DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC

Similar documents
Featuring TJ Rim Board and TimberStrand LSL

CITY OF LOS ANGELES CALIFORNIA

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Chapter 6 ROOF-CEILING SYSTEMS

ICC-ES Evaluation Report

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

POST AND FRAME STRUCTURES (Pole Barns)

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

LP OSB Sheathing & Structural 1 Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Residential Deck Safety, Construction, and Repair

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

PERFORMANCE RATED I-JOISTS

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Residential Decks. Planning and Development Services Department

Discipline: Structural Issued

Formwork for Concrete

Post and Beam Construction

STANDARD OPEN PATIO COVER

Nanping Weishi LVL Scaffold Plank Brochure

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Typical Deck Details

Code of Standard Practice for Timber Frame Structures

Owner s Guide to Understanding Checks in Glued Laminated Timber

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Uncovered Decks & Porches

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

2015 UCC Residential Code Update

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

MUNICODE SERVICES LTD.

NORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC JOISTTM FSC-CERTIFIED PRODUCTS AVAILABLE

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Bracing Webs in Trusses that have Dissimilar Configurations

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Section 5A: Guide to Designing with AAC

Building Construction. Lightweight construction. Conventional Construction

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

SECTION 1 GENERAL REQUIREMENTS

Chapter 3 Pre-Installation, Foundations and Piers

RPS - sales@rpssolar.com San Bruno Cove, San Diego, CA 92130

B. Related categories: The following categories contain requirements that relate to this section:

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Breakaway Walls

March 14, Installation of Bay, Bow and Garden Windows

TYPICAL PATIO COVERS 111

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Page & Turnbull imagining change in historic environments through design, research, and technology

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

December J-Ply Roofing, Flooring and Decking

Section A Roof Truss

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

Perforated Shearwall Design Method 1

Design Approach: 3) Full Sawn: In this case a rough surface is obtained with actual size equal to the nominal size.

Patio Covers / Carports

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

6 RETROFITTING POST & PIER HOUSES

FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

CHAPTER 6 CONSTRUCTION TYPES

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Detailing of Reinforcment in Concrete Structures

COMMONLY USED RESIDENTIAL BUILDING CODES

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Diaphragms and Shear Walls DESIGN/CONSTRUCTION GUIDE

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Fire-Retardant-Treated (FRT) Plywood

Fastener Loads for Plywood Screws Number E830D August 2005

Eurocode 5: Design of timber structures

SECTION GUARDRAILS

USP SIP Connection Manual

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Superform Products Ltd.

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

ATI Evaluation Service A Division of Architectural Testing Certification Services

AUTHORIZATION TO MARK

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

INTRODUCTION STRUCTURAL DESIGN

Transcription:

