Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines



Similar documents
The Interaction of Contactors with PLCs

Nothing s BetterThan the Original MODAN Power Distribution Systems


CONFIGURABLE SAFETY RELAYS

Easy Multifunctional Safe

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CONFIGURABLE SAFETY RELAYS

Safety automation solutions

SAFETY MANUAL SIL Switch Amplifier

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Safety Relays ESM/ESM-F

E-STOP relays, safety gate monitors

SAFETY MANUAL SIL RELAY MODULE

Safety Manual BT50(T) Safety relay / Expansion relay

Number 1 in efficiency

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Data Sheet. Electro-mechanical counters Hengstler 800 series

CQM1-SF200/CS1W-SF200

Products and solutions for lifting systems

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Application Technique. Safety Function: Magnetic Door Switch Monitoring

SMS 4 / SMS 5 safety mat Product information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Safety Function: Door Monitoring

Insulation resistance

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Arc Terminator Active Arc-Resistant Switchgear

Introduction to Safety

Preventa Machine Safety Products

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

Certificate of Compliance

Increased power protection with parallel UPS configurations

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Presentation Safety Legislation and Standards

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Export relevant information on supply distribution networks in North America

PowerChain Management solutions. PowerChain Management Solutions for Data Centers

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Digital Expansion Modules Specifications

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

DC Combiner box and AC solutions. Leadership in circuit protection

Type: DILM9 10(24VDC) Article No.:

Understanding Emergency Power Off (EPO)

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Circuit Breakers. Next Generation of Protection Capabilities

SAFETY MANUAL SIL SMART Transmitter Power Supply

Products and solutions for machine builders (OEM) 100% electricity

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Safety technique. Emergency stop module BO 5988 safemaster

ATC-300 Automatic Transfer Switch Controller

Products and solutions for pumping, irrigation and piping

Unified requirements for systems with voltages above 1 kv up to 15 kv

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Contact expander modules

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Machineontwerp volgens IEC 62061

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Type: DILM32 10(24V50HZ) Article No.:

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

3BASIC RELAY INSTRUCTIONS

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PABIAC Safety-related Control Systems Workshop

ADM1TE 5/30A DIN rail single phase two wire energy meter

Bypass transfer switch mechanisms

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.


E-STOP relays, safety gate monitors

Power Supplies 3. SDN-P DIN Rail Series

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Contact expansion modules

Inductive sensor NI10-M18-Y1X-H1141

Addendum to the Operating Instructions

Manual Motor Starter MS 116 up to 16 A Technical Data

GAM900/GAM900S. Acceleration precisely measured and safely monitored

HERZ-Thermal Actuators

Phase Modular Finally the benefits of Modular ups are for all

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Vilter motor starter solutions The NEW industry standard in motor starter packages

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

ELECTRICAL DOCUMENTATION ACCORDING TO STANDARDS

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

Model SPDT Relays

Memcom Emergency Telephone

E-STOP relays, safety gate monitors

CompactLogix Power Supplies Specifications

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

NX safety stand-alone

Safe Machinery Handbook

Transcription:

www.eaton.com/moellerproducts Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines Technical Paper Dipl.-Ing. Wolfgang Nitschky

