Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Similar documents
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

The power distribution board that sets new standards

Unified requirements for systems with voltages above 1 kv up to 15 kv

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

The Intelligent AX1 Switchgear for Medium Voltage

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Low Voltage Switchboards The Best Technical Solution for Your Ship

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

SIVACON The Versatile Low-Voltage Switchboard

MNS is Switchgear System Technical Overview

SURGE PROTECTIVE DEVICES

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

CAS 36 Ring Main Unit

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

SIVACON Low Voltage Switchboard

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

R.C.C.B. s two-pole LEXIC

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

Vario-Series Accessories

Series 8146/5-V37 and Series 8150/5-V37

Switchboard system. NorLine 800

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

HERZ-Thermal Actuators

Secondary Unit Substations

TriLine ASSEMBLY System PowerModules

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

The following components are common to most cubicles; this example is an ABB HK cubicle.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contact expansion modules

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Contact expander modules

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

UFES Active protection for switchgear

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Automation Products. Low Voltage Switchgear MNS System Overview

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Protection from Short-circuit

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Safe and secure distribution of medium voltage with AX1

Manual Motor Starter MS 116 up to 16 A Technical Data

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

SENTRON Switching and Protection Devices Air Circuit Breakers

-Liquid-cooled frequency converter switchgear

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

GE Power Controls. MiniFORM Switchboards

Sample - No Commercial Use

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Distribution Boards & Consumer Units

How To Build A Low Voltage Capacitor Lvcp

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Advantages of Fixed Circuit Breaker Switchgear

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Electronic overload relay EF19 and EF45

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Securing your electrical installations Prisma,

High-speed folding doors. F Series

P System Cubicles. Certified for more safety

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

E-STOP relays, safety gate monitors

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Relay mounting systems

FAQs-Main switchboard design criteria

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

The Low-Voltage Switchboard that Sets New Standards

Workspace and storage furnishings

The standards mentioned in this document

DS1 Diode-based transient-free capacitor switch

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Modular Systems wind portfolio overview Power Collection and Grid Connection products

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Medium Voltage Switchgear

Transcription:

Medium voltage switchgear type W rated voltage kv rated current 0 A

General The metal-encapsulated, air-insulated medium voltage switchgears, type W are for universal application. They range from compact ring cable switchgears up to complex power distribution switchgears. Tailored to meet the needs of public utility networks and power supply companies in industry and municipal buildings. These medium-voltage switchgears meet the user s specific requirements in full and ensure a satisfactory power distribution. The W standard types are available in three different dimensional sizes: W 0; w x d x h: 00 x 0 x 00 mm, W ; w x d x h: 0 x 0 x 00 mm, W 0; w x d x h: 00 x 0 x 00 mm. They are available as individual s or as a combined switchgear, where the equipment, sequence etc. can be determined by the customer. The switch s are type-tested in compliance with EN -00. Operating conditions The switch s of type W are installed in closed electrical operating areas which are only to be entered by skilled personnel and appropriately instructed persons. The equipment can be used at an altitude of up to 000 m above sea level. For installations above an altitude of 000 m the rated insulating level of the switchgear must be corrected accordingly. The switch s are designed for use under normal operating conditions in compliance with the standard EN -. Technical standards The design of the air-insulated switch s corresponds to the specifications of the EN - 00. The resistance to accidental arcs of the switch s has been determined at ka and 0 ka; s, by and independent testing institute. The installed switchgear equipment is designed in compliance with EN -. Technical data rated voltage rated frequency rated lightning impulse withstand voltage rated short-time withstand voltage rated short-circuit duration rated current s with circuit breaker V-0- KUF rated current s with load disconnector H rated short-time current s with circuit breaker V-0- KUF rated short-time current s with load disconnector H rated peak current s with circuit breaker V-0- KUF rated peak current s with load disconnector H degree of protection kv 0 Hz kv kv s 0 A 0 A ka 0 ka ka 0 ka IP X Description of the W switch s Design The air-insulated medium-voltage switch s of type W with a width of 00 mm, 0 mm and 00 mm are metal-encapsulated. The switch frame is made of a screwed, hot-galvanized composite structure. The front of the switch s has a single-wing door of steel sheet with door hinge optionally on the right or left. A window of compound glass is inserted in the door. The cover in front of the bus bar compartment is either screwed on or designed as a door for the relay box positioned behind it. Each switch has a screwed on rear of galvanized sheet metal. Connecting cables are conducted into the switch s from below and are mounted on cross rails. The doors and covers of the switchgear are painted in structural paint (available in different colours according to the customer s request).

