How To Prevent A Forklift From Tipping

Similar documents
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

How To Use A Flowmeter

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

THERMAL ENERGY METER MC 108/ET

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Controlers. Controler

Panel Meters and Controllers Modular Panel Meter Type EDM 35

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

MOTION COORDINATOR MC206X Quick Connection Guide

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Multifunction devices

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

O C M III. Open Channel Flow Monitor

Electric Rotary Actuator - On/Off or programmable control actuator

SMS GSM Alarm Messenger

photoelectric highlights

ATL Fuel Level Sender Probes

On-line Machine Condition Monitoring [The CMS System]

for CS flow / dew point sensors

Series 7500 Torque Sensor

Vehicle Tracking and OBD Information

MC2M : DOUBLE CORE MULTIPURPOSE CONTROLLER

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Controller board and power supply for vivimat III systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

IFC 070 Technical Datasheet

Inwall 4 Input / 4 Output Module

IMVIB. Online vibration monitoring for Ariel compressors

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Turbine Flow Sensor Series VTR

38 Series - Relay interface modules A

CONFIGURABLE SAFETY RELAYS

is then retained absolutely without interruption.

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

3500/62 Process Variable Monitor

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

WD-AMX Water Detection Controllers

USER MANUAL V5.0 ST100

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

Falcon Protector Tracking System

ENAiKOON ultrasonic fuel-level sensor

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

Unidirectional Transmitter/ Receiver Units Introduction

Vibration Monitoring System Adash 3600

Triple Waveband Infra-Red Flame Detection

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Electron S.R.L. B55 CNC TRAINING MACHINES

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Proportional pressure regulators VPPE

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

GAM900/GAM900S. Acceleration precisely measured and safely monitored

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

W150: Miniature photoelectric switch series with completely integrated electronics

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

SMART SENSOR COLLECTION

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

3500/40M Proximitor* Monitor

and Accelerometers

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Sense it! Connect it! Bus it! Solve it! EncoderS

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

MultiViu Flex 7 Data Sheet

Inwall Room Temperature Unit

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Transcription:

The device "SSR-200" is a tool to implement security and agricultural machinery operators against the risk of tipping as a result of traveling on land too steep / inclined. Moreover, in case of actual rollover, will automatically switch off the machine functions by limiting the dangers arising from the state of tipping. Through the continuous monitoring of the transverse axis and the longitudinal axis of the machine according to thresholds programmable, reaching / exceeding the values set in the device shall emit a signal (on-off or proportional with increasing intensity) to alert 'operator hazard. If the machine were to swing (maximum threshold is exceeded) the device stops a second signal for supplying a safety switch (normally supply combustion engine). The device is of particular interest for the application of all those machines with rotating tools (blades, mulches, etc..), Where today, in the event of rollover, disconnection command tool is entrusted exclusively to the operator. Another possible application is to control and safeguard against the operation of the internal combustion engine beyond the limits of inclination specified by the manufacturer. With the model PLUS is possible to obtain precise measurements even at medium-high speed with the aid of eight digital inputs which can measure the angular velocity of the medium. The patented with patent number RE2008A000048. SPECIFICATIONS: Power supply: 12V Model... (7V/15V). Model... 24V (15V/30V) Power consumption:... 200mA Operating Temperature... : -40 to +85 C Sensitivity:......... 0.1 Mean error:...... 0.1 Accelerometers 3-AXIS X, Y, Z:... 2... Output: 1. # 2 RELAY 'tipping NC contacts in series Alarm maximum current:... 2... 16A. Early warning tipping Contacts NC:.. maximum current 2A 3. CANBUS port 4. Analog Signal tilt axis X:... 0-10V 0-5V 5. Analog signal Y axis inclination:... 0-10V 0-5V 6. Digital Signal: Open Collector... 9. Digital inputs (selectable NPN or PNP):... No. 8 10. Relay outputs' 1st:...... n 2 Programming via PC (with software range and 1 suite USB-SPI): Auto-learning of leading zeros Setting analog output (5V or 10V) Gain of the analog signal Sensitivity (average value bed set xn readings) field can be set from 1 to 100 readings Angle of operation ALARM relay Angle of operation PRE-ALARM relay Reading in the number of interventions of the PRE and Dell 'ALARM Measurement of the 'corner in Real Time N pulse encoder revolution or transducer Pk Wheel diameter in cm Distance between the wheels in cm Position of the level of the wheel in cm Angular velocity limit Intervals encoder reading (step by 100mS) Pagina 1/5

Metal Box:... 100x100x59 Degree of protection:......ip66/67 When the machine is safety relay contacts are closed, the arrival of a dangerous situation, the relays open up. PRODUCT COMPLIANCE WITH EUROPEAN DIRECTIVE 2002/95/EC CE RHOS Item Code: F00176-000-PLUS PANNELLO VISUALIZZAZIONE (OPTIONAL ) CARATTERISTICHE TECNICHE : Alimentazione :...8-30Vdc Grado di Protezione :... IP 65 lato frontale, IP30 Lato posteriore Temperatura di lavoro:...-20 C + 85 C Temperatura max.: -35 C + 90 C Pulsanti retroilluminati..7 Ingressi Digitali..20 Ingressi Analogici/frequenza..4 Output di potenza (2 Ampère) 4 Line CAN BUS..2 Ingressi NTSC/PAL...4 RS232 input... 1 RS485 input... 1 USB Input... 1 SD Card Slots... 1 GSM module (option)... 1 Connectors: Molex... MINIFIT jr. Dimensions: 170x230x20mm... EMC: ISO 7637-2 ISO 2575 MECHANICAL AND ELECTRICAL FEATURES OF PLASTICS: Silicone: Non-Conductive Max:... -55 C ~ +250 C Specific Gravity 1.15... Tensile Strength:... 90Kg/cm ² Tear Strength:... 20Kgf/cm Compression:... September 60% (180 C x 22hrs.) Elongation at break:... 350% Volume resistivity:... 8 x 1014 ohm cm Breaking Isolation:... 24kV/mm Colour: black... Dielectric Constant:... 4.2 (50Hz) Tangent Dielectric:... 13% (50Hz) High reesistenza to 'alcohol and sweat High resistance to ultra violet rays and detergents Item Code: F00208 Pagina 2/5

APPLICATION EXAMPLES: As in the example in the tractor at the top, the same technology can be applied on a variety of machines, such as Forklifts, Tractors and Telescopic Platforms Scissors. Pagina 3/5

The System Security Forklift Tipping applied on the possibility of being able to control the load in elevation on inclined planes. Thanks to the continuous control of the x and y axes of the machine in the event of an overrun of the angles of security set, intervenes bringing the load in a safety position or blocking its operation. Tractors Telehandler In the Security System Rollover warning authorizes during operation of the machine working angles. In the case of approaching the corner of safety the operator is av-converted with a beep vision. At the overcoming of the angles of safety, the vehicle is stopped or brought within the limits of the security parameters. In the Scissors Platforms Security System Tipping moni-tors the efficiency of the machine through the working angles. In the case of approaching the corner of safety, the operator is alerted by an acoustic signal of view. After successful completion of safety corners are limited working heights of the Platform. Pagina 4/5

wiring Card: Pagina 5/5

DISTANCE BETWEEN FIXING IN mm A = 86mm B = 80mm C = 06mm The company assumes no responsibility for any errors that may appear in this document and reserves the right to change the descriptions and data without prior notice. Pagina 6/5