The way to safe machines During the engineering design phase of a machine, every design engineer in addition to considering the functional aspects of the machine is confronted eventually with the issue of safety features, and is posed with the following question: How dangerous is the machine that they are designing? The potential dangers posed by the machine can be identified by a risk assessment. A portion of the danger can be suppressed by mechanical modifications or extensions (no sharp edges, bulkheads in front of moving parts, etc.). If an electrical control is engineered, safety tasks are shifted to the control. Typical safety tasks are the Emergency- Stop or monitoring of safety doors, contact mats or photoelectric barriers. The question of the reliability of the control during a malfunction should be considered in order to delegate the control of safety-relevant tasks to the control. The EN 954-1 The European standard EN 954-1 can easily claim to be simple to apply. Based on the simplicity of its fundamental design, the standard can be easily integrated and applied in the field of mechanical engineering. The classification in specific cases is not always easy, but the basic steps to be applied remain transparent in all cases. Using the tree structure (Figure 1) it is possible to appraise what can happen if the control fails. First of all the seriousness of the injury is assessed, followed by the time spent in the danger area and finally the perceptibility of the danger. The assessment results in the safety categories to which the control must comply. The safety categories are a measure of the reliability of the control during a malfunction. The fundamental difference between controls of safety category 1 or 2 to controls of categories 3 or 4 is that the controls in safety categories 1 and 2 may lose their safety function during a fault scenario. Controls of safety category 3 or 4 must maintain their safety function even in a fault scenario. Contactor control circuits conform to EN 954-1 If the electrical circuits for control of motors are now examined, the motors are switched by contactors. A typical contactor fault is welding of the contactor contacts. If the control voltage on the contactor coil is removed by an Emergency-Stop and there is a fault involving welded contactor contacts, further measures for maintaining the safety function in controls of safety category 3 or 4 must be provided. Generally, a connection of two contactors in series (Figure 2) is provided. With the rare exception that both contactors have not welded at the same time, the safety function is maintained as the second contactor will bring the drive which is the source of danger to a standstill. This expensive solution, which requires significantly more space in the control panel and additional time and expense for manufacturing the main wiring harness, is not always acceptable in the engineering design. This is where Eaton Moeller uses the CMD Contactor Monitoring Device. Not a second, expen- B 1 2 3 4 Category in accordance with EN 954-1 Risk graph S1 P1 Starting point for risk assessment S2 F1 P2 Category selection P1 F2 P2 S Severity of injury S1 Slight injury S2 Serious irreversible injury to one or several persons, or death F Frequency and time of exposure to the hazard F1 Rarely to often and/or a short duration F2 Frequent to continuous and/ or a long duration Preferred category for reference points Possible categories which require additional measures, e.g. over-dimensioning Over-dimensioned categories for the risk concerned Figure 1: Risk assessment graph according to EN 954-1 P Possibility of avoiding hazards P1 possible under specific conditions P2 Scarcely possible 2

Figure 2: Redundant power section sive and large contactor to maintain the safety function, but rather a small attractively priced relay. This continuously compares the specified state of the contactor based on the control voltage with the actual state which is signalled with the assistance of an auxiliary contact. In a fault scenario, the CMD switches the upstream contactor or switch-disconnector off using the undervoltage coil. Enhancements of the EN 954-1 in the EN ISO 13849 The simple handling of the EN 954-1 described at the outset has the disadvantage that it fails to make any mention of the reliability of the control in the scheduled service life. This circumstance has lead to the EN 954-1 only being valid for a transitional period. The successor standard EN ISO 13849, has been expanded in some aspects and makes statements regarding the occurrence of malfunctions. PL Performance Level The assessment of the consequences of a control failure using a tree structure no longer results directly in a safety category, but rather in a Performance Level in accordance with the EN ISO 13489. This can result in PLs ranging from a to e (Figure 3). The PL reflects the level of danger that exists due to the failure of a control. On machines featuring a control of PL a, there is only a low level of danger, whereas machines with a control categorised as PL e are categorised as very dangerous. The actual Performance Level that a control complies with no longer depends solely on the design of the control. Additionally, qualitative declarations regarding the service life and fault detection must also be considered. MTTF Mean time to failure The MTBF time (mean time between failure) is a measure of the reliability of a component or a control which has been in use for a long time with electronic components. As the electromechanical components of an assembly no longer function after the first fault, the MTTF time (mean time to failure) is taken into consideration here. It is a measure of how long the component or control will function reliably. As only the faults, which can cause dangerous failures need to be examined from the safety technology perspective, the MTTF d (Mean time to failure dangerous) is considered for assessment of the Performance Level. 3 years <= MTTF d < 10 years r low 10 years <= MTTF d < 30 years r medium 30 years <= MTTF d < 100 years r high DC Diagnostic Coverage The Diagnostic Coverage enables a quantitative statement with regard to detected faults. This involves the assumption principle that a control that detects a large number of faults is more reliable than a control that hardly detects any faults. DC < 60% r no error detection 60% DC < 90% r low error detection 90% DC < 99% r medium error detection 99% DC r high error detection Risk parameters F2 Frequent up to continuous exposure to S Severity of the injury the hazardous condition S1 Slight (generally a reversible injury) Legende P Possibility of avoiding the hazard or lim- S2 Severe (irreversible injury including 1 Starting point to the assessment of the iting the damage death) risk reduction P1 Possible under certain conditions risk reduction L Low contribution to F Frequency and/or exposure time to the hazardous condition P2 Scarcely possible H High contribution to risk reduction F1 Seldom up to quite PL often and/or the r Required Performance Level exposure time is brief Source: DIN EN ISO 13849-1 Figure 3: Risk assessment graph according to EN ISO 13489 DC avg none DC avg none Legende PL Performance Level 1 MTTF d every channel = low 2 MTTF d every channel = medium 3 MTTF d every channel = high Figure 4: Performance Level DC avg low DC avg medium DC avg low DC avg medium DC avg High Source: DIN EN ISO 13849-1 3

