Power supply CP-C.1 24/20.0; product revisions < D High-performance primary switch mode power supply

Similar documents
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic overload relay EF65, EF96 and EF146

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic overload relay EF19 and EF45

Analog signal converters CC-E I/I Current / current isolators

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Power Supplies 3. SDN-P DIN Rail Series

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Type: DILM32 10(24V50HZ) Article No.:

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

PHOENIX CONTACT - 01/2007

Redundancy Module QUINT-DIODE/40

Type: DILM50(230V50HZ,240V60HZ) Article No.:

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Relés e Contatores de Estado Sólido SIRIUS

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Type: DILM9 10(24VDC) Article No.:

Thermistor motor protection

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

R.C.C.B. s two-pole LEXIC

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 Series - Relay interface modules A

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

38 Series - Relay interface modules A

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

STRATO LED Drivers 70W, Single output

Manual motor starter MS116

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Safety technique. Emergency stop module BO 5988 safemaster

49 Series - Relay interface modules A. Features

RM4TG20 three-phase network control relay RM4-T - range V

15 Series - Electronic step relay and dimmer. Features SERIE

Pluggable interface relays CR-P Pcb relays

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PHOENIX CONTACT Features

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Catalog. Modular DIN rail components Installation contactors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

48 SERIES Relay interface modules 10 A

Industrial Power Supplies

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Technical catalogue. Modular DIN rail components Installation contactors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Technicaldata General

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

TEP 200WIR Series, Watt

Telephone- and leased line modem for industrial applications TD-36

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Waveguide Access Point WGA631. Product Guide

Emergency lighting units EM powerled

Bimetallic Overload Relay Specifications

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

APD / Outputs 19" DC/DC Converter, 50 Watt

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

650W Single Output Power Supply

DLP-PU/E Instruction Manual

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

CompactLogix Power Supplies Specifications

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Single Output Switching Power Supply

MasterINTERFACE 39 Series - Relay interface modules

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ABB i-bus KNX SA/S Switch Actuators Product Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Digital input modules

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Transcription:

Data sheet Power supply 24/20.0; product revisions < D High-performance primary switch mode power supply The power supplies are ABB s highperformance and most advanced range. With excellent efficiency, high reliability and innovative functionality it is prepared for the most demanding industrial applications. These power supplies have a 30 % integrated power reserve and operate at an efficiency of up to 94 %. They are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals the power supplies are the preferred choice for professional DC applications. Giving the power to control. 2CDC 271 004 V0015 Characteristics Rated output voltage 24 V DC Power reserve design delivers up to 130 % at T a 40 C Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust, 22.5-28.5 V Input voltage range 100-240 V AC, 90-250 V DC High efficiency ow power dissipation and low heating Free convection cooling (no forced cooling) Ambient temperature range during operation -25...+70 C Open-circuit, overload and short-circuit stable Integrated input fuse DC OK - signaling output "13-14" (Relay), Power reserve signaling output "I > I R (Transistor) Redundancy unit CP-A RU offering true redundancy, available as accessory Approval SEMI F47 Marks a CE Ordering details - Input voltage range Rated output voltage / current Type Order code Weight (1 pce) kg (lb) 100-240 V AC, 90-250 V DC 24 V DC / 20 A 24/20.0 1SVR360763R1001 1.57 (3.46) Related products Description Redundancy unit Type Order code Weight (1 pce) kg (lb) 2 inputs each up to 20 A and 1 output up to 40 A 40 V and M 5 A CP-A RU 1SVR427071R0000 0.89 (1.96)

