This document just gives a not complete description of the ELTEK Flatpack product line marketed by T-Network Kft. in Hungary and in the surrounding countries. This document is part of our web page. In case you need more information please contact us. Flatpack MPSU 3000 system The Flatpack MPSU 3000 has been specifically designed to meet the demand for higher capacity and more compact power solutions. It is suitable for applications needing an expandable, easily serviceable and reliable power supply, fitting within a minimal space. The Flatpack MPSU 3000 is a compact power system, controlled by the Flatpack MCU Monitoring and Control Unit. It can house up to 2 Flatpack 1500 rectifier modules. Switch mode technology with soft switching and high switching frequency is used to minimize volume and weight and to obtain fast output voltage regulation. The system accepts large variations on the input voltage (85-300 VAC) and draws sinusoidal current with a soft start power-up. The Flatpack MPSU 3000 will operate in ambient temperatures up to +60 C (+140 F). At higher temperatures, each rectifier will derate the output power for self-protection. ELTEK Flatpack Product Line TN_2004.09.23. 1/10 page
FLATPACK MPSU 3000 4U SPECIFICATIONS Max. number of rectifiers 2 AC INPUT Voltage Frequency Maximum Current Protection MONITORING Monitoring Unit Local operation Remote operation Alarm relays Visual indications Digital inputs Current measurements Alarms 1 phase 230 VAC 3 phase 230 VAC ( ) 3 phase 400 VAC+N ( Y ) 45 to 66Hz See Flatpack 1500 48VDC datasheet (241114.100.DS3 v.07) or Flatpack 1500 24VDC datasheet (241114.300.DS3 v.01) specifications Soft start Surge protection (varistors) Internal fuses (L & N) Disconnect above 312 VAC Flatpack MCU Menu driven software via keypads and LCD or PC (WinPower) WinPower via modem NMS via SNMP-agent 6 relays are standard 5 extra relays are optional Green LED System ON Red LED Active alarm(s) LCD system status 4 (for monitoring of external equipment) Battery current Rectifier current Load fuse alarm Battery fuse alarm LVD operated Low output voltage alarms (2 individual alarm levels) High output voltage alarms (2 individual alarm levels) Low voltage level 1 Low voltage level 2 DC OUTPUT Voltage Current 48 VDC, 24VDC See Flatpack 1500 48VDC datasheet (241114.100.DS3 v.07) or Flatpack 1500 24VDC datasheet (241114.300.DS3 v.01) specifications DC DISTRIBUTION OPTIONS No. of Load breakers No. of Battery fuses Programmable LVD CONNECTIONS Battery Load MCB Alarm 2 x 125 Amps Siemens MCBs 11 x Siemens 5SY6 MCBs or 15 x CBI Q-serie MCBs 2 of 200 Amps each or 4 of 100 Amps each Standard: 1 LVBD (max 250A) Optional: 1 LVLD (max 250A) Battery cable, M6 bolts 48VDC: Negative, directly in the breakers, Positive, common positive bus bars 24VDC: Positive, directly in the breakers Negative, common negative bus bars Plug-in wire connectors rear access OTHER SPECIFICATIONS Isolation Operating Temp Storage Temp Dimensions Weight 3.0 KVAC input and output 1.5 KVAC input earth 1.0 KVDC output earth -40 to +60 C (-40 to +140 F) -40 to +85 C (-40 to +185 F) 442 x 350 x 178mm (4U) (wxdxh) (17.4 x 13.7 x 7 ) Approx. 7kg (15.5lbs) excl. rectifiers APPLICABLE STANDARDS Electrical safety EN 60950 UL 60950 EMC ETSI EN 300 386 V.1.3.1 (telecommunication network) EN 61000-6-3 (emission, light industry) EN 61000-6-2 (immunity, industry) Environment ETSI EN 300 019-2 ETSI EN 300 132-2 Specifications are subject to change without notice. ORDERING INFORMATION Part no. Description MF0200.xxx FLATPACK MPSU 3000 19 4U 48V 241114.100 FLATPACK 1500 48V 230 VAC rectifier module 351461.003 User manual FLATPACK power system 3U distribution 351461.013 Operational Guide Flatpack 1500 rectifier module 3U distribution 241114.300 FLATPACK 1500 24V 230 VAC rectifier module MF0200.xxx FLATPACK MPSU 3000 19 4U 24V ELTEK Flatpack Product Line TN_2004.09.23. 2/10 page
