Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

Similar documents
Pressure switches for gas and air Pressure sensors

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Pressure Switch for gas and air

3/2-way Solenoid Valve, direct-acting, NC or NO

Electric Rotary Actuator - On/Off or programmable control actuator

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Control- and feedback head for integrated mounting on Robolux valves Type 2036

How To Use A Flowmeter

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

2/2 and 3/2 Way Size 6 Seat Valves

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Solenoid Valve Island Type 3965

Cable Plug acc. to DIN EN , Form A

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

HERZ-Thermal Actuators

3/2- and 2/2-way cartridge valve type BVE

Hydraulic Control Solutions

Pressure transmitter For general industrial applications Model A-10

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

How To Use A Corona Mdi 110

Digital inductive conductivity transmitter

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Plastic tube flowmeters Series PT/PS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

T U R B I N E G A S M E T E R

Fluxi 2000/TZ Turbine Gas Meter

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Type 3353 Angle Seat Valve

Solenoid valves Type EVU

Solenoid valves 2/2-way direct-operated Type EV210A

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

3/2-way pneumatic cartridge solenoid valve

4/2-Way Pneumatic Solenoid Valve

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

4 Posiflow Proportional Solenoid Valves

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Proportional pressure regulators VPPE

G1/4 Q8. Standard with biased position

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Liquid Level Limit Switch liquiphant T FTL 20

System 8. ü ( System 8

Compact pressure switch Flameproof enclosure Ex d Model PCA

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Combi switchbox with integrated 3/2 way pilot valve

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

2.12. page Products for Explosion hazardous Environment

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

3/2-way Mini Solenoid Valve

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

Electro-pneumatic control valves

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Vacuum drying oven for non-flammable solvents

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

type V46, solenoid or pneumatic operated

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Solenoid Valve Type 3962

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Pressure regulating valve with modulating kit, type DRV

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Overview of types. Technical data

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Heating, air-conditioning, cooling

Technical Data. Dimensions

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Typical Aluminum GFM Mass Flow Meter

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Conductive Level Switch FK 2 Technical Data:

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

J TB/TW Temperature limiter, temperature monitor

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Duct Humidity Transmitter

Actuator for modulating control AME 435

On-off valves MS-EM/EE, MS series, NPT

Series description: Wilo-Drain TC 40

SITRANS F flowmeters SITRANS F M

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HEAVY DUTY STORAGE GAS

Safety detection solutions

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

Transcription:

Double solenoid valve Rp 3/8 - nominal diameters DMV-D/11 DMV-DLE/11 7.30 Printed in Germany Rösler Druck Edition 02.06 Nr. 218 375 1 6 Technical description The DUNGS double solenoid valve DMV integrates two solenoid valves in one compact fitting. - Automatic shut-off valves as per DIN EN 161 Class A Group 2 - Two A valves in one housing - Double seat valves - High flow rates - Max. operating pressure up to bar - Fast closing - Fast opening (DMV-D/11) or slow opening (DMV-DLE/11) with adjustable fast stroke for start gas volume - Adjustable main volume - DC solenoid - Mountable closed position signal contact - Threaded flange - Compact, light-weight Application Double solenoid valves are used where two single valve were mounted previously. In connection with DUNGS gas regulators and additional components, a wide variety of regulating tasks can be performed. It does not contain any non-ferrous metals, suitable for gases of up to max. 0.1 vol.% H 2 S, dry. Suitable for gases of families 1, 2, 3 and other neutral gaseous media. Approvals EC type test approval as per EC Gas Appliance Directive: DMV-...503-525/11 CE-0085 AN 2801 EC type test approval as per EC Pressure Equipment Directive: DMV-...503-525/11 CE0036 Approvals for the North American market: U L, FM and CSA as well as approvals in other important gas consuming countries.