L1 L1 L01 L01 L2 L2 -F1 L3 L3 -Q1 -Q11 L1 L2 L3 1.13 I > I > I > T1 T2 T3 1 3 5 2 4 6 a -Q1 -S1 1.14 -K 21 22 -S2 13 14 -Q11 13 14 -Q11 21 22 -Q11 33 34 -S3 21 22 TEST b 13 14 PE -X1 U V W PE PE -Q11 A1 A2 -F2 CMD A1 A2 L S21 S22 S13 S14 S31 S32 -Q1 D1 D2 U < D2 -M1 M 3 L02 1 2 3 4 5 6 13 14 21 22 33 34 L02 Figure 5: Circuit diagram of direct-on-line starter with redundant shutdown Common cause failure In order to avoid a failure burst measures must be undertaken to avoid common cause failures. For this purpose, a range of measures is provided by the standard to assist the users. Interaction between PL, DC, MTTF d The Performance Level to which the control complies can be read off of a bar chart (Figure 4). Operating principle of the CMD Figure 6: High level of reliability of the contactor monitoring relay The CMD relay has the task of monitoring the high-power contacts of the motor contactor for welding. For this purpose, the control voltage of the contactor coil 4

module. Even in the standard auxiliary contact NHI2-11S-PKZ2, all the contact modules are positively-drive with respect to each other. CMD variants The supply voltage of the CMD must be identical to the control voltage of the contactor to be monitored. The CMD is available for different control voltage variants in order to cover the largest possible range of applications: Figure 7: Contactor auxiliary contact with mirror contact is applied as the specified on the CMD. On the other side the actual state of the contactor is signalled via a reliable auxiliary N/C contact. The CMD compares the nominal and actual state. The undervoltage coil of the upstream circuit-breaker or switch-disconnector is supplied via a relay output. In the event of a fault the circuit-breaker / switch-disconnector is switched off via the undervoltage coil and the motor voltage source is switched off (Figure 5). The CMD in combination with the circuitbreaker / switch-disconnector complies with the demand for a redundant shutdown. Irrespective of the welded contactor fault, the control continues to maintain its safety function (Figure 6). has also defined a solution for this situation. Mutual monitoring of auxiliary N/O contacts and auxiliary N/C contacts is possible with positively-driven contacts, as they may never by closed simultaneously. This is used for monitoring of mirror contacts. An additional auxiliary N/O contact which must be positively-driven to the mirror contact, is additionally monitored by the CMD. Welding of the auxiliary contact is thus detected which forces the drive to a standstill. In the Eaton Moeller contactor series, all auxiliary contacts of an auxiliary contact module comply with the demands of positive operation. Auxiliary N/O contacts are positively driven against auxiliary N/C contacts on the same auxiliary contact Control voltage Type Article number 24 V DC CMD(24VDC) 106170 110 V/50 Hz, CMD(110-120VAC) 106171 120 V/60 Hz 230 V/50 Hz, 240 V/60 Hz CMD(220-240VAC) 106172 Most of the conventional safety-related control circuits operate at 24 VDC. However, with larger drive systems 230 V/50 Hz, 240 V/60 Hz are used and in American systems 110 V/50 Hz, 120 V/60 Hz are used. The variants thus cover the typical control voltages for contactor drives (Figure 8). Permissible combinations In order to guarantee a reliable functioning of the combinations of circuitbreaker/switch-disconnectors, contac- Reliable