2-port and 3-port terminal unit valves PN16

Similar documents
Butterfly Valves PN 6/10/16 for flanged connection

2- and 3-port valves with flanged connections, PN 10

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Type overview. Technical data

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Overview of types. Technical data

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

HERZ-Thermal Actuators

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Type 3353 Angle Seat Valve

Pressure Independent Control Valves. The Future of Energy Saving

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Digital inductive conductivity transmitter

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

VAD Variable Area Desuperheaters

VAD. Variable Area Desuperheaters

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Data sheet ECC 12 and 22

Assisted lift operated 2/2-way solenoid valves Type EV250B

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic Actuators

Automatic control equipment for HVAC systems

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

V5001S. Kombi-S Shutoff Valve. Product specification sheet

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Self-operated Temperature Regulators Temperature Regulator Type 1u

Stainless Steel Single and Dual Circulation Kits

kymanual or Automatic - it s your Choice

QLM and QLD Series Three-port Control Valves

Automatic Bypass Control AVDO

RRV934. Multi-controller. Synco living

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

How To Use A Flowmeter

Thermostatic element RAVV for 2-way valves

SISTO-16TWA/HWA/DLU. Type Series Booklet

How To Use A Corona Mdi 110

4/2-Way Pneumatic Solenoid Valve

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Actuator for modulating control AME 435

MFP14, MFP14S and MFP14SS Automatic Pumps

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

3/2-way Solenoid Valve, direct-acting, NC or NO

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

REGULATORS 175/153 Series

Technical data. Danfoss DHP-A

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Cable Plug acc. to DIN EN , Form A

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Products no longer available

3/2-way pneumatic cartridge solenoid valve

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

PRESSURE REDUCING CONTROL VALVE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Series description: Wilo-Star-Z

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

3/2- and 2/2-way cartridge valve type BVE

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Why and How we Use Capacity Control

3/2-way Mini Solenoid Valve

VG2000 Series Cast Iron Flanged Globe Valves

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

ECOCIAT. Domestic hot water heat recovery unit

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Under sill units. Type FSL-B-ZAS

Solenoid valves 2/2-way direct-operated Type EV210A

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Stainless steel process fittings

Thermostatic valve Type AVTA

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Fluxi 2000/TZ Turbine Gas Meter

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

SITRANS F flowmeters SITRANS F M

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Automatic balancing valves ASV

Technical Specification. Generating Set with Waukesha engine burning natural gas

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

V47 Series Temperature Actuated Modulating Water Valves

Baumann Little Scotty Bronze Control Valve

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

4 847 2-port valves VVP47..(S) 3-port valves VXP47.. cvatix 2-port and 3-port terminal unit valves PN16 3-port valves with bypass VMP47..(S) VVP47..(S) VXP47.. VMP47..(S) ronze valve body CC491K (Rg5) max. 4% Pb DN 10, DN 15 and DN 20 k vs 0.25 to 4 m 3 /h Linear characteristic Flat seal male threaded connections.. to ISO 228-1 V..P47..S valves: Male threaded connections for use with Conex compression fittings for copper pipes Manual adjuster Can be combined with SSP.., SFP.. electromotoric actuators or STP..3.. electrothermal actuators Use For use in ventilation and air conditioning systems for water-side terminal unit control in closed circuits, e.g. for induction units, fan coil units, small re-heaters and small recoolers. - 2-pipe systems with 1 heat exchanger for heating and cooling - 4-pipe systems with 2 separate heat exchangers for heating and cooling In closed-circuit zone heating systems, e.g. for: - Separate floors in a building - partments and individual rooms The VXP47..S 3-port valves together with SFP.. actuators are specially suited for changeover applications where small leakage rates are required. C1N4847en 2014-03-10 uilding Technologies HVC Products

