Simulation of Three-Phase Active Filter for Harmonics Reduction and Reactive Power Compensation

Similar documents
Line Reactors and AC Drives

Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

Product Data Bulletin

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Analysis and Control of Three Phase Multi level Inverters with Sinusoidal PWM Feeding Balanced Loads Using MATLAB

v v v Keywords-- Power Quality, Shunt active filter, Indirect current control, ANN control

New Control Strategy To Improve Power Quality Using A Hybrid Power Filter

Analysis of AC-DC Converter Based on Power Factor and THD

How To Improve Power Quality

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

Principles of Adjustable Frequency Drives

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

MODELING AND SIMULATION OF A THREE-PHASE INVERTER WITH RECTIFIER-TYPE NONLINEAR LOADS

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Closed Loop PWM Control for Induction Motor Drive Using Dual Output Three Phase Inverter

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

High Intensify Interleaved Converter for Renewable Energy Resources

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition

NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: [633] [Choudhary, 3(12): December, 2014] ISSN:

Keywords: Electric circuits, passive circuits, active circuits, voltage source inverter, reactive power theory, active filters.

New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

98% Efficient Single-Stage AC/DC Converter Topologies

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

An Efficient AC/DC Converter with Power Factor Correction

Parametric variation analysis of CUK converter for constant voltage applications

WIND TURBINE TECHNOLOGY

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

FREQUENCY CONTROLLED AC MOTOR DRIVE

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Introduction. Harmonics and IEEE 519 Page 1 of 19

CHAPTER 2B: DIODE AND APPLICATIONS. D.Wilcher

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement

Relationship between large subject matter areas

MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

Lecture - 4 Diode Rectifier Circuits

The full wave rectifier consists of two diodes and a resister as shown in Figure

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

A COMPERATIVE PERFORMANCE ANALYSIS OF BRIDGELESS PFC BOOST CONVERTER WITH THE CONVENTIONAL CONVERTER

Power System Harmonics

EET272 Worksheet Week 9

Application Guide. Power Factor Correction (PFC) Basics

Submarine Cable Power Transmission using DC High-Voltage Three-Level Converters

A bidirectional DC-DC converter for renewable energy systems

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

International Journal of Power Control Signal and Computation (IJPCSC) Vol. 2 No. 2 ISSN : X

See Horenstein 4.3 and 4.4

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Introduction to Power Supplies

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

Enhancement of load balancing for dynamic loads using D-STATCOM

POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

2012 San Francisco Colloquium

Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

Control Development and Modeling for Flexible DC Grids in Modelica

MULTI-LEVEL INVERTER WITH DC LINK SWITCHES FOR RENEWABLE ENERGY SOURCES

ULRASONIC GENERATOR POWER CIRCUITRY. Will it fit on PC board

CYCLOCONVERTERS. Fig.1 Block diagram of a cycloconverter

Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation

Application Note AN- 1095

Bridgeless PFC Implementation Using One Cycle Control Technique

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Performance Enhancement of Wound Rotor Induction Motor by VSI with Dynamic Capacitor Controlled Rotor Circuit

HVDC-VSC: transmission technology of the future

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Analog & Digital Electronics Course No: PH-218

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Variable Voltage Variable Frequency Speed Control of Induction Motor Using FPGA-Xilinx

FOUR LEGGED ACTIVE POWER FILTER COMPENSATION FOR A UTILITY DISTRIBUTION SYSTEM

Power Supplies. 1.0 Power Supply Basics. Module

A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement

The Flyback Converter

International Journal of Advanced Research in Computer Science and Software Engineering

AMZ-FX Guitar effects. (2007) Mosfet Body Diodes. Accessed 22/12/09.

