TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Similar documents
stainless steel pre-assembled manifolds

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

PRESSURE REDUCING CONTROL VALVE

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

PRESSURE REDUCING VALVES

VAD. Variable Area Desuperheaters

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

VAD Variable Area Desuperheaters

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

WATER PRESSURE REDUCING VALVES

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

1805 Series Relief Valves

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

VALVES FOR REFRIGERATING SYSTEMS

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Stainless Steel Single and Dual Circulation Kits

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

API Flanged Safety Relief Valves Series 526 CATALOG

Pressure reducing valves. Guide of applications

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

STABITHERM INSTALLATION & SERVICE BOOKLET

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

3/2-way Solenoid Valve, direct-acting, NC or NO

Thermostatic element RAVV for 2-way valves

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

AIR LINE VALVES AND GAUGES

CATALOGO TECNICO TECHNICAL CATALOGUE

MFP14, MFP14S and MFP14SS Automatic Pumps

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

How To Use A Flowmeter

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

FLANGED END BALL VALVE

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Type and Type Pneumatic Control Valves. Type (left) and Type (right) Mounting and Operating Instructions EB 8026 EN

Assisted lift operated 2/2-way solenoid valves Type EV250B

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

V47 Series Temperature Actuated Modulating Water Valves

Automatic control equipment for HVAC systems

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Zenith Solar thermal 4.5m pump station Installation manual

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Float and Thermostatic Traps Series H, C and X

MODEL LP 225LP2 225LP4 Safety Relief Valves

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Type 3353 Angle Seat Valve

1301 Series High-Pressure Regulators

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TYPE E Main Valve Sizes 3 /8 through 12

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

289 Series Spring-Loaded Relief Valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Your safety and the safety of others are very important.

Type 92S Pilot-Operated Steam Regulator

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

BRASS FITTINGS FOR THREADED PIPES

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

ALMATEC Series CX CX 10 CX 130

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

3/2-way Mini Solenoid Valve

Valves dimension of pressure (lbs) ANSI2500 ANSI1500 ANSI900 ANSI600 ANSI300 ANSI150. Inch. from 1/2 up to 6

RUBBER SLEEVE KNIFE GATE VALVE

SISTO-16TWA/HWA/DLU. Type Series Booklet

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

TECHNICAL DATA. Dry 122a. November 12, 2013

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

SELECTION, APPLICATION & MAINTENANCE

Self-operated Temperature Regulators Temperature Regulator Type 1u

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Compressor Service & Maintenance Manual

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Baumann Way Bronze or Stainless Steel Control Valve

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

4 Posiflow Proportional Solenoid Valves

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Blowdown vessels Meeting the requirements of HSE PM60

4/2-Way Pneumatic Solenoid Valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Thermostatic valve Type AVTA

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

Transcription:

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing and heating systems. Thanks to fully automated production processes, with 63 tooling machines and 25 assembly lines, we are able to produce 150,000 pieces per day. Our innate pursuit for innovation and observance of technical regulations in force is supported by the company certification ISO 9001: 2008. The company has always considered its focus on quality as the main tool to obtaining significant business results: today ITAP SpA is proud to offer products bearing the approval of numerous international certifying bodies. THE COMPANY

TEC Europress pressure reducing valve is a device which reduces and stabilizes the upstream pressure to an adjusted downstream pressure. When the entering pressure from the public mains is too high and variable, pressure reducing valve stabilizes the downstream pressure to the adjusted one. Possible variations of the upstream pressure do not influence the adjusted downstream pressure. This range of pressure reducing valves allows the operator to adjust the downstream pressure to a set figure. Pressure reducing valves are suitable for domestic water services, heating and air-conditioning plants, compressed air systems*. They can be used with water, compressed air and no-aggressive fluids. ITAP Pressure reducing valves comply with the requirements of Council Directive 97/23/EC (PED) and the CE marking is not requested according to art. 3 clause 3 of DL 25/02/2000 n. 93. (* In the type-testing according to PED Council Directive, it is necessary that pressure reducing valves were approved as a part of the installation). EUROPRESS

