Single or current-compensated chokes are used, also depending on the requirement.

Similar documents
Line Reactors and AC Drives

DS 600. A contact free flux gate based current measurement sensor 600A rms

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Power Supplies. 1.0 Power Supply Basics. Module

Current Probes. User Manual

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Properties of electrical signals

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Module 11: Conducted Emissions

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

38 Series - Relay interface modules A

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

How to design SMPS to Pass Common Mode Lightning Surge Test

Guidance for upgrading to GB (IEC : 2005, MOD)

FILM CAPACITORS FOR ELECTRONIC LIGHTING

RC NETWORKS SALES GUIDE

Voltage Regulator SPAU 341 C. Product Guide

Energy Management Energy Meter Type EM23 DIN

= V peak 2 = 0.707V peak

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

Three-phase monitoring relay CM-PFE

Grounding Demystified

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

FREQUENCY CONTROLLED AC MOTOR DRIVE

38 Series - Relay interface modules A

AMP CO Plus Insert for Cat. 6 A Applications

VOLTAGE REGULATOR AND PARALLEL OPERATION

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Adding Heart to Your Technology

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

High-ohmic/high-voltage resistors

Power surges can also be generated by equipment in your facility such as:

High-ohmic/high-voltage resistors

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

Technical Article. EMC filters for medical devices

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

15 Series - Electronic step relay and dimmer. Features SERIE

handbook, 2 columns handbook, halfpage 085 CS

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

EMC Filters Guide REO UK LTD

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

40 Series - Miniature PCB/Plug-in relays A. Features

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Rack mounted telephone- and leased line modem for industrial applications

Product Data Bulletin

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Safety technique. Emergency stop module BO 5988 safemaster

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Telecommunication Line Protectors

SURGE PROTECTIVE DEVICES

Instrument Transformers Application Guide

LM118/LM218/LM318 Operational Amplifiers

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Balun Parameter Definitions & Measurement May 2004

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

HOW TO SELECT VARISTORS

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

SINEAX U553 Transducer for AC Voltage

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

I-PEX MHF4 Micro Coaxial Connector

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

80 Series - Modular timers 16 A. Features

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

48 SERIES Relay interface modules 10 A

Measuring Impedance and Frequency Response of Guitar Pickups

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Rectifier circuits & DC power supplies

EARTHING SYSTEM CALCULATION

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Transcription:

1 Introduction Shielded rooms offer protection against electromagnetic fields. This works two ways, i.e. shielding a room against the external electromagnetic environment, shielding the environment against electromagnetic interference produced inside a room. The first case applies to research and development or test installations, computer centers or medical equipment, which will only work properly with adequate protection against RF energy from the outside. In the second case, e.g. use of spark machining equipment, high-voltage tests or measurement of breakdown field strength, the RF energy that is generated would not only disturb radio and TV reception, it would also impair the working of any electrical equipment close by. In many instances you have to both protect equipment against sinusoidal stray signals and limit pulsed interference. The latter includes electromagnetic pulses (EMP), a cover term for the effects of lightning (LEMP) and the impact of a nuclear detonation (NEMP). To prevent interference or surge voltages from penetrating or escaping from a shielded room, all lines passing through the shield need to be fitted with appropriate filters. 2 EMC filters 2.1 Design Our standard filters come in an RF-tight case for wall mounting and include single or multiple filter circuits depending on the requirement. For higher amperage, the filters are designed as RF-tight cabinets. Single or current-compensated chokes are used, also depending on the requirement. Single chokes damp common-mode and differential-mode currents equally well. The large gapping, e.g. through the outer air gap in I core chokes, prevents saturation of the magnetic core by the operating current. A disadvantage, however, is that single chokes for high operating currents are voluminous and costly. Current-compensated chokes damp for the most part common-mode interference currents, because the magnetic fluxes in the core produced by the operating current and differential-mode current are compensated by the special arrangement of the windings. The advantage here is that the choke remains relatively small in volume even for high operating currents. 2.2 Insertion loss The insertion loss of filters is determined according to CISPR 17. This specification is stricter than the frequently used MIL-STD-220A, where only an open-circuit measurement is required in the frequency range below 100 khz. The loss figures for all EPCOS filters apply for full load in the stated frequency range (refer to section 4.12 for measurement methods). 1