signalling using auxiliary contacts The quality of the signal relating to the state of the power contacts is decisive in the described application. Welding of the power contacts must be reliably detected. The IEC EN 60947 standard for electrical low-voltage switchgear has defined the term mirror contacts for this purpose. A mirror contact on a contactor is an auxiliary N/C contact that can only close if all power contacts have opened. All auxiliary N/C contacts on the threepole contactors DILM 7 to DILM 1600 and DILH 1400 to DILH 2000 and the four-pole contactors DILM P comply with the demands of a mirror contact (Figure 7). With the (high power) contact modules the side-mounted auxiliary contacts NHI2-11S-PKZ2 comply with the demands for a mirror contact. As it is also possible that an auxiliary N/C contact can weld, monitoring is also necessary here. The IEC EN 60947 standard Figure 8: Contactor monitoring relay CMD 5

Contactor type Control voltage CMD (24 VDC) DILM 7 to DILM 15 24 VDC DILM 17 to DILM 500 RDC24 SE1A-G-10-PKZ2, S-G-PKZ2 24 VDC CMD (110-120 VAC) DILM 7 to DILM 95 110 V 50 Hz, 120 V 60 Hz 110 V 50/60 Hz DILM 115 to DILM 170 RAC120 DILM 185 to DILM 1600 RA110, RA250 SE1A/..-PKZ2, S-PKZ2 110 V 50 Hz, 120 V 60 Hz 110 V 50/60 Hz CMD (220-240 VAC) DILM 7 to DILM 95 230 V 50 Hz, 240 V 60 Hz 220 V 50 Hz, 240 V 60 Hz 220 V 60 Hz 240 V 50 Hz 220 V 50/60 Hz 230 V 50/60 Hz DILM 115 to DILM 170 RAC240 DILM 185-S to DILM 500-S 220-240 V 50/60 Hz DILM 185 to DILM 1600 RA250, RAW250 DILH 1400 to DILH 2000 RAW250 SE1A/..-PKZ2, S-PKZ2 230 V 50 Hz, 240 V 60 Hz 220 V 50 Hz, 240 V 60 Hz 220 V 60 Hz 240 V 50 Hz 230 V 50/60 Hz tors and CMD, only defined components are approved for use. Other contactors featuring other switching times or undervoltage releases with other voltage levels can cause a loss of the safety function. Contactors The following contactors are approved for establishing safety relevant control sections: The contactor must feature an auxiliary N/C contact with mirror contact functions and a further auxiliary contact that is positively-driven to the mirror contact (Figure 9). Circuit-breaker/switch-disconnector The CMD is approved with the following circuit-breakers / switch-disconnectors (Figure 10): Switch PKZ2 NZM1, N1 NZM2, N2 NZM3, N3 NZM4, N4 Undervoltage release U-PKZ2(18VDC) NZM1-XUVL NZM2-XUV NZM3-XUV NZM4-XUV Safety-relevant observation of the CMD From the safety technology perspective a circuit consists of two parallel paths: The contactor The series connection of CMD and undervoltage release MTTF d of the circuit The MTTF d time is calculated separately for both paths. For contactors the MTTF d time is dependent mainly on the switching conditions of the application. A contactor that switches once a day will achieve a significantly higher MTTF time than a contactor that must switch every 5 seconds (12 x 60 x 8 switching operations per day). Eaton Moeller cannot define fixed MTTF times for the observation as a result. Eaton Moeller provides the B10 d values for calculation of the MTTF d time of the application in question. In combination with the application data the MTTF values of the contactors can be calculated using formula 1: MTTF d B = 1 10d 0, nop where n op : average count of annual switching operations Figure 9: Contactor with fitted auxiliary contacts Figure 10: Circuit-breaker with fitted undervoltage release 6