Pulse Width Modulated (PWM) Drives. AC Drives Using PWM Techniques

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

Transcription:

Simulation of Three-Phase Active Filter for Harmonics Reduction and Reactive Power Compensation Rajesh Kr Ahuja 1, Sushil Verma 2, Bhupender Dhull 3 Department of Electrical Engineering, YMCA University of Science & Technology, Faridabad, Haryana,India 1,2,3 ABSTRACT: This paper presents a simulation of a simple control scheme for a three-phase shunt active filter to remove harmonics and reactive power compensation of the non-linear loads. A 3-phase voltage source inverter bridge with a dc bus capacitor is used there as an active filter (AF). A PWM current control is used to generate the gating signals to the AF. Source reference currents are calculated from load currents, dc bus voltage and source voltage. The command currents for AF are calculated using source reference currents and load currents. A three- phase diode rectifier with resistive loading is used as non-linear load. The validity of scheme is shown by simulation results. Keywords: Active Filter (AF), Pulse Width Modulation(PWM), Total Harmonic Distortion(THD) I. INTRODUCTION In recent years both power engineers and consumers have been giving focus on the electrical power quality i.e. degradation of voltage and current due to harmonics, low power factor etc. Nearly two decades ago majority loads used by the consumers are passive and linear in nature, with a few non-linear loads thus having less impact on the power system. Solid state power converters are widely used in applications such as adjustable speed drives (ASD), static power supplies and asynchronous ac-dc links in wind and wave generating systems. These power converters behave as non-linear loads to ac mains and inject harmonics and result in lower power-factor and efficiency of the power system. However, due to technical advancement in semiconductor devices and easy controllability of electrical power, nonlinear loads such as SMPS, rectifier, chopper etc. are more used. The power handling capacity of modern power electronics devices such as power diode, silicon controlled rectifier (SCR), Insulated gate bipolar transistor (IGBT), Metal oxide semiconductor field effect transistor (MOSFET) are very large, so the application of such semiconductor devices is very popular in industry as well as in domestic purpose. Whilst these advantages are certainly good but there lies of such excessive use of power electronic devices a great problem, i.e. generation of current harmonics and reactive power in the power system network. As a result, the voltage at different buses of power system network is getting distorted and the utilities connected to these buses are not operated as designed. The harmonic current pollute the power system causing problems such as transformer overheating, voltage quality degradation, rotary machine vibration, destruction of electric power components and malfunctioning of medical facilities etc. Conventionally, passive filters were the choice for the elimination of harmonics and to improve powerfactor. These passive filters have the disadvantages of large size, resonance, and fixed compensation. In the last couple of decades, the concept of active filters (AF) has been introduced and many publications have appeared on this subject [5-7]. Many control concepts, such as instantaneous power theory [1,2] notch filters [3], and flux based controllers [4] have also been introduced. Most of these control schemes require various transformations and are difficult to implement. This paper presents a simple algorithm to achieve the control for AF. To provide clean power at the consumer-end active filter (AF) is used. Several approaches, such as, hybrid filters and multistep inverters are reported to reduce the size of active filters [8]. In AF, the main objective is to maintain sinusoidal unity power-factor supply currents (by shunt AF) to feed active power to the load and to meet the losses in the AF. These two components of Copyright to IJAREEIE www.ijareeie.com 5199