0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 8 () 99 0 www.icc es.org ESR 99 Reissued 0/0 This report is subject to renewal 0/09. DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 0 LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC 00 EAST MALLARD DRIVE BOISE, IDAHO 80 EVALUATION SUBJECT: STRUCTURAL COMPOSITE LUMBER: REDLAM LAMINATED VENEER LUMBER (LVL) Look for the trusted marks of Conformity! 0 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the Copyright 0 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) -8 () 99-0 ESR-99 Reissued January 0 This report is subject to renewal January 09. A Subsidiary of the International Code Council DIVISION: 0 00 00 WOOD, PLASTICS AND COMPOSITES Section: 0 Laminated Veneer Lumber REPORT HOLDER: REDBUILT LLC 00 EAST MALLARD DRIVE BOISE, IDAHO 80 (8) 89- www.redbuilt.com ADDITIONAL LISTEE: BOISE CASCADE WOOD PRODUCTS, LLC POST OFFICE BOX 00 WHITE CITY, OREGON 90-000 EVALUATION SUBJECT: STRUCTURAL COMPOSITE LUMBER: REDLAM LAMINATED VENEER LUMBER (LVL).0 EVALUATION SCOPE Compliance with the following codes: 0, 009 and 00 International Building Code (IBC) 0, 009 and 00 International Residential Code (IRC) Properties evaluated: Structural Fire resistance.0 USES The structural composite lumber (SCL) products described in this evaluation report are used as alternatives to sawn lumber for wall, floor and roof structural members, and are as defined in Chapter of the 0 IBC, Chapter of the 009 and 00 IBC, and Chapter of the 0 IRC. These structural applications include use as beams, headers, joists, rafters, columns, and rim boards. The products are also used as components of built-up structural members, such as flanges for I-joists and chords for trusses, as detailed in a current ICC-ES evaluation.0 DESCRIPTION. General: The structural composite lumber (SCL) described in this report is an alternative material to that described in Chapter of the IBC, and complies with the requirements noted in Sections 0..9 and 0.. of the IBC for allowable stress design. Section 08 of the IBC and Chapters, and 8 of the IRC are applicable to the SCL described in this. Rim Board: The rim board product described in this evaluation report is a continuously supported structural element located at the joist elevation in an end bearing wall or parallel to the joist framing that is the full depth of the joist space and manufactured in minimum continuous 8-foot-long (. m) segments for the length of the wall. The rim boards may be used for any combination of the following: a. To transfer, from above to below, all vertical loads at the rim board location. Allowable vertical loads are noted in Table. b. To provide diaphragm attachment (sheathing to top edge of rim board). c. To transfer in-plane lateral loads from the diaphragm to the wall plate below. d. To provide lateral support to the joist or rafter (resistance against rotation) through attachment to the joist or rafter. e. To provide closure for ends of joists or rafters. f. To provide an attachment base for siding or an exterior deck ledger. The rim board properties and species, adhesive, manufacturing parameters, and finished product thickness, width and length meet the requirements noted in the approved quality control manual that contains the manufacturing standard.. RedLam LVL: RedLam LVL is manufactured from veneers of a single wood species, or species combination, and adhesives meeting the requirements specified in the approved quality control manual and manufacturing standard prepared by RedBuilt. During manufacture, the veneers are placed in a continuous-feed press, and the veneers are bonded together with an approved adhesive. RedLam LVL is available in thicknesses from / inch (9. mm) to inches (8 mm), depths from / inches (. mm) to inches (0 mm), and lengths up to 80 feet ( 80 mm)..e RedLam LVL is available in depths up to 8 inches (9 mm).. RedLam LVL Rim Board: RedLam LVL rim board may be used in rim board application, as defined in Section.. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the Copyright 0 ICC Evaluation Service, LLC. All rights reserved. Page of 000

ESR-99 Most Widely Accepted and Trusted Page of.0 DESIGN AND INSTALLATION. General: The design and installation of RedBuilt structural composite lumber must comply with this report and the manufacturer s published installation instructions. The manufacturer s published installation instructions must be available at the jobsite at all times during installation. Design of the structural composite lumber products described in this report is governed by the applicable code and the ANSI/AF&PA National Design Specification for Wood Construction (NDS). This report governs if there are conflicts between the manufacturer s published installation instructions and this. RedLam LVL:.. Design and Allowable Stresses: The design provisions for wood construction noted in Section 0.() of the IBC (for allowable stress design) and Section R0.. of the IRC, are applicable to RedLam LVL, unless otherwise noted in this Reference design values, sizes and veneer species for RedLam LVL for dry conditions of use are specified in Table of this Unless otherwise noted, adjustment of the design stresses for duration of load must be in accordance with the applicable code. Reference withdrawal and lateral design values for nails installed perpendicular or parallel to the wide face of RedLam LVL are as prescribed in the applicable code for sawn lumber having a minimum specific gravity of 0.0, such as for Douglas fir larch. Minimum spacings of nails installed perpendicular to the glue lines on the wide face of RedLam LVL must be as prescribed in Chapter of the ANSI/AF&PA National Design Specification for Wood Construction (NDS), for sawn lumber. Minimum spacing, end distance and edge distance of nails and staples installed parallel to the glue lines on the narrow face of the material must be as prescribed in Table of this Other nail spacings for specific applications, such as prefabricated steel components or hangers, may be used as detailed for RedLam LVL in a current ICC-ES evaluation Reference lateral design values for machine bolts installed perpendicular to the wide face of RedLam LVL (perpendicular to the glue lines), with loads applied parallel or perpendicular to the grain of the wood veneers, are as prescribed in the applicable code for sawn lumber having a minimum specific gravity of 0.0, such as for Douglas fir larch... Fire-Resistance: The provisions of IBC Sections.. (0 IBC) and.. (009 and 00 IBC), on design of fire-resistant exposed wood members, are applicable to RedLam LVL, provided the LVL members have minimum cross-sectional dimensions of. inches by. inches (0 mm by 0 mm)... RedLam LVL Rim Board: Toenailed connections are not limited by the 0 plf (89 N/m) lateral load capacity noted for Seismic Design Categories D, E and F in Section 0.. of the 00 IBC and Section.. of the ANSI/AF&PA Special Design Provisions for Wind and Seismic (SDPWS). The ability of RedLam LVL to transfer shear is as described in Footnote to Table of this.. Fire-Blocking: RedLam LVL Rim Board, having a minimum thickness of. inches ( mm), may be used in lieu of sawn lumber for fire blocking..0 CONDITIONS OF USE The RedLam LVL Structural Composite Lumber products described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section.0, subject to the following conditions:. Design stresses must comply with the values noted in this. Design calculations and details must be furnished to the code official, verifying that the material is used in compliance with this The calculations must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed.. RedLam LVL products described in this report must be limited to covered end-use installations with dry conditions of use. Dry conditions of use are those environmental conditions represented by sawn lumber in which the equilibrium moisture content is equal to or less than percent. The use of these products in covered installations, where the moisture content exceeds percent, has not been reviewed and is beyond the scope of this evaluation. Increases for duration of load, as provided for wood members and their connections, must be in accordance with the limitations specified in the applicable code and as set forth in this report, unless specifically prohibited by this. Where flexural bending members qualify as repetitive members, as defined in the NDS, an increase of percent is permitted in reference bending design values.. Length dimensions of RedLam LVL may be cut to size for required application. Depth must not be cut to less than / inches (89 mm). For all material used in structural applications, the product identification described in Section.0 must be maintained on all material, or the material must be re-stamped with the appropriate identification. Additionally, RedLam LVL may be notched, drilled, or tapered-end cut provided the design for such is by a registered design professional.. Installation, fabrication, identification, and connection details must be in accordance with this report, the manufacturer s published installation instructions and the applicable code..8.e through.e RedLam LVL is produced at the RedBuilt plant in Stayton, Oregon, under a quality control program with inspections by ICC-ES and PFS Corporation (AA-)..9.E RedLam LVL is produced at the Boise Cascade Wood Products plant in White City, Oregon, under a quality control program with inspections by ICC-ES and PFS Corporation (AA-)..0 EVIDENCE SUBMITTED. Data in accordance with the ICC-ES Acceptance Criteria for Structural Wood-based Products (AC), dated February 0 (editorially revised February 0).. Data in accordance with the ICC-ES Acceptance Criteria for Rim Board Products (AC), dated February 0.. Reports of fire tests conducted in accordance with ASTM E9.