Type summary VVP47.. 1) VVP47..S 2) VXP47.. 1) VMP47.. 1) VMP47..S 2) DN k vs 3) k vs 2-port 2-port 3-port 3-port 3-port with bypass with T-bypass [m 3 /h] [m 3 /h] VVP47.10-0.25 VXP47.10-0.25 VMP47.10-0.25 0,25 0,18 VVP47.10-0.4 VXP47.10-0.4 VMP47.10-0.4 0,40 0,28 VVP47.10-0.63 VVP47.10-0.63S VXP47.10-0.63 VMP47.10-0.63 VMP47.10-0.63S 10 0,63 0,44 VVP47.10-1 VVP47.10-1S VXP47.10-1 VMP47.10-1 VMP47.10-1S 1,00 0,70 VVP47.10-1.6 VVP47.10-1.6S VXP47.10-1.6 VMP47.10-1.6 VMP47.10-1.6S 1,60 1,12 VVP47.15-2.5 VVP47.15-2.5S VXP47.15-2.5 VMP47.15-2.5 VMP47.15-2.5S 15 2,50 1,75 VVP47.20-4 VXP47.20-4 20 4,00 2,80 1) 2) 3) k vs Flat seal male threaded connections Male threaded connections for use with Conex compression fittings pplies only to 3-port version = nominal flow rate of cold water (5 30 C) through the fully opened valve (H 100) at a differential pressure of 100 kpa (1 bar) ccessories Prod. No. Stock no. Description L..2 L..2 Set of 2 fittings with threaded connections for 2-port valves or 3-port valves with bypass, consisting of: 2 union nuts, 2 discs and 2 flat seals L..2 S55846-Z1.. L..3 are brass fittings, for media temperatures up to 100 C. L..3 L..3 Set of 3 fittings with threaded connections for 3-port valves, consisting of: 3 union nuts, 3 discs and 3 flat seals L..3 S55846-Z1.. L..3 are brass fittings, for media temperatures up to 100 C. Ordering Please give valve and the required L.. threaded fittings. The L.. threaded fittings and the SSP.., SFP.. and STP..3.. actuators must be ordered as separate items. Example: Product number Stock number Description Quantity VXP47.10.1 VXP47.10.1 3-port Terminal Unit Valve PN16 4 L133 L133 Threaded Fittings 4 Delivery For 3-port valves with bypass VMP47.. order two sets of L..2 or L..2 threaded fittings. Valves, actuators and fittings are packed and supplied separately. Equipment combinations Valves Electromotoric actuators Electrothermal actuators SSP.. SFP.. STP..3.. Dp max Dp s Dp max Dp s Dp max Dp s [kpa] [kpa] [kpa] [kpa] [kpa] [kpa] VVP47.10-0.25 0.4 1000 1000 400 700 400 400 VVP47.10-0.63 1(S) 500 500 250 250 VVP47.10-1.6(S) 300 300 300 300 150 150 VVP47.15-2.5(S) VVP47.20-4 175 175 175 175 100 100 VXP47.10-0.25 0.4 400 400 400 VXP47.10-0.63 1 250 VXP47.10-1.6 VXP47.15-2.5 300 300 150 VXP47.20-4 175 175 100 VMP47.10-0.25 0.4 400 400 400 VMP47.10-0.63 1(S) 250 VMP47.10-1.6(S) VMP47.15-2.5(S) 300 300 150 Data sheet N4864 N4865 N4884 1) fter a power failure or switching off the operating voltage the control path of the valve opens. Dp max = maximum permissible differential pressure across the control path of the valve valid for the entire actuating range of the motorized valve 2/10 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

Overview of actuators Dp s ctuator = maximum permissible differential pressure (close of pressure) at which the motorized valve will close securely against the pressure Type of actuator Operating voltage Positioning signal Positioning time SSP31 C 230 V 150 s SSP81 3-position C 24 V SSP81.04 43 s Electromotoric SSP61 C / DC 24 V DC 0...10 V 34 s SFP21/18 SFP71/18 C 230 V C 24 V Positioning force 160 N 2-position 10 s 135 N STP23 C 230 V 2-position 210 s STP73 2-position Electrothermal C / DC 24 V 270 s STP73PR/00 3) 2-position / PDM 1) STS63 C 24 V DC 0 10 V 270 s 2) 100 N 1) 2) 3) PDM = Pulse-Duration-Modulation refer to data sheet N4880 for details Variant for PDM and parallel flow Sizing k vs ( ) 2.5 4.0 1.6 1.0 0.63 3 1 0.4 0.25 Example: 2 1 V & 100 = 0.083 l/s 2 Dp v100 = 9 kpa 3 Required k vs-value = 1.0 m 3 /h Dp v100 = differential pressure across the fully open valve and control path by a volume flow &V 100 &V 100 = volume flow through the fully open valve (H 100) Dp max = maximum permissible differential pressure across the valve s control path, valid for the entire actuating range of the motorized valve 100 kpa = 1 bar» 10 mwc 1 m 3 /h = 0.278 l/s water at 20 C Valve characteristics Flow k v /k vs 1 0,8 0,6 0,4 0,2 0 0 0,2 0,4 0,6 0,8 1 4847D02en With valve types VXP47../VMP47..(S), the k vs values in bypass represent only 70 % of the k vs value in the straight-through control path,. This compensates for the flow resistance of the heat exchanger or radiator, so keeping the overall flow rate, &V 100 as constant as possible. Stroke H/H 100 3/10 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

