MINIATURE CIRCUIT BREAKERS LST UP TO 125 A (10 ka)

Similar documents
Electronic overload relay EF19 and EF45

R.C.C.B. s two-pole LEXIC

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Type: DILM32 10(24V50HZ) Article No.:

Electronic overload relay EF65, EF96 and EF146

Type: DILM50(230V50HZ,240V60HZ) Article No.:

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

5SV Residual Current Protective Devices

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: DILM9 10(24VDC) Article No.:

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

48 SERIES Relay interface modules 10 A

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

HERZ-Thermal Actuators

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

38 Series - Relay interface modules A

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MasterINTERFACE 39 Series - Relay interface modules

RM4TG20 three-phase network control relay RM4-T - range V

E-STOP relays, safety gate monitors

49 Series - Relay interface modules A. Features

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Product and functional description

Contact expansion modules

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

MasterINTERFACE 39 Series - Relay interface modules

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermal-Magnetic Circuit Breaker M1-..

Quick Connect. quick - simple - efficient.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Contact expander modules

Digital input modules

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Safety technique. Emergency stop module BO 5988 safemaster

Vario-Series Accessories

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

System pro M compact Miniature Circuit Breaker S 200/S 200 M

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

SURGE PROTECTIVE DEVICES

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

The complete range of consumer switchboards and switchgear

RY2 miniature industrial relays

How To Build A Low Voltage Capacitor Lvcp

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Manual motor starter MS116

Low Voltage Products. Switches Automatic Transfer Switches

Cable Plug acc. to DIN EN , Form A

PHOENIX CONTACT Features

PSR The compact range Description

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

E-STOP relays, safety gate monitors

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Manual Motor Starter MS 116 up to 16 A Technical Data

Unified requirements for systems with voltages above 1 kv up to 15 kv

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Emergency lighting units EM powerled

PNOZsigma - Base units

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technicaldata General

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Plug and Socket Devices CES 63 A Series 8579

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Thermistor motor protection

Maximum Demand Control

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

ADM1TE 5/30A DIN rail single phase two wire energy meter

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Control Devices Catalogue. Control Devices. Preferred and Standard Products

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Transcription:

MINIATURE CIRCUIT BREAKERS LST UP TO 2 A (0 ka) For building, commercial and industrial installations up to 2 A 230/400 V a.c. and 440 V d.c. For cable and conductor overload and short-circuit protection Tripping characteristics B, C, D according to EN 0 898 Optical position indicator - indicates ON/OFF position Colours of control levers in accordance with the colours of fuses with screw base Wide range of accessories auxiliary switches, undervoltage releases and shunt trips, busbars Possibility of testing the tripping mechanism function by insertion of a pin in the hole designated TEST on the front panel of the device Rated short-circuit breaking capacity I cn = 0 ka to achieve higher I cn (to 20 ka), it is recommended to use cylindrical fuse-links PV in fuse switch-disconnectors OPV mounted on DIN rail before the miniature circuit breaker Possible sealing in OFF or ON position Miniature circuit breakers -pole Characteristic B Characteristic C Characteristic D Weight Packing [A] Type Product code Type Product code Type Product code [kg] [pcs] 40 LST 40B/ 2004 LST 40C/ 2024 LST 40D/ 2044 0.2 3 0 LST 0B/ 200 LST 0C/ 202 LST 0D/ 204 0.2 3 3 LST 3B/ 200 LST 3C/ 202 LST 3D/ 204 0.2 3 80 LST 80B/ 2007 LST 80C/ 2027 LST 80D/ 2047 0.2 3 00 LST 00B/ 2008 LST 00C/ 2028 LST 00D/ 2048 0.2 3 2 LST 2B/ 2009 LST 2C/ 2029 LST 2D/ 2049 0.2 3 Miniature circuit breakers 3-pole Characteristic B Characteristic C Characteristic D Weight Packing [A] Type Product code Type Product code Type Product code [kg] [pcs] 40 LST 40B/3 2 LST 40C/3 224 LST 40D/3 234 0.3 0 LST 0B/3 2 LST 0C/3 22 LST 0D/3 23 0.3 3 LST 3B/3 2 LST 3C/3 22 LST 3D/3 23 0.3 80 LST 80B/3 27 LST 80C/3 227 LST 80D/3 237 0.3 00 LST 00B/3 28 LST 00C/3 228 LST 00D/3 238 0.3 2 LST 2B/3 29 LST 2C/3 229 LST 2D/3 239 0.3 Miniature circuit breakers 3+N-pole Characteristic B Characteristic C Characteristic D Weight Packing [A] Type Product code Type Product code Type Product code [kg] [pcs] 40 LST 40B/3N 24 LST 40C/3N 24 LST 40D/3N 2 0.84 0 LST 0B/3N 2 LST 0C/3N 2 LST 0D/3N 2 0.84 3 LST 3B/3N 2 LST 3C/3N 2 LST 3D/3N 2 0.84 80 LST 80B/3N 27 LST 80C/3N 27 LST 80D/3N 27 0.84 00 LST 00B/3N 28 LST 00C/3N 28 LST 00D/3N 28 0.84 2 LST 2B/3N 29 LST 2C/3N 29 LST 2D/3N 29 0.84 DC miniature circuit breakers 2-pole Characteristic C Weight Packing [A] Type Product code [kg] [pcs] 80 LST-DC 80C/2 207 0.42 00 LST-DC 00C/2 208 0.42 2 LST-DC 2C/2 209 0.42 LST accessories Auxiliary switches S-LSN, S-LSN2 page 9 Shunt trips V...-LSN page 2 Undervoltage releases N...-LSN page 23 Interconnecting busbars S-3L page 93 Connecting adapters AS-AL/Cu--0, CS-FH000..., N3x0-FH000 page 9

