HomeSpec REPORT SUMMARY



Similar documents
Pre-Drywall Inspection Report

Home Inspection Report

COMPREHENSIVE PROPERTY INSPECTIONS

Structure Survey Findings:

PDmB, Inc. Definitions

Vision Home Inspection

October 5, 2015 Dear Client,

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

HEDDERMAN ENGINEERING, INC. Office , Fax

The Uniform Building Inspection Report Condensed

Mark Cramer Inspection Services, Inc.

PROPERTY INSPECTION REPORT

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Inspection Item COMMENTS

Inspecting to a higher standard.

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

StuccoSpec Moisture Testing Inspection

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Self-Home Inspection Checklist

Residential Inspection Guidelines

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Home Inspection Report

Inspection Tech. (330) Inspected By: Aaron Westerburg

Home Inspection Report

Total Home Inspection Checklist

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

I NI NP R Inspected Items

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public

Inspecton Report. Property Address:

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

INSTALLATION OF A BAY WINDOW

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Georgia Home Inspection Services

South Carolina Home Inspector Standards of Practice

SNS Home Inspections LLC

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Prestige Home Inspection LLC

SWF Home Inspections

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Crawford Inspection Services C.C.B. #

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

March 14, Installation of Bay, Bow and Garden Windows

Home Warranty Inspection Report

PARK COUNTY BUILDING PERMIT GUIDE PO Box 517 Fairplay, CO Fax: Inspections:

2014 British Columbia Building Code Changes

Residential Building Inspection Policies

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008

Holz Choices & Specifications

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

HOME INSPECTION CHECKLIST

Estimated Cost of Repair

December 24, SEDA Construction Attn: Ted Walker 2120 Corporate Square Boulevard Jacksonville, Florida 32216

BUILDING PERMIT SPECIFICATIONS

10 Secrets of Home Inspections Every Home Buyer Should Know

PEPPER VINER HOMES WARRANTY GUIDELINES

RRIO Checklist. Use of checklist: Definitions: Limitations

STANDARD FEATURES & PROCESS- NEW HOME CONSTRUCTION. Now offered for a limited period of time, free solar with each home!

Four Point Inspection

Estimating Database Checklist

Propery Inspection Report

INSPECTION REPORT. Client Name Address From the inspection on: August XX, CHRIS LOWE

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Foundation. Foundation

Orlando Home Inspection Services

7894 Anystreet Avenue Beverly Hills, CA 90210

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Building Condition Assessment Report

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

PRE-PURCHASE INSPECTION REPORT

Home Inspection Report

TechPractices: Home Front Homes:

159 Morningside Avenue, Toronto

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

RODENT PROOFING CHECKLIST

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Georgia Association of Home Inspectors

Common Problems with Walls

The UPLANDS at ORO VALLEY Sterling Features

New Home Walk-Through Package

Final agency action regarding decision below: ALJFIN ALJ Decision final by statute IN THE OFFICE OF ADMINISTRATIVE HEARINGS

At Home Inspections Inc. Home Inspection Report

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

2. What building projects are exempted? (permit not required)

Transcription:

HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above referenced property was conducted on 04/25/2007. This inspection report reflects the visual conditions of the house at the time of the inspection only. Hidden or concealed defects cannot be included in this report. No warranty is either expressed or implied. This report is not an insurance policy, nor a warranty service. An earnest effort was made on your behalf to discover all visible defects, however, in the event of an oversight, maximum liability must be limited to the fee paid. The following is an opinion report, expressed as a result of the inspection. Please take time to review limitations contained in the inspection agreement. REPORT SUMMARY Please note that the following comments are arranged not in order of importance, but rather in the order in which they appear in the inspector's report. SECTION A: The following items are building deficiencies or safety concerns that require further evaluation and or repair by the new home builder. We always recommend using licensed contractors. PRE DRYWALL INSPECTION CONCRETE SLAB/FOUNDATION: 1. a) Concrete foundation/floor extends past master bathroom sliding glass door. It appears that stucco will be installed against floor with no overhang for weep screed drainage of water. b) Exposed metal tie downs observed. c) Chips in concrete stem wall observed at various locations. Recommend repair/correction of above noted conditions by the new home builder. WALL FRAMING: LUMBER QUALITY: 2. Damaged stud observed at west exterior wall of garage due to Anchor Bolt location. Recommend repair by new home builder. HomeSpec Inspection Services, LLC 5717 E. Thomas Rd., #6, Scottsdale, AZ 85251 480-970-5446 Summary Page 1