Equipment The switch s of type W are available in the following versions: Cable switch WK Transformer feeder WT Measuring switch WM Bus sectionaliser WÜ Circuit-breaker WL All switch s are partitioned off from to, in the bus bar area, by means of fibrousglass reinforced plastic plates with lead-in openings. Pressure relief can be in upward or downward direction. Switch s equipped with load-break switches can optionally be fitted with an earthing switch as well. Integrated in the circuit-breaker, type WL, there is also a bus disconnector. It is also possible to equip these s with a set of current transformers and voltage transformers as well as with an earthing switch. The optional interlocking of the equipment practically rules out any form of incorrect operation. All built-in switchgear equipment can be operated manually or via motor-operated mechanisms when the door is closed. The product program is completed by special measuring s which are fitted with current and voltage transformers. Earthing switches or spherical fixed points are available for earthing and shortcircuiting. An insulating protective plate can be inserted when the door is closed. It is possible to install appropriate surge voltage protectors in the, if required. W switch s optional - not possible * not possible with current or voltage transformer WK WT WM WÜ WL WÜL Switch s W 0 Cable Transformer feeder Measuring Bus section. Circuit breaker Circ. br. bus sect. Disconnector * * - - Load disconnector / H H EA / EK H SEA - circuit breaker EK / EA / SEA V.. KUF V.. KUF Earthing switch - Current transformer - Voltage transformer - - - WK WT WM WÜ WL WÜL Switch s W, W 0 Cable Transformer feeder Measuring Bus section. Circuit breaker Circ. br. bus sect. Disconnector - - - - Load disconnector / H H EA / EK H SEA - circuit breaker EK / EA / SEA V.. KUF V.. KUF Earthing switch - - Current transformer - Voltage transformer - - Weights Panel type Description Weight [kg] W - 0 W - W - 0 WK cable switch 0 WT transformer feeder 0 0 WÜ bus sectionaliser 00 0 WM measuring switch 0 0 WL circuit-breaker 0 0 Auxiliary equipment insulating protective plate illumination, floor coverings capacitive voltage testing system in compliance with DIN VDE 0 part, short-circuit indicators additional locking systems with profile cylinder and lockable operating mechanisms

Type W 0 switch s Positions: Pressure relief plate Relay box Bus terminal Switch-disconnector H Withdraw able plate Current transformer Voltage transformer Circuit breaker Position indicator and actuation of load-break switch 0 Position indicator and actuation of disconnecting switch Position indicator and actuation of earthing switch Earthing switch Disconnecting switch HV-HBC fuse Cable terminal Type W 0 switch front view Cable with H EA/EK load discon. also possible with current and voltage transf. 0 0 Cable with H EA/EK load disconnector and disconnector Transformer feeder with H SEA load disconnector, also possible with current and voltage Transformer feeder with H SEA load disconnector and disconnector

Bus sectionaliser with H EA / EK load disconnector Bus sectionaliser with H SEA load disconnector Measuring with current and voltage transformers 0 Measuring in longitudinal rails with current and voltage transformers side and front view Circuit-breaker with circuit breaker and disconnector

Type W and W 0 switch s Type W and W 0 switch front view Cable (bus sectionaliser ) with H EK / EA load disconnector Cable with H EK / EA load disconnector, current and voltage Measuring with current and voltage Measuring in longitudinal rails with current and voltage Transformer feeder (bus sectionaliser ) with H SEA load disconnector

0 0 0 Circuit-breaker (V-0- KUF) with current transformer Circuit-breaker (V-0- F) with current and voltage Circuit-breaker (V-0- KUF) (bus sectionaliser ), also possible with current Specifications are subject to change without notice. DRIBO 0/0