Table of contents Characteristics...1 Ordering details -...1 Approval...1 Marks...1 Abbreviations...2 Functions...3 Application...3 Power reserve...3 Signaling output...3 Adjustable output voltage...3 ED and relay state table...4 EDs and signaling outputs...4 Operating mode...5 Parallel operation...5 Parallel connection of power supplies for increased power...5 Parallel connection of power supplies for redundancy...6 Mounting...7 Mounting positions...7 Mounting in position 7...7 Derating of output current for position 1...8 Electrical connection...8 24 and 48 V DC connection...9 Connection to TN, TT networks...9 Safety instructions and warnings...10 Technical data...11 Input circuit - Supply circuit...11 User interface...11 Output circuit - Power output...11 Signaling outputs...12 General data...12 Electrical connection...12 Environmental data...13 Isolation data...13 Standards...14 Electromagnetic compatibility...14 Technical diagrams...15 Efficiency diagrams...15 Characteristic curve of output...16 Characteristic curve of temperature...16 Dimensions...17 Further documentation...17 Abbreviations MCB - Miniature circuit breaker AC - Alternating current DC - Direct current ED - ight emitting diode - ine N - Neutral PE - Protective earth PC - Programmable logic controller DIN - Deutsche Industrie Norm PEV - Protective extra low voltage TN - Terre neutre (neutral grounded) TT - Terre terre (grounded network) IT - Isolé terre (isolated network) VDE - Verein Deutscher Elektrotechniker IP20 - international protection code AWG - American wire gauge IEC - International electrotechnical comission U - Underwriters laboratories EN - Europäische Norm SEV - Safety extra low voltage EMC - Electromagnetic compatibility SEMI - Semiconductor equipment materials international FCC - Federal communication comission CISPR - Comité international spécial des perturbations radioélectriques CSA - Canadian standards association 2 - Power supply 24/20.0; product revisions < D Data sheet

Functions 1 2 1 13-14: Relay output to signal output OK 2 I > I R : Power reserve transistor output 2CDC 271 004 V0015 3 4 5 6 3 OUTPUT +, : Output terminals 4 Indication of operational states OUTPUT OK: Green ED POWER RESERVE I > I R : Yellow ED 5 OUTPUT Adjust: Rotary potentiometer - Adjustment of output voltage 22.5-28.5 V DC 7 6 Circuit diagram 8 7 INPUT (+), N(-), o/pe: Input terminals 8 Side mounting screw holes for DIN rail adapter / lateral mounting Application The primary switch mode power supply has a wide AC or DC input voltage range. Furthermore the is equipped with capacitors that ensure a hold-up time of at least 40 ms. This enables worldwide usage and permits safe operation in fluctuating networks and battery-powered applications. The has a robust metallic housing and a reliable construction which enables usage in harsh industrial environments. The power reserve of up to 30 % enables trouble-free starting of heavy loads eliminating the need of usage of an oversized power supply. Power reserve The primary switch mode power supply is equipped with a power reserve functionality to handle the start-up of particulary heavy loads (e.g. of a capacitive load or a motor). To ensure that heavy loads are started up, the delivers additionally up to 30 % of the rated output current to secure the operation of the application. This status is displayed by the yellow ED labelled POWER RESERVE I > I R. Signaling output For the communication of the status of the power supply the is equipped with a relay output to signal output OK as well as a transistor output to indicate when the power reserve is active. These signals can be used for communication to a higher level control system e.g. a PC. Adjustable output voltage The CP-C range power supplies feature a continuously adjustable output voltage of 22.5 to 28.5 V DC. Thus they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. Data sheet Power supply 24/20.0; product revisions < D - 3

ED and relay state table Output OK - relay output 13 14 + max. 30 V AC, 0.5 A max. 24 V DC, 1 A (resistive load) oad 2CDC 272 013 F0015 + I > I R ength 30 m - ength 30 m 2CDC 272 014 F0015 Power reserve - transistor output EDs and signaling outputs Output voltage Output OK: ED green Relay 13-14 M 92 % of U out V Closed < 90 % of U out Z Open Output current Power reserve: ED yellow Transistor I>I R ImI R OFF ON (closed) I>I R V OFF (open) It is possible to use the messaging and signaling functionality with power supplies connected in parallel. The parallel operation has no influence on the function. 4 - Power supply 24/20.0; product revisions < D Data sheet

