V.Varalakshmi 1, G. Shiva Kumar 2, R. Sunil Sarma 3

Similar documents
DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Technical Notes 3B - Brick Masonry Section Properties May 1993

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Detailing of Reinforcment in Concrete Structures

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Technical Assignment 2 TABLE OF CONTENTS

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

Optimum proportions for the design of suspension bridge

Chapter 8. Flexural Analysis of T-Beams

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

16. Beam-and-Slab Design

Design and Construction of Cantilevered Reinforced Concrete Structures

Seismic Risk Prioritization of RC Public Buildings

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

The International Journal Of Science & Technoledge (ISSN X)

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

Reinforced Concrete Design

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

CH. 2 LOADS ON BUILDINGS

Formwork for Concrete

Reinforced Concrete Design Project Five Story Office Building

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

Residential Deck Safety, Construction, and Repair

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Sisal Composite Ltd. Apparel 4 Ltd. JM Knit Ltd. Natun Para, Hemayetpur, Savar, Dhaka-1340 ( N, E)

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

EGYPTIAN CODES FOR DESIGN AND CONSTRUCTION OF BUILDINGS

6 RETROFITTING POST & PIER HOUSES

Hunter College school of Social Work Thesis Proposal

9.3 Two-way Slabs (Part I)

Analysis of a Tower Crane Accident

DISASTER RESISTANCE EARTHQUAKES AND STRUCTURES

Page & Turnbull imagining change in historic environments through design, research, and technology

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Numerical modelling of shear connection between concrete slab and sheeting deck

Chapter 2 Basis of design and materials

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

HOUSE BUILDING DIGEST

Seismic Isolation Retrofitting of Japanese Wooden Buildings

Structural Design Criteria & Design Loads on Delhi Metro Rail and Checking of Safety of Radial Joints in Tunnel Lining Segments

Number of Sides Required to Have a Handrail

Residential Decks. Planning and Development Services Department

L_All_Vocatinal_Ed_Construction. Sector: Construction. Sr. No Specialisation Page No 1 Construction and Building Technology 02.

Design Development Quality Management Phase Checklist Project Phase Checklist Series

Structural Analysis. EUROCODE 2 Background and Applications

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

INTRODUCTION TO BEAMS

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Certification: Building Plans Examiner. Exam ID: B3

Section 5A: Guide to Designing with AAC

FOOTING DESIGN EXAMPLE

POST AND FRAME STRUCTURES (Pole Barns)

HOW TO DESIGN CONCRETE STRUCTURES Foundations

How To Build A Luxury Apartment Complex In London

Design Manual to BS8110

[TECHNICAL REPORT I:]

Residential Prototype III. Multi-Story. The Multi-Story. Your connection to ideas + answers. Prepared by: AISC Steel Solutions Center

COMMONLY USED RESIDENTIAL BUILDING CODES

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Seismic performance evaluation of an existing school building in Turkey

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

Structural Audit of Buildings

Structural Design of Multi-story Residential Building for in Salem, India

Elevating Your House. Introduction CHAPTER 5

Requirements for Building Application Submission

Chapter 3 Pre-Installation, Foundations and Piers

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

Hardened Concrete. Lecture No. 14

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE

Design Example of a Six Storey Building

Rigid and Braced Frames

COMMONLY USED RESIDENTIAL BUILDING CODES

BUILDING PERMIT SPECIFICATIONS

Code of Practice for Structural Use of Concrete 2013

Chapter. Earthquake Damage: Types, Process, Categories

Methods for Seismic Retrofitting of Structures

Statics of Structural Supports

Index Series Prestressed Florida-I Beams (Rev. 07/12)

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Seismic design of beam-column joints in RC moment resisting frames Review of codes

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

How To Design A Post Tensioned Deck For A Building

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Transcription:

