CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

Similar documents
USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Advantium 2 Plus Alarm

M&C Software. for Windows. Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

BroadBand PowerShield. User Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual

Sip/Puff Switch User Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Triple Expansion Chassis

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

MCR1900 Media Converter 19-Slot Chassis

MACTek Corporation. USB HART Interface. Users Manual

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

TTL to RS232 Adapter User Guide

INSTRUCTION MANUAL MODEL PCD-88

Signal Manager Installation and Operation Manual

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

Model PS-4001 Power Supply User Instructions

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

How To Install A Power Supply (Uplast) With A Battery Pack

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

User Guide. HDMI Active Cable Extender. DVI-7370c

Powerware Relay-Serial Card User s Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

About this Manual. Support for Your Product

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Installation & User Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Single Station Remote Alarm

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

Dolphin 9900 Mobile Computers

AXIS 291 1U Video Server Rack Installation Guide

Wireless Base Station Single and Multiple Headsets

u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

HA5. HDMI To HD-SDI/SDI Video and Audio Converter User Manual

DVI to Analog Converter

Zetron Desktop Microphone Manual F

Instructions A Amp AC/DC Current Probe

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

How To Use A Cdm250 Digital Multimeter

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Owner s Manual & Safety Instructions

Intelli-Time Alarm Clock model 13027

24-Port Channelized E1/T1 Line Card Overview

Conversion Formulas and Tables

Current Probes. User Manual

u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions

Single Port T1/E1 Tap

NFC Communication Tray Model: HHX-IT3-Z

MIDAS. Event Log Viewer User s Guide. Part Number MN/MID-EVLOG.IOM Revision 0

Instructions & Safety Information Models A220-20D and A220-20L Version 2

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

HotLok Pass Through Blanking Panel

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

2-Way Wireless Indoor Siren Installation Guide

Original instructions Tina 3A/Aps Adaptor unit

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

VPCCCare. Virtual PC Center Service Warranty Program

User Manual. Humidity-Temperature Chart Recorder. Model RH520

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

About Your NetBotz 4-20mA Sensor Pod

UIM-2T1 T1 Loop Bonding Uplink Interface Module

Global Water Instrumentation, Inc.

16/32 Channel 1U Rack Mount CCTV Power Supply

CABLE MODEM QUICK START

Video Splitter VS-104 / VS-108 User's Manual

Park 250 Brushless Outrunner Instructions

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

ENGLISH FRANÇAIS DEUTSCH ESPAÑOL ÐÓÑÑÊÈÉ

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

Quick Installation Guide. 1000Base-SX/LX Fiber Converters

USER MANUAL. Kramer Electronics, Ltd. Models:

EzFlex Combustible Gas Leak Detector Model EZ40

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Dual-Cool Notebook Cooler Pad. User s Manual

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

PS/2 Extender USER MANUAL.

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Tina 2A/B Adaptor unit


TWO/FIFTY/TWO STEREO POWER AMPLIFIER

Benchtop Computer Monitor Generator

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Transcription:

CIC-50 T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems) Part Number MN/CIC50.IOM Revision 1

Errata A Comtech EF Data Documentation Update Subject: Revised Paragraph 3.1.4 Pin Assignments Date: October 14, 2002 Document: CIC-50 T1/E1 G.703 Interface Converter, Installation and Operation Manual, Rev. 1, dated October 20, 1999 Part Number: MN/CIC50.EA1 Collating Instructions: Attach this page to page 4 Comments: The following changes provide updated information for Para. 3.1.4. This information will be incorporated into the next revision. Change Specifics: 3.1.4 T1/E1 BALANCED 15 PIN D-SUB PINOUT Pin Connection 1 SD-A 9 SD-B 3 RD-A 11 RD-B 2 Ground 4 6, 7, 8, 14, & 15 Reserved for redundancy system. Filename: T_ERRATA 1

CIC-50 T1/E1 G.703 Interface Converter Installation and Operation Manual Comtech EFData is an ISO 9001 Registered Company. Part Number MN/CIC50.IOM Revision 1 Octember 20, 1999 Copyright Comtech EFData, 2000. All rights reserved. Printed in the USA. Comtech EFData, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 333-2200, FAX: (480) 333-2161.

