M-Bus AMR Interface E350 User Manual

Similar documents
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Polyphase kwh Electricity Meter

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Digital input modules

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

PCS0100en Persy Control Services B.V. Netherlands

Cable Plug acc. to DIN EN , Form A

Application/Connection Examples

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Install the DeviceNet Module using the following procedure:

Modular I/O System Analog and Digital Interface Modules

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines

NC-12 Modbus Application

Quick Connect. quick - simple - efficient.

IO-DIM6 6-Channel, Digital to Analogue Converters

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Duct Humidity Transmitter

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

3-phase, bidirectional energy meter

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

M-Bus-Logger Data Logger

HYDRUS ULTRASONIC METER

ADM1TE 5/30A DIN rail single phase two wire energy meter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

IO-RM3 3-Stage Relay Module

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

On the M-BUS Interface you can add up to 60 M-BUS Devices (60 unit loads).

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Installation manual. Generator Paralleling Controller GPC multi-line C

OZW30. Central Unit SYNERGYR

DMX2PWM 9 Channel Dimmer Setup Manual

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

P1 Companion Standard

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

TX2123 RS485 TO ETHERNET ADAPTOR

The multi-functional integrator Supercal 531

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Repeaters and Mimics Data Sheet

Energy Management Energy Meter Type EM23 DIN

Rack mounted telephone- and leased line modem for industrial applications

A project to optimise quality and energy efficiency must include metering

SVR 12/24V and SVR Akku 12V Installation instructions

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PD 100A. Printing data system

BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI

HWg-STE HWg-STE PoE MANUAL

I STAR COMPUTER CO., LTD

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Safety Relays ESM/ESM-F

Telephone- and leased line modem for industrial applications TD-36

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

WD-AMX Water Detection Controllers

HMI display Installation Guide

Model SRMD Setra Remote Monitoring Display

IntesisBox ASCII Server - LON

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

5235 Single Phase Credit Meter

Inductive Proximity Sensors

Operating Instructions

Charge Controller CC611/CC612 Preliminary datasheet

MOUNTING AND OPERATING INSTRUCTIONS

SYSTEM DESCRIPTION Termination Boards

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

SYSTEM 45. C R H Electronics Design

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Part Number Description Packages available

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Installation guide H A. HSI hardwired system interface

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

VOIP-500 Series Phone Quick Installation Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Transcription:

Page 1 from 6 General Upgradable for future communication needs: flexible remote communication modules without breaking approval seal. The new series of modules for domestic use puts promises into practice, paving the way not only for multi-energy applications but also for new services in personal energy management. This specification details the operation and the electrical requirements for connection of an AMR module with M-Bus interface to the L+G E350 (ZxF series 100) meter. Compatible meters ZCF110/120 single phase meter ZMF110/120 multiphase meter ZFF110/120 multiphase meter Functions The AMR interface contains the following functions: Bi-directional communications: an integrated M-Bus (2 wires, passive) interface provides a simple means of connecting multi-energy meters. This makes multi-energy applications an affordable proposition for domestic use. Transmission protocol: IEC 62056-21 Rate input for tariff switching via external control inputs Pulse output (with pulse rate change) Internal communication interface for the transfer billing data between the meter and AMR module (every 10 seconds). For details of the communications protocol, refer to the software interface specification (IEC 62056-21 and OBIS Codes). Phase connections to one phase (230VAC) Safety Notes The owner of the AMR modules is responsible that all persons engaged on work with the modules: Are competent and qualified in accordance with national regulations (see ISSA "Guideline for Assessing the Competence of Electrically Skilled Persons"). Have read and understood the relevant sections of the user manual. Strictly observe the safety regulations (according to the following section) and the instructions in the individual chapters. The owner of the modules is also responsible for: The protection of persons. The prevention of material damage. The training of personnel. The following safety regulations must be observed at all times: Devices which have fallen down should not be installed, even if no damage is apparent, and should be returned for testing to an authorised service centre (internal damage possible). Modules must never be cleaned with running water or high pressure devices. Water can cause short-circuits or damage el. components.

Page 2 from 6 Installation Hints The installation must be done in a way, that even in the case of cable break no dangerous voltages are applied to touchable parts of the module. Generally, meters are delivered with the communication modules installed. The fitting of a meter with a communication module is, therefore, an exception and can be necessary e.g. when a module needs to be replaced. Fit the AMR module in the meter as follows: Strictly observe the safety regulations! Remove the utility seals on the terminal cover and the AMR module cover. Remove the terminal cover (1). Remove the AMR module (2). Insert the AMR module carefully at the place provided in the meter. Ensure the connector pins are not bent when the module is pushed down. Tighten and seal the 2 screws of the AMR module. The connections are marked on the faceplate.

