AIR-TO-AIR HEAT PUMPS and AIR CONDITIONERS

Similar documents
catalog Single Package Vertical Air Conditioners and Heat Pumps

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION AIR CONDITIONING UNIT

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION HEAT PUMPS

Element D Services Heating, Ventilating, and Air Conditioning

Commercial Gas Furnace Upflow

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

MAC-120HE-01 Air-Cooled Chiller

Single Package Vertical Air Conditioners. Vert-I-Pak

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

TWE+TTA TWE+TWA T.R.

CB29M Bulletin # February 1996

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

HVAC Systems: Overview

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Low Profile Unit Cooler

ECOCIAT. Domestic hot water heat recovery unit

NSN

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Glossary of Heating, Ventilation and Air Conditioning Terms

SECTION MORTUARY REFRIGERATORS

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

RPV - RP - RA air handling units

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

ARMSTRONG AIR HEAT PUMPS

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Dehumidification Frequently Asked Questions

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Installation Manual CLIFC Fan & Coil Variable Speed

Defining Quality. Building Comfort. Heating and Cooling Coils

Split System Cooling Product Data

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Cooling/Heat Pump Convertible Air Handlers

HEATER, AIR CONDITIONING AND VENTILATION

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Cool Design for Homes and Offices

Why and How we Use Capacity Control

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

Split System Heat Pump Product Data

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Product Data. Split System Cooling F-EN. March 2015

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Bring the fresh in. Dedicated Outside Air Systems

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Split System Heat Pump Product Data

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Lesson 36 Selection Of Air Conditioning Systems

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Operation and Installation Manual. Max Series

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

marine/bespoke split applications

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

Local Dealer:

ice 3 FLUID TO FLUID HEAT PUMP

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

University of Houston Master Construction Specifications Insert Project Name

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

A. Section includes air conditioning units, controls and control panels.

Mechanical Rooftop Custom Capabilities

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Split System Cooling Product Data

SECTION GENERAL PROVISIONS FOR HVAC WORK

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

HP switch LP switch Discharge thermo Comp. Surface thermo

Why Daikin? 2015 Houston, Texas USA

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Split System Cooling Product Data

Cooling Capacity CFM in. w.c. (125 Pa)

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

CE6500 Energy Recovery Ventilator

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Heat Pump Water Heater IOM Manual

SWIMMING POOL HEAT PUMP

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

1.2 Refrigerant Equipment. General

How Ground/Water Source Heat Pumps Work

Transcription:

Eco Pak AIR-TO-AIR HEAT PUMPS and AIR CONDITIONERS 3/4 TON through 3 TON Electric or Hot Water Heating Enviro-Tec's R-410A 'VP Series' of Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps offer the ultimate in HVAC design flexibility. The Eco-Pak is a compact through-the-wall packaged system, capable of providing total heating and cooling functions for a single zone or multiple rooms. Unlike conventional horizontal equipment, each VP unit has been designed with sufficient air handling capacity for ducted installations. VP Series units are ideally suited for the perimeter zones of buildings such as: Hotels and Motels High Rise Apartments / Condominiums Hospitals / Nursing Homes Dormitories Renovated Office Space The VP unit is installed in a closet having an exterior wall. Wall mounting sleeves for various wall thickness are available for installation during building construction. Final installation is reduced to sliding the unit onto the mounting sleeve, and connecting the electrical supply. The result is a low cost installation, and allows delivery of the terminal units to be deferred until just before occupancy.

GENERAL MECHANICAL SPECIFICATIONS GENERAL All models are shipped as a factory tested through-the-wall packaged HVAC system. The unit installs in a closet having an exterior wall. VP units are designed for Wall Sleeve mounting. The Wall Sleeve is permanently built into the building wall at the rough-in stage. All units are completely factory wired and pre-piped. Condensate drain connection is via a female pipe thread fitting located on the bottom of the wall sleeve. CABINET All cabinets are completely constructed of heavy gauge, corrosion resistant, galvanized steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, high-density insulation. All models allow service access to the reversing valve (VPP units only), electric heater, condenser blower/motor, and compressor with the unit remaining in location. An integral duct collar is provided on the indoor blower discharge opening. REFRIGERATION CIRCUIT All models utilize high efficiency rotary or scroll compressors. Each refrigeration circuit is thoroughly evacuated, and fully charged with R-410A refrigerant before shipment. Internal motor overload protection is provided. Compressors are mounted on rubber isolators to minimize vibration transmission. The refrigeration circuit includes a bi-flow thermal expansion valve (with external equalizer), bi-flow liquid line filter drier, a high refrigerant pressure safety switch (manual-reset), and service gauge ports. The reversing valve (VPP units only) is a pilot operated, sliding piston type with a replaceable magnetic solenoid coil. The indoor and outdoor coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced aluminum plate fins. The coils are employed in a draw-through configuration. INDOOR / OUTDOOR FAN Forward curved, double inlet and double width, direct-drive centrifugal blowers are used for air movement. Large diameter wheels are employed to provide required airflow performance at minimum noise levels. Fan motors are PSC types, with minimum three speeds on indoor fan and one speed on outdoor fan. The PSC motors feature permanently lubricated bearings and internal thermal overload protection. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary operating controls. A factory installed electrical disconnect is provided for service convenience and maintenance. Units are designed to operate with conventional thermostat control interface. A solid state time delay relay provides both random-start, and compressor anti-short cycle protection standard in all units. Both Cooling and Heat pump models feature an ambient outdoor temperature sensor to lockout compressor operation below 40 F. Additionally, a low suction temperature thermostat is included in the compressor control circuit to prevent evaporator icing during cooling operation at lower out-door ambient temperatures. The reversing valve solenoid coil is energized in cooling mode only (VPP units only). An optional remote management relay allows the unit to be enabled or disabled from an external source. FRESH AIR INTAKE A mechanical fresh air intake, with adjustable damper, is provided to meet code requirements for fresh air introduction. This ventilation air minimizes infiltration by pressurization of the conditioned space. FILTERS All models are shipped with a 1-inch thick throwaway filter, factory installed. Filters are accessible from front of unit.

VP SERIES PRODUCT NOMENCLATURE

AIR-COOLED VERTICAL PACKAGE UNIT - AIR CONDITIONER WITH OPTIONAL ELECTRIC HEAT

AIR-COOLED VERTICAL PACKAGE UNIT - AIR-TO-AIR HEAT PUMP WITH ELECTRIC HEAT

AIR-COOLED VERTICAL PACKAGE UNIT - AIR CONDITIONER WITH HYDRONIC HEAT

INDOOR BLOWER CFM

3/4 TO 3 TON VPC & VPP DIMENSIONAL DATA

3/4 TO 3 TON VPH DIMENSIONAL DATA

10 3/4 To 3 TON ALL MODELS INSTALLATION DETAILS

ELECTRICAL DATA R-410A MODELS 11

City of New York Department of Buildings MEA Enviro-Tec maintains a continuous product improvement policy, therefore specifications are subject to change without notice. 04/08