DMV-D/11 Two single-stage solenoid valves normally closed, fast opening, fast closing. Manual limitation of flowing gas volume by main volume setting (D) at valve 1 (V1). Main volume setting (D) of DMV-D 503/11 at valve 2 (V2). DMV-DLE/11 Two single-stage solenoid valves normally closed, slow opening (L), fast closing. Opening time setting (E) with fast stroke section at valve 2 (V2). Manual limitation of flowing gas volume by main volume setting (D) at valve 1 (V1). Main volume setting (D) of DMV-D 503/11 at valve 2 (V2). Specifications Nominal diameters Flange with pipe thread as per ISO 7-1 Max. operating pressure Solenoid valve V1 Solenoid valve V2 Closing time Opening time Fast stroke Main volume restrictor DMV 503 DMV 507 DMV 512, 520 DMV 525 Rp 3/8,Rp 1/2 Rp 1/2,Rp 3/4,Rp 1 Rp 1,Rp 1 1/4,Rp 1 1/2, and their combinations 500 mbar (50 kpa) Automatic shut-off valve as per EN 161: Class A, Group 2 Automatic shut-off valve as per EN 161: Class A, Group 2 < 1 s DMV-D /11: < 1 s DMV-DLE /11: approx. 20 s at room temperature +20 C and without fast stroke Adjustable DMV-D.../11 and DMV-DLE adjustable at V1, DMV-503/11 at V2 Materials of gas conveying parts Ambient temperature Housing: Seals at valve seat: -15 C to +60 C aluminium, steel, no non-ferrous metals NBR basis, suitable for gases as per G260/l Installation position Dirt trap Measuring gas connection Ignition gas connection Burner pressure monitor p Br Voltage/frequency Rating / power consumption Degree of protection Switch-on duration Electrical connection Radio interference Closed position signal contact Solenoid vertically upright to lying horizontally Sieve installed. To protect the complete gas train we recommend you to install an upstream gas filter (refer to Datasheet 11.02) G 1/8 DIN ISO 228 on both sides upstream of V1, between V1 and V2, downstream of V2 at input and output flanges. Pressure switch can be mounted to input and output flanges. By mounting a pressure switch, measuring/ignition gas connection can be partly excluded. G 1/2 ignition gas flange as per ISO 228, possible on both sides between V1 and V2 Connection downstream of V2 GW...A2 pressure switch can be mounted to the adapter laterally and to the flange 50-60 Hz, 220 V - 240 V AC, -15 % +10 %, further voltages on request Other preferred voltages: 50-60 Hz, 110 V - 120 V AC, 24 V - 28 V DC at 230 V AC, +20 C: refer to type overview IP 54 % Plug connection as per DIN EN 175301-803, PG* 11 cable gland on request (* = heavy-gauge conduit thread) Degree of interference N Type K01/1 (DIN tested), can be mounted to V1 and V2, DMV-503/11 only to V2 2 6

Dimensions for DMV-D/11 and DMV-DLE/11 Rp d e Space requirement for mounting the solenoid c Rp c d e a b Connection to DMV-503/11: M4 screw plug f g a b f g Version Order No. p max. [bar] Connection Rp a Dimensions [mm] b c d e f g Rating [VA] Switching [kg] Weight rate h/ 1) Solenoid No. DMV-D 503/11 DMV-D 507/11 DMV-D 512/11 DMV-D 520/11 DMV-D 525/11 222 326 222 331 222 336 221 924 223 367 Rp 3/8 - Rp 1/2 Rp 1/2 - Rp 1 Rp 1 - Rp 1-77 93 162 121 141 174 201 239 30 88 109 134 150 190 255 190 232 254 99 333 99 400 103 123 65 90 110 1 1111 1211 1212 1411 1.7 2.1 4.6 5.6 12.1 DMV-DLE 503/11 DMV-DLE 507/11 DMV-DLE 512/11 DMV-DLE 520/11 DMV-DLE 525/11 Flange 222 327 222 332 222 337 222 599 223 3 Rp 3/8 - Rp 1/2 Rp 1/2 - Rp 1 Rp 1 - Rp 1-77 93 162 121 141 174 201 239 30 88 125 160 179 218 275 190 232 254 99 333 99 400 103 123 65 90 110 1 1111 1211 1212 1411 1.8 2.2 4.7 5.7 12.3 1) Switching rate of DMV-DLE 50.../11 depends on opening time setting for DMV /11 Rp 3/8 Rp 1/2 Rp 1/2 Rp 3/4 Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/2 217 471 217 472 222 341 222 342 222 001 222 343 222 344 221 884 221 926 215 384 NPT 1/2 222 371 NPT 3/4 222 368 NPT 1 221 999 NPT 1 222 369 NPT 1 1/4 222 370 NPT 1 1/2 222 003 NPT 2 221 997 NPT 2 232 407 DMV 525/11 3 6 Plug connection as per DIN EN 175301-803 210 319 - DMV 525/11 Important: Always order flange, plug connection and system accessories separately.