active power can be computed from load currents, dc bus voltage and supply voltages. From the measured active power required by the system, reference unity power-factor supply currents are derived. By subtracting load currents from these reference supply currents, compensating currents of the AF phases are obtained. The study is based on a 3-wire 3-phase system. The familiar 3-phase uncontrolled rectifier with resistive loading is taken as a non-linear load. The steady state and transient performance of the proposed control scheme is found quite satisfactory to eliminate the harmonics and reactive power components from utility currents. II. SYSTEM CONFIGURATION The basic system blocks of the conventional parallel AF are shown in Fig. 1. The AF is composed of a standard 3- phase voltage source inverter bridge with a dc bus capacitor to provide an effective current control. A PWM current control is used to provide quick response of the AF. The non-linear load is a dc resistive load supplied by 3-phase uncontrolled bridge rectifier with an input impedance and resistor on the output. Because of resistive loading the uncontrolled bridge rectifier draws pulsating non sinusoidal currents from ac source. It also draws reactive power from the mains depending upon the load magnitude and its parameters. The basic function of the proposed control scheme of parallel AF is to compensate harmonics and the reactive power needed for the load so that the ac supply give only the sinusoidal balanced unity power factor currents. The desired AF currents are calculated by sensing the dc bus voltage, load current and source voltage. The PWM current controller generates the switching signals to AF devices to force the desired currents into the AF phases. With this control scheme, the AF meets harmonic and reactive current requirements of the load. The AF connected in parallel with the load, also enhances the system efficiency as the source does not process harmonic and reactive power. The active filter (AF) is a popular approach for cancelling the harmonics in power system. The main component in the AF is the control unit. Fig. 2 shows the proposed control scheme of the shunt AF [5]. The ac source supplies the fundamental active power component of load currents and another fundamental component current is to maintain the voltage across capacitor to a desired value. The later component of source current is to feed the losses in the converter such as switching loss, ohmic loss, capacitor leakage loss, etc. in the steady state and to maintain the stored energy on the dc bus during transient conditions such as sudden fluctuations of load etc. This component of source current (I * smd) is computed using dc bus capacitor value (C dc,), average voltage on dc bus (V dc ) and a chosen reference voltage of the dc bus (V * dc). The fundamental active power component of the load currents (I * smp) is computed using sensed load currents and voltages. The total reference source peak current (I * sm) is computed by taking sum of components (I * smp) and (I * smd). The instantaneous source reference currents (i * sa, i * sb and i * sc) are computed using the peak value (I * sm) of current and unit current templates (u sa, u sb and u sc ) derived from sensed source voltages. The command currents of the AF (i * ca, i * cb and i * cc) are computed by taking the difference between instantaneous source reference currents (i * sa, i * sb and i * sc) and sensed load currents (i La, i Lb and i Lc ). The PWM current controller is used over the reference AF currents (i * ca, i * cb and i * cc) to obtain the gating signals to the devices of the AF. On the basis of proper shaping of compensating currents the value of AF inductance (L c ) is selected. With high value of L c compensating currents do not track reference currents and low values of L c will produce large ripples in compensating currents. The AF meets the requirements of harmonic and reactive components of load currents locally, resulting in sinusoidal unity power factor source currents under fluctuating conditions of load in the system. The system consists of ac source, non-linear load, the AF and the simple control scheme. The components of the system are analysed separately and integrated for development of the complete model for the simulation. Control Scheme The operation of the control scheme has been explained in the previous section. The governing equations for the different blocks are deduced in sequence. Copyright to IJAREEIE www.ijareeie.com 5200

i S i L L S R S R L I R V L V S AC Source R C Non-Linear Load i C L C V S Active Filter C dc V dc Fig. 1 Basic Building Block of Active Filter Peak Source Current Estimation The peak source current (I * sm) has two components estimated as follows. The source active component corresponding to the load (I * smp) is computed from the average load power (P S ). The instantaneous power P L is, (1) Here, i La, i Lb and i Lc are three phase sensed load currents and v sa, v sb and v sc are the sensed three-phase source voltages and under ideal conditions these can be expressed as: (2) In Eq. (2), V sm is the peak of source voltage and is the frequency of the ac mains in rad/sec. (3) The peak fundamental unity power-factor source current component can be estimated using P S and V sm from Eq. (3). The second component of source current (I * smd) is to maintain the average voltage on the dc bus at a constant value, overcoming the switching, ohmic and capacitor losses in the AF. The computation of I * smd is based on the following logic. A reference dc bus average voltage (V * dc ) is assumed. By sampling the actual dc bus voltage the average (V dc,) is Copyright to IJAREEIE www.ijareeie.com 5201