ESR-99 Most Widely Accepted and Trusted Page of.0 IDENTIFICATION RedLam LVL is identified with a stamp bearing the manufacturer s name (RedBuilt ) and/or logo (see Figure ), the name or logo of the inspection agency (PFS Corporation), as applicable, the evaluation report number (ESR-99), the plant number, the product designation or type, the production date, the grade, and the species or species group designation. The product designation may be either RedLam LVL or RedBoard. RedLam LVL is also identified with the marking AGS following the grade designation, if the advanced grading system specified in the approved quality control manual was used in the manufacturing process. TABLE REFERENCE DESIGN VALUES FOR REDLAM LVL (ALLOWABLE STRESS DESIGN), (pounds per square inch) AXIAL JOIST/BEAM PLANK BILLET GRADE MATERIAL SPECIES 0 E E min THICKNESS, F t F c F b F v (x0^) (x0^) F c 8 9 9 8 F b F v F c.e DF/LP/WH 9 00 800. 0.8 800 0 0.E DF/LP/WH 0 00 0 8. 0.9 0 0 90 80.8E DF/LP/WH 0 8.8 0.9 0 890 90 80.9E DF/LP/WH 0 00 8.9.0 0 0 90 80 / inch.0e DF/LP/WH 0 0 8.0.0 0 90 80 to.0e-900f b DF/LP/WH 0 900 8.0.0 0 0 90 80 inches.e DF/LP/WH 0 980 8.. 0 90 80.E DF/LP/WH 8 80 00 8.. 0 90 80.E DF/LP/WH 90 9 8.. 0 800 90 80.E DF/LP/WH 0 080 8.. 0 980 90 80.E DF/LP/WH 8 0 8.. 0 90 80 For SI: psi = 0.0089 MPa, inch =. mm. Reference design values are based on covered, dry conditions of use and normal load duration. Dry conditions of use are those environmental conditions represented by sawn lumber at which the moisture content is less than or equal to %. For uniformly loaded simple span beams, deflection is calculated as follows: 0WL 8. 8WL Ebd Ebd where: W = Uniform load, plf b = Beam width, inches = Deflection, inches d = Beam depth, inches L = Span, feet E = Modulus of Elasticity, psi DF = Douglas fir larch; LP = lodgepole pine; WH = Western hemlock; DF, LP and WH are permitted to be combined as Western Species (WS). The F t values in the table are reduced to reflect the volume effects of length, width and thickness for a range of common application conditions. Therefore the F t values in the Table do not apply to RedLam LVL when used as a component of engineered products manufactured by RedBuilt which are listed in ICC-ES evaluation reports. F b includes allowances for variations in span to depth ratio and method of loading and must be used without further adjustment except as noted below. For depths other than inches, regardless of thickness, table values must be multiplied by (/d) 0.. Adjustments for common depths are shown below. For depths less than. inches, the factor for the.-inch depth must be used. Depth... 9. 0 Multiplier.8..0.0.00 0.9 0.9 0.9 When structural members qualify as repetitive members in accordance with the applicable code, a percent increase in accordance with NDS is permitted, in addition to the increases permitted in Footnote, above. This increase does not apply to field assembled multi-member beams. For simplicity, use 8 psi for depths up to inches and 0 psi for depths greater than inches. When a more accurate analysis is desired, the reference horizontal shear design value for all depths greater than inches is Fv = 8 (/d) 0.0 psi. 8 Compression perpendicular to grain values (F c ) may not be increased for duration of load. 9 Values shown are for thicknesses up to. inches (in the direction perpendicular to the veneer faces). Tabulated plankwise bending, F b, and shear, F v, do not apply to LVL thicker than. inches. 0 E min is the reference modulus of elasticity for beam stability and column stability calculations.