HomeSpec BOTTOM PLATES: 3. a) Anchor Bolt nut is not tight to bottom plates at: - West wall of garage - Left side of master bedroom bay window. b) Anchor Bolt washers stick out past edge of walls at: - East wall of garage by entry to the house. - East wall of den. Recommend repair of the above noted conditions by the new home builder. TOP PLATES: 4. Additional Fire blocking needed at vent through top plate at Laundry Room. Recommend builder install additional fire blocking. WEEP SCREED: 5. Weep Screed is not tight to foundation wall at several locations throughout house. Recommend builder reviewing /repairing all areas of weep screed installation that are not tight to foundation to prevent moisture and pest intrusion. EXTERIOR WALLS: 6. Weep screeds and penetrations through out exterior wall areas were not all sealed and caulked due to all foam/wire installation not being completed at time of this pre dry wall inspection. Recommend all weep screeds and penetrations be sealed prior to dry wall and or stucco installation. DOOR INSTALLATION: 7. Appears that garage service door was installed after wall and floor had already been built. Currently repairing/retrofitting this area at time of this inspection for new door. Recommend reviewing area with the builder after installation of door has been completed. Note: Roof comments regarding valley design at roof area above this door, rain water draining over door because of door location and roof design. WINDOW 8. Broken dual pane window observed at east wall of master bathroom. Recommend builder replace damaged window glass. Safety concern. ROOF FRAMING: ROOF UNDERLAYMENT: 9. Roofing Felt material does not properly extend 1" past edge of roof at gable roof ends at several locations. Recommend builder correct felt installation to insure proper installation of 1 inch past edge of roof at all roof areas prior to tile installation. ADDITIONAL ROOF COMMENTS: 10. Valley of roof drains over the Garage Service Door. Appears to be poor design. Note: See comment regarding addition of garage service door to this area Review with builder if corrections can be made to prevent rain water draining over door area. HomeSpec Inspection Services, LLC 5717 E. Thomas Rd., #6, Scottsdale, AZ 85251 480-970-5446 Summary Page 2

HomeSpec PLUMBING: 11. Hole observed in cold water Pex type plastic plumbing at Master bathroom west sink. Fasteners from exterior siding installation penetrated line to cause hole in pex plastic plumbing. Note: Inspector notified job superintendent prior to leaving property by phone Recommend builder replace damaged plastic water line at Master bathroom west sink area prior to dry wall installation. WASTE LINES: 12. Waste Line Vent pipe sticks out past wall at west side of exterior wall. Recommend builder repair. ADDITIONAL COMMENTS: 13. Inspector could not identify purpose of capped off pipe through floor (not in Wall) of kitchen to left side of range area. Recommend reviewing with builder purpose of this capped pipe. Repair/Remove if required. SECTION B: The following items are building deficiencies that should be repaired but do not effect the safety or habitability of the house. Not applicable to this inspection. SECTION C: The following are either notes for your general information or items that should be reviewed at the final inspection prior to close. PRE DRYWALL INSPECTION LOT GRADE: 1. Grading was not completed at time of inspection. Review again at final inspection prior to close. SIDEWALKS AND DRIVEWAY: 2. Not installed at time of this inspection. Recommend reviewing at final inspection prior to close. HomeSpec Inspection Services, LLC 5717 E. Thomas Rd., #6, Scottsdale, AZ 85251 480-970-5446 Summary Page 3

HomeSpec We request that in addition to reviewing this report summary of your home inspection, that you also read the inspection report in its entirety since it contains the complete review of the house along with any pictures taken. The sole purpose of this report summary is to help you easily identify areas that need further review or recommended repair. If you have any questions regarding the inspection report please contact us at 480-970-5446, or our toll free number 888-677-3287, or by e-mail: homespecaz@qwest.net Thank you for selecting HomeSpec Inspection Services to do your pre-purchase home inspection. Again, if you have any questions regarding the inspection report or the home, please feel free to call us. Sincerely, HomeSpec Inspection Services Inspector Name & AZ Certification Number: Kevin Shroyer 42275 480-970-5446/Toll Free Phone: 888-677-3287 Attachments - Complete Inspection Report HomeSpec Inspection Services, LLC 5717 E. Thomas Rd., #6, Scottsdale, AZ 85251 480-970-5446 Summary Page 4

