equal to/less than PTFE Check Valve Glands: 316 Stainless Steel Liquid Seal: See Ordering Guide for Options Air Drive Seals: Buna N Note: Maximum air drive pressure is limited by maximum output pressure. MADE IN THE U.S.A. Double-Acting, Single Piston Air Drive
Ordering Guide: For complete information on available pump options, contact Parker Autoclave Engineers. Typical catalog number: AFL35-1DBCPV AFL35-1D Pump Type / Size / Ratio AFL = High Flow High Pressure Pump 6" Single Piston Air Drive 1:39 Air-to-Liquid Pressure Ratio Maximum 5,600 psi (386 bar) Single Ended, Double Acting Liquid Head B Location C Isolation Chamber PV Liquid Seal Material *B = Bottom *C = Included * PV = UHMWPE U-Cup with Viton O-rings *Standard for Stock Pumps PE = UHMWPE U-Cup with EPDM O-rings PB = UHMWPE U-Cup with Buna-N O-rings PC = UHMWPE U-Cup with Perfluoroelastomer O-rings Flow Rate vs. Outlet Pressure: AFL35-1D Series Actual flow rates will vary depending on air flow capacity, downstream flow restrictions, and fluid type. Technical Specifications & Performance Data Air- Driven, High Pressure Liquid Pump - Series AFL35-1D
Dimensional Data: 9.86 (250.36) 5.81 (147.49) See Note 7.39 (187.79) 6.50 (165.10) 4.33 (109.98) Slot Spacing Both Brackets 2.40 (60.95) Pilot Air inlet Female 1/8" NPT 9.46 (240.40) 11.28 (286.54) 11.81 (299.95) 13.37 (399.55) 24.09 (611.91) Isolation Chamber Port 1/8" NPT Liquid Outlet Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure Air Inlet Female 3/4" NPT Female 1" NPT Front View 3.61 (91.61) 5.67 (144.06) Right View 8.841 (215.430) 2.103 (53.416) Air Inlet Female 3/4" NPT Bottom View Female 1" NPT Note: Each Mounting Bracket includes (2) x 9/16" (14.29) slots for 1/2" Bolts. All dimensions are for reference only and are subject to change without notice. Primary Dimensions: Inches Secondary Dimensions: (Millimeters) Air-Driven, High Pressure Liquid Pump - Series AFL35-1D Left View Technical Specifications & Performance Data
Accessories Available: Air Control Packages Pneumatic Pilot switches and Solenoid Valves Stroke Counter Relief Valve / Safety Heads Complete line of High Pressure Components - Valves, Fittings & Tubing Spare Parts Service Typical Air Control Package For complete information on available high pressure accessories, please contact Parker Autoclave Engineers. WARNING FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request). 2014 Parker Hannifin Corporation Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9320BE April2014 Instrumentation Products Division Autoclave Engineers Operation 8325 Hessinger Drive Erie, Pennsylvania 16509-4679 USA PH: 814-860-5700 FAX: 814-860-5811 www.autoclave.com Parker Hannifin Manufacturing Ltd. Instrumentation Products Division, Europe Industrial Estate Whitemill Wexford, Republic of Ireland PH: 353 53 914 1566 FAX: 353 53 914 1582 Caution! Do not mix or interchange parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty. ISO-9001 Certified Air-Driven, High Pressure Liquid Pump - Series AFL35-1D
Air-Driven, High Pressure Liquid Pump Series AFL60-1D Double-Acting, Single Ended, Single Piston Air Drive Technical Data: Liquid Side Specifications Service: Oil, Water or Water/Oil mixture and other fluids depending on material compatibility Maximum Outlet Pressure: 10,000 psi (690 bar) Air to Liquid Pressure Ratio: 1:70 Isolation Chamber (prevents process contamination of air section): Standard Volume Displacement Per Stroke: 3.40 in 3 (55.7cm 3 ) Inlet Connection: 1" NPT Outlet Connection: Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure (Contact Parker Autoclave Engineers for Additional Options) Technical Data: Air Side Specifications Air Drive Pressure Range: 15-150 psi (1-10 bar) *See note Nominal air pressure required for 10,000 psi (690 bar) output pressure is 143 psi (9.9 bar) Inlet Port: 3/4" FNPT Pilot Port: 1/8" FNPT (unregulated air) Exhaust Port (muffler removed): 1" NPT Max Air Consumption @ 90 psi: 167 SCFM Prelubricated at Factory General Specifications Maximum Operating Temperature: 0-140º F (-18º to 60º C) Net Weight: 51.8 lbs. (23.5 kg) Pressure Head: 15-5 PH Stainless Steel Stainless steel plunger utilizing a proprietary multi-layer carbon based coating with diamond like carbon exterior layer - 3 times the hardness of stellite with a coefficient of friction equal to/less than PTFE Check Valve Glands: 316 Stainless Steel Liquid Seal: See Ordering Guide for Options Air Drive Seals: Buna N Note: Maximum air drive pressure is limited by maximum output pressure. MADE IN THE U.S.A. Double-Acting, Single Piston Air Drive
Ordering Guide: For complete information on available pump options, contact Parker Autoclave Engineers. Typical catalog number: AFL60-1DBCPV AFL60-1D Pump Type / Size / Ratio AFL = High Flow High Pressure Pump 6" Single Piston Air Drive 1:70 Air-to-Liquid Pressure Ratio Maximum 10,000 psi (690 bar) Single Ended, Double Acting Liquid Head B Location C Isolation Chamber PV Liquid Seal Material *B = Bottom *C = Included * PV = UHMWPE U-Cup with Viton O-rings *Standard for Stock Pumps PE = UHMWPE U-Cup with EPDM O-rings PB = UHMWPE U-Cup with Buna-N O-rings PC = UHMWPE U-Cup with Perfluoroelastomer O-rings Flow Rate vs. Outlet Pressure: AFL60-1D Series Actual flow rates will vary depending on air flow capacity, downstream flow restrictions, and fluid type. Technical Specifications & Performance Data Air- Driven, High Pressure Liquid Pump - Series AFL60-1D
Dimensional Data: 9.86 (250.36) 5.81 (147.49) See Note 7.39 (187.79) 6.50 (165.10) 4.33 (109.98) Slot Spacing Both Brackets 2.40 (60.95) Pilot Air inlet Female 1/8" NPT 9.46 (240.40) 11.28 (286.54) 11.81 (299.95) 13.37 (399.55) 24.09 (611.91) Isolation Chamber Port 1/8" NPT Liquid Outlet Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure Air Inlet Female 3/4" NPT Female 1" NPT Front View 3.61 (91.61) 5.67 (144.06) Right View 8.841 (215.430) 2.103 (53.416) Air Inlet Female 3/4" NPT Bottom View Female 1" NPT Note: Each Mounting Bracket includes (2) x 9/16" (14.29) slots for 1/2" Bolts. All dimensions are for reference only and are subject to change without notice. Primary Dimensions: Inches Secondary Dimensions: (Millimeters) Air-Driven, High Pressure Liquid Pump - Series AFL60-1D Left View Technical Specifications & Performance Data
Accessories Available: Air Control Packages Pneumatic Pilot switches and Solenoid Valves Stroke Counter Relief Valve / Safety Heads Complete line of High Pressure Components - Valves, Fittings & Tubing Spare Parts Service Typical Air Control Package For complete information on available high pressure accessories, please contact Parker Autoclave Engineers. WARNING FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request). 2014 Parker Hannifin Corporation Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9318BE April2014 Instrumentation Products Division Autoclave Engineers Operation 8325 Hessinger Drive Erie, Pennsylvania 16509-4679 USA PH: 814-860-5700 FAX: 814-860-5811 www.autoclave.com Parker Hannifin Manufacturing Ltd. Instrumentation Products Division, Europe Industrial Estate Whitemill Wexford, Republic of Ireland PH: 353 53 914 1566 FAX: 353 53 914 1582 Caution! Do not mix or interchange parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty. ISO-9001 Certified Air-Driven, High Pressure Liquid Pump - Series AFL60-1D