MINIATURE CIRCUIT BREAKERS LST UP TO 2 A (0 ka) Description Control lever colour unambiguously indicates the rated current of the device (the control lever colours are in accordance with the colours of fuses with screw base) [A] Colour 40 (black) 0 (white) 3 (copper) 80 (silver) 00 (red) 2 (yellow) Position indicator indicates optically the operating status of the device. Indicator colour Device status (red) (green) ON OFF Test push-button for check of the tripping mechanism function. Lower latch enables mounting on the rail DIN EN 0 022, width 3 mm. In the fixed withdrawn position it facilitates the side shift on the instrument board. Specification Type LST LST-DC Standards EN 0 898 EN 0 898 Approval marks Number of poles, 3, 3+N 2 Tripping characteristics B, C, D C Rated current 40 2 A 80, 00, 2 A Rated operating voltage U e 230/400 V a.c. / 48 V d.c. 440 V d.c. Max. operating voltage U max 23/440 V a.c. / 2 V d.c. 484 V d.c. Min. operating voltage U min 2 V a.c. / d.c. 2 V d.c. Rated frequency f n 40 0 Hz - Rated short-circuit breaking capacity (EN 0 898) I cn 0 ka - Rated short-circuit service breaking capacity (EN 0 947-2) I CS =00% I CU - 0 ka (τ ms) Endurance 0 000 operating cycles 0 000 operating cycles Rated impulse withstand voltage (.2/0 µs) U imp kv kv Overvoltage category (IEC 4- IV IV Mounting on the rail DIN EN 0 022 - width 3 mm 3 mm Degree of protection IP20 IP20 Connection Cu conductor - rigid (solid, stranded), flexible. 0 mm 2, 2x mm 2. 0 mm 2, 2x mm 2 tightening torque 3. Nm 3. Nm opposite yes yes Operating conditions ambient temperature -20 + C -20 + C operating position arbitrary arbitrary seismic immunity (8 0 Hz) g g Internal impedance Z, power losses P, impedance Z s [A] Z [mω/pól] P [VA/pól] Max. impedance of fault loop Z s [Ω] 2) Characteristic B Characteristic C Characteristic D 40 2.3 3.9. 0.4 0.3 0.73 4.32 0.93 0. 0.28 3.42.3 0.73 0.40 0.23 80 0.9.79 0.7 0.32 0.8 00 0.80 8.03 0.4 0.2 0. 2 0. 9.4 0.3 0.20 0. Mean values 2) For TN network, U = 230 V, break time up to 0.4 s; if the measured value exceeds the table value, use residual current circuit breaker 2

