Motor Starters CONTROLS. Features:

Similar documents
8146/5 Series Breaker Panelboards

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Control and Distribution Boxes made of Stainless Steel Series 8150

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Plug and Socket Devices SolConeX 16 A Series 8570

Linear Luminaire with LED Series EXLUX 6402/2

Worcester DS/DM Series UltraSwitch Switch box

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

B-Series Temperature Switches

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Plug and Socket Devices CES 63 A Series 8579

ConSig 8040 Series CONTROLS Features:

Explosion-Proof Electric Unit Heaters

Terminal Boxes Series 8146

EDS / EFS Series Control Stations

WE-350 Series ¼ Turn Electric Actuator

EDS / EFS Series Control Stations

Operating Instructions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

MCC Ratings. Voltage Rating

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

B-Series Switches Pressure, Differential Pressure & Hydraulic

Explosion proof enclosures

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Bolted contact switches. Pringle switches

Compact pressure switch Flameproof enclosure Ex d Model PCA

Solenoid Valve Island Type 3965

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Flameproof Audible Signal 115 db (A) Series YA90

Low Voltage Fuses For Motor Protection

Know-how makes the difference. Electrical Actuators

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

Terminal Box. Specifications TNCN

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Scraper Passage Indicator. Electrical Indicator. Features

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

distributing & controlling system solutions

Floodlight Range Installation Guide

GUE, GUB Junction Boxes

Electronic, Digital and Mechanical Vibration Switches

PSR The compact range Description

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Technical Specifications

9 Control Equipment. Control Button Series 8082

Installation Manual Version 7.3 IMPORTANT:

FLB Series Circuit Breakers and Enclosures

Plugs and Receptacles

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.12. page Products for Explosion hazardous Environment

TorqPlus TM Electric Valve Actuators and Controls

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

EX-PROOF PTZ DAY/NIGHT CAMERA FOR HIGHLY CORROSIVE ENVIRONMENTS MPX

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

IRRIGATION PUMPING Table of Contents - Section 900

Catalog January. Heavy industrial power applications Motor contactors and starters

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Generator DoCKInG StatIonS

IECEx Certificate of Conformity

Rugged & Reliable Power Connections

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Advantium 2 Plus Alarm

Cable/Conduit Conversion

Safety instructions VEGADIS DIS81.CEIA/V****

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Motor Circuit Protection Tables

CMP PRODUCTS. Ex d / Ex e / Ex nr CABLE GLANDS AND CONNECTORS. Triple Certified.

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

PowerFlex 700 and 700H Packaged Drives. Technical Data

Water Leak Detection System

Technical Data. Dimensions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Centro-Matic Automatic Lubrication Systems System Controls

, User s Manual

Failure code manual. content

Technical Information RIA14

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Safe switching and monitoring Solenoid Interlocks

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Overload Relay Heater Tables

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Transcription:

Motor Starters CONTROLS Features: Enclosures made of stainless steel for excellent corrosion resistance Class I, Division 2, Class I, Zone 1 certified designs Attractive space efficient design Up to 70% labor savings costs compared to explosion proof models Up to 70% less weight compared to explosion proof models No Conduit Seals Required Available as Combination Starter Manual Starter Reversing Starter Across the Line Starter Globally Certified* One part number provides Class I Division 2, AEx, ATEX, and IECEx certifications A variety of pushbuttons, control switches, and pilot lights available to customize your solution *8150 models only INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

