4283 Dissolved Oxygen

Similar documents
OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Hand-held thermometer Model CTH7000

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Temperature & Humidity SMS Alert Controller

DissolvedOxygenMonitor

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

How To Use A Ds340 (Dsp)

Galvanic Parts Per Million Dissolved Oxygen Systems

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Test equipment for temperature and its reduction

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

API Marine. BMS Presentation. Ballast Measurement Systems

Electronic Control Devices The European Product Catalogue 2007

DC Electronic Loads 8500 series

NC-12 Modbus Application

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Multifunction devices

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

USB-500/600 Series Low-Cost Data Loggers and Accessories

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

2.24. Pump Controller 704. Data Sheet

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Why a torque measuring system?

Electronic Flow Switches

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

O C M III. Open Channel Flow Monitor

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital inductive conductivity transmitter

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Turbine Flow Sensor Series VTR

Electronic Control Devices The European Product Catalogue 2007

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

USB-500/600 Series Low-Cost Data Loggers and Accessories

Sanitary Type Electronic Flow Switches

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

SMS GSM Alarm Messenger

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Measurement by Ion Selective Electrodes

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

OxyGuard. Dissolved Oxygen Probe

DISSOLVED OXYGEN METER Model : DO-5509

USB-500 Series Low-Cost Data Loggers and Accessories

Centro-Matic Automatic Lubrication Systems System Controls

T0118 T2118 T3118. Instruction Manual

Dissolved Oxygen Sensors

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Interface Level And Point Level Analyzers & Sensors

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Inwall Room Temperature Unit

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Electromagnetic Flow Meter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Read A Pipe From A Sensor

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Wahl C50 Calibrator FEATURES

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Chlorophyll Content Meter. CCM-200 plus

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Electronic Pressure Switch EDS 300

High Power Programmable DC Power Supplies PVS Series

Section TELEPHONE AUTOMATIC DIALER SYSTEM

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

4-Channel Thermometer / Datalogger

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

OZW30. Central Unit SYNERGYR

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

PART 1 - INTRODUCTION...

Current Monitoring Kit QUICK START GUIDE

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

RECON-4 Portable Multi-gas Detector Software Manual

Conductivity and TDS Meters

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Transcription:

4283 Dissolved Oxygen Measuring range Dissolved oxygen 0 to 20.0 ppm or mg/l - 0 to 200% SAT Resolution 0.1 ppm or mg/l - 1% SAT Dual parameter versions available 4238-83 [ph/redox - Dissolved oxygen] 4262-83 [Turbidity - Dissolved oxygen] 4263-83 [Suspended solids - Dissolved oxygen] 4283-83 [Dissolved oxygen - Dissolved oxygen] with S423/C/OPT optical sensor only S423/OXYSENS Main measuring range The oxygen contained in the liquids is measured using the so-called Clark cell system. These cells generate a current proportional to the partial pressure of the oxygen, which can be detected using a suitable signal converter. In order to prevent interference during measuring, the Clark cell is protected by a gas-permeable membrane. The membranes typically used are made from PTFE but, as this material is mechanically fragile, frequent changing is often necessary, along with the related demanding operations (interruption of measurement, replacement of the electrolyte, regeneration of the electrodes). The S423 solves this problem by using a membrane made from OPTIFLOW. Manufactured as a sheet around a layer of steel, it is very stable mechanically and very resistant to chemically aggressive environments as well as high pressure. Thanks to the special construction of the measuring electrodes, this system also makes the sensor totally maintenance free. Maintenance OXYSENS sensors are maintenance-free, and do not require the replacement of the membrane, electrolyte or regeneration of the electrodes, to measure the oxygen in aqueous samples. Typical applications include water treatment plants and the fish industry. Technical data Electrode material Electrolyte Membrane Temperature sensor Polarisation current Sensitivity Stabilisation time Silver-platinum combination Alkaline solution OPTIFLOW NTC 22 kohm -670 +/- 50 mv Operating temperature 0... 60 C Storage temperature Pressure Outer diameter Connection 40... 80 na at 25 C in air typical 15 min., max. 1 h -10... 60 C, with water inside the protective cap 0... 4 bar during insertion; max. 0.5 bar in total during submersion 12 mm PG 13.5 threaded Construction materials Regeneration Response time t 98% Temperature response Measuring liquid speed 1.4435 stainless steel, PEEK, silicone, NBR not required max. 60 s at 25 C, from air to nitrogen approx. 3.1%/K min. 0.03 m/s Influence of flow rate < 5% at 25 C Oxygen consumption approx. 20 ng/h in air at 25 C Residual current Zero drift Sensitivity drift < 0.5% current in air < 0.5% current in air every 2 months at 25 C or in water in stable conditions < 10% every 2 months at 25 C in water in stable conditions