143 EUROPRESS PRESSURE REDUCING VALVE SIZE PRESSURE CODE PACKING 1/2 (DN 15) 25bar/362,5psi 1430012 1/34 3/4 (DN 20) 25bar/362,5psi 1430034 1/34 1 (DN 25) 25bar/362,5psi 1430100 1/18 1 1/4 (DN 32) 25bar/362,5psi 1430114 1/9 1 1/2 (DN 40) 25bar/362,5psi 1430112 1/9 2 (DN 50) 25bar/362,5psi 1430200 1/8 2 1/2 (DN 65) 25bar/362,5psi 1430212 1/6 3 (DN 80) 25bar/362,5psi 1430300 1/4 4 (DN 100) 25bar/362,5psi 1430400 1/3 TECHNICAL SPECIFICATIONS Compensated piston operation. Female/female threads. Body in nickel-plated brass. Minimum and maximum working temperatures: 0 C, 80 C. Maximum inlet pressure: 25bar. Outlet pressure can be adjusted: - 1/2-3/4-1 between 1 and 5,5 bar. - 1 1/4 through 4 between 1 and 6 bar. Factory preadjustment 3 bar. Outlet pressure gauge connection 1/4 on both sides. Threads ISO228 (equivalent to DIN EN ISO 228 and BS EN ISO 228). Available also with NPT thread in the sizes 2 1/2-3 - 4. PRESSURE REDUCING VALVES EUROPRESS OVERALL DIMENSIONS F F C B A 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 DN 15 20 25 32 40 50 65 80 100 A 77 85 91 118 126 142 147 179 188 B 125,5 125,5 159 218 225 250 270 290 330 C 40 40 59 69,5 126 87 88 97,5 140,5 F 12 12 13 18 18 20 20 22 23,5 Kg/cm 2 bar 25 25 25 25 25 25 25 25 25 LBS - psi 362,5 362,5 362,5 362,5 362,5 362,5 362,5 362,5 362,5

MATERIALS FROM 1/2 TO 1 TEC 14 13 12 11 10 9 8 7 15 2 3 4 1 6 5 POS. DESCRIPTION N. MATERIAL 1 Body 1 Nickel-plated brass CW617N 2 Seat 1 Stainless steel AISI 303 3 Bottom plug 1 Nickel-plated brass CW617N 4 O-Ring 1 EPDM 5 Shutter 1 Brass CW614N 6 Flat seat washer 1 EPDM 7 Stem 1 Brass CW614N 8 O-Ring 1 EPDM 9 O-Ring 1 EPDM 10 Diaphragm 1 Brass CW617N 11 Upper plug 1 Nickel-plated brass CW617N 12 Spring 1 EN 10270-1 DH 13 Nut 1 Nylon 14 Regulator 1 Nickel-plated brass CW617N 15 Cap 2 POM EUROPRESS

MATERIALS FROM 1 1/4 TO 4 17 16 15 14 13 12 10 11 9 18 8 4 3 5 7 6 1 2 POS. DESCRIPTION N. MATERIAL 1 Body 1 Nickel-plated brass CB753S PRESSURE REDUCING VALVES EUROPRESS CERTIFICATIONS 2 Bottom plug 1 Nickel-plated brass CW617N 3 O-Ring 1 NBR 4 Shutter 1 Brass CW614N 5 O-Ring 1 NBR 6 Stop washer 1 Brass CW614N 7 Flat seat washer 1 NBR 8 Seat 1 Stainless steel AISI 303 9 Stem 1 Stainless steel AISI 303 10 O-Ring 1 NBR 11 Stop ring 1 Brass CW625N 12 O-Ring 1 NBR 13 Diaphragm 1 Brass CW617N 14 Upper plug 1 Nickel-plated brass CW617N 15 Spring 1 EN 10270-1 SM/SH 16 Nut 1 Nylon 17 Regulator 1 Nickel-plated brass CW617N 18 Cap 2 POM DN15 - DN20 ACCORDING TO STANDARD EN 1567