Rectifier battery charger Flatpack 700 48VDC The Flatpack 700 48VDC is a battery charger and rectifier for stand-alone use, or for working in parallel as part of a power rack system controlled by the Flatpack MCU Monitoring & Control Unit. When connected in parallel, the rectifiers provide active current sharing, with or without the Monitoring & Control Unit. Switch mode technology with soft switching and high switching frequency is used to minimize volume and weight, and to obtain fast output voltage regulation. The module accepts large variations on the input voltage and draws sinusoidal current with a soft start power-up. The Flatpack 700 48V will operate in ambient temperatures up to +70 C (+158 F). At higher temperatures, the rectifier will derate the output power and deliver the maximum possible power until it goes into an over-temperature shutdown. The rectifier provides 700 W power for universal input voltage range. ELTEK Flatpack Product Line TN_2004.09.23. 3/10 page
FLATPACK 700 48 V SPECIFICATIONS INPUT Input voltage Frequency Maximum Current Power factor Input protection OUTPUT Voltage Output power Maximum current Current share Static voltage regulation Dynamic voltage regulation Hold up time Ripple and Noise Output Protection 85-312 VAC* 45 to 66Hz 7.5 Arms maximum at 110VAC 3.6 Arms maximum at 230VAC > 0.99 at 50% load or more Soft start Surge protection (varistors) Internal fuses (L & N) Disconnect above 312VAC 48 VDC (range: 44-59 VDC) 600 W at 85-99 VAC 700 W at 99-312 VAC 15 Amps at 48 VDC ±1.2 Amp from true average current between modules ±0.5% from 0 to full load ±2% for 10-90% or 90-10% load variation, regulation time < 10ms 20ms; output voltage > 44 VDC < 100 mv peak to peak, 30 MHz bandwith < 0.96mV rms psophometric Overvoltage shutdown Reverse current blocking Short circuit proof High temperature protection *Above 275 VAC some parameters may vary outside given values. OTHER SPECIFICATIONS Efficiency Isolation Rectifier Alarms Visual indications Operating temp Storage temp Cooling Fan Speed MTBF Acoustic Noise Humidity Dimensions Weight > 88% at 110VAC > 90% at 230VAC 3.0 KVAC input and output 1.5 KVAC input earth 1.0 KVDC input earth Mains failure Module failure Overvoltage shutdown Fan failure Green LED: ON, no faults Red LED: Rectifier failure Yellow LED bargraph: 10 LEDs showing load current (0-15A) -40 to +70 C (-40 to +158 F) -40 to +85 C (-40 to +185 F) 2 fans (front to back airflow) Brushless w/ magnetic bearing Temperature regulated > 210,000 hours Telcordia Issue I, method III (a) < 55dBA (sound pressure) Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing 214 x 41.5 x 243mm (wxhxd) (8.43 x 1.64 x 9.57 ) 2.8kg (6,17lbs) APPLICABLE STANDARDS Electrical safety EN 60950 EMC UL 60950 ETSI EN 300 386 V.1.3.1 (telecommunication network) EN 61000-6-3 (emission, light industry) EN 61000-6-2 (immunity, industry) Telcordia GR1089 CORE Harmonics EN 61000-3-2 Environment ETSI EN 300 019-2 ETSI EN 300 132-2 Telcordia GR63 CORE Zone 4 Specifications are subject to change without notice. ORDERING INFORMATION Part no. Description 241114.400 FLATPACK 700 48V rectifier module ELTEK Flatpack Product Line TN_2004.09.23. 4/10 page