Page 3 from 6 Rate Input The module provides a single optically isolated rate input. Maximum voltage: 230VAC (-20% / +15%) / 2mA Function: no voltage on the rate input: T1 (register 1.8.1 active), default with voltage on the rate input: T2 (register 1.8.2 active) Pulse Output The pulse output circuit appears as an open-collector from an opto-isolator. Maximum voltage: 265VAC/DC Maximum reading rate: 1ms Communication Parameter Some jumper blocks are used for setting the communication parameter. Note: set the jumper before switch-on. Config A LED Config B Jumper Block Config A Jumper block Config A (left site) is used for setting the baud rate and the data format for the M-Bus interface: Default (without jumpers): 9600 baud, 7E1 Set the jumper for activation: Jumper Config A 1 2 3 4 Function 8N1 8E1 4800 baud 2400 baud Example for 2400 baud, 8N1: set the jumpers 1 and 4 Jumper Block Config B Jumper 1 is used for setting the timeout for acknowledge (according to specification for IEC 62056-21): Without jumper: 2 seconds With jumper: 15 seconds (for readout via GPRS)

Page 4 from 6 Jumper 3 and/or 4 is used for setting the pulse rate for the pulse output: 1/1: without jumpers: without pulse rate change (see meter setup) minimum pulse length: 2ms 1/10: pulse rate 1/10; pulse length 20ms 1/20: pulse rate 1/10; pulse length 40ms 1/40: pulse rate 1/10; pulse length 80ms LED Displays Two LED s display the current operating status of the module and give information about the data transfer. Power: on: AMR module is supplied with power flashed: communication via M-Bus interface Error: on: communication error between AMR module and meter off: no errors Communication The AMR port is conforming to IEC 62056-21 with fixed baud rate. For reading data the meter-id (device address) can be used (e.g. /?<meter-id>!); Explanations of massage contents (see IEC 62056-21): Start character: / (forward oblique, code 2F Hex ) End character:! (exclamation mark, code 21 Hex ) Completion character: CR (carriage return, code 0D Hex ) and LF (line feed, Code 0A Hex ); enter key Length of telegrams (data readout): 745 bytes max. Example for communication path: Sign-on sequence: /!? CR LF without meter-id or /?12345678! CR LF if the meter-id := 12345678 Answer: /LGZz Ident CR LF z := baud rate identification Sign-on acknowledgement: ACK 0z0 CR LF Data readout (billing list): F.F(00) C.1.0(12345678) 0.0(12345678 ) C.1.1(94858005) 1.8.0(0000750.3*kWh) 1.8.1(0000000.0*kWh) 1.8.2(0000750.3*kWh) 2.8.0(0000002.8*kWh) 32.7(233*V) 52.7(233*V) 72.7(233*V) C.5.0(3A)!

Page 5 from 6 Technical data: Housing: Degree of protection: IP52 (according to IEC 60529) Protection class: 2 Polycarbonate housing with terminals for using with Landis+Gyr E350 meters (L+G ZxF domestic meters) Dimensions: 165mm x 90mm x 33mm (W x H x D) Nominal voltage: Power consumption: ca. 2,8W Temperature range: 230VAC (-20% / +15%) / 50Hz connection spring for one phase: Live (L1) and Neutral (N) from meter -45 C to +65 C (operational) -45 C to +90 C (storage temperature) LED displays: 2 LED s: green: Power red: Error Interface: Baud rate: Data format: Transmission protocol: Buffer size: M-Bus (2 wires, passive) according to EN 13757-2 (physical layer) 2400, 4800 or 9600 baud; default: 9600 baud (fixed baud rate) 7E1, 8N1, 8E1; default: 7E1 IEC 62056-21 (conform to VDEW2+) with fixed baud rate (OBIS Codes) 745 bytes Rate input: Max. voltage: 230VAC (-20% / +15%) max. current: 2mA Pulse output: Dimensions Wipe, according to DIN 42864 (S0 output) max. voltage: 265VAC/DC max. current: 50mA min. voltage: 5VDC

Page 6 from 6 Terminal assignment Power connection via connection spring: Connector L1 N Description Phase (Live) 230VAC (-20% / +15%) / 50Hz Neutral Terminal block: Terminal Description (according to VDEW) 13 Rate input (TE1/2) 15 Rate input (G1) 40 Pulse output (G3) 41 Pulse output (AA/+AA) a M-Bus b M-Bus Baer Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com Subject to change without notice! Version 1.13