Procedure for using ABRIO (CRi, Inc.) Imaging Equipment Compiled by Thomas Ober, Dec

Similar documents
Automatic and Objective Measurement of Residual Stress and Cord in Glass

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Eye Tracking Instructions

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

MAINTENANCE & TROUBLESHOOTING

Crystal Optics of Visible Light

Care and Use of the Compound Microscope

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

Window Glass Design 5 According to ASTM E 1300

Basics to Using the View Camera

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

MAINTENANCE & TROUBLESHOOTING

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Protocol for Microscope Calibration

Polarization of Light

Handheld USB Digital Endoscope/Microscope

KEYPAD LOCK RETROFIT KIT

AXIS 205 Network Camera Quick Installation Guide

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Compound microscope (Hund)

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

Fading Red Tones on Color LaserJet 2600s

Features: Mounting the Optic

The Basics of Scanning Electron Microscopy

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

CALIBRATING YOUR SYSTEM. Follow our guidelines carefully to ensure proper system function. EQUIPMENT

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)

VISM Evolution Scope Series

Rodenstock Photo Optics

Understanding astigmatism Spring 2003

Atomic Force Microscope

Tooway KA-SAT Installation Guide

Service Guide. Gateway M275

35mm Twin-Lens Reflex Camera

Petrel TIPS&TRICKS from SCM

Experiment 5. Lasers and laser mode structure

Lab 9: The Acousto-Optic Effect

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

Motion Activated Camera User Manual

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Create a Poster Using Publisher

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

TOF FUNDAMENTALS TUTORIAL

THE BOHR QUANTUM MODEL

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

4.3-inch Back-Up Camera

LED Security Spotlight User Manual

ScanPro 3000 High Definition Microfilm Scanner. Help Guide

Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Experiment 5: Magnetic Fields of a Bar Magnet and of the Earth

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Step by step guide to installing your own Ku Band satellite dish

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Alignement of a ring cavity laser

The Reflexion Filter. Manual. Electronics

1 DESCRIPTION OF THE APPLIANCE

TRIMMING UNIT/DIAMOND MACHINE TST.13

4. Do you have a VGA splitter ( Y Cable)? a document camera?

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

Part Name/Description Part Number Quantity. Power Cable

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

MET 306. Activity 8a. Mechanism Design Creo 2.0 Level 7 POINT A GROUND LINK LINK 1 LINK 2 LINK 3 POINT B 10/15/2010 1

OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G

Installation Instructions For Slider Casement Air Conditioners

Adobe Illustrator CS5 Part 1: Introduction to Illustrator

ALARM SYSTEM INSTALLATION GUIDE

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

RC8021 Indoor Camera Installation Guide

Application Report: Running µshape TM on a VF-20 Interferometer

Control Box Wiring For PRSstandard Tool

THE COMPOUND MICROSCOPE

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.

(I) s(t) = s 0 v 0 (t t 0 ) a (t t 0) 2 (II). t 2 = t v 0. At the time. E kin = 1 2 m v2 = 1 2 m (a (t t 0) v 0 ) 2

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Beam Laser Pointer Service Manual

CATIA Basic Concepts TABLE OF CONTENTS

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

Cooktop Low-Profile Ventilation Hoods

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

POLARIZED LIGHT MICROSCOPE EXAMINATIONS OF ORIENTED POLYMER FILMS

The RIDZ 8x2 Audio Switcher

Transcription:

Procedure for using ABRIO (CRi, Inc.) Imaging Equipment Compiled by Thomas Ober, Dec. 2008. The following procedure assumes that the ABRIO camera has been properly installed in Port 5 of the microscope and is connected to a PC on which the ABRIO software has already been installed. For instructions regarding proper installation of the camera refer to the ABRIO user manual. This procedure has been designed to guide the user up until the point where he or she is ready to use the software. It is my observation that the equivalent procedure provided by CRi, Inc. is wanting in some areas because it was designed to be broadly applicable for many different microscopes, and consequently it misses some of the subtleties pertinent to our setup. Required equipment: ABRIO Camera Nikon TE-2000U Inverted Microscope Birefringent sample Procedure: 1) Turn on computer and select Birefringence PC on the data transfer switch to have the monitor display the output of the computer connected to the ABRIO camera. 2) Select the correct filters. None of the filters located at the top of the microscope should be engaged, i.e. all of the filter panels should be in their most outward position. Filter Panels Filter A On the condenser turret, filter A should be selected with its aperture fully open.