Rectifier battery charger Flatpack 1500 48VDC The Flatpack 1500 48V is a battery charger and rectifier for stand-alone use, or for working in parallel as part of a power rack system controlled by the Flatpack MCU Monitoring & Control Unit. When connected in parallel, the rectifiers provide active current sharing, with or without the Monitoring & Control Unit. Switch mode technology with soft switching and high switching frequency is used to minimize volume and weight, and to obtain fast output voltage regulation. The module accepts large variations on the input voltage (85-300 VAC) and draws sinusoidal current with a soft start power-up. The Flatpack 1500 48V will operate in ambient temperatures up to +70 C (+158 F). At higher temperatures, the rectifier will derate the output power and deliver the maximum possible power until it goes into an over-temperature shutdown. The rectifier provides 1500 W output power at 230 VAC nominal input voltage. The rectifier provides max. 600 W output power at 48 VDC at 120 VAC nominal input voltage. ELTEK Flatpack Product Line TN_2004.09.23. 5/10 page
FLATPACK 1500 48 V SPECIFICATIONS INPUT Input voltage Frequency Maximum Current Power factor Total harmonic distortion (THD) Input protection OUTPUT Voltage 85-312 VAC 45 to 66Hz 9.2 Arms maximum at 185 VAC and 1500 W output > 0.99 at 50% load or more < 5% Soft start Surge protection (varistors) Internal fuses (L & N) Disconnect above 312VAC 48 VDC (range: 44-59 VDC) Output power 550 W at 85-150 VAC 1100 W at 150-185 VAC 1500 W at 185-275 VAC Maximum current 31.25 Amps at 48 VDC (230 VAC nom.) Current share ±1 Amp from true average current between modules Static voltage regulation ±0.5% from 0 to full load Dynamic voltage regulation Hold up time Ripple and Noise Output Protection ±1.0% for 10-90% or 90-10% load variation, regulation time < 10ms 20ms; output voltage > 44 VDC < 100 mv peak to peak, 30 MHz bandwith < 0.96mV rms psophometric Overvoltage shutdown Blocking diode Short circuit proof High temperature protection OTHER SPECIFICATIONS Efficiency > 90% Isolation 3.0 KVAC input and output 1.5 KVAC input earth 1.0 KVDC input earth Rectifier Alarms Mains failure Module failure Overvoltage shutdown Fan failure Visual indications Green LED: ON, no faults Red LED: Rectifier failure Yellow LED bargraph: 10 LEDs showing load current (0-100%) Operating temp -40 to +70 C (-40 to +158 F) Storage temp -40 to +85 C (-40 to +185 F) Cooling 2 fans (front to back airflow) Brushless w/ magnetic bearing Fan Speed Temperature regulated MTBF > 213,600 hours Telcordia Issue I, method III (a) Acoustic Noise < 55dBA (sound pressure) Humidity Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing Dimensions 214 x 41.5 x 243mm (wxhxd) (8.43 x 1.64 x 9.57 ) Weight 2.8kg (6,17lbs) APPLICABLE STANDARDS Electrical safety EN 60950 EMC UL 60950 ETSI EN 300 386 V.1.3.1 (telecommunication network) EN 61000-6-3 (emission, light industry) EN 61000-6-2 (immunity, industry) Telcordia GR1089 CORE Harmonics EN 61000-3-2 Environment ETSI EN 300 019-2 ETSI EN 300 132-2 Telcordia GR63 CORE Zone 4 Specifications are subject to change without notice. ORDERING INFORMATION Part no. Description 241114.100 FLATPACK 1500 48V 230VAC rectifier module ELTEK Flatpack Product Line TN_2004.09.23. 6/10 page