Equipment variants of DMV.../11 double solenoid valve, single-stage mode DMV 512/11 DMV 520/11 DMV 525/11 DMV-D DMV-DLE Sieve Microfilter element, two-layer Refer to pressure losses () () () () Gas pressure switch can be mounted: on flange downstream of sieve downstream of valve 2 to adapter downstream of valve 2 Valve V1, double-seat Valve V2, single-seat Valve V2, double-seat Valves opening separately Flange Rp 3/8 Rp 1/2 Rp 3/4 Rp 1 Rp 1 1/4 Rp 1 1/2 G 1/2 ignition gas flange can be mounted G 3/4 ignition gas flange can be mounted = standard () = on request -- = not possible Flow losses in (m 3 /h) air when installing the microfilter element Pressure loss [mbar] DMV 512/11 DMV 520/11 DMV 525/11 2 5 10 20 40 70 0.15 0.25 0.30 0.33 0.36 0.39 1.20 1.70 1.80 1.90 2.30 2.50 9.0 11.0 13.2 16.0 18.4 22.5 17.5 21.5 27,0 34.5.0 56.0 4 6

Double solenoid valve modular system Ignition gas valve Ignition gas flange P e, max. = 500 mbar V1 V2 Pressure switch can be mounted on flange FRI DMV Min. gas pressure switch DMV.../11 double solenoid valve with upstream FRI.../6 pressure regulator Valve proving system Max. gas pressure switch Gas pressure limiter on adapter Closed position signal contact Ignition gas flange Ignition gas valve P e, max. = 500 mbar V1 V2 Pressure switch can be mounted on flange DMV FRI Min. gas pressure switch DMV.../11 double solenoid valve with downstream FRI.../6 pressure regulator Valve proving system Max. gas pressure switch Gas pressure limiter on adapter Closed position signal contact Gas pressure regulator, type FRI The DMV-507-520/11 double solenoid valve is already prepared for connection with the gas pressure regulator, type FRI.../6 at the factory. The pressure regulator can be installed upstream or downstream of the double solenoid valve depending on the task. FRI.../6 mounting set to DMV.../11 Order No. 219 967 FRI 705-707/6 to Order No. 219 968 FRI 710-712/6 to DMV 512/11-520/11 Information on system accessories VPS 504 valve proving system Pressure regulator with integrated FRI gas filter Pressure limiter ÜB, NB...A2 for multiple actuators Compact pressure switch for multiple actuators GW A5 K01/1 closed position signal contact to monitor closed position of valves If a system accessory is added, it may not be possible to mount further devices. 5 6

Double solenoid valve Flow diagram Rp 3/8 - nominal diameters DMV-D/11 DMV-DLE/11 f = Dichte Luft Spec. weight air poids spécifique de l'air peso specifico aria Dichte des verwendeten Gases Spec. weight of gas used poids spécifique du gaz utilisé peso specifico del gas utilizzato Gas type Nat. gas City gas LPG Air Density [kg/m 3 ] 0.81 8 2.08 1.24 dv 0.65 0.47 1.67 1.00 f 1.24 1.46 0.77 1.00 V verwendetes Gas/gas used/ gaz utilisé/gas utilizzato = V Luft/air/air/aria x f We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Siemensstraße 6-10 D-660 Urbach, Germany Telephone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 6 6