MINIATURE CIRCUIT BREAKERS LST UP TO 2 A (0 ka) Correction of rated currents of miniature circuit breakers LST Correction of rated currents for ambient temperature -20 C to +0 C [A] [A] -20 C -0 C 0 C 0 C 20 C 30 C 40 C 0 C 0 C 40 0.0 48.0 48.0 4.0 44.0 40 37.2 3.2 33. 0 2. 0.0 0.0 7..0 0 4. 44.0 42.0 3 78.8 7. 7. 72. 9.3 3 8..4 2.9 80 04.0 00.0 9.0 92.0 88.0 80 74.4 70.4 7.2 00 30.0 2.0 20.0.0 0.0 00 93.0 88.0 84.0 2 2..3 0.0 3.8 37. 2.3 0.0 0.0 Valid for pole and any characteristic, reference temperature: 30 C Correction of rated currents of miniature circuit breakers installed side by side [A] 2) 2 3 4 40 38.00 37.00 3.00 3.20 0 47.0 4.2 4.00 44.00 3 9.8 8.28.70.44 80 7.00 74.00 72.00 70.40 00 9.00 92.0 90.00 88.00 2 8.7.3 2.0 0.00 2) Valid for reference temperature 30 C Dimensions LST.../ LST-DC.../2 LST.../3 LST.../3N 7..7 4 90 2. 3.2 79.8 0.4. 44 0 70 74 Diagram LST.../ LST.../3 LST.../3N LST-DC.../2 3 3 N 3 2 2 4 2 4 N2 2 4 Protection of DC circuits It is possible to use both LST and LST-DC miniature circuit breakers for protection of DC circuits depending on voltage. For voltage U n up to: 48 V d.c. use miniature circuit breakers LST.../. Source poles (+) and (-) can be connected to the circuit breaker terminals arbitrarily. 440 V d.c. use miniature circuit breakers LST-DC.../2. As these miniature circuit breakers are equipped with permanent magnets, source poles (+) and (-) must be connected to identically marked terminals of the circuit breakers (see connection example). 440 V d.c. LST-DC.../2 2 3 4 3

MINIATURE CIRCUIT BREAKERS LST UP TO 2 A (0 ka) Tripping characteristics Characteristic B: for protection of electric circuits with equipment that does not cause current surges (lighting or socket outlet circuits etc.); the short-circuit release is set to (3 ) Characteristic C: for protection of electric circuits with equipment that causes current surges (light bulb groups, motors etc.); the short-circuit release is set to ( 9) Characteristic D: for protection of electric circuits with equipment that causes high current surges (transformers, 2-pole motors etc.); the short-circuit release is set to (2 20 0 0 000 000.3 In.4 In 30 min. 0 000 00 2 00 0 0 t [s] v At ambient temperature +30 C 0. 0. B C D 0.0 0.00 0.002 0.00 2 3 4 8 0 20 30 40 0 80 B C D x Tripping characteristics miniature circuit breakers according to EN 0 898 Thermal release Tripping characteristic type Tripping characteristic type Electromagnetic release B, C, D B C D Conventional non-tripping current t for t h (for 3 A) Current I t =.3 I 4 for 0. s < t < 4 s (for 32 A) n Int for t 2 h (for > 3 A) 0. s < t < 90 s (for > 32 A) I 4 = 3 Conventional tripping current I t for t < h (for 3 A) 0. s < t < s (for I I t =.4 32 A) n It for t < 2 h (for > 3 A) 0. s < t < 30 s (for > 32 A) I 4 = Current I 3 for s < t < 0 s (for 32 A) 0. s < t < 4 s (for I I 3 = 2. 32 A) s < t < 20 s (for n In > 32 A) 0. s < t < 8 s (for > 32 A) I 4 = 0 t - break time of the circuit breaker Current I for t < 0.s I = I = 0 I = 20 for 0 A, it is permissible that t < 8 s t - break time of the circuit breake