ESR-99 Most Widely Accepted and Trusted Page of TABLE MINIMUM ON-CENTER SPACING OF NAILS AND STAPLES DRIVEN INTO THE EDGE OF REDLAM LVL,, (For Fasteners Oriented Parallel to the Gluelines) FASTENER MINIMUM SPACING (inches) RedLam LVL Thickness, t (inches) / t < / / t < / / t / Row Row Rows (,) Row Rows (,) 8d Common Nail 0d Common Nail d Common Nail d Common Nail -- 8 () 8 () 8 () 8 () No. gage staple -- -- For SI: inch =. mm. Minimum end distances must be / inches for 8d common nails, and inches for all other sizes. Minimum edge distance must be / 8 inch. Minimum spacings apply to LVL members having a minimum depth (dimension parallel to fastener axis) of / inches for one fastener row and / inches for multiple fastener rows. Multiple rows of fasteners must be staggered by half the distance between fasteners in a row, and the minimum spacing between rows must be / inch. Multiple rows must be equally spaced about the centerline. Spacing may be reduced to inches on center where nail penetration does not exceed / 8 inches into the edge of the LVL. GRADE MINIMUM THICKNESS (inches) TABLE REDLAM LVL RIM BOARD,,,, DEPTH RANGE (inches) CONTAINS CROSS PLIES ALLOWABLE VERTICAL LOAD (plf). /.E and Higher 8 No 0.0 d No 0.0 d Yes 80.E.0 d Yes 00 For SI: inch =. mm; plf +.9 N/m. The allowable shear values in pounds per foot for horizontal wood structural panel diaphragms with framing of nominally -inch-thick Douglas fir larch or Southern pine sawn lumber noted in Table.A and Table.C of the ANSI/AF&PA Special Design Provisions for Wind and Seismic (SPDWS), Table 0.() of the 0 IBC and Table 0..() of the 009 IBC and Table 0.. of the 00 IBC are applicable to: ().-inch-thick RedLam LVL rim board for unblocked diaphragms only, and ().0-inch-thick and thicker RedLam LVL rim board for unblocked and blocked diaphragms. Nail spacing must be sufficient to prevent splitting, or as specified in Table, whichever is more restrictive. RedLam LVL rim board must be laterally supported at the top and continuously supported at the bottom, and the gravity loads must be uniformly applied along the top, in lieu of design by a design professional or other conditions Fastener capacities for RedLam LVL rim board are as recognized in Section.. of this report, except as provided in footnote, below. Compression perpendicular to grain capacities of the sill plate and floor sheathing must be checked. The allowable perpendicular-to-grain lateral load capacity of a / -inch-diameter lag screw connection installed perpendicular to the veneers, with full penetration through RedLam LVL having a grade of.e or higher, and supporting a / -inch-thick deck ledger having a minimum specific gravity of 0.0, is lbs. Toe-nailed connections between the rim board and supporting member are not limited by the 0 plf lateral load capacity noted for Seismic Design Categories D, E and F in Section.. of the ANSI/AF&PA SDPWS and Section 0.. of the 00 IBC. LVL members with cross plies consist of veneers oriented 90 degrees from the main orientation of veneers. FIGURE MANUFACTURER LOGO