EN54-16 Voice Alarm System PRODUCT DATASHEETS



Similar documents
ZMR 80 STEREO MODULAR ZONER USERS MANUAL

LOXONE 12 Channel Amplifier

Turbo X channel UHF true diversity

IMPORTANT SAFETY INSTRUCTIONS

1 All safety instructions, warnings and operating instructions must be read first.

Plena Voice Alarm System. Software Manual Configuration Software

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

F(t) Forssell Technologies Inc

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

2nd. 500m* SX2 Remote + Central TX2 Remote. RX2 Central LONG-RANGE REMOTE CONTROL 16 FUNCTIONS. Up to. range

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

PLENA matrix Digital Sound System Surprisingly Flexible. Powerful Control.

User Manual. Please read this manual carefully before using the Phoenix Octopus

T Zone Weekly Timer

Repeaters and Mimics Data Sheet

KIPUS, ONE OF THE LEADING BRANDS IN THE CAR AUDIO WORLD, IS GETTING FULFILL THE DESIRES AND DREAMS OF OUR FANS.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

MPA SERIES MIXER-AMPLIFIER

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

HCS-3600MB2 Conference Main Unit

Plena Voice Alarm System. Installation and Operation manual

Rack mounted telephone- and leased line modem for industrial applications

Line Level Converter Box. S Class Signal Processors

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

M-9000M2 DIGITAL MATRIX MIXER

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

USER GUIDE PREFIX PREMIUM BLEND

Telephone- and leased line modem for industrial applications TD-36

IP Intercom System

Features, Benefits, and Operation

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

Praesideo - Digital Public Address and Emergency Sound System

User Guide FFFA

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

DCS Data and communication server

Radio for Everyone...

Radio for Ever yone...

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

SMS GSM Alarm Messenger

User Manual. For additional help please send a detailed to Support@phnxaudio.com. - 1 Phoenix Audio Technologies

Application/Connection Examples

Digital FM/AM Receiver

miditech Audiolink II

MANUAL PC1000R

MISE - STEREO ENCODER

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Imagine, a sound system that fills every room with crystal clear music & offers unequalled performance, flexibility & simplicity.

HyperX Cloud Headset

Data Sheet-1 CP66 COMMERCIAL PROCESSOR. General Description

Analogue & Digital Audio Interface Equipment

Digital Audio and Data Distribution System

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Plena Loop Amplifier. Installation and User Instructions PLN-1LA10

How To Sell A Talan

LT-82 Stationary IR Transmitter

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Product Information D23m Digital I/O System

ControlSpace ESP-880 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

THE SAS AUDIO ROUTING SWITCHER

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Phase Modular Finally the benefits of Modular ups are for all

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Telephony Systems Trainer CODITEL

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

How To Connect A Tv Box To A Tv Set Top Box With A Tv Antenna From Ikusi

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

PagePac PAGEPAL V

Controlers. Controler

5 CHANNEL MIXER. S Class Signal Processors

Notifier by Honeywell: Voice Alarm Solutions

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

EVOline Multimedia Modules

ETHERNET based public address and voice alarm system

IMPORTANT SAFETY INSTRUCTIONS. When using this electronic device, basic precautions should always be taken, including the following:

GSM GATEWAY PRI / E1 RACK 3U

Chassis, Power Supply, and Element Management

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B


USB-500 Series Stand-Alone, Low-Cost Data Loggers

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Temperature & Humidity SMS Alert Controller

Supplemental to New Product Information (SNPI)

LSM-480 USER MANUAL. A.D.J. SUPPLY EUROPE B.V. Junostraat EW Kerkrade The Netherlands

TrueAlarm Fire Alarm Systems

3500/22M Transient Data Interface

Transcription:

EN54-16 Voice Alarm System PRODUCT DATASHEETS

WayGuard This page is intentionally left blank Pagina 2 di 16

WayGuard Revision history Rel. Data Autore Modifiche 1.00 25/02/15 First emission Pagina 3 di 16