2.3 Protective measures (grounding) The high capacitances between the lines and ground require special protective measures. If there are no product-specific requirements, protection with a secondary ground wire (cross section min. 10 mm 2 ) in accordance with EN 50178 is necessary. For this purpose the filter case have connecting bolts at each end. Resistors are incorporated in the filter to discharge capacitors after turn-off. 3 EMP protection The danger to electrical and electronic equipment and systems from electromagnetic pulses is characterized by fields of the order of kilovolts per meter and amps per meter. Where NEMP is concerned, rise and fall times of just a few nanoseconds to a few hundred nanoseconds must be taken into account. If interference pulses in the nanosecond range are produced on lines by fields of this magnitude, they can be damped by the feed-through capacitors used in the filters or EMP protection units. Seeing as line systems (power, control and communication lines) exhibit a lowpass response however, they primarily transmit overvoltages in the microsecond range. The short field pulse also stimulates them into natural oscillation, which, depending on the nature and size of the line system, can lie in the frequency range from a few kilohertz to several megahertz. Extra surge protection is needed to reduce these overvoltages. Ignoring the possibility of a direct lightning strike on the filter or surge protection unit, the connected line is always determinant for the coupling in and transmission of overvoltages. The peak of a surge is thus clearly limited by the withstand voltage of the line carrying the surge pulse and the connector fittings. In common power systems you cannot expect a figure of more than 20 kv for surge voltage strength. For communication lines it is less. The high-frequency internal resistance is between 10 and 50 Ω. An internal resistance of 10 Ω and a maximum voltage of 20 kv thus produce an unbalanced to ground, sum current of max. 2 ka for a cable. The current per line is correspondingly lower. 2

3.1 Test conditions In consideration of what is said above, and which is acknowledged by many official bodies in the absence of appropriate standards, you arrive at the following test conditions: Surge voltages: Rate of rise 100 V/µs 1 kv/µs internal resistance R i = 15 Ω 10 kv/µs 1 kv/ns internal resistance R i = 50 Ω bzw. 90 Ω Amplitudes in the specifications of the particular filters with EMP protection or EMP protection unit Surge currents: Standard wave 8/20 µs Long wave 10/700 µs Surge voltage tests serve primarily for testing the response of nonlinear protection elements, the pulse damping performance of the protection unit as a whole. Surge current tests (impressed currents) serve for determining the energy carrying capability (absorption or reflection) of the protection units. Note: The values for rated surge current listed in the filter specifications were given to illustrate the response of the protection units under extreme load. They cannot be produced by an NEMP. Those filters with integrated overvoltage protection and the EMP protection units all underwent representative type testing by the Defense Technology Office of the Federal German Army in Munster. The results are available on request. The basic units of filters with overvoltage protection are the filters for electromagnetic compatibility. The overvoltage protection is housed in an add-on case or in the filter case itself, partly together with extra nonlinear components in the filter configuration. 3

4 Terms and definitions 4.1 Rated voltage V R The rated voltage V R is either the maximum rms operating voltage at the rated frequency or the highest DC operating voltage which may be continuously applied to the filter at temperatures between the lower category temperature T min and the upper category temperature T max. Filters which are rated for a frequency of 50/60 Hz may also be operated at DC voltages. 4.2 Nominal voltage V N The nominal voltage V N is the voltage which designates a network or electrical apparatus and to which specific operating characteristics are referred. IEC 60038 defines the most widely used nominal voltages for public supply networks. It is recommended that the voltage at the transfer points should not deviate from the nominal voltage by more than ±10% under normal network conditions. 4.3 Difference between rated and nominal voltage For filters, the rated voltage is defined as a reference parameter. It specifies the maximum voltage at which the filter can be continuously operated. This voltage must never be exceeded, as otherwise damage may occur. Only small deviations are tolerated, such as may occur when a filter with a rated voltage of 250 V is operated at in a network with a nominal voltage of 230 V (230 V +10% = 253 V). Short voltage surges are permitted according to EN 133200. Figure 1 Difference between rated and nominal voltage 4