Check that there are no other filters in the light path below the objectives. To do this remove the cover with the Warning label on it and rotate the filter turret, using the knob on the other side of the microscope stage. Take note of the position number in which there is no filter. Once you have found this number, replace the cover and rotate the turret so that the position number that you noted is now showing on the knob on the other side of the microscope stage. Rotate Position Number 3) Turn on the microscope light by toggling the switch on the remote controller box and the switch at the bottom left of the microscope. Adjust the light intensity, as desired, using the knob just below the light switch on the bottom left of the microscope. 4) Select Port 1 using the knob at the bottom right of the microscope. Grid Toggle Knob Port 1 5) Place the birefringent sample on the microscope stage and focus on the sample at whatever your desired magnification. It is generally easiest to use a lower objective first for focusing on a sample and then progressively increasing the magnification. If there is a grid in the field of view it can be removed by turning the black knob in the lower front of the microscope.

6) In this step we Koehler Illumination. The procedure for this step is well described on page 37 of the User s Manual for ABRIO 1.4. The following is taken verbatim from that manual. Close the condenser diaphragm (lever on the pillar) so that the edges of the diaphragm begin to form a polygon shape within your field of view. Adjust the condenser height using the large black knob on the condenser assembly until the edges of the diaphragm are sharply in focus. Center the diaphragm opening in your field of view using the two metal knobs on the condenser assembly. Open the condenser diaphragm until the edges just disappear from you field of view. In some cases, you may find that the condenser turret is difficult to move or it will not move down far enough to get the polygon to have sharp edges. If this happens, loosen the locking wing screw just above the right-hand condenser knob. Loosening this screw will allow for more vertical movement of the condenser. Be sure to tighten the locking screw once you have positioned the condenser. Diaphragm Lever Locking Screw Metal Knobs Knob 7) Engage both the filter above the condenser assembly by moving the slider from left to right. Engage the liquid crystal (LC) compensator below the microscope objectives by pushing it into the slot in the microscope below the objectives until the second of two clicks is heard. The filter above the condenser assembly contains a monochromatic filter (546 nm) and circular polarizer. The LC compensator contains two variable retarders and the analyzer.

Filter Engaged LC Compensator LC Compensator Engaged At this point we are ready to use the camera and the software. 1) Check the camera. Make sure that it is connected to the PC and that it is securely mounted to the microscope. The side of the camera with the words ABRIO Imaging System should be facing vertically as shown in the picture below. For accurate measurements it is important that the camera be mounted so that it is level. There is a bubble level available in the optical cabinet. For more information see chapter 3 of User s Manual for ABRIO 1.4. 2) Select Port 5 using the knob at the bottom right of the microscope. 3) Plug in the camera and check that the green lights on the back of the camera are lit and are no longer blinking. 4) Open the ABRIO software on the PC. At this point it is best to refer to the User s Manual for ABRIO 1.4 and the Quick Start Guides, as they offer a very thorough procedure for acquiring images and using the software.