S432/C/OPT Oxygen and temperature sensor with OPTICAL technology 4Optical technology: no membrane or electrolyte 4No signal drift: no calibration 4Digital output: Modbus RS-485 4Sturdy stainless steel structure Fields of application Biological purification systems (aeration, nitrification/denitrification tanks etc.) Industrial water treatment plants Monitoring surface water Aquaculture Water conditioning Optical technology The S432/C/OPT sensor measures oxygen with a built-in temperature probe. The measuring technique is based on the optical principle: a diode emits a light blue towards a support on which a fluorescent substrate is applied. The substrate initially reacts by emitting a red light (luminescence), then returns to its initial state. The intensity of the red light produced and the rate of return to the initial state are related to the concentration of oxygen present. This innovative method ensures reliable, accurate measurements with no drift over time, therefore system calibration is no longer necessary. No maintenance is required except for replacing the luminescent support about every two years. The system does not consume oxygen, therefore it is suitable for the most varied fields of application, including those in which the measuring liquid is almost stationary. Digital technology Built-in pre-amplification circuit and digital signal processing. The S432/C/OPT sensor saves the calibration data for optimal data management. The output signal is provided on the RS 485 serial port. Physical characteristics Compact, sturdy and lightweight, the stainless steel body enables fixed or portable applications. Technical data Measuring principle Optical by means of luminescence Measuring ranges 0,00 20,00ppm / 0-200 % Sat 0 50 C Resolution 0,01 ppm Precision +/-0,1ppm / +/-1 % Temperature compensation via NTC Response time 90% of the actual value in less than 60 seconds Liquid stirring speed Not required Digital interface RS-485 Modbus Maximum refresh time < 1 second Membrane Electrodes Electrolyte Dimensions Weight Materials in contact with the liquid Maximum operating pressure Protection rating Interchangeable sensor cap Typical duration 2 years. No electrode No electrolyte Diameter: 34 mm Length: 180 mm Fitting: 3/4" male 850 g (sensor + 10 m cable) Stainless steel 316L/PVC 5 bar IP68 Storage temperature -10.. + 60 C

42 series The 42 series developed by Chemitec is dedicated to the water treatment and industry sectors, and enables the following parameters to be measured: 4pH/REDOX 4Dissolved oxygen 4Conductivity 4Turbidity 4Suspended solids 4Chlorine 4Chlorine dioxide 4Ozone Process control device Display 4Simultaneous measurement (numerical and bar graph) and temperature values. 4Scrolling output values. 4Graphic icons for: status of digital outputs, washing cycle, data recording, alarms. 4Possibility to display the measurement only in large format. Data recording 44-bit internal flash memory (about 16,000 records). 4Recording interval: 1 to 99 min. 4Type: Circular (F.I.F.O.) or filling. 4Ability to view the logged data in table or graphic form, with indication of the maximum, minimum and average values in the selected periods. Wall-mounted version with IP66 protection rating (144 x 144 x 120 mm) PID control 4P - PI - PID functions activated on the analogue or digital output. 4Proportional range: 0 to 500%. 4Integral time: 0:00 to 5:00 min. 4Derivative time: 0:00 to 5:00 min. Panel-mounted version (144 x 144 x 100 mm) 2 analogue outputs 4Output 1 programmable for measurement. 4Output 2 programmable for measurement / temperature / PID control. 4 The limits of the outputs are freely programmable within the measuring range. 4 digital outputs 4ON/OFF set point: Programming the operating range (hysteresis/direction) and start/stop time 000 to 999 seconds. 4PID control: Pulses, frequency or PWM (2 set points).

Alarm 4Programmable for: tool faults, minimum, maximum, set point delay, stay time (live check). 4Delay time: 00:00 to 59:59 mm:ss with minimum interval of 15 sec. 4Stay time 00:00 to 99:59 hh:mm 4Set point deactivation (in case of alarm): Enabling/Disabling. Washing electrodes 4Programming the interval (minimum 15 min) and the duration. 4During washing, all the analogue and digital outputs are frozen. Digital input 4To disable the doses. RS485 serial port 4For set-up and remote real time acquisition or for downloading data (using dedicated software). 4 MODBUS RTU communication protocol. USB port 4USB for direct download on PEN DRIVE (optional). Manual controls 4Possibility to simulate the analogue and digital outputs from the keypad. Temperature compensation 4Using PT100 sensor with 3 or 4 wires, or PT 1000. Electrical connections Measure Temperature Vac/dc 1 2 3 8 Serial Port RS485 1st Channel Serial Port RS485 2nd Channel USB port 1 2 3 4 Temperature 15-30 VAC-VDC input Digital input Digital Power Supply 100 240 Vac 4 5 CPU 9 Output 4 20 ma 1st Channel Output 4 20 ma 2nd Channel 5 6 7 Universal power supply 100 240 VAC Ground Keypad and graphic display Ground 6 Relay 1 Setpoint Output Keypad Graphic display 7 10 Relay 2 Setpoint Relay Alarm/Temp1 Relay Alarm/Temp2 8 9 RS485 serial port and USB Current outputs 10 Digital outputs Set Point 1 Set Point 2 Alarm /Temp 1 Washing / Temp 2

Simple and intuitive software 4Interactive, easy to read interface 4Main menu with graphic icons Display of stored data in graphical form, even during RUN TIME measurement MODBUS RTU serial interface for: 4Communication of data in real time 4Downloading the data stored on PC via SW or directly on the removable USB pen drive (optional)

Dimensioni Wall-mounted version with IP66 protection rating 144 122,5 25.5 32 80 144 Ø6.5 16.25 68 4 x pg9 38 38 18 30 2 x pg11 35 35 Panel-mounted version 144 x 144 Panel-mounted version 96 x 96 92 92 88 96 108 123 7 Paab Tekno Trading AB - Tingvallastrand 12, 661 40 Säffle, Sweden Tel: +46 533 150 60 - Fax +46 533 169 31 - info@paab.com - www.paab.com