Analysis and Design of G+5 Residential Building V.Varalakshmi 1, G. Shiva Kumar 2, R. Sunil Sarma 3 1 Associate professor, Department of Civil Engineering, Marri Laxman Reddy Institute of Technology and Management, Dundigal, Hyderabad, India 2,3 Students, Department of Civil Engineering, Marri Laxman Reddy Institute of Technology and Management, Dundigal, Hyderabad, India ABSTRACT: The design process of structural planning and design requires not only imagination and conceptual thinking but also sound knowledge of science of structural engineering besides the knowledge of practical aspects, such as recent design codes, bye laws, backed up by ample experience, intuition and judgment. The purpose of standards is to ensure and enhance the safety, keeping careful balance between economy and safety. In the present study G+5 building at Kukatpally, Hyderabad, India is designed (Slabs, Beams, Columns and Footings) using Auto CAD software. In order to design them, it is important to first obtain the plan of the particular building that is, positioning of the particular rooms (Drawing room, bed room, kitchen toilet etc.) such that they serve their respective purpose and also suiting to the requirement and comfort of the inhabitants. Thereby depending on the suitability; plan layout of beams and the position of columns are fixed. Thereafter, the loads are calculated namely the dead loads, which depend on the unit weight of the materials used (concrete, brick) and the live loads, which according to the code IS:456-2000 and HYSD BARS FE415 as per IS:1786-1985. Safe bearing capacity of soil is adopted as 350KN/M 2 at a depth of 6ft and same soil should extent 1.5 times the width of footing below the base of footing. Footings are designed based on the safe bearing capacity of soil. For designing of columns and beams, it is necessary to know the moments they are subjected to. For this purpose, frame analysis is done by limit state method. Designing of slabs depends upon whether it is a one - way or a two way slab, the end conditions and the loading. From the slabs, the loads are transferred to the beam. Thereafter, the loads (mainly shear) from the beams are taken by the columns. Finally, the sections must be checked for all the four components with regard to strength and serviceability. Keywords: Beams, columns, footings, slabs, Structural Designing. I. INTRODUCTION: Buildings come in a wide amount of shapes and functions, and have been adapted throughout history for a wide number of factors, from building materials available, to weather conditions, to land prices, ground conditions, specific uses and aesthetic reasons. A Multi-Stored is a building that has multiple floors above ground in the building. Multi-storey buildings aim to increase the floor area of the building without increasing the area of the land the building is built on, hence saving land and, in most cases, money (depending on material used and land prices in the area). The design process of multi-stored building requires not only imagination and conceptual thinking but also sound knowledge of science of structural engineering besides the knowledge of practical aspects, such as recent design codes, bye laws, backed up by ample experience, intuition and judgment. The purpose of standards is to ensure and enhance the safety, keeping careful balance between economy and safety (Divya kamath et al., 2012). In the present study G+5 building at Kukatpally, Hyderabad, India is designed (Slabs, Beams, Columns and Footings) using Auto CAD software. II. GEOMETRY OF BUILDING: The building is regular in plan and in elevation having storey height of H st = 3.0m where all storey s are of the same height. The building consist of five bays along the two horizontal directions of bay length L b = 5.0m with the same bay length throughout the plan. The building consist of square columns, beams of width 0.3m and slab thickness of 150mm. the size of column is constant throughout all storey and the size of beam is constant throughout each storey. The perimeter beams and exterior columns have half the elastic rigidity of interior ones and corner columns have one quarter of elastic rigidity of interior ones. International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 73 Page