Operating mode Parallel operation There are two main reasons for a parallel connection of power supplies: Increase of power Redundancy Up to 5 devices of the same type can be connected in parallel. For safe and reliable operation it is important to follow the recommendations given in the following section. Parallel connection of power supplies for increased power If the current required by the load is higher than a single power supply can deliver, for example after the expansion of an existing installation, an increase of the output power can be obtained by connecting power supplies in parallel. The following prerequisites have to be fulfilled when connecting power supplies in parallel for the purpose of increased power: The paralleled devices must be of the identical type. Repeated voltage drops on the supply lines or at the terminals would lead to unbalanced load at the common connection point. To prevent this, you have to observe the following when connecting the power supply units: Identical lengths of the load supply lines. Identical conductor cross sections of the load supply lines. Terminal screws have to be fastened with the same torque to guarantee equal contact resistances. The output voltages of the power supplies must not differ by more than 50 mv. Otherwise, safe operation is not possible. load + - + + - - + + - - + + - - 1. 2. 3. 2CDC 272 002 F0015 Correct wiring for increased power load 2CDC 272 001 F0015 + - + + - - + + - - + + - - 1. 2. 3. 2CDC 272 003 F0015 Installation for increased power Incorrect wiring for increased power Important: The devices must not be connected directly to each other! This could lead to an overload of the terminals since the terminals are dimensioned for the maximum output current of a single power supply only. Always use a common connection point! Data sheet Power supply 24/20.0; product revisions < D - 5

Parallel connection of power supplies for redundancy Several power supplies are connected in parallel in order to guarantee continuous operation of the system if one power supply fails. can be used in two different redundancy modes depending on what type of redundancy is required: Simple redundancy, n+1 True redundancy Simple redundancy, n+1 redundancy For simple or n+1 redundancy, the power supplies are connected in parallel like for the increase of capacity. To achieve redundancy the current required by the load must not exceed the maximum output power of one single power supply (in case of 1+1 redundancy ) or n power supplies (where n is max. 4). We recommend connecting the primary sides of the power supplies to different phases of the mains in order to obtain continuous operation of the system if one phase fails. 1. n. + - + - I r1 I rn I oad (n-1) * I r 2CDC 272 005 F0215 Simple redundancy or n+1 setup True redundancy True redundancy gives higher system availability compared to simple or n+1 redundancy. In a true redundancy setup the power supplies are decoupled from each other with decoupling diodes. This protects the individual power supplies from affecting each other in case of failure of one unit or short cirucit on the secondary side or in the wiring. For two inputs of up to 20 A and one output up to 40 A the ABB redundancy unit CP-A RU (available as an accessory) can be used. The inputs of these units are connected to the terminals + and - of the power supplies. The loads are supplied directly from the outputs of the redundancy unit. + - + - + - + - INPUT 1 INPUT 2 CP-A RU OUTPUT N PE + + - - N PE 1 2 3 N PE oad 2CDC 272 006 F0215 True redundancy using a CP-A RU redundancy unit 6 - Power supply 24/20.0; product revisions < D Data sheet

Mounting To mount the power supply place the upper edge of the DIN rail adapter on the upper edge of the DIN rail holding the unit slightly tilted upwards as shown in the illustration. Then tilt the unit down until the latch snaps onto the DIN rail. 2CDC 273 002 F0015 Mounting positions Position 2 Position 4 Position 3 Position 1 Position 5 Position 7 2CDC 272 001 F0016 In order to ensure a sufficient convection in mounting position 1, the minimum distance to other modules must not be less than 25 mm in vertical direction and 25 mm in horizontal direction. For the derating of the output current, see the characteristic curve of temperature. Details for other mounting positions on request. Mounting in position 7 To mount the power supply in position 7 remove the DIN rail adapter that is fastened with 4 screws and attach it on the side of the power supply. Screwdriver: Torx T10 Tightening torque: 0.7 w0.1 Nm 2CDC 273 005 F0015 2CDC 273 008 F0015 Data sheet Power supply 24/20.0; product revisions < D - 7

