TECHNICAL DATA OBSOLETE

Similar documents
Quick response concealed horizontal sidewall sprinkler

esfr pendent sprinkler vk510 (k25.2)

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Viking Residential Sprinkler Installation Guide

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model F1FR Series Quick Response Glass Bulb Sprinklers

Model KFR56 Series Quick Response Standard Spray

Sprinkler Identification Numbers

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Viking Residential Sprinkler Installation Guide

Extended Coverage Sprinklers

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Model/Sprinkler Identification Numbers

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Sprinkler Guards Model C Model D

TECHNICAL DATA. Dry 122a. November 12, 2013

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

HIGH VELOCITY WATER SPRAY NOZZLE

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Sprinkler Identification Numbers (SINs) Technical Data

Select Radiators Installation Guide

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Engineering Specifications

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

C I T Y O F S E L M A F I R E D E P A R T M E N T

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat

Your safety and the safety of others are very important.

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

A99B Series Temperature Sensors

08.08 Vic-Check Valves

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

! WARNING. Before using product, read and understand instructions.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Technical Article. Sprinkler Protection for High Bay and Automated Storage in Warehouse-Type Storage Facilities

CEILING CASSETTE FAN COIL UNIT

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

Installation Instructions

MODEL J SERIES CONVERTER

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Toroidal Conductivity Sensor

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

EFSN Training i Module Minutes

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Stainless Steel Single and Dual Circulation Kits

Technical Data. Installation

FIVE YEAR CERTIFICATION REPORT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Many Products...One Source

Antifreeze Solutions in Residential Fire Sprinkler Systems

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Installer s Guide 18-AH39D1-13

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation Manual DIAPHRAGM WELL TANK

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

IMPORTANT DOCUMENTATION DO NOT DISCARD!

GAS SAFETY PRECAUTIONS

Float and Thermostatic Traps Series H, C and X

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

FOAM CHAMBER MODEL - FC

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Machine Nozzles Injection Nozzle

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

How To Install An Evaporator Coil

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Model 43AP Pneumatic Controller, Style B

BERMAD Fire Protection

NFPA31FuelOilPiping 1 Revised

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

Transcription:

August 1, 2008 Sprinkler 127a 1. DESCRIPTION Viking Flat Spray Pendent Sprinklers VK920 and VK922 are small, thermosensitive, glass-bulb sprinklers intended for installation in accordance with local standards. They produce a flatter spray pattern than standard spray sprinklers, allowing them to be used with lower clearance above suspended open ceillings, in racks, and concealed spaces. Sprinklers VK920 and VK922 are VdS approved with a Brass or Chrome-Enloy finish, with various temperature ratings, and a nominal K-Factor of 5.6 (80 metric) or 8.0 (115 metric) to meet design requirements. 2. LISTINGS AND APPROVALS VdS Approved: Certificate # Refer to the Approval Chart on page 127c and Design Criteria on page 127e for VdS approval requirements that must be followed. 3. Specifications: Available since 2008. Minimum Operating Pressure: Refer to CEA 4001 or EN12845. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2 (15 mm) or 3/4 (20 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) or 8.0 U.S. (115.2 metric*) Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length: 2-1/4 (58 mm) for Sprinkler VK920, 2-5/16 (59 mm) for Sprinkler VK922 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Sprinkler VK920 (K80) and VK922 (K115) Ordering Information: (Also refer to the current Viking price list.) Order Flat Spray Pendent Sprinklers VK920 and VK922 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy = F Temperature Suffix ( F/ C): 155 /68 = B, 175 /79 = D, 200 /93 = E For example, sprinkler VK920 with a Brass finish and a 155 F/68 C temperature rating = Part No. 15111AB Available Finishes and Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Form No. F_072508 New page 127a-e, issued August 1, 2008.

Sprinkler 127b August 1, 2008 4. INSTALLATION The sprinklers are designed to be installed in accordance with recognized installation standards. Viking Flat Spray Pendent Sprinklers must be installed in accordance with the latest edition of Viking technical data, CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems - Design, Installation, and Maintenance, the Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. A. Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped or damaged in any way or exposed to temperatures exceeding the maximum ambient temperature allowed (refer to Table 1). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb should be destroyed immediately. B. Wet pipe systems must be provided with adequate heat. C. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. D. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. E. With the sprinkler contained in the plastic protective shield, apply a small amount of pipe-joint compound or tape to the male threads only, while taking care not to allow a build-up of compound in the sprinkler orifice. F. Install the sprinkler on the piping using special sprinkler wrench 10896W/B only, while taking care not to damage the sprinkler operating parts. (Any other type of wrench may damage the unit.) DO NOT use the sprinkler deflector to start or thread the sprinkler into a fitting. G. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Immediately replace any damaged units, using the special sprinkler wrench only. Figure 1: Standard Sprinkler Wrench 10896W/B TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating 1,2 Bulb Color Ordinary 155 F (68 C) Red Intermediate 175 F (79 C) Yellow Intermediate 200 F (93 C) Green Sprinkler Finishes: Brass or Chrome-Enloy Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Sprinklers shall be chosen with a temperature rating close to but not lower than 30 C above the highest anticipated ambient temperature. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards.