Air-Driven, High Pressure Liquid Pump Series AFL100-1D Double-Acting, Single Ended, Single Piston Air Drive Technical Data: Liquid Side Specifications Service: Oil, Water or Water/Oil mixture and other fluids depending on material compatibility Maximum Outlet Pressure: 15,000 psi (1034 bar) Air to Liquid Pressure Ratio: 1:113 Isolation Chamber (prevents process contamination of air section): Standard Volume Displacement Per Stroke: 2.30 in 3 (37.7 cm 3 ) Inlet Connection: 1" NPT Outlet Connection: Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure (Contact Parker Autoclave Engineers for Additional Options) Technical Data: Air Side Specifications Air Drive Pressure Range: 15-150 psi (1-10 bar) *See note Nominal air pressure required for 15,000 psi (1034 bar) output pressure is 132.75 psi (9.15 bar) Inlet Port: 3/4" FNPT Pilot Port: 1/8" FNPT (unregulated air) Exhaust Port (muffler removed): 1" NPT Max Air Consumption @ 90 psi: 167 SCFM Prelubricated at Factory General Specifications Maximum Operating Temperature: 0-140º F (-18º to 60º C) Net Weight: 51.8 lbs. (23.5 kg) Pressure Head: 15-5 PH Stainless Steel Stainless steel plunger utilizing a proprietary multi-layer carbon based coating with diamond like carbon exterior layer - 3 times the hardness of stellite with a coefficient of friction equal to/less than PTFE Check Valve Glands: 316 Stainless Steel Liquid Seal: See Ordering Guide for Options Air Drive Seals: Buna N Note: Maximum air drive pressure is limited by maximum output pressure. MADE IN THE U.S.A. Double-Acting, Single Piston Air Drive
Ordering Guide: For complete information on available pump options, contact Parker Autoclave Engineers. Typical catalog number: AFL100-1DBCPV AFL100-1D Pump Type / Size / Ratio AFL = High Flow High Pressure Pump 6" Single Piston Air Drive 1:113 Air-to-Liquid Pressure Ratio Maximum 15,000 psi (1034 bar) Single Ended, Double Acting Liquid Head B Location C Isolation Chamber PV Liquid Seal Material *B = Bottom *C = Included * PV = UHMWPE U-Cup with Viton O-rings *Standard for Stock Pumps PE = UHMWPE U-Cup with EPDM O-rings PB = UHMWPE U-Cup with Buna-N O-rings PC = UHMWPE U-Cup with Perfluoroelastomer O-rings Flow Rate vs. Outlet Pressure: AFL100-1D Series Actual flow rates will vary depending on air flow capacity, downstream flow restrictions, and fluid type. Technical Specifications & Performance Data Air- Driven, High Pressure Liquid Pump - Series AFL100-1D
Dimensional Data: 9.86 (250.36) 5.81 (147.49) See Note 7.39 (187.79) 6.50 (165.10) 4.33 (109.98) Slot Spacing Both Brackets 2.40 (60.95) Pilot Air inlet Female 1/8" NPT 9.46 (240.40) 11.28 (286.54) 11.81 (299.95) 13.37 (399.55) 24.09 (611.91) Isolation Chamber Port 1/8" NPT Liquid Outlet Parker Autoclave Engineers SF562CX10-9/16" Female Medium Pressure Air Inlet Female 3/4" NPT Female 1" NPT Front View 3.61 (91.61) 5.67 (144.06) Right View 8.841 (215.430) 2.103 (53.416) Air Inlet Female 3/4" NPT Bottom View Female 1" NPT Note: Each Mounting Bracket includes (2) x 9/16" (14.29) slots for 1/2" Bolts. All dimensions are for reference only and are subject to change without notice. Primary Dimensions: Inches Secondary Dimensions: (Millimeters) Air-Driven, High Pressure Liquid Pump - Series AFL100-1D Left View Technical Specifications & Performance Data
Accessories Available: Air Control Packages Pneumatic Pilot switches and Solenoid Valves Stroke Counter Relief Valve / Safety Heads Complete line of High Pressure Components - Valves, Fittings & Tubing Spare Parts Service Typical Air Control Package For complete information on available high pressure accessories, please contact Parker Autoclave Engineers. WARNING FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request). 2014 Parker Hannifin Corporation Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9293BE April2014 Instrumentation Products Division Autoclave Engineers Operation 8325 Hessinger Drive Erie, Pennsylvania 16509-4679 USA PH: 814-860-5700 FAX: 814-860-5811 www.autoclave.com Parker Hannifin Manufacturing Ltd. Instrumentation Products Division, Europe Industrial Estate Whitemill Wexford, Republic of Ireland PH: 353 53 914 1566 FAX: 353 53 914 1582 Caution! Do not mix or interchange parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty. ISO-9001 Certified Air-Driven, High Pressure Liquid Pump - Series AFL100-1D