DIVISION II SUB-DRAINS SECTION 02712

Similar documents
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

SECTION EARTH MOVING

Section SEWER PIPE INSTALLATION AND TESTING

LS 2540 SEWER LATERALS AND INSPECTION TEES

SECTION PRECAST CONCRETE UTILITY STRUCTURES

DIVISION I GENERAL REQUIREMENTS SECTION 01005

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Section 2100-Trenching and Tunneling

SECTION STORM DRAIN SYSTEM

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

SECTION STORM DRAINAGE SYSTEM

SECTION G SEWERS (STORM, SANITARY AND FDC)

Beacon Hill Sewer District Standard Specifications

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

SECTION STORM DRAINAGE TABLE OF CONTENTS

Section 402. STORM SEWERS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

CLEANING, INSPECTION, AND TESTING OF SEWERS

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

The Manitoba Water Services Board SECTION Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

DIVISION 4300 STORM DRAINAGE

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

Specification Guidelines: Allan Block Modular Retaining Wall Systems

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 7- STORM SEWER

City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

CONSTRUCTION PERMIT REQUIREMENTS

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

SECTION EXCAVATION, TRENCHING AND BACKFILLING (Pipeline Construction)

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

Stormwater/Wetland Pond Construction Inspection Checklist

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

SECTION BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

8.01 STORM SEWERS, CATCH BASIN LEADS, AND EXTENSIONS

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System

Town of Greenville Policy

SECTION 724 PIPE CULVERTS

OAR52 A-1 (September, 1981)

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

DESCRIPTION OF WORK:

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

STANDARD SPECIFICATIONS FOR STORM SEWER CONSTRUCTION CITY OF PLYMOUTH, MINNESOTA

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

INSTALLATION OF INSITUFORM LINER

900 SEWERAGE WORK ITEM PIPE SEWERS COMPLETE IN PLACE

CHAPTER 5. Storm Sewer

PVC PIPE PERFORMANCE FACTORS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

THE CORPORATION OF THE CITY OF GUELPH. THEREFORE the council of the Corporation of the City of Guelph enacts as follows:

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Site Grading and Drainage to Achieve High-Performance Basements

SECTION 9. All sewer laterals shall tie into the sewer main lines unless approved by the City Engineer.

Specifications for Residential Property Owners Connection to New Public Sewer

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

Wastewater Capital Projects Management Standard Construction Specification

How To Retaining Wall Guide

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18

Part 9 SUBDRAIN DESIGN AND LAYOUT

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal

STORM DRAIN DESIGN AND CONSTRUCTION STANDARDS & SPECIFICATIONS 400 SERIES

Permeable Pavement Construction Guide

ROAD OPENING LICENCE APPLICATION FORM PLEASE READ ALL PARTS AND SECTIONS OF THIS FORM IN ADVANCE OF COMPLETING THE APPLICATION

INSTALLATION SPECIFICATIONS FOR AQUAPERM TM PAVER

Transcription:

Subdivision Requirements Manual Page 1 of 5 PART I - GENERAL 1.1 Related Work.1 Rough Grading : Section 02211 1.2 Scope of Work.1 This section covers the supply and installation of sub-drainage piping including services and fittings, trenching, bedding and backfilling as indicated on the drawings as well as flushing and testing..2 Coordinate work in this section with work in all other sections. 1.3 Guarantee.1 The contractor shall guarantee all material and workmanship for a period of two years from the date of Preliminary Acceptance by the City. PART II - PRODUCTS 2.1 Materials.1 Backfill :.1 19 mm clear stone to OPSS 1004 to be used as backfill and compacted to 98% SPD. Insure drainage tile is not crushed when installing backfill..2 The use of any bedding material or backfill material with diameter larger than 40 mm will not be permitted around any flexible pipe..2 Surface :.1 Mississauga playground sand will be used where sand cover is required as per approved drawings. Refer to Section 02861 PART II - PRODUCTS 2.1.2 Areas to be sodded shall have 150 mm topsoil placed prior to sodding..3 Piping :.1 Sub-drainage piping shall be 100 mm diameter filter wrapped perforated corrugated plastic drainage pipe manufactured for sub-surface land use..2 Pipe material shall be resistant to chemicals present in soils and ground water, and shall be resistant to