AUXILIARY AND RELATIVE SWITCHES Auxiliary switches S-LSN, S-LSN2 Accessories to: LSN, LSE, LST, ASN, AST The auxiliary switches are designed for signalling the position of the main contacts of miniature circuit breakers and tumbler power switches in tripping by releases or manually i.e. in tripping by overload, short-circuit, shunt trip, overvoltage release or control lever At correct connection of S-LSN or S-LSN2 with a miniature circuit breaker or tumbler power switch electric isolation is provided like between the input and output circuits of a protective transformer The auxiliary switch function can be tested by the test push-button on the front panel of the device Auxiliary and relative switch S-LSN200 Accessories to: LSN, LSE, ASN The auxiliary and relative switch is designed for signalling the position of the main contacts of miniature circuit breakers and tumbler power switches in tripping: by releases or manually i.e. in tripping by overload, short-circuit, shunt trip, overvoltage release or control lever. This is signalled by auxiliary switches terminals 33-34, 23-24 only by releases i.e. only in tripping by overload, short-circuit, shunt trip or overvoltage release. This is signalled by so called relative switch terminals 9-9 The auxiliary switch function can be tested by the test push-button on the front panel of the device Auxiliary and relative switches Contact Type Product sequence code Weight [kg] S-LSN 094 0.0 2 S-LSN2 09 0.0 200 S-LSN200 098 0.0 Each digit indicates successively the number of make, break, break-make and relative contacts Packing [pcs] Specification Type S-LSN, S-LSN2 S-LSN200 Standards EN 0 947-- EN 0 947-- Approval marks Contact sequence 2), 2 200 Rated operating voltage / current AC- U e /I e 230 V/ A 230 V/ A AC- U e /I e 230 V/4 A or 400 V/2 A - DC- U e /I e - 220 V/ A DC-3 U e /I e 220 V/ A - Rated impulse withstand voltage U imp 4 kv 2. kv Endurance 0 000 operating cycles 0 000 operating cycles Degree of protection IP20 IP20 Mounting on right side on right side Connection - conductor rigid 0.7 4 mm 2 0.7 4 mm 2 flexible 0.7 2. mm 2 0.7 2. mm 2 Seismic immunity (8 0 Hz) 3 g 3 g Each digit indicates successively the number of make, break, break-make and relative contacts 2) Another possibility to achieve a higher number or a different sequence of contacts: install V0-LSN shunt trip on the left side of the device and use only the auxiliary switch function Dimensions S-LSN 0 33 23 (9) 93 90 4 2(9) 24 34 8.7. 44 70 9

AUXILIARY AND RELATIVE SWITCHES Diagram S-LSN S-LSN2 S-LSN200 33 33 23 33 23 9 TEST TEST TEST 34 2 34 24 2 34 24 9 Assembly and installation of auxiliary switches Assembly or LST AST LSN LSE ASN S-LSN... Installation of an auxiliary switch on a miniature circuit breaker or tumbler power switch (hereinafter only the device):. Switch on both the auxiliary switch and the device. 2. Insert one shaft into the control lever of the device and the second shaft (for LST, AST the shaft is plastic) into the hole in the switching system of the device. 3. Slide the auxiliary switch from the right onto the device in such a way that one shaft interconnects control levers and the other interconnects the switching systems. 4. Press the auxiliary switch to the device and click the side fixing latches of the auxiliary switch into the device recess.. Check correct function by switching. metallic shaft - LSN, LSE, ASN, LST, AST metallic shaft - LSN, LSE, ASN plastic shaft - LST, AST LSN, LSE, ASN LST, AST S-LSN... 20