August 1, 2008 Sprinkler 127c Sprinkler Base Part No. 1 Sprrinkler Style SIN Thread Size Approval Chart Flat Spray Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Nominal K-Factor Overall Length Listings and Approvals 3 (Refer also to Design Criteria on page 127e.) fire. NPT BSP U.S. metric 2 Inches mm culus FM VdS LPCB Standard Orifice 15111 Pendent 3 VK920 1/2 15 mm 5.6 80.6 2-1/4 58 -- -- A1 -- -- -- Large Orifice 15112 Pendent 3 VK922 3/4 20 mm 8.0 115.2 2-5/16 59 -- -- A1 -- -- -- Approved Temperature Ratings Approved Finishes A - 155 F (68 C), 175 F (79 C), and 200 F (93 C) 1 - Brass and Chrome-Enloy Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Figure 2: Sprinkler Dimensions to extinguish or control the H. After installation and testing and repairing of all leaks, remove the protective shields from the sprinklers. To remove the shield, simply pull the ends of the shield apart where it is snapped together. THE SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! I. If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See section 6. INSPECTIONS, TESTS, AND MAINTENANCE and follow all warnings and instructions. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern

Sprinkler 127d August 1, 2008 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the appropriate standard that describes care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. Sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. The frequency of the inspections may vary due to corrosive atmospheres, water supplies, and activity around the device. B. Sprinklers that have been painted, caulked, or mechanically damaged must be replaced immediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested, and if necessary, replaced after a specified term of service. Refer to the installation standards and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or re-used, but must be replaced. When replacing sprinklers, use only new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. 2. Using the special sprinkler wrench, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response characteristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Follow instructions in section 4. INSTALLATION. 3. Place the system back in service and secure all valves. Check for and repair all leaks. E. Sprinkler systems that have been subjected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking Flat Spray Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

August 1, 2008 Sprinkler 127e VdS Approval Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 127c.) Flat Spray Sprinklers VK920 and VK922 are VdS Approved as indicated in the Approval Chart for installation in accordance with CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems - Design, Installation, and Maintenance where flat spray sprinklers are permitted. Permitted for use only in concealed spaces, above suspended open ceilings, and in racks. Approved for use only in the pendent position. Align the deflector parallel with the ceiling or roof. Sprinkler VK920 (K80) is allowed in OH installations and HHS as an intermediate sprinkler in high piled storage. Sprinkler VK922 (K115) is allowed only in HHS as an intermediate sprinkler in high piled storage. Deflector Position 1. For OH installations: There must be a clear space of at least 12 (300 mm) between the sprinkler deflector and the suspended roof or suspended ceiling. NOTE: This includes suspended open cell ceilings in OH occupancies. The vertical distance between the sprinkler deflector and the top of the suspended ceiling shall be no less than 12 (300 mm). 2. Intermediate sprinklers in HH occupancies: The clearance between the sprinkler deflector and the top of storage shall be not less than 4 (100 mm). NOTE: It shall be ensured that water from sprinklers operating at intermediate levels can penetrate the goods stored. The distance between goods stored in racking and placed back to back shall be at least 6 (150 mm), and if necessary, pallet stops fitted. Beams and similar obstructions: Refer to CEA 4001 or EN12845 and Figure 3 below. For effective installation, CEA 4001 or EN12845 must be referenced and followed in all cases. NOTE: Flat Spray Sprinklers have water distribution characteristics that are significantly different from standard spray sprinklers and conventional sprinklers. This allows Sprinklers VK920 and VK922 to be used in conformance with CEA 4001 or EN12845. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. a = Minimum horizontal distance from beam to sprinkler, m b = Height of deflector above (+) or below (-) beam, m Figure 3: Distance of Sprinkler Deflector from Beams (m)

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_072508 New page 127a-e, issued August 1, 2008.