Flatpack MCU Flatpack MCU Monitoring and Control Unit The Eltek range of monitoring and control units has been specifically developed to provide indication and management for DC standby power systems used in telecommunications and industrial applications The Flatpack MCU is the Monitoring & Control Unit in Eltek s Flatpack Power Supply Systems. The unit allows both local and remote monitoring/control of the Power Supply System via front keypads and LCD and an RS-232 serial interface. The Flatpack MCU offers features like Front panel LCD and keypad for on-site service (local operation) RS-232 interface for PC connection or remote monitoring/control via modem or SNMP agent 6 user programmable relay outputs for traditional remote monitoring (extendable to 11 relays) 5 user programmable inputs for monitoring of other equipment on site Battery monitoring and testing without site attendance Temperature Compensated Charge Voltage for increased battery lifetime Hot Plug-In Modem Callback functionality Password protected operator access levels Alarm/event log with time and date Site Text/ID Windows-based PC communication software (WinPower Silver) ELTEK Flatpack Product Line TN_2004.09.23. 7/10 page
Flatpack MCU Monitoring & Control Unit REMOTE MONITORING/CONTROL From a PC running WinPower With the Windows-based WinPower communication program installed on a remote computer, the system can be monitored and controlled via modems. Modem Callback functionality can be used to minimize the traffic on the public telephone network. From an NMS via Ethernet (SNMP) With an external SNMP agent connected to the Flatpack MCU, the system can be monitored and controlled from a Network Management System through Ethernet on Simple Network Management Protocol (SNMP). Using alarm relays (voltage free contacts) 6 internal failsafe alarm relays provide voltage free contacts that can be connected to equipment used for traditional alarm monitoring. 5 extra relays can be delivered as an option, providing a total of 11 alarm relays. LOCAL MONITORING /CONTROLING From a PC running WinPower WinPower can also communicate with the Flatpack MCU through an RS-232 C serial cable. Using front keypads and display Flatpack MCU uses menu driven software to provide a user-friendly interface for local operation via a keypad and an LCD. In normal operation, the front LCD will display the output voltage, battery current, rectifier current and load current. If any alarm is activated, a red LED is lit in the front panel, the alarm text appears in the LCD and the corresponding alarm relay is activated. FEATURES Output Voltage Measurement Load Current Measurement (calculated) Battery Current Measurement Rectifier Current Measurement Battery Temperature Measurement (optional) Load/Battery Disconnect Alarm Level Settings Battery Testing (interval and manual) Battery Test Information (2 latest tests) Setup of Battery Data Alarm Log Parameter Calibration Clock and Date adjustment Real Time Clock with Battery Backup Site Text/ID Test of Relay Outputs Voltage Level Programming Battery Boost Charging Battery Cable Voltage Drop Compensation Temperature Compensated Charging Modem Callback AVAILABLE ALARMS High Battery voltage 1 (Level 1) High Battery voltage 2 (level 2) Low Battery voltage 1 (Level 1) Low Battery voltage 2 (Level 2) Load Disconnect (Voltage or timer) Battery Disconnect (Voltage or timer) Battery Fuse Alarm Load Fuse Alarm High Battery temp. 1 (level 1) High Battery temp. 2 (level 2) Low Battery temp. Battery Pre Alarm (75% < capacity < 85%) Battery Failure (capacity < 75%) Mains failure Rectifier failure (1 module) Critical Rectifier failure (> 1 module) Symmetry Failure Battery Test (ongoing test) Digital Inputs 1-5 (w. programmable names) Rectifier Capacity w. programmable level Low temp. w. programmable level Temperature probe Battery discharge SPECIFICATIONS Input Voltage: Prepared for 24/48/60 VDC nominal system voltages Dimensions: 123 x 43 x 177mm (WxHxD) (4.85 x 1.7 x 6.97 ) Weight: 0.7kg (1.55lbs) ORDERING INFORMATION Part no. Description 242072.600 Flatpack MCU 351300.013 Operation Guide, Flatpack MCU ELTEK Flatpack Product Line TN_2004.09.23. 8/10 page