CONTROLS Motor Starters CLASSIFICATIONS 7150/5- Fused Disconnects Class I, Division 2, Groups A,B,C,D T4 Enclosure 3, 4, 4x, IP 66 CEC- Class I, Division 2, Groups A,B,C,D T4 Enclosure type 3,4,4x; IP 66 File No. 3050071 Ambient Temperature Range 20 C ( 4 F) Min. CLASSIFICATIONS 8150/5-* Nonfused 8006 HP Rated Switching Device NEC- Class I, Zone 1 AEx de IIC T* Gb Class I, Division 2, Groups A,B,C,D Class II, Divisions 1 and 2, Groups E,F,G Enclosure 3, 4, 4x, IP 66 CEC- Class I, Zone 1 Ex de IIC T* Gb Class I, Division 2, Groups A,B,C,D Class II, Division 1 Groups E,F,G Enclosure type 3,4,4x; IP 66 File No. 3050071 Ex de IIC T* Gb Ex tb IIIC T* IECEx- PTB 09.0049 ATEX- Ex II 2G Ex de IIC T* Gb Ex II 2D Ex tb IIIC T* PTB 09 ATEX 1109 Ambient Temperature Range for 16A T6 20 C ( 4 F) Min. Ambient Temperature Range for 25A-125A T5 40 C ( 40 F) Min. Manual Motor Starter (Without Overload Protection) Unique Advantages: Horse power rated switching device Available with FRP enclosure ** Multi-level switching up to 12 pole ** Ability to control multiple motors ** Consult factory for multiple motor de-ratings requirements and additional HP ratings ** Consult Factory Technical Data 16 AMP. 25 AMP. RATED VOLTAGE AC 600 600 RATED VOLTAGE DC 220 125 600VAC 10 15 480VAX 10 15 240VAC 5 7.5 HORSE POWER 120VAC 2 3 60VDC - - 125VDC - 3(2) * 240VDC - 5(3) * TERMINALS AWG 12 8 STRANDED (mm 2 ) 1.5 10 BACK-UP FUSE (Required) Class J 20 MAX 40 MAX *The numbers within brackets indicate how many switch contacts need to be wired in series to achieve the indicated horsepower ratings in DC application. 2

Motor Starters CONTROLS Catalog Number & Description A B C D E F 8150/5-037-05-100-000-00 176 (6.9 ) 236 (9.3 ) 150 (5.9 ) 196 (7.7 ) 212 (8.3 ) 228 (9 ) 10HP, 16A @ 480V 8150/5-037-05-150-000-00 176 (6.9 ) 236 (9.3 ) 150 (5.9 ) 196 (7.7 ) 212 (8.3 ) 228 (9 ) 15HP, 25A @ 480 3

CONTROLS Motor Starters Applications: Combination and non-combination motor starters are used in areas where hazardous materials are processed, handled or stored. These units provide disconnecting means, circuit protection, and motor running protection. For general motor control and circuit protection indoors and outdoors in damp, wet, dirty, dusty hazardous locations without the need for a protective shelter In areas where frequent washdowns are necessary or where heavy rain or water spray is prevalent For across-the-line starting, stopping, and reversing of polyphase AC induction motors To provide line disconnect means and short circuit protection To provide motor overload and short circuit protection For service entrance, feeder or branch circuit protection for lighting, heating, appliance and motor circuits 316L STAINLESS STEEL ENCLOSURE RATED FOR NEMA 4X & IP66 LED PILOT LIGHT (MULTI-COLOR LENSES) INTERLOCKED PAD LOCKABLE EXTERNAL ACTUATOR PUSHBUTTONS AND SELECTOR SWITCHES CAM-LOCK 1/4 TURN LATCHES 4

Motor Starters CONTROLS Features: Motor Starter Component Ex Certification: 8523 series Motor Circuit Protectors and 8510 series Contactor are engineered, designed and manufactured as explosion protected components certified for ATEX / IECEx Zone 1, and Class I, Division 2. Enhanced Corrosion Resistance: 7150/8150 series enclosures are constructed of 316L stainless steel which are NEMA 4X and IP66 for better corrosion protection in offshore saltwater and petrochemical environments. Available up to 15 HP at 480 VAC and up to 20 HP at 600 VAC. 70% Labor Cost Savings: 7150 / 8150 motor starters come prewired from factory and the only field installation required is the termination of load & line side cables to the provided power terminal blocks. Enclosure openings can be punched in the field or come factory pre-punched. No sealing fittings are required at the enclosure resulting in significant labor savings. Up to 70% Less Weight : Up to 70% lower weight for ease of installation compared to explosion proof cast aluminum enclosures. Cam-Lock fasteners can be unlatched with quarter turn versus multi turn bolts. Ease of Maintenance: 7150 / 8150 series 316L stainless steel cover comes standard with two hinges and two Cam- Lock fasteners as opposed to up to 22 bolts fasteners. External Actuators: Can be pad-lockable in ON or OFF position CONTROL TRANSFORMER FUSE HOLDERS MOTOR CIRCUIT PROTECTOR (EXPLOSION PROTECTED) INCREASED SAFETY TERMINAL BLOCKS FOR POWER AND CONTROL CIRCUITS (EASY TO WIRE) CONTACTOR (EXPLOSION PROTECTED) PRE-WIRED (SIMPLY CONNECT INCOMING AND OUTGOING WIRES TO THE TERMINALS) 5