WayGuard This page is intentionally left blank Pagina 4 di 16

WayGuard FOREWORD The Wayguard is a certified EN54-16 voice alarm audio system that is intended to be used in applications where voice evacuation and general public address is needed. The system is configurable upon the layout of the building where it will be installed thanks to its extreme flexibility. Its units and sub-systems allow to setup configuration that will manage up to 108 zones and up to 108 microphone stations. The system can forward recorded alarm messages to dedicated zones. Each zone has two independent and dedicated messages. All signal and data paths are monitored according to the requirements of the EN54-16 regulation. The configuration of the system is made through a dedicated PC software. MAIN FEATURES AND FUNCTIONALITIES Voice alarm sound system configurable from 1 to 108 zones Independent controller for each zome Two dedicated recorded messages for each zone Monitored trigger contacts for alarm messages Continuous and independent monitoring of power amplifiers and loudspeaker lines, including ground fault No loudspeaker line termination is needed Initial calibration of loudspeaker lines and power amplifiers Spare amplifier connections on master and slave units Independent volume and tone control for each zone Independent volume and tone control for each audio program, spoken or recorded Background music input Up to 108 microphone station management. Each microphone station can be configured for voice alarm or for general announcements. Continuous monitoring of audio patch and mic. capsule on each microphone station Operation through 3 password protected access levels Manual silencing over each zone Internal events log list Dry contacts for system status monitoring Extension slots for future uses and system upgrades. TYPICAL APPLICATIONS Shopping malls Hospitals Railway stations Airports Museums Schools Stadiums Office buildings Pagina 5 di 16

WayGuard WG-MSU05 Master Unit WG-MSU05 front panel view 5 WG-MSU05 rear panel view 6 7 8 9 10 11 12 13 14 15 16 17 1. Graphic LCD display. 2. Navigation keyboars 3. Status LEDS: POWER indicates that the unit is powered, VOICE ALARM indicates that the system is forwarding a voice alarm messages, FAULT indicates there is a fault in some part of the equipment. 4. USB port for configuration download. 5. Zone module slots (WG-LMM01, WG-LRM01) 6. Monitored triggers for alarm messages activation 7. Dry contact indicates that the system is forwarding a voice alarm message. 8. Dry contact indicates that the system is forwarding a general announcement. 9. Slot dedicated to future uses 10. Ground connection 11. Dry contact inputs for power supply status reporting 12. Dry contact indicats a fault 13. Background music input 14. Bus 0 and Bus 1 to microphone stations 15. Connections to WG-ESU08 slave units 16. Spare amplifier connections 17. 24Vdc power input Pagina 6 di 16

WayGuard WG-MSU05 TECHNICAL SPECIFICATIONS : Steel enclosure, rack mountable with extensions slots on back panel IP protection according to EN 50102: IP30IK4 Dimensioni: Weight: User interface on front panel W:19 H: 2U D: 195,5mm 4,10 Kg 6x navigation keys, graphic 160x64 LCD display, 3x status leds USB Device port Power Input voltage Power: Power distribution +24Vdc (min 22Vdc, max 28Vdc) 2,64W (110mA @ 24Vdc) measurement condition: quiescent state, all slots empty, no mic station connected 2x 24Vdc bypass - max 1,5A on each microphone bus Modularity and extension slots Zone controllers Extension slots Extension ports 5x slots 1x slot general-purpose 2x RJ45 to WG-ESU08 units Audio inputs Microphone stations busses Background music inputs Digital audio player Balanced, 600 ohm, freq. fesponse 250 18.000Hz @-3dB, 2Vpk max, S/N >80dB RS485 databus +24V power supply, 1,5A max Stereo RCA, mixed to mono. Freq. response 60 18.000Hz, 1.8Vpk max signal.s/n S/N >80dB 12bit, 32Khz, storage files audio on Secure Digital card Audio paths management Architecture Volume control: Bass, mid, treble control 4 to 108 matrix arrangement -50dB 0dB -14dB +14dB Spare amplifier connection Description Automatic management and automatic switchover in case of main amplifier failures Continuous supervision Output to spare amplifier Balanced, transformer coupled, 600Ω 1.20Vrms, S/N >80dB, THD <1% Input from spare amplifier Spare amplifier monitoring 100V line, max power: 500Wrms analysis on 1 Khz tone burst Input triggers and dry contacts Player control (EVAC) Output dry contacts 2x inputs, with short circuit and cable-cut monitoring Busy (NC) Alarm (NO) Falul (NC/NO) Pagina 7 di 16