computed over the one sixth period of supply frequency (T x ). The energy difference corresponding to V * dc, and V dc over the Tx, is : [ ] (4) The AF attempts to draw this energy difference from ac mains through unity power-factor current with a peak value of I * smd, over the same interval T x. This energy relationship can be expressed as (5) From Eq. (5),I * smd is obtained. When V* dc Well chosen, under steady state operation V dc will never become equal to V* dc but I * smd will established to a fixed value as demanded by the losses in the AF The total peak source current from equations (3) and (4) is: (6) Source Reference Currents Generation Harmonic free unity power-factor, 3-phase source currents may be estimated using unit current templates in phase with source voltages and the computed peak values. The unit current templates are derived from equation (2) as: (7) The reference 3-phase source currents are estimated as: (8) Reference AF Currents Generation The three-phase AF reference currents are calculated using the reference source currents in Eq. (8) and the sensed load currents as: (9) PWM Current Controller This current controller takes the three phase AF reference currents as input signals and generates gating signals for PWM-VSI of AF. The equation (9) gives these three phase AF reference currents. III. PERFORMANCE OF SYSTEM Performance characteristics of the AF system with proposed control scheme are given in Figs. 2-4 illustrating the steady state and transient behaviour at different loads. Fig. 2 shows the source voltage, three-phase source currents, load current and dc bus voltage when a load of 10 ohm is used across rectifier diode. In steady state condition the simulation time is taken as t=0 to t=0.1 sec with constant load. The load current and source current is shown in Fig. 2.The AF inject the compensating current in system, which results in compensation of source current. The compensating current containing only the harmonic current, which is introduced to the power system due to non-linear load but in opposite phase. It is clear from the Fig. 2 that, the waveform is sinusoidal with some high frequency ripples. The DC voltage across capacitor is also shown in Fig. 2.For transient state, during the period t=0 to t=0.05 sec R s parameter of the nonlinear load is set as 15 Ω. From t=0.05 to 0.1 sec the load parameter is changed to 7.5 Ω. The corresponding load current and source current waveforms obtained are shown in the Fig. 3. Fig. 3 indicates that after 0.05 sec the load current magnitude is changing as the load is changing and settling very quickly. The AF supplies the compensating current for source current compensation. The capacitor voltage during transient period is nearly same as the steady period is shown in Fig. 3. Copyright to IJAREEIE www.ijareeie.com 5202

Fig. 4 shows the THD analysis of load current and source current. Simulations of integrated control circuit of AF are conducted with steady state and transient conditions. The results obtained show that the source current has minimised harmonics with shunt AF. THD analysis shows that PWM current controller has good performance for reduction of harmonics. FFT analysis of the active filter calculated the THD of the load current and source current. Here THD of source current has minimized to 2.81% which is less than 5% Fig.2 Steady State Performances of AF i.e. Source Voltage, Load Current, Source Current and DC Voltage Copyright to IJAREEIE www.ijareeie.com 5203

Fig.3 Transient Performances of AF i.e. Load Current, Source Current and DC Voltage (a) Copyright to IJAREEIE www.ijareeie.com 5204

(b) Fig. 4 THD analysis of (a) Load Current (b) Source Current IV. CONCLUSION In this paper, the performance of the shunt active filter is analysed by simulation in MATLAB/Simulink using a simple technique for minimizing harmonics and compensating reactive power in the power system. The performances of shunt active power filter with PWM Current Controller are verified with the simulation results. From the results; it clearly indicates that, the current ripple is less by using PWM Current Controller. The transient response and steady state performance of this controller has been evaluated. The THD of the source current after compensation is 2.81% with PWM Current Controller which is less than 5 % proving the validity of scheme. REFERENCES [1] Akagi H., Kanazawa Y., and Nabae A., Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components, IEEE Transactions on Industry Applications, Vol. IA-20, No.3, May/June 1984, pp. 625-630. [2] H. Akagi and H. Fujita, "A New Power Line conditioner for Harmonic Compensation in Power Systems", IEEE Trans. on Power Delivery, Vol. 10, No 3, July 1995, pp. 1570-1575. [3] M. Rastogi, N. Mohan and, A.A. Edris, "Hybrid-Active Filtering of Harmonic Currents in Power Systems", IEEE Transactions on Power Delivery, Vol. 10, No. 4, October 1995, pp. 1994-2000. [4] S. Bhattacharya, A. Veltman, D.M. Divan and R.D. Lorenz, "Flux Based Active Filter Controller", IEEEIAS Annual Meeting Record, 1995, pp.2483-2491. [5] Bhim Singh, Kamal Al-Haddad and Ambrish Chandra, a new control approach to three-phase active filter for harmonics and active power compensation", IEEE Transactions on Power Systems, Vol. 13, No. 1, February 1998. [6] Bhim Singh, Kamal Al Haddad and Ambrish Chandra, A Review of Active Filters for Power Quality Improvement, IEEE Trans on Industrial Electronics, Vol.46, No.5, October 1999, pp. 960-970. [7] Mendalek N., Al-Haddad K., Fnaiech F and Dessaint L.A., Nonlinear control technique to enhance dynamic performance of a shunt active power filter IEEE Trans. Power application, vol. 150, (2003):pp. 373 379. [8] H. Akagi, "New Trends in Active Filters for Improving Power Quality" IEEE PEDES Conference Record, January 1996, pp. 417-425. Copyright to IJAREEIE www.ijareeie.com 5205