E650 Series 3 (ZMD310AT/CT)

Similar documents
Energy Management Energy Meter Type EM23 DIN

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

3-phase, bidirectional energy meter

38 Series - Relay interface modules A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Quick Connect. quick - simple - efficient.

RM4TG20 three-phase network control relay RM4-T - range V

Voltage Regulator SPAU 341 C. Product Guide

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Rack mounted telephone- and leased line modem for industrial applications

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Analog signal converters CC-E I/I Current / current isolators

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

HYDRUS ULTRASONIC METER

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

MasterINTERFACE 39 Series - Relay interface modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Relés e Contatores de Estado Sólido SIRIUS

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Control Devices Catalogue. Control Devices. Preferred and Standard Products

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

Waveguide Access Point WGA631. Product Guide

80 Series - Modular timers 16 A. Features

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Telephone- and leased line modem for industrial applications TD-36

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

3-Phase Energy meter with serial S-Bus interface

MasterINTERFACE 39 Series - Relay interface modules

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

15 Series - Electronic step relay and dimmer. Features SERIE

PHOENIX CONTACT Features

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Type: DILM32 10(24V50HZ) Article No.:

Thermistor motor protection

48 SERIES Relay interface modules 10 A

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Power Meter Series 700

A project to optimise quality and energy efficiency must include metering

Disturbance Recoder SPCR 8C27. Product Guide

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Type: DILM9 10(24VDC) Article No.:

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

Features. Picture. Specifications

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Digital input modules

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Polyphase kwh Electricity Meter

PCS0100en Persy Control Services B.V. Netherlands

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

E-STOP relays, safety gate monitors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PNOZsigma - Base units

E-STOP relays, safety gate monitors

5235 Single Phase Credit Meter

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Flexible Counter Series in DIN size 24 x 48 mm

49 Series - Relay interface modules A. Features

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Main catalog. Electricity meters For modular enclosures and DIN rail

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

80 Series - Modular timers 16 A. Features

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Capacitor Protection Relay SPAJ 160 C. Product Guide

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Air damper actuators

Modular I/O System Analog and Digital Interface Modules

Bulletin 150 SMC Flex Smart Motor Controller Specifications

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

E-STOP relays, safety gate monitors

Transcription:

Electricity Meters IEC/MID Industrial+Commercial ZMD310AT/CT E650 Series 3 (ZMD310AT/CT) Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E650 series 3, the latest generation of ZxD300 meters. These meters feature a new hardware platform, combining modern technology with proven functions. Date: 06.04.2010 Filename: D000030104 E650 ZMD300xT series 3 Technical Data D000030104 d

2/6 The E650 directly connected I&C meters record active and reactive energy consumption in all threephase four-wire and three-phase three-wire networks. Range E650 meters are the answer to a wide range of specific needs: from the reliable commercial meter to the complex measuring device with comprehensive additional functionality for sophisticated data acquisition and flexible tariff control of large industrial customers. E650 Series 3 ZMD310AT/CT General Voltage Nominal voltage U n Voltage range 3 x 220/380 V to 240/415 V 3 x 110/190 V to 133/230 V 80% to 115% U n Frequency Nominal frequency f n 50 or 60 Hz tolerance ± 2% IEC-specific Data Current Base current I b selectable: 5, 10, 20 or 40 A Maximum current I max metrological selectable: 40, 60, 80, 100 or 120 A thermal 120 A Short circuit 10 ms 5000 A Measurement Accuracy ZMD310xT active energy, to IEC 62053-21 class 1 reactive energy, to IEC 62053-23 accuracy 1% Measurement Behaviour Starting current according to IEC 0.4% I b typical 0.3% I b The startup of the meter is controlled by the starting power and not by the starting current. Starting power in M-circuit nominal voltage x starting current single phase Communication AT/CT- meters are equipped with modular communication units which provide the right choice for the best data channel at all times. «Plug+Play» modules also offer you full freedom of choice for deployment of new communication technologies. Installation support The monitoring of voltage, current, demand and power factor supports the installation. Technical specifications MID-specific Data Current (for class B) Minimum current I min Transitional current I tr Maximum current I max 0.25, 0.5, 0.75, 1.0 A 0.5, 1.0, 1.5, 2.0 A 120 A Measurement Accuracy to EN 50470-3 ZMD310AT/CT class B Measurement Behaviour Starting current I st 0.02, 0.04, 0.06, 0.08 A General Operating Behaviour Voltage failure (Power Down) bridging time data storage switch off 0.5 s after another 0.2 s after approx. 2.5 s Voltage restoration (Power Up) function standby 3 phases after 2 s function standby 1 phase after 5 s detection of energy direction and phase voltage after 2 to 3 s Power Consumption Power consumption per phase in voltage circuit phase voltage 110 V 240 V active power (typical) 0.5 W 0.7 W apparent power (typical) 1.0 VA 1.7 VA Power consumption per phase in current circuit phase current 10 A apparent power (typical) 0.03 VA Landis+Gyr AG D000030104 d E650 Series 3 (ZMD310AT/CT) Technical Data