WayGuard WG-ESU08 Slave Unit WG-ESU08 front panel view WG-ESU08 rear panel view 2 3 4 5 6 1. Status LEDs: POWER indicates that the unit is powered, FAULT indicates there is a fault 2. Zone modules slots (WG-LMM01, WG-LRM01) 3. Ground connection 4. Chain connection from WG-MSU05 and to other WG-ESU08 units. 5. Spare amplifier connections 6. 24Vdc power inputs WG-ESU08 TECHNICAL SPECIFICATIONS Steel enclosure, rack mountable with extensions slots on back panel IP protection according to EN 50102: IP30IK4 Dimensions: Weight: User interface on front panel W:19 H: 2U D: 195,5mm 3,90 Kg 2x status leds Power Input voltage Power: +24Vdc (min 22Vdc, max 28Vdc) 1.3W (55mA @ 24Vdc) measurement condition: quiescent state, all slots empty, no mic station connected Modularity and extension slots Zone controllers 8x slots Spare amplifier connection Output to spare amplifier Balanced, transformer coupled, 600Ω 1.20Vrms, S/N >80dB, THD <1% Input from spare amplifier Spare amplifier monitoring 100V line, max power: 500Wrms analysis on 1Khz tone burst Output to spare amplifier Bilance, trans forme coupled, 600Ω 1.20Vrms, S/N >80dB, THD <1% Pagina 8 di 16

WayGuard WG-LMM01 Zone and Amplifier Controller WG-LMM01 connections view 1 2 1. LED BUSY : indicates the line is busy 2. LED FAULT : indicates a fault condition 3. Dry contact inputs; message triggers. Inputs have continuous monitoring against cable cut and cable short 4. Balanced output to power amplifier 5. 100V input from amplifier 6. 100V output to loudspeaker line 3 4 5 6 WG-LMM01 TECHNICAL SPECIFICATIONS Dimensions: Weight: Open frame mountable on WG-MSU05 o WG-ESU08. 85x35x125mm 0,18 Kg Zone amplifier management Description: Power The unit manages the zone amplifier and its loudspeaker line. In case of power amplifier 9alance, the unit calls for automatic switchover the spare 9alanced9, if installed. 0.72W (30mA @24Vdc) quiescent state Line output: Balanced transformer coupled, 600Ω 1.20Vrms, S/N >80dB, THD <1% Input from amplifier Amplifier monitoring 100V, max 500Wrms 18Khz tone burst, FFT analysis, 5% voltage tolerance from initial calibration Loudspeaker line Oputput Line monitoring 100V, max 500Wrms 18Khz tone burst, FFT analysis, 5% impedance tolerance PLAYER DIGITALE Digital audio player Onboard memory Player control (EVAC) 12bit, 32Khz, storage files audio on Secure Digital card Allows to store 2x 1 minute message 2x inputs, with short circuit and cable-cut monitoring Pagina 9 di 16

WayGuard WG-LRM01 Zone B Controller WG-LRM01 connections view 1 2 1. LED BUSY : indicates the line is busy 2. LED FAULT : indicates a falult on the line 3. 100V input from mani amplifier 4. 100V output to loudspeaker line 3 4 WG-LMM01 TECHNICAL SPECIFICATIONS Dimensions: Weight: Open frame mountable on WG-MSU05 o WG-ESU08. 85x35x125mm 0,11 Kg Line B management (matched to WG-LMM01) Description Power The unit performs the monitoring of the B line and has to be marched to the WG-LMM01 module, sharing the same power amplifier. 0.67W (30mA @24Vdc) quiescent state Loudspeaker line Oputput Line monitoring 100V, max 500Wrms 18Khz tone burst, FFT analysis, 5% impedance tolerance Pagina 10 di 16

WayGuard WG-MTU01 WG-MTU01 WG-MTU10 Microphone Stations Connections view, common to all models 1. Bus connection to WG-MSU05 2. Auxiliary 24V power input (not for emergengy mic stations) 2 1 1. Status LEDs 2. Push to talk button WG-MTU01 top panel view 1. Status LEDs 2. Push to talk button 3. Configurable keyboard WG-MTU06 top panel view 1. Status LEDs 2. Quick select message keys 3. LCD graphic display 4. Push to talk button 5. Configurable dial keyboard 6. Clear key 7. Background music key WG-MTU10 top panel view Pagina 11 di 16

WayGuard WG-MTU01 TECHNICAL SPECIFICATIONS Powder coated chassis, brushed and anodized aluminium top panel. EN 50102 IP protection class: IP31IK4 Dimensions Weight: Description Frequency response: Power Connection Microphtone capsule monitoring User interface 140x190x50mm gooseneck length 330mm 1,05 Kg Emergency or general announcement microphone station, embedded audio compressor, continous minitoring of microphone capusle with fault reporting 250Hz 12Khz @ -3dB S/N >80dB 1,2W (50mA @ 24Vdc) quiescent condition RJ45 plug to WG-MSU05. Monitored audio and data paths Short circuit open circuit 1x pushbutton key 2x leds WG-MTU06 TECHNICAL SPECIFICATIONS Powder coated chassis, brushed and anodized aluminium top panel. EN 50102 IP protection class: IP31IK4 Dimensions Weight: Description Frequency response: Power Connection Microphtone capsule monitoring User interface 225x190x50mm gooseneck length 330mm 1,35 Kg Emergency or general announcement microphone station, embedded audio compressor, continous minitoring of microphone capusle with fault reporting 250Hz 12Khz @ -3dB S/N >80dB 1,2W (50mA @ 24Vdc) quiescent condition RJ45 plug to WG-MSU05. Monitored audio and data paths Short circuit open circuit 7x pushbutton keys 16x leds Pagina 12 di 16