III. DESIGNING OF SLABS: In the present paper two types of slabs are designed namely roof slab and floor slab. Roof slab is a continuous slab on the top of the building which is also known as terrace. Generally terrace has less live load and it is empty in most of the time except at some occasions. Hence all the roof slabs are designed as one way slab for the easy arrangement of the reinforcement and ease of work. Therefore in designing the roof slab dead loads (i.e., due to water proofing=2.5kn/m 2, self weight of the slab= 1 1 required depth 25) and live loads (roof=1.5kn/m 2 ) are considered. Roof S2 and S5 are the same dimensions but different in end conditions because, for roof slab main steel is provided along the short span only and the load is transferred to two opposite supports only. The steel along the long span just acts as distribution steel and is not designed for transferring the load but to distribute the load and to resist shrinkage and temperature stresses. For floor slab live load is more when compared to the roof slab. Therefore in designing of floor slab dead loads (i.e., due to floor finish = 1KN/m2, sanitary blocks including filling = 2.5KN/m2 and self weight of the slab = 1 1 required depth 25) and Live loads (i.e., Sanitary blocks public = 3KN/m 2, corridor = 5 KN/m 2, partition wall = 1.5KN/m 2 ) are considered. The designing is followed IS875-PART1 and 2 codes. The details of reinforcement provided in slabs are given table.1 Table.1 Details of reinforcement provided in slabs for G+5 Building S.No Short Span Steel Long Span Steel Slab Thickness Remarks S1 8mm ØR.T.S @7"c/c 8mm Ø R.T.S @ 7" c/c S2 8mm ØR.T.S @6"c/c 8mm Ø R.T.S @ 8" c/c 4 1 2 One-Way S3 8mm ØR.T.S @7"c/c 8mm Ø R.T.S @ 7" c/c S4 8mm ØR.T.S @6"c/c 8mm Ø R.T.S @ 7" c/c S5 8mm ØR.T.S @5"c/c 8mm Ø R.T.S @ 8" c/c 4 1 2 One-Way IV. DESIGNING OF BEAMS: A reinforced concrete beam should be able to resist tensile compressive and shear stresses induced in it by the loads on the beam. Concrete is fairly strong in compression but very weak in the low tensile strength. Plan concrete beams are thus limited in carrying capacity by the low tensile strength. Steel is very strong in tension. Thus the weakness of concrete is overcome by the provision of reinforcing steel in the tension zone around the concrete to make a reinforced concrete beam. The beam is analyzed first in order to calculate the internal actions such as bending Moment and shear force. A simplified substitute frame analysis can be used for determine the bending moments and shearing forces at any floor of roof level due to gravity loads. In order to analyse the frame it is need to calculate the loads (i.e., Uniformly distributed load including slab on the right side, masonary wall load self weight, total working load and point loads ). The designing of the beam mainly consist of fixing the breadth and depth of the beam and arriving at the area of steel and the diameters of bars to be used. The breadth of the beam is generally kept equal to the thickness of the wall to avoid offset inside the room. It shall also not exceed the width of the column for effective transfer of the load from beam to column. The depth of the beam is taken by L/10 to L/6. Therefore in the present design all beams are in rectangular shape having the breadth and depth of the beam is 230mm and 450mm respectively. The floor beams arrangement is shown in Fig.1 Fig.1 Schedule of typical floor beams V. DESIGNING OF COLUMNS International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 74 Page

A column in general may be defined as a member carrying direct axial load which causes compressive stresses of such magnitude that these stresses largely control its design. The loads and moments in the three columns in a frame are different. Each of the column is required to be designed separately. However when entire building is to be designed, there will be a number of other columns along with each of the above columns to form a group. All the columns are subjected to axial loads (P u ) and uniaxial bending moment (M u ). the column section shall be designed just above and just below the beam column joint and larger of the two reinforcements shall be adopted. This is similar to what is done for design of continuous beam reinforcement at the support. The design moment is followed IS456:2000 code. The schedule of columns are given in Table.2 Table.2 Column schedule Coloum Type Mix Size Main Steel column number's C1 M-20 9" 18" 8-#16 4 C2 M-20 9" 18" 10-#16 9 C3 M-20 9" 21" 10-#16 11 C4 M-20 9" 21" 4-#20+6-#16 7 C5 M-20 9" 24" 6-#20 4-#16 22 C6 M-20 12" 24" 6-#20 4-#16 11 C7 M-20 12" 24" 12-#20 17 C8 M-20 12" 24" 6-#25 6-#20 13 C9 M-20 12" 30" 6-#25 6-#20 6 C10 M-20 12" 30" 12-#25 4 C12 M-20 12" 36" 14-#25 1 VI. DESIGNING OF FOUNDATION: Foundation design involves a soil study to establish the most appropriate type of foundation and a structural design to determine footing dimensions and required amount of reinforcement. Because compressive strength of the soil is generally much weaker than that of the concrete, the contact area between the soil and the footing is much larger than that of the columns and walls (Soil and foundation handbook, 2004). The present study indicates that the site is located in granite rock which is suitable for strong foundation. To determine the bearing capacity of soil, samples of soil are tested in the laboratory and found that the Safe bearing capacity of soil is 350KN/M 2 at a depth of 6ft and same soil should extent 1.5 times the width of footing below the base of footing. Depending on the bearing capacity of soil and designing of structure isolated square footings and combined footing of M-20 mix and reinforced with HYSD bars of Fe-415 is designed as per IS :786-1985. Therefore the footing is isolated rectangular sloped footing with pedestal. The slope is provided to decrease the concrete in the construction which results into economic construction. A pedestal is used to carry the loads from metal columns through the floor and soil to the footing when the footing is at some depth in the ground. And an isolated column footing transfers the loads from a single column to the supporting soil. The footing is designed for flexure, punching or two-way shear, and flexural or one-way shear. The allowable soil bearing pressure determines the size of the footing, and the punching shear governs the depth of the footing. The schedule of footings in the site are listed in Table.3 and general footing plan and pedestal footing plan is shown in Fig.2 Footing type Table.3. Design Considerations of Footing Mix Size Reinforcement Footing Pedestal depth size F1 M-20 5'0" 5'0" F2 M-20 5'3" 5'3" F3 M-20 5'6" 5'6" Pedestal height 18" _ 21" _ Pedestal reinforcement 21" 2'0" 2'0" 24" 8 nos-#12 F4 M-20 5'9" 5'9" 21" 2'0" 2"0" 24" 8 nos-#12 International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 75 Page