4.4 Test voltage V test The test voltage V test is the AC or DC voltage which may be applied to the filter for the specified test duration at the final inspection (100% test). This test may be repeated once as an incoming goods inspection or equipment test. 4.5 Voltage drop V The voltage drop is the difference between the filter input voltage and output voltage produced by applying the rated current to the filter. 4.6 Rated current I R The rated current I R is the maximum AC or DC current at which the filter can be continuously operated under nominal conditions. Above the rated temperature T R, the operating current should as a rule be reduced in accordance with the derating curves (see also figure 2). For 2-line filters, the rated current is specified for the simultaneous flow of a current of this value through all the lines. For 4-line filters (e.g. filters with 3 phases and neutral line), the sum of the currents in all 4 lines must not exceed three times the rated current. Higher thermal loads may occur during AC operation due to non-sinusoidal waveforms. These must be taken into account where necessary. 4.7 Overcurrent I over The rated current may be exceeded for a short time. Details of permissible currents and load durations are specified in the various data sheets. 4.8 Capacitive reactive current I reactive The capacitive reactive current is the current that flows in operation across the capacitors used in a filter. The figures are referred to 230 V nominal voltage for 2-line filters and 400/230 V for 4-line filters and a rated frequency of 50 Hz. 4.9 Power dissipation P D The power dissipation in the case of 2-line filters refers to a simultaneous load with the specified rated current. With 4-line filters (filter with 3 phases and neutral line) the sum of all 4 lines must not exceed three times the rated current. 5

4.10 Current derating I/I R The filters are dimensioned for continuous operation at the rated voltage and frequency. They are designed for operation at the full rated current up to specified rated temperature (as a rule 40 C). When they are operated at ambient temperatures T A which exceed this temperature, the maximum permissible continuous operating current is obtained by multiplying the rated current by the corresponding derating factor: Figure 2 Current handling capability I/I R as a function of ambient temperature T A (upper category temperature = 85 C) 4.11 DC resistance R The DC resistance is the resistance of a line measured for direct current at an ambient temperature of 20 C, where the measuring current must be selected substantially lower than the rated current. The data sheets state the maximum value R max. 6

4.12 Insertion loss The insertion loss is a criterion for the efficiency of EMC components, as measured by using a standardized test setup (Figure 3). Figure 3 Definition of insertion loss The input terminals of the filter under test are connected to an RF generator with impedance Z (usually 50 Ω). At the output of the filter, the voltage is measured using an RF voltmeter having the same impedance Z. The insertion loss is then calculated from the quotient of half the opencircuit generator voltage V 0 and the filter output voltage V 2. Insertion loss measuring methods used for EMC filters with 2 lines a) Differential mode (symmetrical insertion loss measurement) Figure 4 Symmetrical insertion loss measurement to CISPR 17 (1981) Fig. B5 7

b) Common mode (asymmetrical measurement), branches connected in parallel Figure 5 Asymmetrical insertion loss measurement to CISPR 17 (1981) Fig. B6 or MIL-STD 220A Common-mode measurement with lines connected in parallel is widely used in the United States. Some diagrams in this data book show the results of this measurement in addition to those obtained according to a) and c). c) Unsymmetrical measurement, adjacent branch terminated Figure 6 Unsymmetrical insertion loss measurement to CISPR 17 (1981) Fig. B7 The termination of the adjacent line with a defined resistance value has not yet been standardized. As far as this data book contains insertion loss characteristics determined by other measuring arrangements, the deviations are indicated where the relevant diagrams are shown. 4.13 Leakage current l leak The leakage current l leak is the current that flows to ground or to an external conductive part in a circuit without any failure. For safety hints refer to data book "EMC Filters". 4.14 Discharge resistor Discharge resistors are meant to ensure that the energy stored in the capacitors is reduced to low levels within a short period, so that the voltage at the equipment terminals drops to below permissible maximum values. For safety regulations refer to data book "EMC Filters". 4.15 Further general information Refer to data book "EMC Filters", edition 2001, ordering code EPC:24004-7600. 8