Demounting To release the power supply pull the latching lever downwards with a screwdriver and press the upper side of the the latching lever down. The device can be unhinged from the DIN rail and removed. 2CDC 273 003 F0015 Electrical connection Connect the input terminals " to line and "N" to neutral conductor or to + and - with DC supply "+" to "" and "-" to "N". The protective earth conductor PE must be connected before putting the device into operation. The installation must be executed acc. to EN 60950. Provide a suitable disconnecting device (e. g. line protection switch, MCB or fuse) in the supply line. The input side of the power supply is protected by an internal input fuse. The wiring, cable choice and their protection shall comply to the local electrical standard. We recommend choosing the conductor cross-section as large as possible in order to minimize voltage drops. Check the polarity. The device is overload, short-circuit and open-circuit proof. The secondary side of the power supply is electrically isolated from the input and internally not earthed (SEV) and can be earthed for PEV. + + - - + N PWM - PE N o Connection diagram 2CDC 272 014 272 F0004 014 F0b04 +, Output voltage, N Input voltage o Protective earth (PE) 24 and 48 V DC connection The connection diagram below shows how to setup two power supplies for +/-24 or 48 V DC output voltage. + +24 V 48 V + -24 V 2CDC 272 012 F0015 Connection diagram for +/-24 or 48 V DC output voltage 8 - Power supply 24/20.0; product revisions < D Data sheet

Connection to TN, TT networks The user must refer to and the installation comply with local electrical codes. The power supply can be connected to electrical supply systems with various earthing systems according to the diagrams below. N PE N PE Earth N PE 2CDC 272 018 F0216 N 2CDC 272 019 F0216 TN-S 1-phase DC source, e.g. battery N PE N PE Earth PEN 2CDC 272 020 F0216 Earth Earth N 2CDC 272 021 F0216 TN-C 1-phase TT 1-phase In AC networks the input voltage range is defined by -15...+10 % of the rated input voltage. However, in DC networks the rated input voltage is equal to the input voltage range. Data sheet Power supply 24/20.0; product revisions < D - 9

Safety instructions and warnings In operation pay attention to: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)! Risk of burns: Depending on the operation conditions the housing can become hot. The device contains no user serviceable parts. In any case of device malfunction please send the unit back to manufacturer. The device must be installed by qualified persons only and in accordance with the specific national regulations (e. g. VDE, etc.). The CP C.1 is a chassis mounted unit. It is maintenance free and does not contain any integral setting elements and should therefore not be opened. Before any installation, maintenance or modification work: Read the operating and installation instructions carefully and completely! Disconnect the system from the supply network and protect against switching on! Before start of operation the following must be ensured: Connection to mains or DC supply according to the specific national regulations for class of protection I. Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the end product to disengage unit and supply cables from supply mains if required. The protective earth conductor must be connected to the terminal PE. Rate the output lines for the output current of the power supply and connect them with the correct polarity. In order to ensure sufficient convection the distance to the other devices has to be considered. Attention! Improper installation/operation may impair safety of personnel and cause operational difficulties or destruction of the unit. Attention! Danger to life! Disconnect the system from the supply network before executing any works at the device and protect against switching on! The power supply contains components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. If the internal fuse is blown most probably the device is defect. In this case an examination of the device by the manufacturer is necessary. 10 - Power supply 24/20.0; product revisions < D Data sheet