F5 M-20 6'3" 6'3" F6 M-20 6'9" 6'9" F7 M-20 7'0" 7'0" F8 M-20 7'6" 7'6" F9 M-20 8'0" 8'0" F10 M-20 8'3" 8'3" F12 M-20 9'0" 9'0" 12mm Ø R.T.S 4" 24" 2'6" 2'6" 24" 8 nos-#12 24" 2'6" 2'6" 24" 8 nos-#12 27" 2'6" 2'6" 24" 8 nos-#12 30" 2'6" 2'6" 24" 8 nos-#12 30" 3'0" 3'0" 24" 12nos-#12 33" 3'0" 3'0" 24" 12 nos-#12 36" 3'3" 3'3" 24" 12 nos-#12 Fig.1 Typical footing plan of G+5 building VII. DESIGN OF STAIR CASE: Stairs consist of steps arranged in a series for purpose of giving access to different floors of a building. The location of stairs requires good and careful consideration. In the present design Dog-legged staircase is designed. The dimensions of Breadth, length and Height are 2820mm, 60000mm and 3350mm respectively. Assume rise = 150mm Tread = 300mm and angle (secθ)= (150) 2 +(300) 2 /300 = 1.12 Therefore Number of risers = 3350/150 22. So for flight-1:11 and for flight-2:11 Going 11*treads = 3300mm Total width of landings = 6000-3300 = 2700mm Therefore width of landing at each end = 1350mm For stair case provide Ф 8mm @ 200 mm c/c. the schematic layout of stair case is shown in Fig.3 Fig.3 Schematic layout of stairs VIII. DUCTILE DETAILING After designing the frame column-beam, shear walls and foundation by limitstate theory as per IS456:2000, all details of longitudinal steel, overlaps, shear capacities, confining reinforcement requirements, stirrups and ties etc. is worked out using the provisions of IS13920:1993 IX. CONCLUSION International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 76 Page

In the present study G+5 building at Kukatpally, Hyderabad, India is designed (Slabs, Beams, Columns and Footings) using Auto CAD software. The loads are calculated namely the dead loads which depend on the unit weight of the materials used (concrete, brick) and the live loads using the code IS:456-2000 and HYSD BARS FE415 as per IS:1786-1985.The safety of G+5 reinforced concrete building will depend upon the initial architectural and structural configuration of the total building, the quality of the structural analysis, design and reinforcement detailing of the building frame to achieve stability of elements and their ductile performance. Proper quality of construction and stability of the infill walls and partitions are additional safety requirements of the structure as a whole. The detailed plan of the building is given in Fig.4. Fig.4 Typical floor working plan REFERENCES [1] Divya kmath, K.Vandana Reddy, Analysis and design of reinforced concrete structures-a G+5 building model, miniproject report, Gokaraju Rangaraju Institue of Engineering and Technology, Hyderbad, India, 2012 [2] Soil and Foundation hand book, State Materials Office Gainesville, Florida, 2004 [3] IS: 875 (Part 1), Part 1: Dead Loads--Unit Weights of Building Materials (Second revision), Code of Practice for Design Loads (Other Than Earthquake) For Buildings and Structures, Bureau of Indian Standards, New Delhi, 2000. [4] IS: 875 (Part 2), Part 2: imposed loads (Second revision), Code of Practice for Design Loads (Other Than Earthquake) For Buildings and Structures, Bureau of Indian Standards, New Delhi, 1987. [5] IS: 13920, Ductile detailing of reinforced concrete structures subjected to seismic forces, Bureau of Indian Standards, New Delhi, 1987. [6] IS: 456 ( Fourth Revision ), Plain And Reinforced Concrete - Indian Standard code of practice, Bureau of Indian Standards, New Delhi, 2000. International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 77 Page