Below is a list of what I think would be helpful to future users that is not explicitly stated in the User s Manual for ABRIO 1.4. Sometimes ABRIO has difficulty taking a background. If you encounter this problem consider the following: Generally the cause of its difficulty is indeed one of the problems that ABRIO mentions in the warning message. Check to see that your problem is not in the warning message. It is also possible that the connection to the camera has become stale or you simply forgot to turn on the camera. It is possible to coax ABRIO into taking a background by placing something which is birefringent (e.g. and empty PDMS channel) in the whole field of view and then having it take a background. If you still desire the background be taken through a nominally non-birefringent medium (e.g. air), after having successfully taken the background through the birefringent medium, remove it from the microscope stage and have ABRIO take a new background. (This technique is a round-about method, but it has worked more than once.). If you have tried in vain to get ABRIO to take a background, consider quitting the program, turning the camera off and then on again, reopening ABRIO and trying again. We are using the Abrio camera, not the Cooled Abrio camera. Make sure you have selected Abrio camera in the preferences window. The measured azimuthal angle (also extinction angle) is the angle between the slow axis (the optical axis of the sample having the larger index of refraction) of the birefringent sample and the horizontal (positive x-axis) of the image displayed in the ABRIO software. In other words, ABRIO can measure both the magnitude and the sign of!n. Thus ABRIO will differentiate between two materials, one with a positive stress optical coefficient, and the other with a negative stress optical coefficient, each with identical stress distributions, by measuring an azimuthal angle for one of the materials that differs from the azimuthal angle of the other material by 90 o. For this reason, it is very important that the ABRIO camera be level. With respect to the user, the orientation of an image displayed by the ABRIO software should be the same as the orientation of the sample that the user would observe if he or she were to look at the sample through the microscope. ABRIO requires a reference (background) image to account for residual birefringence in the sample. There are two ways to accomplish this: 1) Static: take an image of the sample (in this case of the PDMS) before an experiment and apply this reference image to all subsequent images. 2) Dynamic: use a witness box to designate a small region of the live image as the continuously updated background. The use and position of the witness box greatly influences the measured signal especially for samples, which are roughly as birefringent as their background. Generally the closer the witness box is positioned to the channel, the more reduced the measured retardance when there is flow.

This occurs because the PDMS walls are themselves deformed by the flowing liquid, presumably more so closer to the channel. The ABRIO software accounts for this by thinking the increased birefringence in the PDMS is an increase in the background birefringence and then subtracts this increased birefringence from the whole image (Shribak 2003). If no witness box is used, the background image taken originally is applied to the image at all times. If this background image is taken when there is no flow in the sample (i.e. minimal stress), then the measured birefringence when there is flow is higher than the birefringence measured using a witness box. I have spoken to Cathy Boutin at CRi, Inc., who has stated that for our experiments with PDMS microchannels it is best NOT to use the witness box since we are unable to position it in a region of the image where there is no flow induced stressed. Not using a witness box has the drawback that once a background image is taken, it is only relevant to the region of the sample for which it was taken, thus it is only truly applicable as long as the sample is not moved. The exposure time of an image can be found by double-clicking on an image and looking under the Image Notes tab of the display panel in the lower left-hand corner of the user interface. The exposure time is influenced by the settings in the preferences window for image taking. To get a plot of retardance and azimuthal angle along a line in the image, use the line tool and draw a line on the image, then select the Measurements tab on the display panel and select Profile Plot on the drop down menu. All of this is outlined on page 57 of the User s Manual for ABRIO 1.4. To export these profiles into spreadsheet format, right-click on the plots and select Copy. Open Excel and paste the data. If ABRIO crashes, do not worry. Both the most recent background that you took and all of your images are saved for your user session. Note: Any unsaved changes to images are, however, lost. Cleaning and maintenance: The ABRIO setup itself requires fairly little upkeep. If you desire to remove any dust from the optics do so with a hand-powered lens blower (as shown below), but NOT with compressed air. Using compressed gas to clean the lens runs the risk that some of the aerosol will be ejected as liquid and land on the lens leaving a film on the lens. References User s Manual for ABRIO 1.4 Shribak, M. and R. Oldenbourg (2003). "Techniques for fast and sensitive measurements of twodimensional birefringence distributions." Applied Optics 42(16): 3009-301

ABRIO Optical Train White Light Source Circular Polarizer/Interference Filter Circularly Polarized Light Sample Altered Light (",#) Liquid Crystal Compensator Optic Monochromatic Light Filter Polarizer Quarter Wave Plate Variable Retarder B Variable! Retarder A! = 546 nm O -45 O +45 Detector Analyzer O Computer ABRIO Camera " = retardance [nm] # = extinction angle