WayGuard WG-MTU10 TECHNICAL SPECIFICATIONS Powder coated chassis, brushed and anodized aluminium top panel. EN 50102 IP protection class: IP31IK4 Dimensions Weight: Description Frequency response: Power Connection Microphtone capsule monitoring User interface 240x190x50mm gooseneck length 330mm 1,45 Kg Emergency or general announcement microphone station, embedded audio compressor, continous minitoring of microphone capusle with fault reporting 250Hz 12Khz @ -3dB S/N >80dB 1,2W (50mA @ 24Vdc) quiescent condition RJ45 plug to WG-MSU05. Monitored audio and data paths Short circuit open circuit 16x pushbutton keys 6x leds graphic 160x64 LCD display Pagina 13 di 16

WayGuard WG-DPA241 WG-DPA501 WG-DPA242 WG-DPA124 Power Amplifiers Series 1. Channel volume control 2. Signal indicator 3. Clip Indicator 4. Protection indicator 5. Power switch 6. Power indicator WG-DPAxx series front panel, common to all model except nr of channels 7. Mains power input 8. 24V input (one for each channel) 9. Cooling fan 10. Loudspeaker 100V output 11. Balanced input 12. RJ45 reserved for future use WG-DPAxx series frear panel, common to all model except nr of channels WG DPA241 TECHNICAL SPECIFICATIONS Rated output power Loudspeaker output Input sensitivity Input impedance Frequency response S/N ratio Controls Indicators Protection Power consmption Power supply dimensions Weight Single channel 240W power amplifier 240W rms 100V line +/- 385mV balanced input 20 Kohm 80Hz 18Khz (+1dB, -3dB) >85dB Volume control on front panel Power, signal presence, overload, protection High temp, overload, short circuit 248W 220Vac 50Hz ; 24Vdc 484x380mm; 1U 3,8Kg Powder coated chassis, brushed and anodized aluminium front panel. EN 50102 IP protection class: IP31IK4 Pagina 14 di 16

WayGuard WG DPA501 TECHNICAL SPECIFICATIONS Rated output power Loudspeaker output Input sensitivity Input impedance Frequency response S/N ratio Controls Indicators Protection Power consmption Power supply dimensions Weight Single channel 500W power amplifier 500W rms 100V line +/- 385mV balanced input 20 Kohm 80Hz 18Khz (+1dB, -3dB) >85dB Volume control on front panel Power, signal presence, overload, protection High temp, overload, short circuit 515W 220Vac 50Hz ; 24Vdc 484x380mm; 1U 3,8Kg Powder coated chassis, brushed and anodized aluminium front panel. EN 50102 IP protection class: IP31IK4 WG DPA242 TECHNICALSPECIFICATIONS Rated output power Loudspeaker output Input sensitivity Input impedance Frequency response S/N ratio Controls Indicators Protection Power consmption Power supply dimensions Weight Twin channel 240W power amplifier 2x240W rms 100V line +/- 385mV balanced input 20 Kohm 80Hz 18Khz (+1dB, -3dB) >85dB Volume control on front panel Power, signal presence, overload, protection High temp, overload, short circuit 492W 220Vac 50Hz ; 24Vdc 484x380mm; 1U 5,6Kg Powder coated chassis, brushed and anodized aluminium front panel. EN 50102 IP protection class: IP31IK4 Pagina 15 di 16

WayGuard WG DPA124 TECHNICALSPECIFICATIONS Rated output power Loudspeaker output Input sensitivity Input impedance Frequency response S/N ratio Controls Indicators Protection Power consmption Power supply dimensions Weight Quad channel 240W power amplifier 4x120W rms 100V line +/- 385mV balanced input 20 Kohm 80Hz 18Khz (+1dB, -3dB) >85dB Volume control on front panel Power, signal presence, overload, protection High temp, overload, short circuit 576W 220Vac 50Hz ; 24Vdc 484x380mm; 1U 8,5Kg Powder coated chassis, brushed and anodized aluminium front panel. EN 50102 IP protection class: IP31IK4 Pagina 16 di 16