Mechanical design Combined disc / plug flow restrictor Seat ring embedded in through-port à Seat machined into bypass à. Continuously lubricated sealing rings Conical return springs, for more compact valve construction Engineering notes lso refer to "Mounting notes" and "Commissioning", page 5. The 2-port valves should preferably be installed in the return, where the stem seal will be exposed to lower temperatures. Recommendation: strainer should be fitted upstream of the valve. This increases reliability. Valve construction Valve series Valve flow in control mode Valve stem Inlet Inlet Outlet Retracted Extended 2-port valves VVP47..(S) 4847Z01 variable variable opens closes 3-port valves VXP47.. 4847Z02 variable variable constant opens closes closes opens 3-port valves with bypass VMP47.. (S) 4847Z03 variable variable constant opens closes closes opens Warning The direction of flow MUST be as indicated by the arrow, i.e. only from and. The 3-port valve types VXP47.. and VMP47..(S) may only be used in mixing applications. Mounting notes Orientation 90 SSP.., SFP.. 90 STP..3.. 90 90 4/10 4362Z01 90 90 2185Z12 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

The specified direction of flow must be observed in all cases, also refer to "Engineering notes", page 4. The valves are delivered in single packs; Mounting Instructions 74 319 0301 0 are enclosed with the packaging. The valve and actuator can be easily assembled on site. There is no need for special tools or calibration. L50 supporting ring The L50 supporting ring 1) must be put into position before mounting the actuator SFP.. onto the valve. Only the equipment combination V..P47.. and SFP.. requires supporting ring L50. 1) Included in delivery of the SFP.. actuator 3 k VS = 1.6m /h L50 4847Z05 Datum/Date JJMM/YYMM Commissioning Commission the valve only if the manual knob or actuator have been mounted correctly. Manual adjustment The straight-through control path can be opened either electrically via the actuator, or by adjustment with the manual button. In the case of 3-port valves, this throttles or closes bypass. Maintenance V..P47..(S) valves require no maintenance. Warning When doing service work on the valve / actuator: Deactivate the pump and turn off the power supply Close the shutoff valves Fully reduce the pressure in the piping system and allow pipes to completely cool down If necessary, disconnect the electrical wires. efore putting the valve into operation again, make certain the manual knob or the actuator is correctly fitted. Stem sealing gland Disposal The stem sealing gland cannot be exchanged. In the case of leakage, the entire valve must be replaced. Contact your local office or branch. The valve must be dismantled and separated into its various constituent materials before disposal. Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view. Current local legislation must be observed. Warranty The technical data supplied for these valves is valid only for valves used in conjunction with the actuators listed under "Equipment combinations", page 2. Use with third-party actuators invalidates any warranty offered by Siemens Switzerland Ltd / HVC Products. uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10 5/10

Technical data Operating data PN class PN 16 to EN 1333 Permissible operating pressure Valve characteristic Path ypass Leakage rate Path ypass Permissible media 1600 kpa (16 bar) linear linear to DIN EN 1349 0 0.05 % of k vs value 0 0.05 % of k vs value chilled water, low-temperature hot water and water with frost protection additives recommendation: water should be treated as specified in VDI 2035 Temperature of medium 1...110 C, or max. 120 C for short periods 1) Rangeability S v > 50 as in VDI 2173 Nominal stroke 2.5 mm Norms and standards Pressure Equipment Directive PED 97/23/EC Pressure ccessories as per article 1, section 2.1.4 Fluid group 2 Environmental compatibility without CE-marking as per article 3, section 3 (sound engineering practice) ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) RL 2002/95/E (RoHS) Materials Valve body bronze CC491K (Rg5) max. 4% Pb Stem Plug, seat ring, gland Stem seal stainless steel brass EPDM O-rings Dimensions / weight Dimensions refer to "Dimensions", page 7 ccessories Threaded connections (V..P47..) Valve Threaded fittings Threaded connections (V..P47..S) Valve DN 10 Valve DN 15.. to ISO 228-1 R/Rp.. to ISO 7-1,.. to ISO 228-1.. to ISO 228-1 W1⅛-14 to S84 ctuator connection M30 x 1.5 Weight refer to "Dimensions", page 7 L..2, L..3 threaded fittings (supplier: Siemens) nut, nipple and flat seal for steel pipes with gas-pipe threads SERTO SO 00021.. threaded fittings (available from suppliers to the trade) Welded fittings (available from suppliers to the trade) nut and compression fitting for seamless copper and mild-steel piping for copper and steel piping 1) L.. fittings for media temperatures up to 100 C S v k vs = rangeability k vs / k vr = nominal flow rate of chilled water (5 30 C) through the fully opened valve (H 100) at a differential pressure of 100kPa (1bar). k vr = the lowest value for k v at which the flow characteristic tolerance is still maintained, at a differential pressure of 100kPa (1 bar) 6/10 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