CONTROLS Motor Starters Catalog Construction Logic CLASSIFICATIONS 7150/5 Series NEC- Class I, Division 2 Groups B, C, D Class II, Division 2 Groups F, G Class III Enclosure Type 3, 4, 4X; IP66 CEC- Class I, Division 2 Groups B, C, D Class II, Division 2 Groups F, G Class III Enclosure Type 3, 4, 4X; IP66 Ambient Temperature Range: 20 C ( 4 F) Min. Consult Factory for lower Temp (-40 C) CLASSIFICATIONS 8150/5 Series NEC- Class I, Zone 1 AEx de IIC T4 Gb Class I, Division 2 Groups B, C, D Class II, Division 2 Groups F, G Class III Enclosure Type 3, 4, 4X; IP66 CEC- Class I, Zone 1 Ex de IIC T4 Gb Class I, Division 2 Groups B, C, D Class II, Division 2 Groups F, G Class III Enclosure Type 3, 4, 4X; IP66 II 2G Ex de IIC T6 PTB 09 ATEX 1109 II 2D Ex td A21 IP66, T80 C IECEx Ex de IIC T6 Ex td A21 IP66 T80 C IECEx PTB 06.0090 Ambient Temperature Range: 20 C ( 4 F) Min. Consult Factory for lower Temp (-40 C) a 150 / 5 - K03702 bb ccc ddd ee ff* Version a bb ccc ddd ee ff* ** List All That Apply 150 / 5 - K03702 Version Motor Starter Starter Size Control Voltage Entries Options 7 = Class I, Division 2 8 = Class I, Zone 1 Global Certification AEx, ATEX / IECEx, Class I, Div. 2 Motor Starter Type 01 = Across the Line (DOL) 02 = Combination 03 = Reversing 04 = Manual 05 = Fuse Combination 7150 Series Only Starter Size (based on 480 VAC) 050 = 5.0 hp 075 = 7.5 hp 100 = 10.0 hp 150 = 15.0 hp 999 = According to Specification Control Voltage 024 = 24 VAC 120 = 120 VAC 240 = 240 VAC 999 = According to Specification 000 = None (manual starter) Entries 00 = No Entries 01 = Plugged Holes 02 = Conduit Hubs 03 = Armored Cable Glands 04 = Unarmored Cable Glands Options Z1CVT055 = 55VA (480/120) control transformer, 8150 only Z1CVT075 = 75VA (480/120) control transformer, 8150 only Z1CVT115 = 115VA (480/120) control transformer, 8150 only Z1CVT150 =150VA (480/120) control transformer, 8150 only Z1CVT200 = 200VA (480/120) control transformer, 8150 only CVT075 = 75VA (480/120) control transformer, 7150 only CVT100 = 100VA (480/120) control transformer, 7150 only CVT150 = 150VA (480/120) control transformer, 7150 only CVT200 = 200VA (480/120) control transformer, 7150 only S273 = Hand-Off-Auto switch S052 = On-Off switch U231 = Start-Stop button PLA = Pilot Light Amber PLG = Pilot Light Green PLR = Pilot Light Red AM = Ammeter HTR50 = 50W Space Heater, 7150 Only HTR80 = 80W Space Heater, 7150 Only Z1HTR50 = 50W space heater, built suitable to Class I, Zone 1 Z1HTR80 = 80W space heater, built suitable to Class I, Zone 1 BD55 = Breather/Drain (IP55) BD66 = Breather/Drain (IP66) 6

Motor Starters CONTROLS ACROSS THE LINE STARTER COMBINATION STARTER 7

CONTROLS Motor Starters FUSED COMBINATION STARTER OR REVERSING STARTER MANUAL MOTOR STARTER 8