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, typical values unless otherwise indicated Input circuit - Supply circuit (+), N (-) Rated input voltage U in 100-240 V AC, 90-250 V DC Input voltage range AC 85-264 V AC Typical input current at 115 V AC 4.6 A DC at 230 V AC 90-250 V DC 2.3 A Typical power consumption at 230 V AC 508 W Rated frequency AC DC, 50/60Hz Frequency range Inrush current limiting, cold state et-trough energy I 2 t, cold state Discharge current towards PE at 230 V AC 45-65 Hz < 30 A < 3.5 ma Hold-up time at 115 V AC min. 40 ms Internal input fuse at 230 V AC min. 40 ms T12A, not exchangeable Recommended backup fuse for wire protection at 1 pole miniature circuit breaker ABB type S 200 1.5 mm 2 characteristic B or C Power factor correction (PFC) Transient overvoltage protection User interface Indication of operational states max. rating 16 A yes, active yes, varistor Output voltage ED OUTPUT OK (green) ON 92 % adjusted U out Flashing 90 % adjusted U out Power reserve ED I > I R yellow OFF I I R ON I > I R Output circuit - Power output Rated output voltage +, - 24 V DC Tolerance of the output voltage ± 1 % Adjustment range of the output voltage Rated output power 22.5-28.5 V DC 480 W Rated output current I R - 25 C m T a m 60 C 20 A Reserve output current - 25 C m T a m 40 C 26.0 A continuously Short-circuit current limiting 27.7 A Derating of the output current 60 C < T a m 70 C 3.5 %/ C Deviation width of output voltage load change statical 10-90 % < 1 %, class C acc. to IEC/EN 61204 dynamical 0-100 % < 5%, class B acc. to IEC/EN 61204 change of input voltage within the rated input voltage < 5 ms, class B acc. to IEC/EN 61204 Control time at rated load < 0.1 %, class A acc. to IEC/EN 61204 Starting time after applying the supply voltage at rated load < 500 ms, class C acc. to IEC/EN 61204 with 3500 µf Rise time at rated load < 10 ms Fall time with 3500 µf < 20 ms Residual ripple and switching peaks BW = 20 MHz < 120 mvpp, class A acc. to IEC/EN 61204 Parallel connection Series connection yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical yes, max. 2 devices to increase voltage Data sheet Power supply 24/20.0; product revisions < D - 11

No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection No-load protection Starting of capacitive loads U/I characteristic curve with power reserve continuous short circuit stability current limiting 35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart continuous no-load stability yes Signaling outputs OUTPUT OK signaling output Type of output 13-14 relay, n/o contact ON (contact closed) 92 % adjusted U out OFF (contact open) 90 % adjusted U out Contact ratings max. switching voltage / current 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 ma POWER RESERVE signaling output Type of output I > I R transistor, short-circuit proof Active / ON (closed) I > I R Inactive / OFF (open) I I R Ratings voltage/current 24 V DC / 20 ma General data Efficiency at rated output power up to 94 % Power loss at rated output power 28 W at 50% of rated output power 17 W at no load < 3.6 W Duty time 100% MTBF acc. to MI 217 HDBK on request Dimensions see Dimensional drawings Material of housing cover zinc-coated sheet-steel housing shell aluminium front plastic, PA6, V-0 Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position 1,7 Minimum distance to other units horizontal 25 mm (0.98 in) vertical 25 mm (0.98 in) Degree of protection (IEC/EN 60529) housing / terminals IP20 / IP20 Protection class (EN 61140) I Electrical connection Input circuits ((+), N(-), o/pe) Connecting capacity rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) Stripping length 8 mm (0.315 in) Tightening torque 0.5 Nm (4.4 lb.in) Recommended screw driver PH1 / Ø 4.0 x 0.8 mm 12 - Power supply 24/20.0; product revisions < D Data sheet