Customer Support Contact the Comtech EFData Customer Support Department for: Product support or training Information on upgrading or returning a product Reporting comments or suggestions concerning manuals A Customer Support representative may be reached at: Comtech EFData Attention: Customer Support Department 2114 West 7th Street Tempe, Arizona 85281 USA (480) 333-2200 (Main Comtech EFData Number) (480) 333-4357 (Customer Support Desk) (480) 333-2161 FAX or, E-Mail can be sent to the Customer Support Department at: service@comtechefdata.com Contact us via the web at www.comtechefdata.com. 1. To return a Comtech EFData product (in-warranty and out-of-warranty) for repair or replacement: 2. Request a Return Material Authorization (RMA) number from the Comtech EFData Customer Support Department. 3. Be prepared to supply the Customer Support representative with the model number, serial number, and a description of the problem. 4. To ensure that the product is not damaged during shipping, pack the product in its original shipping carton/packaging. 5. Ship the product back to Comtech EFData. (Shipping charges should be prepaid.) For more information regarding the warranty policies, see Warranty Policy, p. vii. ii Rev.1.0

Table of Contents CUSTOMER SUPPORT... II ABOUT THIS MANUAL... IV Conventions and References...iv Reporting Comments or Suggestions Concerning this Manual...iv WARRANTY POLICY... VII Limitations of Warranty...vii Exclusive Remedies...vii Disclaimer...vii CHAPTER 1. INTRODUCTION...1 CHAPTER 2. INSTALLATION...2 CHAPTER 3. OPERATION...3 3.1.1 MODE SELECT...3 3.1.2 AMI or HDB3/B8ZS...4 3.1.3 E1 BAL or UNBAL...4 3.1.4 T1/E1 BALANCED 15 PIN D-SUB PINOUT...4 CHAPTER 4. INDICATORS AND TROUBLESHOOTING...5 CHAPTER 5. SUMMARY OF SPECIFICATIONS...6 Rev.1.0 iii

Preface CIC-50 T1/E1 G.703 Interface Converter About this Manual This manual provides installation and operation information for the Comtech EFData CIC-50 T1/E1 G.703 Interface Converter. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the CIC-50 T1/E1 G.703 Interface Converter. Conventions and References Cautions and Warnings CAUTION CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. WARNING indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. WARNING Metric Conversion Metric conversion information is located on the inside back cover of this manual. This information is provided to assist the operator in cross-referencing English to Metric conversions. Trademarks Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Reporting Comments or Suggestions Concerning this Manual Comments and suggestions regarding the content and design of this manual will be appreciated. To submit comments, please contact the Comtech EFData Customer Support Department. iv Rev.1.0

CIC-50 T1/E1 G.703 Interface Converter Preface SAFETY NOTICES ELECTRICAL SAFETY The CIC-50 1:1 Redundancy Switch has been shown to comply with the following safety standard: EN 60950: Safety of Information Technology Equipment, including electrical business machines The equipment is rated for operation at +12 volts DC and -12 volts DC. It has a maximum power consumption of 2.0 watts. The power supply current is, in all circumstances, supplied by a single Comtech CDM-550/550T Modem. The User should observe the following instructions: Equipment Connection The CIC-50 is designed for operation ONLY with Comtech CDM-550 or CDM-550T Modems. These Modems supply DC operating current (electronically fused and protected) and control signals for the correct functioning of this unit. Connection to other manufacturer s equipment could result in damage to the unit. Environmental The CIC-50 must not be operated in an environment where the unit is exposed to extremes of temperature outside the ambient range 0 to 500C, precipitation, condensation, or humid atmospheres above 95% RH, altitudes (un-pressurised) greater than 2000 meters, excessive dust or vibration, flammable gases, corrosive or explosive atmospheres. Operation in vehicles or other transportable installations which are equipped to provide a stable environment is permitted. If such vehicles do not provide a stable environment, safety of the equipment to EN60950 may not be guaranteed. Rev.1.0 v

Preface CIC-50 T1/E1 G.703 Interface Converter Telecommunications Terminal Equipment Directive In accordance with the Telecommunications Terminal Equipment Directive 91/263/EEC, this equipment should not be directly connected to the Public Telecommunications Network. EMC (ELECTROMAGNETIC COMPATIBILITY) The CIC-50 T1/E1 G.703 Interface Converter has been demonstrated, by independent testing, to comply with the following standards: Emissions: EN 55022 Class B - Limits and methods of measurement of radio interference characteristics of Information Technology Equipment. FCC Part 15 Class B Immunity: EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic, commercial and light industrial environment. In order that the CIC-50 continues to comply with these standards, observe the following instructions: All 'D' type connectors attached to the unit must have back-shells which provide continuous metallic shielding. Cable with a continuous outer shield (either foil or braid, or both) must be used, and the shield must be bonded to the back-shell. The equipment must be operated with its cover on at all times. If it becomes necessary to remove the cover, the User should ensure that the cover is correctly re-fitted before normal operation commences. vi Rev.1.0