Contactor DILM 7 to DILM 12 DILM 15 DILM 17 to DILM 65 DILM 72 DILM 80 to DILM 150 DILM 170 DILM 185 to DILM 820 DILM 1000 to DILM 1600 B 10d value at 400 V AC-3 1.3 million switching operations 0.75 million switching operations 1.3 million switching operations 0.75 million switching operations 1.3 million switching operations 0.75 million switching operations 1.3 million switching operations 0.3 million switching operations The following table provides the B10 d values for calculation purposes with AC-3 applications at 400 V: The MTTF d time of the CMD relay is 125 years under the condition that a maximum switching frequency of n op = 350,400 switching operations / year is not exceeded. The B 10d values of the undervoltage release are: Undervoltage release PKZ 2 NZM 1, NZM 2 NZM 3 NZM 4 B 10d value 10,000 switching operations 10,000 switching operations 7,500 switching operations 5,000 switching operations Diagnostic coverage of the circuit The Diagnostic Coverage is also calculated separately for both branches. As the contactor is switched operationally and the state with each switch operation is checked by the auxiliary N/C contact with mirror contact, the error detection on the contactor is very high: DC contactor: = 99 % In contrast to the contactor, the undervoltage release is a dormant component. The functional capability of the undervoltage release cannot be operationally tested. By additional testing of the circuit once a year a DC=90 % is achieved for the undervoltage release. The Diagnostic Coverage of the CMD DC = 90 % Performance Level of the circuit The parallel connection of the CMD and undervoltage release to a contactor complies with Performance Level PL=e. The calculation is subject to the following preconditions: Maximum operations of the contactor: 350,400 switching operations / year Maximum switching operations of the undervoltage release: 1095 switching operations / year In the calculation of the overall Performance Level for the control the upstream safety components must be considered. Overall, controls that comply with Performance Level d can be established in this way. Summary The CMD is used in safety-relevant current circuits. It monitors if the main contacts of the contactor have welded. If welding is detected, it switches off the supply of power to the application using the upstream circuit-breaker. Using the CMD, controls that comply with Performance Level d can be set up. 7

Eaton Corporation Eaton is a leading power management company. Eaton operates worldwide with products, systems and services in the electrical, hydraulic, aerospace, truck and automotive sectors. Eatons Electrical Sector Eatons Electrical Sector is the worldwide leader in products, systems and services for energy distribution, safe electricity supply and automation in industrial, residential and purpose-built buildings, public facilities, energy providers, commerce and OEMs. E-Mail: Internet: Publisher: Eaton Corporation Electrical Sector EMEA Eaton Industries GmbH Hein-Moeller-Str. 7 11 D-53115 Bonn info-bonn@eaton.com www.eaton.com/moellerproducts 2010 by Eaton Industries GmbH Subject to alterations VER2100-961GB ip 01/11 Printed in Germany (01/11) Article No.: 113748 Eaton Electrical Sector includes the brands Cutler-Hammer, Moeller, Micro Innovation, Powerware, Holec, MEM and Santak. www.eaton.com