143MM TEC EUROPRESS PRESSURE REDUCING VALVE, WITH UNION CONNECTIONS SIZE PRESSURE CODE PACKING 1/2 (DN 15) 25bar/362,5psi 1430012MM 1/34 3/4 (DN 20) 25bar/362,5psi 1430034MM 1/24 1 (DN 25) 25bar/362,5psi 1430100MM 1/18 1 1/4 (DN 32) 25bar/362,5psi 1430114MM 1/9 1 1/2 (DN 40) 25bar/362,5psi 1430112MM 1/9 2 (DN 50) 25bar/362,5psi 1430200MM 1/6 TECHNICAL SPECIFICATIONS Compensated piston operation. Union connections. Body in nickel-plated brass. Minimum and maximum working temperatures: 0 C, 80 C. Maximum inlet pressure: 25bar. Outlet pressure can be adjusted: - 1/2-3/4-1 between 1 and 5,5 bar. - 1 1/4 through 2 between 1 and 6 bar. Factory preadjustment 3 bar. Outlet pressure gauge connection 1/4 on both sides. Threads ISO228 (equivalent to DIN EN ISO 228 and BS EN ISO 228). OVERALL DIMENSIONS F F A 1/2 3/4 1 1 1/4 1 1/2 2 DN 15 20 25 32 40 50 A 123 135 156 177 188 213 B 125,5 125,5 159 218 225 250 C 40 40 59 69,5 126 87 F 12 12 14 16 16 17 Kg/cm 2 bar 25 25 25 25 25 25 LBS - psi 362,5 362,5 362,5 362,5 362,5 362,5 C B EUROPRESS

MATERIALS FROM 1/2 TO 1 14 12 13 11 8 10 7 9 17 18 2 6 4 1 5 16 3 15 PRESSURE REDUCING VALVES EUROPRESS POS. DESCRIPTION N. MATERIAL 1 Body 1 Nickel-plated brass CW617N 2 Seat 1 Stainless steel AISI 303 3 Bottom plug 1 Nickel-plated brass CW617N 4 O-Ring 1 EPDM 5 Shutter 1 Brass CW614N 6 Flat seat washer 1 EPDM 7 Stem 1 Brass CW614N 8 O-Ring 1 EPDM 9 O-Ring 1 EPDM 10 Diaphragm 1 Brass CW617N 11 Upper plug 1 Nickel-plated brass CW617N 12 Spring 1 EN 10270-1 DH 13 Nut 1 Nylon 14 Regulator 1 Nickel-plated brass CW617N 15 Cap 2 Nylon 16 Flat seat washer 2 Fiber 17 Nut 2 Nickel-plated brass CW617N 18 Fitting with flat seat 2 Nickel-plated brass CW617N

MATERIALS FROM 1 1/4 TO 2 17 16 TEC 15 14 19 13 12 9 1 11 10 21 20 4 3 6 8 7 5 2 18 CERTIFICATIONS POS. DESCRIPTION N. MATERIAL 1 Body 1 Nickel-plated brass CB753S 2 Bottom plug 1 Nickel-plated brass CW617N 3 O-Ring 1 NBR 4 Shutter 1 Brass CW614N 5 O-Ring 1 NBR 6 Stop washer 1 Brass CW614N 7 Flat seat washer 1 NBR 8 Seat 1 Stainless steel AISI 303 9 Stem 1 Stainless steel AISI 303 10 O-Ring 1 NBR 11 Stop ring 1 Brass CW625N 12 O-Ring 1 NBR 13 Diaphragm 1 Brass CW617N 14 Upper plug 1 Nickel-plated brass CW617N 15 Spring 1 EN 10270-1 SM/SH 16 Nut 1 Nylon 17 Regulator 1 Nickel-plated brass CW617N 18 Cap 2 Nylon 19 Flat seat washer 2 Fiber 20 Nut 2 Nickel-plated brass CW617N 21 Fitting with flat seat 2 Nickel-plated brass CW617N EUROPRESS

PRESSURE DROP CHART WITH WATER Pressure drop diagram includes the loss of pressure proportional to a specific flow rate. According to the requested flow rate, it is possible to measure the water system and the pressure reducing valve correctly (it would be better to have a flow speed between 1 m/s and 2 m/s in the piping). INSTANCE: In case of ½ pressure reducing valve with an adjusted downstream pressure of 3 bar and a flow rate of 35 l/min, the pressure drop diagram states a loss of pressure of 0.62 bar. It means that the pressure gauge installed on the outlet way of pressure reducing valve shows a figure of 2.38 bar (= 3 bar 0.62 bar). Here mentioned figures refer to: upstream pressure 8 bar, downstream pressure 3 bar. N.B. Figure about 4 are approximate. PRESSURE REDUCING VALVES EUROPRESS Pressure drop [Bar] 1.5 1 0.9 0.8 0.7 0.6 0.5 0.4 1/2 3/4 1 2 3 4 5 6 7 8 910 20 30 40 50 70 100 Flow rate [l/min] 1 1 1/4 1 1/2 200 2 2 1/2 3 300 400 500 DN 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Kv (m 3 /h) 3,6 4 6,6 9,6 10,2 18 22,8 27 39 700 4 1000 2000