Output circuits (+, +, -, -) Connecting capacity rigid 2.5-16.0 mm² (12-6 AWG) Stripping length Tightening torque Recommended screw driver fine-strand with(out) wire end ferrule 2.5-10 mm² (12-8 AWG) 10 mm ( 0.394 in) 1.2 Nm (10.5 lb-in) PH1 / Ø 4.0 x 0.8 mm Signaling output (13-14, I > I R ) Connecting capacity rigid 0.5-4.0 mm² (20-10 AWG) Stripping length Tightening torque Recommended screw driver Maximum cable length (applicable for I>Ir) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm 30 m Environmental data Ambient temperature range operation -25 +70 C (-13... +158 F) rated output power -25...+60 C (-13... +140 F) storage -40 +85 C (-40...+185 F) transportation -40 +85 C (-40...+185 F) Climatic class (IEC/EN 60721-3-1) storage Climatic class (IEC/EN 60721-3-2) transportation Climatic class (IEC/EN 60721-3-3) operation 3K3 (-25 +70 C / -13... +158 F) Damp heat, cyclic (IEC/EN 60068 2 30) Test Db: 55 C, 2 cycles Vibration, half sine (IEC/EN 60068 2 6) Shock, half sine (IEC/EN 60068 2 27) Altitude without restriction 2000 m Isolation data Rated impulse withstand voltage U imp (EN 50178) input circuit / output circuit 4 kv (1.2/50 µs) input circuit / PE 4 kv (1.2/50 µs) input circuit / relay contact 4 kv (1.2/50 µs) output circuit / relay contact 0.5 kv (1.2/50 µs) relay contact / PE 0.5 kv (1.2/50 µs) output circuit / PE 0.5 kv (1.2/50 µs) Rated insulation voltage U i (EN 50178) input circuit / output circuit 300 V input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V relay contact / PE 50 V output circuit / PE 50 V Overvoltage category (EN 50178) < 2000m III 2000 5000m II Overvoltage category (IEC/EN 60950-1) < 2000m II 2000 5000m I Pollution degree 2 Protective separation (IEC/EN 60950-1) input circuit / output circuit Yes input circuit / relay contact Yes Data sheet Power supply 24/20.0; product revisions < D - 13

Standards Product standard IEC/EN 61204 ow Voltage Directive 2006/95/EC (valid until 19 April 2016) / 2014/35/EU (valid from 20 April 2016) EMC directive 2004/108/EC (valid until 19 April 2016) / 2014/30/EU (valid from 20 April 2016) RoHS directive 2011/65/EC Electrical safety IEC/EN 60950-1 Industrial control equipment U 508 / CSA 22.2 No 107.1 Electronic equipment for use in power installations EN 50178 Protective extra low voltage PEV (EN 50178) Safety extra low voltage SEV (IEC/EN 60950-1) imitation of harmonic line currents IEC/EN 61000-3-2 Electromagnetic compatibility ow-voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) IEC/EN 61204-3 Interference immunity to IEC/EN 61000-6-1 and IEC/EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 evel 4, 8 kv / 15 kv radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 evel 3, 10 V/m electrical fast transient / burst IEC/EN 61000-4-4 evel 4, 4 kv surge IEC/EN 61000-4-5 evel 3: -N 2 kv, evel 4: /N-PE 4 kv conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 evel 3, 10 V power frequency magnetic fields IEC/EN 61000-4-8 30 A/m (A) damped oscillatory magnetic fields IEC/EN 61000-4-10 evel 4, 30 A/m (to be confirmed) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 Class 3 ring waves IEC/EN 61000-4-12 harmonics and interharmonics IEC/EN 61000-4-13 Class 3 (to be confirmed) conducted, common mode disturbances in the frequency range 0 Hz to 150 khz IEC/EN 61000-4-16 damped oscillatory waves IEC/EN 61000-4-18 evel 3, 10 V (to be confirmed) Interference emission IEC/EN 61000-6-4 limits for harmonic current emissions IEC/EN 61000-3-2 Class A limitation of voltage changes ect. IEC/EN 61000-3-3 Information technology equipment radio disturbance characteristics limits and methods of measurement Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement IEC/CISPR 22, EN 55022 IEC/CISPR 11, EN 55011 Class A Class A Voltage sags SEMI F47 passed Federal Communications Commission FCC15 compliant 14 - Power supply 24/20.0; product revisions < D Data sheet