Dimensions 2-port valves VVP47.. 3-port valves VXP47.. 3-port valves with bypass VMP47.. L3 K L3 d d d H1 H2 H1 H2 H1 H2 4847Z06 4847Z07 4847Z08 L2 L1 L2 L1 L2 L1 2-port valves VVP47..(S) 4850Z01 3-port valves with T-bypass VMP47..(S) 4850Z03 K L3 d d H1 H2 H1 H2 L2 L1 L2 L1 Product number DN d H1 H2 L1 L2 L3 Weight [Inch] [mm] [mm] [mm] [mm] [mm] [mm] [kg] VVP47.10-0.25 1.6 10 ½ 10.5 46» 49 60 30 19 0.32 VVP47.10-0.63S... 1.6S 10 ½ 15,2 46» 49 60 30 19 0,32 VVP47.15-2.5 15 ¾ 14 46» 49 65 32.5 19 0.34 VVP47.15-2.5S 15 W1⅛-14 22,2 46» 49 65 32,5 19 0,34 VVP47.20-4 20 1 20 49» 52 80 40 23 0.44 Product number DN d H1 H2 L1 L2 L3 Weight [Inch] [mm] [mm] [mm] [mm] [mm] [mm] [kg] VXP47.10-0.25 1.6 10 ½ 10.5 46» 49 60 30 30 0.32 VXP47.15-2.5 15 ¾ 14 46» 49 65 32.5 32.5 0.37 VXP47.20-4 20 1 20 49» 52 80 40 40 0.5 Product number DN d H1 H2 K L1 L2 Weight [Inch] [mm] [mm] [mm] [mm] [mm] [mm] [kg] VMP47.10-0.25 1.6 10 ½ 10.5 46» 49 40 60 30 0.4 VMP47.10-0.63S... 1.6S 10 ½ 15,2 46» 49 40 60 30 0,4 VMP47.15-2.5 15 ¾ 14 46» 49 40 65 32.5 0.48 VMP47.15-2.5S 15 W1⅛-14 22,2 46» 49 40 65 32,5 0,48 7/10 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

Sets of threaded fittings with flat seal: Set of 2 (for V..P47..) R T L 4847Z09 Prod. no. /stock no. Prod. No. Stock no. Connection Rp pipe side [Inch] [Inch] L132 External thread ½ R ⅜ L142 External thread ¾ R ½ Rp 4363M02 L122 Internal thread ¾ Rp ⅜ L152 L152 S55846-Z100 Internal thread 1 Rp ½ Set of 3 (for V..P47..) 4847Z09 Prod. no. /stock no. Prod. No. Stock no. Connection pipe side [Inch] Rp [Inch] R L133 External thread ½ R ⅜ T L143 External thread ¾ R ½ L 4363M02 L123 Internal thread ¾ Rp ⅜ L153 L153 S55846-Z101 Internal thread 1 Rp ½ Rp Overview fitting combinations (with V..P47..) L... type for valve type DN R Rp L T [inch] [inch] [inch] [mm] [mm] L132 VVP47.10-0.25...1.6 L133 VXP47.10-0.25...1.6 10 ½ R ⅜» 24» 9 2 x L132 VMP47.10-0.25...1.6 L142 L143 VVP47.15-2.5 VXP47.15-2.5 15 ¾ R ½» 29.5» 12 2 x L142 VMP47.15-2.5 L152 L152 L153 L153 VVP47.20-4 VXP47.20-4 20 1 Rp ½» 23» 13 DN = Nominal size = Valve thread (internal cylindrical) 8/10 uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10

Conex compression fittings (for V..P47..S) Union nut Compression fitting Conex 63 Conex 65 D 4850Z07 For valve type DN Type Conex D k vs- value [inch] (from specialist supplier) Product-Nr. [mm] VVP47.10-..S VMP47.10-..S VVP47.15-2.5S VMP47.15-2.5S Conex 63 E--10CO063-- 0,63 1,6 10 ½ + + 15 Conex 65 Conex 63 E--10CO065-- --10CO063-- 2,5 15 W1⅛-14 + + 22 Conex 65 --10CO065-- DN = nominal size = valve thread (internal, cylindrical) D = external diameter for seamless copper and mild-steel piping Spare parts Type Stock No. Description Number 74 676 0295 0 74 676 0295 0 Manual knob for small valves 2.5 mm 10 Revision numbers Product number Valid from manufacturing date Product number Valid from manufacturing date Product number Valid from manufacturing date VVP47.. 0809 1) VXP47.. 0809 1) VMP47.. 0809 1) 1) MMYY = Month, Year of manufacturing uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10 9/10

10/10 ã 2009 2014 Siemens Switzerland Ltd Subject to alteration uilding Technologies 2-port and 3-port Terminal Unit Valves PN16 C1N4847en HVC Products 2014-03-10