MANIFACTURER INSTRUCTIONS Installation For the best use and duration of the system, it is necessary to comply with the following instructions on installation, with the national regulations and with relevant local requirements. - Place of installation has to be protected from frost and has to be easily inspectable - Install the pressure reducing valve on the private water system, immediately downstream of the water meter - It would be better to install shut-off valves upstream and downstream of the pressure reducing valve, to facilitate the maintenance operations - In order to protect pressure reducing valve from overpressure, install a check valve immediately downstream of the pressure reducing valve - The right scheme of installation is shown in Fig. 5.2 - In case of water heater downstream of the pressure reducing valve, install an expansion vessel between the valve and the water heater - In order to avoid cavitation and therefore excessive noiseness, it is strongly recommended that the ratio between maximum upstream pressure and regulating downstream pressure does not exceed the value of 2,5. - Pressure reducing valve is not a safety device. It would be better to install all the necessary safety relief valves. Please, duly note the downstream pressure of the reducing valve has not to be higher than the maximum working pressure of the devices installed in the private water system, in order to avoid possible damages or malfunctions. TEC Instruction on installation 1. Before installing the pressure reducing valve, open all the outlets to flush the system and expel any air left in piping 2. Install shut-off valves upstream and downstream to facilitate maintenance operations 3. For a right flow direction, use the arrow stamped on the body 4. ITAP pressure reducing valve can be installed in either vertical or horizontal piping. It can be installed also upside down 5. Art. 143 is equipped with a threaded connection suitable for a pressure gauge. It is possible to unscrew the plug made in order to install a pressure gauge in the size of 1/4. In such a position, the pressure gauge shows the downstream pressure of the reducing valve. 6. The whole range of ITAP pressure reducing valves are tested and adjusted with a downstream pressure of 3 bar. It is possible to change the downstream pressure by means of the adjusting device. 7. The final adjustment of the pressure reducing valve has to be carried out with a filled private water system and with all the outlets shut-off. The upstream pressure has to be at least 1 bar higher than the adjusted pressure. Adjustment of the pressure reducing valve to a downstream pressure different from the pre-adjusted one (3 bar): - Close the downstream shut-off valve - Unscrew the nylon nut (Fig. 4.1) - Adjustment is carried out by means of a tool or a screwdriver on the upper part of the device (Fig. 4.2); turn in clockwise way to increase the downstream pressure, turn in anticlockwise way to reduce the downstream pressure - Open the outlets in the private water system, in order to check the stability EUROPRESS

MANIFACTURER INSTRUCTIONS of the adjusted pressure - Adjust the downstream pressure with outlets totally shut-off and with water at room temperature only - Screw the nylon nut (Fig. 4.3) - Adjustment procedure is complete once the required pressure appears on the pressure gauge. FIG. 4.1 FIG. 4.2 FIG. 4.3 8. ITAP s.p.a. recommends the use of PTFE as a sealant in junctions between pressure reducing valves and water pipings. Troubleshooting Increase in pressure downstream on the pressure reducing valve with a water heater in-line. This problem is due to heating of the water, caused by the water heater. The pressure downstream increases, due to water expansion, as the pressure reducing valve is correctly closed. It is necessary to install an expansion vessel between the pressure reducing valve and the water heater to absorb the pressure increase (Fig. 5.1). PRESSURE REDUCING VALVES EUROPRESS The pressure reducing valve does not maintain the adjusted figure In most cases, this problem is due to the presence of impurities on the valve seat, causing blow-by and consequent increase in the downstream pressure. Install an Y-strainer upstream of the pressure reducing valve. Carry-out the maintenance of the Y-strainer. Flush the water system before installing the pressure reducing valve. Ball valve Flow direction Y strainer FIG. 5.1 Pressure reducing valve Check valve FIG. 5.2 Ball valve

NOTES TEC We reserve the right to make improvements and changes to the products described herein and to the relative technical data, at any time and without forewarning. EUROPRESS

ITAP S.p.A. Via Ruca 19 25065 Lumezzane Brescia (ITALIA) Tel 030 89270 Fax 030 8921990 www.itap.it-info@itap.it 05/2016