Subdivision Requirements Manual Page 2 of 5 deterioration from ultraviolet light..3 Tubing must be of uniform colour and density, free from any defects..4 100 mm tubing must have an internal diameter of 99.56-106.68 mm. Minimum water-inlet area must be 15.7 cm 2 /m in length..5 Individual inlet openings must have an opening ranging from 1-2 mm and should be arranged in a minimum of 3 rows, uniformly spaced around the circumference of the tubing..6 100 mm tubing shall have a minimum stiffness of 138 Pa at 5% deflection when tested in a parallel plate. There should be no evidence of a crack or split following an impact test..7 At any change of direction, use manufactured bends and fittings..8 All ends to be capped with manufactured caps..9 Drainage tiles emptying to swales shall be trimmed and fitted with rodent guard and 1 metre sleeve of 150 mm dia.pipe of the specified material. PART III - EXECUTION 3.1 Notification of Utilities.1 Contractor must obtain stakeouts from all utilities concerned and must obtain all permits with regard to this installation. 3.2 Inspection.1 All materials shall be inspected by the contractor for damage in transit. No defective material shall be delivered to the site. Any material subsequently damaged shall be removed from the site immediately..2 The contractor may be ordered by the Community Services Department to have pipe and fittings inspected by an accredited inspection company before being delivered to the site, and stamped with their approved mark on each piece.

Subdivision Requirements Manual Page 3 of 5.3 The Community Services Department may order tests of any material delivered to the site and may reject materials pending the result of tests..4 Any material found to be defective in manufacture, or damaged before or after acceptance from the carrier, will be rejected by the Community Services Department and the contractor shall promptly remove such defective material from the site. 3.3 Trenching.1 After completing all rough grading, excavate trenches using a method approved by the Community Services representative. Trenches to have smooth bottoms with excavated material to be deposited away from the trench..2 All trenches are to be excavated starting from the lowest elevation at the outlet and proceeding up grade..3 Maximum spacing between trenches to be 12.5 m centre to centre or as shown on approved Layout and Grading drawings..4 All excavated material is to be removed from the area. 3.4 De-watering.1 Keep excavations dry while work is in progress..2 Dispose of water in a manner not detrimental to public health, environment, public and private property, or any portion of work completed or under construction. 3.5 Excavation.1 Excavate to lines, grades, elevations and dimensions indicated on drawings or as directed in the field..2 Notify the consultant when soil at proposed elevation of trench bottom appears unsuitable for foundation of installation..3 Remove unsuitable material from trench bottom to extend to a depth directed by Community Services..4 Unless otherwise authorized by Community Services in writing, do not excavate more than 30 m of trench in advance of installation operations and do not leave trench open at end of day's operation..5 Dispose of surplus and unsuitable excavated material off site.

Subdivision Requirements Manual Page 4 of 5.6 Do not obstruct flow of surface drainage. 3.6 Backfilling.1 Do not proceed with trench backfilling operations until Community Services has inspected and approved installations..2 Use approved backfill material as indicated or directed..3 Backfilling around installations :.1 Place bedding and surround material as noted on drawings..2 Place layers simultaneously on both sides of installed work to equalize loading..3 Place material by hand under, around and over installations until 150 mm of cover is provided. Dumping material directly on installations will not be permitted..4 Do not place backfill in freezing weather without written permission of Community Services..5 Compact granular backfill material to a minimum 95% of Standard Proctor Maximum Dry Density (ASTM D698-78)..6 Compact using approved mechanical tamping devices, or by hand tamping to achieve specified compaction. 3.7 Trench Bottom.1 Where required due to removal of unsuitable material or Preparation unauthorized over-excavation, bring bottom of excavation to design grade with approved material..2 Compact trench bottom to density at least equal to density of adjacent surrounding soil. 3.8 Installation.1 Excavations require inspection and approval prior to Inspection commencement of installation operations. 3.9 Bedding.1 Place 150 mm layer of bedding material to full trench width as indicated and compact to minimum 95% of Standard Proctor Maximum Dry Density ASTM D698-78.

Subdivision Requirements Manual Page 5 of 5 3.10 Installation.1 Lay drains on prepared bed, true to line and grade with inverts smooth and free of sags or high points. Ensure barrel of pipe is in contact with the bed throughout..2 Commence laying at outlet and proceed in upstream direction..3 Make joints tight in accordance with manufacturer's instructions..4 Do not allow water to flow through pipes during construction except as approved..5 Make water tight connections to existing drains, new or existing manholes, and catch basins where indicated or as directed..6 Plug open upstream ends of pipes with water tight manufactured end caps..7 Backfill with granular material and sand base as directed..8 Protect sub-drains against flotation during installation. 3.11 Connections to.1 Connect sub-drains to municipal storm sewer system where Municipal Facilities indicated. Receive approval prior to backfilling. 3.12 Restoration.1 Clean and reinstate areas affected by work to satisfaction of the Community Services Department. 3.13 Flushing.1 Prior to inspection for final approval the contractor shall flush and thoroughly clean all sewers. The contractor shall provide all equipment and water required for this operation. END OF SECTION 02712