GARAGE MAIN FLOOR PLAN

Similar documents
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

POST AND FRAME STRUCTURES (Pole Barns)

Mark Cramer Inspection Services, Inc.

STANDARD OPEN PATIO COVER

TYPICAL PATIO COVERS 111

Page & Turnbull imagining change in historic environments through design, research, and technology

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Patio Covers / Carports

Additions and Alterations

Residential Deck Safety, Construction, and Repair

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

Chapter 6 ROOF-CEILING SYSTEMS

PDmB, Inc. Definitions

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

8/18/14. Introduction to. Framing. Terminology and Concepts

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Basic Requirements for Residential Plan Review _

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

COMMONLY USED RESIDENTIAL BUILDING CODES

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Excerpts from the Canadian National Building Code (NBC)

Attached/Detached Patio Cover/Carport

Uncovered Decks & Porches

Residential Decks. Planning and Development Services Department

Formwork for Concrete

Section A Roof Truss

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

SUPER SHED. Indoor shelter for your outdoor tools.

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Pre-Drywall Inspection Report

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

How to secure your property after a disaster

Building Construction. Lightweight construction. Conventional Construction

Superform Products Ltd.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Certification: Building Plans Examiner. Exam ID: B3

Sample Drawing Package for One and Two Family Dwelling Applications

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

DEFAULT HEAT LOSS COEFFICIENTS

CHAPTER 6 CONSTRUCTION TYPES

Technical Assignment 2 TABLE OF CONTENTS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

6 RETROFITTING POST & PIER HOUSES

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

Georgia Association of Home Inspectors

Best Barns USA Assembly Book

Building Information Packet

HomeSpec REPORT SUMMARY

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

2014 FLORIDA BUILDING CODE

Asphalt Shingle Application Requirements

Residential Building Inspection Policies

March 14, Installation of Bay, Bow and Garden Windows

Building Code Clarifications - 7. Fire Resistance

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Post and Beam Construction

Lesson Plan Course Title: Construction Technology

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Footing and Temporary Power Inspection

CHIMNEYS AND FIREPLACES

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Residential Plan Routing Information

ISO Types 1-6: Construction Code Descriptions

CALIFORNIA BUILDING CODE

FIRE AND SMOKE PROTECTION FEATURES

Residential Foundations and Basements

Residential Building Permits

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Requirements for Building Application Submission

Timber Frame Construction

Typical Finished Basement Details

FIRE AND SMOKE PROTECTION FEATURES

Engineered Wood Foundations

Timber Decks. Technical Note. March 2007

Home Inspection Report

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

AMERICAN GOTHIC PLAYHOUSE

ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood.

MICHIGAN RESIDENTIAL CODE 2003

DENVER MODEL 30 X 30 SPECIFICATIONS

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

LIGHT FLOOR AND WALL FRAMING

MUNICODE SERVICES LTD.

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

How To Make A House Safe

Transcription:

40'-0" 1 1 120140 19'-6" 72'-0" () 16'-6" 1 1 40'-0" '-0" '-0" 11'-6" 8'-6" '-0" '-0" 72'-0" GARAGE MAIN FLOOR PLAN Custom 40 x 72-16' Garage Plan Plan #g22 By Page 1 Page 2 Page Page 4 Page Title Main Floor Plan Elevation Views Post Plan & Pictorials Framing and Details Detail Page To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SDSCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official. BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. GARAGE TO BE BUILT AS PER IRC 2006 OR CURRENT LOCAL CODE @COPYRIGHT SDSCAD 1

REAR ELEVATION 4/12 PITCH FRONT ELEVATION 16' Tall Post Walls Metal Roofing and Siding LEFT ELEVATION RIGHT ELEVATION @COPYRIGHT SDSCAD REVISIONS 2

120140 Sides Post spacing 8' o.c. End Post spacing as needed for doors Braced s required every 2' along exterior walls. Solid plywood sheathing on interier of 2x6 horizontals required from top to bottom as referenced by note on plan 4" Concrete Floor over gravel fill, sloped 1" per 10' to door Thickened edge slab 12" x 24" () POST PLAN PICTORIAL VIEWS Concrete Floor option requirements: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 01-66, Type II cement, 200 psi at 28 days, " maximum slump.. Reinforcing to be ASTM A61-Bars with Fy=60 ksi lamp 0 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 200 psi for quality only.. Anchor bolts shall be A-07 embedded 7" minimum into concrete or masonry grout. 6. All footings minimum 24" below final grade @COPYRIGHT SDSCAD

() GARAGE RO PRE-ENGINEERED TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 24" o.c. General framing: (Douglas Fir) 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to Span 2-2x4's 4' + to 6'-0" Span 2-2x6's 6' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to Span 2-2x12's or as noted on plan 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 2' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of 7/16 inch.. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs.. Exterior wall framing to be 2"x6" studs at 16" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate. 6. Shear wall to be 7/16" Sheathing, see detail. 7. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 140 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. Roof Framing: 20' Tall 6 x 6 or 8" Dia Posts for walls 2 x 6 Horizontal on 24" centers see details Cross Section 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details.. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture's engineer.. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 6. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses. 7. Minimum header sizes shall be according to the header size table unless otherwise noted. 8. Basis of design roof live/snow load of 7 psf, and roof dead load of 1 psf. 9. Plywood roof decking to be Min ½" thick, 24/0, CDX or /8 wafer. WALL FRAMING SECTIONS SCALE 1/16"=1' @COPYRIGHT SDSCAD 4