SHUNT TRIPS Miniature circuit breakers Accessories to: LSN, LST, LSE, ASN, AST For tripping the miniature circuit breakers or tumbler power switch by applied voltage between 70 % and 0 % U e For signalling the position of the main contacts of the miniature circuit breaker or tumbler power switch by make or break-make contact The shunt trip coil is connected to terminals A and A2 to ensure its disconnection from the control voltage in the device trip. So the coil is powered for a required time. The disconnection is provided by the contact in the circuit between the terminals A and A2. Shunt trips V0-LSN contains additionally an auxiliary switch with break-make contact Shunt trips U n Contact sequence - 0 Contact sequence - 0 Weight Packing AC/DC [V] Type Product code Type Product code [kg] [pcs] 24 / 24 V0-LSN-X024 08487 V0-LSN-X024 08497 0.2 48 / 48 V0-LSN-X048 08488 V0-LSN-X048 087 0.2 0 / 0 V0-LSN-X0 08489 V0-LSN-X0 0892 0.2 230 / 220 V0-LSN-X230 08490 V0-LSN-X230 08498 0.2 400 / 440 V0-LSN-X400 0849 V0-LSN-X400 08499 0.2 Each digit indicates successively the number of make, break and break-make contacts Specification Type V -LSN Standards EN 0 947- Coil Rated operating voltage U e 24, 48, 0, 230, 400 V a.c. 24, 48, 0, 220, 440 V d.c. Rated frequency f n 40 0 Hz Max. starting input power 90 VA Break time 0 ms Contact Sequence 0, 0 Rated operating voltage / current AC- U e /I e 230 V / 4 A or 400 V / 2 A DC- U e /I e 220 V / 0. A AC- U e /I e 230 V / 2 A Endurance 0 000 operating cycles Other data Mounting on the left side Connection - conductor rigid and flexible 0.7 2. mm 2 Degree of protection IP20 Seismic immunity (8 0 Hz). g Each digit indicates successively the number of make, break and break-make contacts Dimensions V...-LSN 2. 7. 90 4 A2 A 24 22 2 7.. 44 0 70 2

SHUNT TRIPS Diagram V0-LSN A A2 V0-LSN A A2 22 24 2 Assembly and installation of shunt trips Assembly or V...-LSN LSN LSE ASN LST AST Installation of a shunt trip on a miniature circuit breaker or tumbler power switch (hereinafter only the device):. Switch off both the shunt trip and the device. 2. Insert one shaft into the control lever of the shunt trip and the second shaft (for LST, AST the shaft is plastic) into the hole in the switching system of the shunt trip. 3. Slide the device from the right onto the shunt trip in such a way that one shaft interconnects control levers and the other interconnects the switching systems. 4. Press the device to the shunt trip and click the side fixing latches of the shunt trip into the device recess.. Check correct function by switching metallic shaft - LSN, LSE, ASN, LST, AST metallic shaft - LSN, LSE, ASN plastic shaft - LST, AST V...-LSN LSN, LSE, ASN LST, AST 22

UNDERVOLTAGE RELEASES Accessories to: LSN, LST, LSE, ASN, AST For tripping the miniature circuit breaker or tumbler power switch at voltage drop between 70 % and 3 % U e For tripping the miniature circuit breaker or tumbler power switch on pressing the switch-off push-button For elimination of miniature circuit breakers or tumbler power switch closing at voltage lower than 3 % on the undervoltage release (the closing is possible at U 8 % U e ) It is frequently used for protection against motor restart after the mains failure Undervoltage releases N0-LSN contain in addition an auxiliary switch with make and break-make contact for signalling the position of main contacts of the miniature circuit breaker or tumbler power switch Undervoltage releases U n Without contacts Contact sequence - 0 Weight Packing AC [V] Type Product code Type Product code [kg] [pcs] 24 N-LSN-A024 0847 N0-LSN-A024 0848 0.2 48 N-LSN-A048 0847 N0-LSN-A048 0903 0.2 0 N-LSN-A0 08477 N0-LSN-A0 090 0.2 230 N-LSN-A230 08478 N0-LSN-A230 0848 0.2 400 N-LSN-A400 08479 N0-LSN-A400 08927 0.2 Specification Type N -LSN Standards EN 0 947- Coil Rated operating voltage U e 24, 48, 0, 230, 400 V a.c. Rated frequency f n 40 0 Hz Consumption 2. W Max. starting input power 90 VA Break time 2 ms Contact Sequence 0, 0 Rated operating voltage/current AC- U e /I e 230 V / 4 A or 400 V / 2 A DC- U e /I e 220 V / 0. A AC- U e /I e 230 V / 2 A Endurance 0 000 operating cycles Other data Mounting on the left side Connection 0.7 2. mm 2 Degree of protection IP20 Operating position vertical Seismic immunity (8 0 Hz) 3 g Each digit indicates successively the number of make, break and break-make contacts Dimensions 23