Technical diagrams Data at T a = 25 C, U in = 230 V AC and rated values, typical values unless otherwise indicated Efficiency diagrams The efficiency and thus the power loss depends on the output current, input voltage, output voltage and ambient temperature as illustrated in the diagrams below. Efficiency [%] Power loss [W] 40 95.0 30 90.0 20 85.0 80.0 5 10 15 20 25 I out [A] 2CDC 272 003 F0216 10 0 0 4 8 12 16 20 24 I out [A] 2CDC 272 005 F0216 Typical efficiency over output current Typical power loss over output current Efficiency [%] 94.5 94.0 93.5 93.0 92.5 Power loss [W] 40 35 30 92.0 91.5 85 110 130 150 170 190 210 230 250 U in [VAC] 2CDC 272 006 F0216 25 85 110 130 150 170 190 210 230 250 U in [VAC] 2CDC 272 007 F0216 Typical efficiency over AC input voltage Typical power loss over AC input voltage Efficiency [%] 94.5 94.0 at 100% load at 150% load 93.5 93.0 92.5 92.0-25 -15-5 5 15 25 35 45 55 65 T a [ C] 2CDC 272 008 F0216 Typical efficiency over ambient temperature Data sheet Power supply 24/20.0; product revisions < D - 15

Characteristic curve of output Output voltage [V] 30 25 20 15 10 5 0 0 4 8 12 16 20 24 28 32 34 Output current [A] at 24 V at 22.5 V at 28.5 V Characteristic curve of output at T a = 25 C 2CDC 272 019 F0015 Characteristic curve of temperature Output current [A] 32 28 24 20 16 12 8 4 0 I R Power reserve -25-10 0 10 20 30 40 50 60 70 Ambient temperature [ C] Characteristic curves of temperature at U out = 24 V, mounting position 1 2CDC 272 022 F0015 The switch mode power supply is able to supply at 24 V DC output voltage and at an ambient temperature of 40 C a continuous output current of typ. 26 A 60 C the rated current of 20 A With mounting position 1 and at ambient temperatures of > +60 C the output power has to be reduced by 2.5 % per Celcius degree temperature increase. Deratings for other mounting positions on request. At thermal overload the device will switch-off as soon as the internal temperature exceeds the acceptable level. The exact ambient temperature threshold depends on the mounting position and load of the power supply. If the switch mode power supply is loaded with an output current > 26 A, the operating point is passing through the U/I characteristic curve shown. The device is equipped with an overtemperature protection function. It will switch-off as soon as the internal overtemperature protection function is activated. 16 - Power supply 24/20.0; product revisions < D Data sheet

PWM PWM PWM Dimensions in mm and inch 129.8 5.11" 126.8 4.99" 40.00 1.57" 60.00 2.36" 82.00 3.23" 13 14 I > I R + + - - 13 14 I > I R + + - - 13 14 I > IR + + - - OUTPUT 24 V DC 10 A OUTPUT 24 V DC 20 A OUTPUT 24 V DC 5 A 24/5.0 24/10.0 24/20.0 IEC/EN 60715 TH 35-7.5 TH 35-15 OUTPUT OK POWER RESERVE I > I R OUTPUT Adjust 22.5-28.5 V N + + - - 129.4 5.09" OUTPUT Adjust 22.5-28.5 V N OUTPUT OK POWER RESERVE I > I R + + - - 129.4 5.09" N OUTPUT OK POWER RESERVE I > I R OUTPUT Adjust 22.5-28.5 V + + - - 129.4 5.09" 136.0 5.35" INPUT 100-240 V AC (+) N(-) 24/5.0 INPUT 100-240 V AC (+) N(-) 24/10.0 INPUT 100-240 V AC (+) N(-) 24/20.0 2DCDC 272 028 F0015 Further documentation Document title Document type Document number Electronic relays and controls Technical catalogue 2CDC 110 004 C02xx Instruction manual 1SVC 360 560 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, Control and Protection -> Electronic relays and controls -> Power supplies. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> ow Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. Data sheet Power supply 24/20.0; product revisions < D - 17

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> ow Voltage Products and Systems Document number 2CDC 114 094 D0201 (12.2016) egal note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2016 ABB All rights reserved