Report Date - 04/25/2007 For: Rachel Trujeque 13038 W. Plum Road Lot #1225, Peoria Report Table of Contents REPORT SUMMARY SEC 1 INSPECTION CONDITIONS 1 PRE DRYWALL INSPECTION 3 INSPECTION SERVICES AGREEMENT & Appendix A ARIZONA STANDARDS OF PROFESSIONAL PRACTICE SECTION/COLOR LEGEND: Section A (Red report items): Denote conditions that are either safety related and/or need professional evaluation and repair by a licensed trade professional. Section B (Green report items): Denote conditions that are primarily maintenance-type repairs and/ or monitoring issues that do NOT require professional repair or evaluation, and do NOT affect safety. Section C (Blue report items): Denote conditions that we suggest further review with the seller and/or areas of the home we were not able to access at time of inspection. 2006 HomeSpec 480-970-5446 Page 1 of 1

INSPECTION CONDITIONS CLIENT & SITE INFORMATION: FILE #: 4888. DATE OF INSPECTION: 04/25/2007. TIME OF INSPECTION: 9:00 a.m. CLIENT NAME: Rachel Trujeque. INSPECTION LOCATION: 13038 W. Plum Road Lot #1225. CITY/STATE/ZIP: Peoria, AZ 85383. INSPECTOR Inspector Name & AZ Certification Number: Kevin Shroyer 42275. INSPECTION REPORT TYPIST: Gwen Shirvanian. Front exterior at time of inspection CLIMATIC WEATHER: SOIL APPROXIMATE OUTSIDE TEMPERATURE: Clear. Dry. 75 DegF. BUILDING CHARACTERISTICS: MAIN ENTRY FACES: South. CONSTRUCTION TYPE: 1 family. STORIES: 1. SPACE BELOW GRADE: Ground floor living area. OTHER INFORMATION: AREA: CLIENT PRESENT: PEOPLE PRESENT: Suburb. No. Buyer's agent. 2007 HomeSpec 480-970-5446 Page 1 of 9

PAYMENT INFORMATION: Service Agreement Sent Inspection Agreement to client via e-mail for review prior to inspection. TOTAL FEE: $325. PAID BY: Credit Card, Visa. 2007 HomeSpec 480-970-5446 Page 2 of 9

PRE DRYWALL INSPECTION Footings and stems are not part of this inspection. Drains and water pipes below grade are not part of this inspection. LOT GRADE: Type: Flat site. Grading was not completed at time of inspection. Review again at final inspection prior to close. CONCRETE SLAB/FOUNDATION: Type: Poured Slab. In generally good condition with the following noted exceptions: a) Concrete foundation/floor extends past master bathroom sliding glass door. It appears that stucco will be installed against floor with no overhang for weep screed drainage of water. Foundation extends/exposed tie down b) Exposed metal tie downs observed. c) Chips in concrete stem wall observed at various locations. Recommend repair/correction of above noted conditions by the new home builder. SIDEWALKS AND DRIVEWAY: Not installed at time of this inspection. Recommend reviewing at final inspection prior to close. 2007 HomeSpec 480-970-5446 Page 3 of 9

WALL FRAMING: LUMBER QUALITY: Damaged Stud at west garage wall Lumber quality observed in good condition with the following exception: Damaged stud observed at west exterior wall of garage due to Anchor Bolt location. Recommend repair by new home builder. Window frames observed to be in good condition. 2007 HomeSpec 480-970-5446 Page 4 of 9

BOTTOM PLATES: All bottom plates observed in good condition, properly installed with the following noted exceptions: a) Anchor Bolt nut is not tight to bottom plates at: - West wall of garage - Left side of master bedroom bay window. b) Anchor Bolt washers stick out past edge of walls at: - East wall of garage by entry to the house. - East wall of den. Recommend repair of the above noted conditions by the new home builder. Top: Anchor Bolts/Bot: Anchor Washers TOP PLATES: All top plates observed in good condition with the following noted exception: Additional Fire blocking needed at vent through top plate at Laundry Room. Recommend builder install additional fire blocking. Fire blocking needed 2007 HomeSpec 480-970-5446 Page 5 of 9