UNDERVOLTAGE RELEASES Diagram N-LSN N0-LSN A A 3 22 24 U< U< A2 A2 2 Assembly and installation of undervoltage releases Assembly or N...-LSN LSN LSE ASN LST AST Installation of an undervoltage release on a miniature circuit breaker or tumbler power switch (hereinafter only the device):. Switch off both the undervoltage release and the device. 2. Insert one shaft into the control lever of the undervoltage release and the second shaft (for LST, AST the shaft is plastic) into the hole in the switching system of the undervoltage release. 3. Slide the device from the right onto the undervoltage release in such a way that one shaft interconnects control levers and the other interconnects the switching systems. 4. Press the device to the undervoltage release and click the side fixing latches of the undervoltage release into the device recess.. Check correct function by switching metallic shaft - LSN, LSE, ASN, LST, AST metallic shaft - LSN, LSE, ASN plastic shaft - LST, AST N...-LSN LSN, LSE, ASN LST, AST 24

Interconnecting systems INTERCONNECTING BUSBARS AND END CAPS Interconnecting busbars For interconnection of to 4-pole circuit breakers, tumbler power switches, residual current circuit breakers, lightning current arresters and surge voltage arresters For interconnection of a series of single-phase or three-phase circuit breakers and tumbler power switches, on which an auxiliary switch is mounted Busbars G- with forks into the head part of the device Busbars S- with pins into the clip part of the device End cap EK-C-3: To cover end of busbar G-3L-000/0C End cap EK-C-2+3: To cover end of busbar G-2L-000/, G-3L-000/C, S-3L-27-000/ End cap EK-C-3/3: To cover end of busbar S-3L-27-000/2 End cap EK-C-4/: To cover end of busbar G-4L-000/ Interconnecting busbars Phase Cross - Max. current at power Length Type Product Accessories to Weight Packing section supply of [A/phase] [mm] code [kg] [pcs] [mm 2 ] end middle 2 0 000 G-L-000/2 007 LSN, LSE, ASN 0. 22 0 G-L-000/2g 0070 LSN, LSE, ASN 0. 0 80 30 20 S-L-20/iso 302 LSN, LSE, SVL, SJL, ASN 0.04 0 20 90 0 000 G-L-000/20 0072 LSN, LSE, SJB, SVM, ASN 0.3 0 24 00 80 000 G-L-27-000/24 2) 00 LSN, LSE, ASN 0.3 0 2 80 30 000 G-2L-000/ 79 LSN, LSE, LFI, LFE, OFI, OFE, ASN 0.4 20 3 0 3 00 000 G-3L-000/0C 0073 LSN, LSE, ASN 0.44 20 80 30 000 G-3L-000/C 0074 LSN, LSE, OFI, OFE, SJB, SVM, ASN 0.72 20 G-3L+9-000/ 2) 002 LSN, LSE, ASN 0. 0 S-3L-27-000/ 3) 84 LSN, LST, LSE, ASN, AST 0.2 20 2 00 80 000 S-3L-27-000/2 3) 8 LSN, LST, LSE, ASN, AST 0.9 0 4 80 30 000 G-4L-000/ 80 LSN, LSE, OFI, OFE, ASN 0.9 The busbar is uninsulated 2) For -pole or 3-pole devices with an auxiliary switch 3) For 3-pole LST; for -pole LSN, LSE, ASN with an auxiliary switch End caps Type Product Accessories to Weight Packing code [kg] [pcs] EK-C-3 0078 G-3L-00/0C 0.00 0 EK-C-2+3 008 G-2L-000/, G-3L-000/C, S-3L-27-000/ 0.00 0 EK-C-3/3 7 S-3L-000/2 0.002 0 EK-C-4/ 8 G-4L-000/ 0.002 0 Specification Type G-L, G-2L, G-3L, G-4L, S-L, S-3L Rated operating voltage U e 230/400 V a.c., 220/440 V d.c. Load current 3 80 A Length 20, 000 mm Cross-section 0 2 mm 2 Diagram G-L, S-L G-2L G-3L, S-3L G-4L L L L2 L L2 L3 L L2 L3 N (N) 93