3/6 Environmental Influences Temperature range to IEC 62052-11 operation 25 C to +70 C storage 40 C to +85 C Temperature coefficient range 25 C to +70 C average value (typical) ± 0.012% per K at cosϕ=1 (from 0.05 I b to I max ) ± 0.02% per K at cosϕ=0.5 (from 0.1 I b to I max ) ± 0.03% per K Impermeability to IEC 60529 IP51 Electromagnetic Compatibility Electrostatic discharges to IEC 61000-4-2 contact discharge 15 kv Electromagnetic RF fields to IEC 61000-4-3 80 MHz to 2 GHz 10 and 30 V/m Radio interference suppression according to IEC/CISPR 22 class B Fast transient burst test to IEC 61000-4-4 current and voltage circuits under load according to IEC 62053-21/23 4 kv auxiliary circuits > 40 V 2 kv Fast transient surge test to IEC 61000-4-5 current and voltage circuits 4 kv auxiliary circuits > 40 V 1 kv Insulation Strength Insulation strength 4 kv at 50 Hz during 1 min. Impulse voltage 1.2/50 μs to IEC 62052-11 current and voltage circuits 8 kv auxiliary circuits > 40 V 6 kv Protection class ll to IEC 62052-11 Display Characteristics LCD liquid crystal display digit size in value field 8 mm number of digits in value field up to 8 digit size in index field 6 mm number of digits in index field up to 8 Inputs and Outputs Control inputs control voltage U S input current 100 to 240 V AC < 2 ma ohmic at 230 V AC Output contacts solid state relay voltage 12 to 240 V AC/DC max. current 100 ma max. switching frequency (pulse length 20 ms) 25 Hz Optical test outputs active and reactive energy red LED number 2 meter constant selectable Communication Interface Optical interface to IEC 62056-21 serial, bidirectional, half-duplex max. transmission rate 9600 bps protocols IEC 62056-21 and dlms Communication units Exchangeable communciation units for various applications Additional Power Supply (optional) On Extension Board 045x nominal voltage range 100 to 240 V AC/DC tolerance 80 to 115% U n frequency 50 or 60 Hz max. power consumption 6.8 W Calendar Clock Calendar Type Accuracy Gregorian or Persian (Jalaali) < 5 ppm On Extension Board 046x nominal voltage range tolerance max. power consumption 12 to 24 V DC 80 to 115% U n 3.5 W Backup time (power reserve) with supercap charging time for max. backup time with battery (optional) battery > 20 days 300 h 10 years CR-P2 D000030104 d E650 Series 3 (ZMD310AT/CT) Technical Data Landis+Gyr AG

4/6 Weight and Dimensions Weight External dimensions width height (with short terminal cover) height (with standard terminal cover) height (with extended hook) depth Suspension triangle height (with extended hook) height (suspension eyelet open) height (suspension eyelet covered) width Terminal cover short standard long GSM ZxB- 80 mm ZxB- 110 mm ADP1 adapter RCR/FTY adapter approx. 1.5 kg 177 mm 244 mm 281.5 mm 305.5 mm 75 mm 230 mm 206 mm 190 mm 150 mm no free space 40 mm free space 60 mm free space 60 mm free space 80 mm free space 110 mm free space Connections Phase Connections screw terminals diameter for I max 80 A 8.5 mm diameter for I max > 80 A 9.5 mm minimal conductor cross section 4 mm 2 max. cross section cable 35 mm 2 (up to 120 A) max. cross section strand 25 mm 2 (up to 80 A) screw head Pozidrive Combi No. 2 screw dimension M6 x 14 max. screw head diameter 6.6 mm tightening torque < 3 Nm Other Connections screwless spring- terminal max. current of voltage outputs 1 A max. voltage of inputs 250 V Material Housing Polycarbonate, partly glass-fibre reinforced Landis+Gyr AG D000030104 d E650 Series 3 (ZMD310AT/CT) Technical Data

5/6 Meter Dimensions (standard terminal cover) 75 40 26 190 standard hook: 206 extended hook: 230 150 177 Terminal Dimensions Ø 8.5 or Ø 9.5 15.3 19.75 14.5 14.5 14.5 14.5 14.5 14.5 12 19 16 13 16 13 16 13 13.5 Spacings of terminal openings Spacings of terminal stampings for smaller conductors Terminal Layout Inputs and/or output contacts of extension board Pulse inputs Communication interfaces Communication unit U1 U2 U3 N Control inputs and output contacts Voltage outputs L1 L2 L3 N Phase connections D000030104 d E650 Series 3 (ZMD310AT/CT) Technical Data Landis+Gyr AG

6/6 ZMD 3 10 C T 44 4207 S3a Network Type ZMD 3-phase 4 wire network (M-circuit) Connection Type 3 Direct connection Accuracy Class 10 Active energy class 1 (IEC), B (MID) Measured Quantities C A Construction T Tariffication 21 24 41 44 Additional functions 060x 240x 420x 045x 046x Active and reactive energy Active energy With exchangeable communication units Energy rates, external rate control via control inputs Energy rates, internal rate control via time switch (additionally possible via control inputs) Energy and demand rates, external rate control via control inputs Energy and demand rates, internal rate control via time switch (additionally possible via control inputs) All versions with 3 control inputs and 2 output contacts 6 outputs 2 control inputs, 4 outputs 4 control inputs, 2 outputs 4 outputs, auxiliary power supply 100 to 240 VAC 4 outputs, auxiliary power supply 12 to 24 VDC xxx0 xxx2 xxx7 xxx9 no additional functions DC-magnet-detection load profile DC-magnet-detection and load profile Series 3 Copyright 2009, Landis+Gyr. All rights reserved. Subject to change without notice. Landis+Gyr AG Feldstrasse 1 CH-6301 Zug Switzerland Phone: +41 41 935 6000 www.landisgyr.com Landis+Gyr AG D000030104 d E650 Series 3 (ZMD310AT/CT) Technical Data