PRSB 9000 Power Rack System The Flatpack PRSB 9000 has been specifically designed to meet the demand for higher capacity and more compact power solutions. The Flatpack PRSB 9000 is a compact power system, controlled by the Flatpack MCU Monitoring and Control Unit. It can house up to 6 Flatpack 1500 rectifier modules and capable of handling up to 250Amps. Switch mode technology with soft switching and high switching frequency is used to minimize volume and weight and to obtain fast output voltage regulation. The system accepts large variations on the input voltage (85-310 VAC) and draws sinusoidal current with a soft start power-up. The Flatpack PRSB 9000 will operate at full power in ambient temperatures up to +60 C (+140 F). At higher temperatures, each rectifier will de-rate its output power and deliver the maximum possible power at a reduced level until it goes into over-temperature shutdown. It is suitable for applications needing an expandable (from one to four battery banks), easily serviceable and reliable power supply, fitting within a minimal space. ELTEK Flatpack Product Line TN_2004.09.23. 9/10 page
FLATPACK PRSB 9000 SPECIFICATIONS Max. number of rectifiers 6 AC INPUT Voltage Frequency Maximum Current Protection MONITORING Monitoring Unit Local operation 1 phase 230 VAC 3 phase 230 VAC ( ) 3 phase 400 VAC+N ( Y ) 45 to 66Hz See Flatpack 1500 48VDC datasheet (241114.100.DS3) Soft start Surge protection (varistors) Internal fuses (L & N) Disconnect above 310 VAC Flatpack MCU Menu driven software via keypads and LCD or PC (WinPower) Alarm relays 6 relays are standard 5 extra relays are optional Visual indications Green LED System ON Red LED Active alarm(s) LCD system status Digital inputs 5 (for monitoring of external equipment) Current readings Battery current, Load Rectifier current Alarms Load fuse alarm Battery fuse alarm LVD operated Low output voltage alarms (2 individual alarm levels) High output voltage alarms (2 individual alarm levels) DC OUTPUT Voltage 48 VDC, 24VDC Current See Flatpack 1500 48VDC datasheet (241114.100.DS3) CONNECTIONS Battery Load MCB Alarm Battery cable, M6 bolts Negative, directly in the breakers, Positive, 2 common positive bus bars Plug-in wire connectors located in the top-front of the MCU DISTRIBUTION OPTIONS Load breakers Battery fuses Programmable LVD 2 x 63-125A Siemens MCB s 11 x Siemens 5SY4 MCB s or 15 x CBI, Q-serie MCB s 2 of 200 Amps each or 4 of 100 Amps each Standard: 1 LVBD (max 250A) Optional: 1 LVLD (max 250A) OTHER SPECIFICATIONS Isolation 3.0 KVAC input and output 1.5 KVAC input earth 1.0 KVDC output earth Operating Temp -40 to +60 C (-40 to +140 F) Storage Temp -40 to +85 C (-40 to +185 F) Dimensions 600 x 600 x 630mm (wxdxh) (23,6 x 23,6 x 24.8 ) 600 x 600 x 900mm (wxdxh) (23,6 x 23,6 x 35.4 ) 600 x 600 x 1800mm (wxdxh) (23,6 x 23,6 x 70.9 ) Weight 630mm: Approx. 35kg (77lbs) excl. rectifiers 900mm: Approx. 40kg (88lbs) excl. rectifiers 1800mm: Approx. 70kg (154lbs) excl. rectifiers APPLICABLE STANDARDS Electrical safety EN 60950 EMC ETSI EN 300 386 V.1.3.1 (telecommunication network) EN 61000-6-3 (emission, light industry) EN 61000-6-2 (immunity, industry) Environment ETSI EN 300 019 Specifications are subject to change without notice. ORDERING INFORMATION Part no. Description CF0618.01K Flatpack PRSB 9000, 900mm CF0613.01K Flatpack PRSB 9000, 630mm CF0638.01K Flatpack PRSB 9000, 1800mm 241114.100 FLATPACK 1500 48V 230VAC rectifier module ELTEK Flatpack Product Line TN_2004.09.23. 10/10 page