Interconnecting systems INTERCONNECTING BUSBARS AND END CAPS Dimensions G-L-000/2 G-L-000/2g 7x 7.8 99.8 (x7.8) 2. 7x 7.8 99.8 (x7.8) 3 2 S-L-20/iso 2x 7.8 4 9.8 (x7.8). 7x 7.8 2 99.8 (x7.8) 2 G-L-000/20 G-L-27-000/24 37x 972 (3x27) 27 2 2 G-2L-000/ 28x2 7.8 979 (x7.8). 29 7 G-3L-000/0C G-3L-000/C 9x3 7.8 99.8 (x7.8) 9x3 7.8 99.8 (x7.8). 2 30 3. 7 G-3L+9-000/C S-3L-27-000/ x3 97. (47x7.8+x9) 7.8 2.8 (+9) 2. x3 2.8 938 (3x2.8) 4. 29 29 24. 7 S-3L-27-000/2 G-4L-000/ x3 27 94 (3x27). 2 x4 979 (x7.) 7.8. 7 30 43 27 20. 8.3 94

-2-2 Interconnecting systems CONNECTING ADAPTERS AND BLOCKS Connecting adapter AS/2-GN Accessories to: LSN, LSE, LFI, LFE, OFI, OFE, SJB, SVM, ASN For connection of another conductor to the head part of the terminal of a circuit breaker or tumbler power switch For example, it the best solution is to connect a conductor for power supply of an electric meter in the clip part of the circuit breaker terminal, and another conductor through the connecting adapter AS/2-GN in the head part of the circuit breaker terminal Conductor cross-section: 2 mm 2 Connecting adapter AS/2-SN Accessories to: OFI20, OFE20, SVL, SJL, RP For connection of conductor to the clip part of the terminal of a circuit breaker or tumbler power switch Conductor cross-section: 2 mm 2 Connecting adapter AS-AL/Cu--0 Accessories to: LSN, LST, LSE, LFI, LFE, SJBplus, ASN, AST For connection of Al or Cu conductors Cross-section of Cu conductors: 2. 0 mm 2 Cross-section of Al conductors: 0 mm 2 Connecting adapter CS-FH000-...NP9 Accessories to: LST, SJBplus, SJB00/NPE/,, AST For connection of Cu/Al conductors of cross-section 3 9 mm 2 Connecting adapter with straight terminal Connecting adapter CS-FH000-3NV9 Accessories to: LST, SJBplus, SJB00/NPE/,, AST For connection of Cu/Al conductors of cross-section 3 9 mm 2 Connecting adapter with outbowed terminal Connecting adapter N3x0-FH000 Accessories to: LST, SJB, SVM, AST For connection of 3 conductors/pole of the device of cross-section 0 mm 2 Connection block ES/3S/G Accessories to: G-L, G-2L, G-3L, G4-L, S-L, S-3L It enables power supply of interconnecting busbars of conductors of section up to 3 mm 2 The blocks can be installed in series to create a multiplepole connection block Degree of protection IP20 Connecting adapters Type Product Weight Accessories Set Packing code [kg] to [pcs] [pcs] AS/2-GN 0077 0.02 LSN, LSE, LFI, LFE, OFI, OFE, SJB, SVM, ASN 0 AS/2-SN 007 0.03 OFI20, OFE20, SVL, SJL, RP 0 AS-AL/Cu--0 83 0.0 LSN, LST, LSE, LFI, LFE, SJBplus, ASN, AST CS-FH000-3NP9 3740 0. LST, SJBplus, SJB00/NPE/,, AST 3 CS-FH000-NP9 378 0. LST, SJBplus, SJB00/NPE/,, AST CS-FH000-3NV9 3742 0. LST, SJBplus, SJB00/NPE/,, AST 3 N3x0-FH000 27 0.02 LST, SJB, SVM, AST 3 Connection block Type Product Weight Packing code [kg] [pcs] ES/3 S/G 007 0.03 0 Dimensions AS/2-GN 7 AS/2-SN AS-Al/Cu--0 N3x0-FH000 7. 22 24. 7. 20. -2-2 20. 2. 27 CS-FH000-...NP9 CS-FH000-3NV9 ES/3 S/G 24 32. 24 32. 7. 2. 38 38 32 9