WEEP SCREED: EXTERIOR WALLS: Weep Screed is not tight to foundation wall at several locations throughout house. Recommend builder reviewing /repairing all areas of weep screed installation that are not tight to foundation to prevent moisture and pest intrusion. Foam wire for stucco being installed at time of this inspection. Weep screeds and penetrations through exterior walls were not all sealed and caulked due to all foam/wire installation not being complete at time of this pre dry wall inspection. Recommend all weep screeds and penetrations be sealed prior to dry wall and or stucco installation. Weep screed not tight Foam and Wire for stucco being installed 2007 HomeSpec 480-970-5446 Page 6 of 9

DOOR INSTALLATION: WINDOW Appears that garage service door was installed after wall and floor had already been built. Currently repairing/retrofitting this area at time of this inspection for new door. Recommend reviewing area with the builder after installation of door has been completed. Note: Roof comments regarding valley design at roof area above this door, rain water draining over door because of door design and location. At time of this inspection all installed windows observed in good condition with the following noted exception. Broken dual pane window observed at east wall of master bathroom. Recommend builder replace damaged window glass. Safety concern. Garage service door added Broken master bath window MECHANICAL SYSTEMS: HVAC DUCT WORK GAS ELECTRICAL SYSTEMS ROUGH WIRING AND JUNCTION BOXES: Flex pipe duct work for HVAC system all observed to be properly installed, secured and supported. No restricted ducts observed. Gas pipes observed installed. All appeared to be properly installed, secured and supported. All rough wiring and junction boxes observed to properly installed and secured. Note: Inspector unable to verify that any seller's optional electrical was installed. Review of builder plans is outside scope of this of inspection. ROOF FRAMING: TYPE OF FRAME: SERVICE PLATFORM FOR ATTIC: ROOF SHEATHING: TYPE OF ROOF: Truss framing installed. All trusses at time of this inspection observed to be in good condition and properly installed. Note: Review final condition of trusses after all equipment is installed at final inspection. Observed that service platform in attic is in good condition, adequate size and properly installed. Roof sheathing observed to be in good condition and properly installed. Tile roofing not installed at time of this inspection. Metal Flashings observed to properly installed and in good condition. 2007 HomeSpec 480-970-5446 Page 7 of 9

ROOF UNDERLAYMENT: Roofing Felt material does not properly extend 1" past edge of roof at gable roof ends at several locations. Recommend builder correct felt installation to insure proper installation of 1 inch past edge of roof at all roof areas prior to tile installation. ROOF VENTS: ADDITIONAL ROOF COMMENTS: Improper felt installation Flat Roof Vents; Gable Vents and Roof Vents observed in good condition. Properly installed Screens observed in good condition. Valley of roof drains over the Garage Service Door. Appears to be poor design. Note: See comment regarding addition of garage service door to this area Review with builder if corrections can be made to prevent rain waterfrom draining over door area. Roof valley drain PLUMBING: TYPE: Copper type plumbing observed at the main entry. Pex type plastic plumbing through out the house. Exterior fasteners penetrated water line Hole observed in cold water Pex type plastic plumbing at Master bathroom west sink. Fasteners from exterior siding installation penetrated line to cause hole in pex plastic plumbing. Note: Inspector notified job superintendent prior to leaving property by phone Recommend builder replace damaged plastic water line at Master bathroom west sink prior to dry wall installation. 2007 HomeSpec 480-970-5446 Page 8 of 9

WATER SOFTENER: WASTE LINES: Water softener loop observed to be properly installed. Plastic type observed in good condition and properly installed with the following noted exception: Waste Line Vent pipe sticks out past wall at west side of exterior wall. Recommend builder repair. MAJOR SYSTEMS: HEATING AND AIR CONDITIONING TYPE: DUCTWORK: Main House is setup for Gas Heating Guest Suite is setup for Electric Heating All cooling is Electric HVAC systems not installed at time of this inspection. Flex type duct work observed to be in good condition, properly installed and supported. OTHER SYSTEMS: FIRE SPRINKLER SYSTEM Fire Sprinkler system installed. All plumbing observed in good condition, properly installed and supported. ADDITIONAL COMMENTS: Capped pipe in kitchen-? Inspector could not identify purpose of capped off pipe through floor (not in Wall) of kitchen to left side of range area. Recommend reviewing with builder purpose of this capped pipe. Repair/ Remove if required. 2007 HomeSpec 480-970-5446 Page 9 of 9