CIC-50 T1/E1 G.703 Interface Converter Preface Warranty Policy This Comtech EFData product is warranted against defects in material and workmanship for a period of two years from the date of shipment. During the warranty period, Comtech EFData will, at its option, repair or replace products that prove to be defective. For equipment under warranty, the customer is responsible for freight to Comtech EFData and all related custom, taxes, tariffs, insurance, etc. Comtech EFData is responsible for the freight charges only for return of the equipment from the factory to the customer. Comtech EFData will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EFData. Limitations of Warranty The foregoing warranty shall not apply to defects resulting from improper installation or maintenance, abuse, unauthorized modification, or operation outside of environmental specifications for the product, or, for damages that occur due to improper repackaging of equipment for return to Comtech EFData. No other warranty is expressed or implied. Comtech EFData specifically disclaims the implied warranties of merchantability and fitness for particular purpose. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Comtech EFData shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. Disclaimer Comtech EFData has reviewed this manual thoroughly in order that it will be an easy-touse guide to your equipment. All statements, technical information, and recommendations in this manual and in any guides or related documents are believed reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should they be understood to be, representations or warranties concerning the products described. Further, Comtech EFData reserves the right to make changes in the specifications of the products described in this manual at any time without notice and without obligation to notify any person of such changes. If you have any questions regarding your equipment or the information in this manual, please contact the Comtech EFData Customer Support Department. Rev.1.0 vii

Preface CIC-50 T1/E1 G.703 Interface Converter This page is intentionally left blank. viii Rev.1.0

1Chapter 1. INTRODUCTION While the CDM-550/550T modem is capable of data rates up to 2048 kbps, its standard interface is limited to EIA-422, V.35 and EIA-232 formats only. In order to accommodate the G.703 data formats commonly used at 1544 kbps (T1) and 2048 kbps (E1), the CIC-50 converter attaches to the rear of the modem at the 25-pin data connector. No external power is required and all settings are made on the CIC-50 using three switches. Two LED indicators are also present for monitoring the condition of the G.703 terrestrial link. Rev. 1 1

. CIC-50 T1/E1 G.703 Interface Converter 2Chapter 2. INSTALLATION 1. Power down the modem before installing the converter. 2. Remove the six flathead screws (four on the sides, two on top) and lift off the cover of the CIC-50. 3. The 25-pin male D-sub connector includes two captive screws which can be reached by sliding a screwdriver through the holes located at the opposite end of the CIC-50. The only reason for removing the cover is to clearly guide the screwdriver to these captive screws. 4. Attach the CIC-50 to the CDM-550 modem by mating the two 25-pin D-subs together, then tighten the two captive screws. 5. Re-attach the cover and replace the six flathead screws. The metal surfaces of the modem and CIC-50 should be flush and the three format indicator LEDs should safely recess into the modem chassis. 2 Rev. 1

CIC-50 T1/E1 G.703 Interface Converter. 3Chapter 3. OPERATION After applying power to the modem, the following configuration changes must be made to the modem in order for it to operate with the CIC-50. Program the transmit and receive data rates to either 1544 or 2048 kbps. Both directions must be at the same rate. Set the data interface type to EIA-422. The modem itself operates in this electrical format while the converter translates between EIA-422 and G.703. Set the transmit clocking to INT. This is required so that the modem s internal transmit data rate clock is driven to the converter on the ST lines to provide a high stability reference for the G.703 clock recovery circuitry. The recovered clock and data drive into the modem on the TT and SD lines, respectively. Three switches must be set properly on the CIC-50, depending upon the specific G.703 format in use. They can be accessed with a small screwdriver. 3.1.1 MODE SELECT 0 E1, always used with a 2048 kbps data rate. 1-2 Unused. 3 T1(1), used at 1544 kbps and short cable lengths of 0-133 feet. 4 T1(2), used with 133-266 ft. cable. 5 T1(3), used with 266-399 ft. cable. 6 T1(4), used with 399-533 ft. cable. 7 T1(5), used with 533-655 ft. cable. Rev. 1 3

. CIC-50 T1/E1 G.703 Interface Converter 3.1.2 AMI or HDB3/B8ZS For both T1 and E1 formats, this sets the G.703 output to either the uncoded Alternate Mark Invert (AMI) format, or to the appropriate zero substitution line code used for T1 (B8ZS) or E1 (HDB3). 3.1.3 E1 BAL or UNBAL For E1 only, this adjusts the impedance on the G.703 input between 120 ohms for balanced and 75 ohms for unbalanced. The 15-pin D-sub connector should be used for balanced and the two BNC connectors for unbalanced. For T1 this selection is a don t care since unbalanced is not an option, and the D-sub connector must always be used. 3.1.4 T1/E1 BALANCED 15 PIN D-SUB PINOUT Pin Balanced G.703 Tx (Inputs) 3, 11 Balanced G.703 Rx (Outputs) 2, 4 Ground 6, 7, 8, 14, 15 Don t Connect (reserved for redundancy system) 4 Rev. 1

CIC-50 T1/E1 G.703 Interface Converter. 4Chapter 4. INDICATORS AND TROUBLESHOOTING After configuring both the CDM-550 and the CIC-50, two indicators are available on the CIC-50 to monitor the condition of the incoming G.703 data. If no marks are received over 175 bit times at T1 or 32 bit times at E1, the Loss Of Signal LED will illuminate. This will not activate an alarm on the CDM-550, but the CIC-50 will generate AIS (all ones) data into the modem timed directly off the internal clock reference provided to it. Therefore, activating the TX-AIS alarm will allow the modem to indirectly monitor this condition. The other indicator is the Bipolar Violation LED. AMI coding dictates that each mark received at the G.703 input be of alternating polarity. Enabling the HDB3/B8ZS line coding presumes the use of zero substitution patterns that include intentional Bipolar Violations (BPV). Since this LED will be pulsed with each BPV found, it will not only illuminate when format errors are present, but also if the incoming data is using HDB3/B8ZS while the CIC-50 is set for AMI. This mismatch will cause errors in the data path and should be corrected. It is recommended that HDB3/B8ZS always be selected on the CIC-50 s switch unless the user is certain that line coding will never be present. Note: CDM-550 only - if using software releases before Version 1.10, the I/O LOOP test mode will not operate properly with the CIC-50. Please call the factory for a free software upgrade. The CDM-550T is not affected. Rev. 1 5

. CIC-50 T1/E1 G.703 Interface Converter 5Chapter 5. SUMMARY OF SPECIFICATIONS Equipment Type T1/E1 G.703 Interface Converter Modems Supported Comtech EFData CDM-550 and CDM-550T Digital Satellite Modems Operating Modes E1 (2048 kbps) balanced (120 ohms) and unbalanced (75 ohms) T1 (1544 kbps) unbalanced (100 ohms) Per ITU Recommendation G.703 Jitter and Wander Per ITU Recommendations G.823 and G.824 Power requirements 2.0 Watts maximum +12 volts DC -12 volts DC (Power is supplied by the Modem. These power supplies are electronically fused and protected.) Approvals CE as follows: EN 55022 Class B (Emissions) EN 50082-1 (Immunity) EN 60950 (Safety) FCC Part 15 Class B 6 Rev. 1

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter 0.3937 0.03281 0.01094 6.214 x 10-6 0.01 1 inch 2.540 0.08333 0.2778 1.578 x 10-5 0.254 25.4 1 foot 30.480 12.0 0.3333 1.893 x 10-4 0.3048 1 yard 91.44 36.0 3.0 5.679 x 10-4 0.9144 1 meter 100.0 39.37 3.281 1.094 6.214 x 10-4 1 mile 1.609 x 10 5 6.336 x 10 4 5.280 x 10 3 1.760 x 10 3 1.609 x 10 3 1.609 1 mm 0.03937 1 kilometer 0.621 Temperature Conversions Unit Fahrenheit Centigrade Formulas 32 Fahrenheit 0 (water freezes) C = (F - 32) * 0.555 212 Fahrenheit 100 (water boils) F = (C * 1.8) + 32-459.6 Fahrenheit 273.1 (absolute 0) Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoir. Pound Troy Kilogram 1 gram 0.03527 0.03215 0.002205 0.002679 0.001 1 oz. avoir. 28.35 0.9115 0.0625 0.07595 0.02835 1 oz. troy 31.10 1.097 0.06857 0.08333 0.03110 1 lb. avoir. 453.6 16.0 14.58 1.215 0.4536 1 lb. Troy 373.2 13.17 12.0 0.8229 0.3732 1 kilogram 1.0 x 10 3 35.27 32.15 2.205 2.679

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX