Measured value modules for DC ma and DC ma measuring ranges

Similar documents
Digital input modules

Impulse contacts are not suitable for use as status contacts.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Duct Humidity Transmitter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

TX OPEN RS232/485 module

Electronic Control Devices The European Product Catalogue 2007

PCS0100en Persy Control Services B.V. Netherlands

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

OZW30. Central Unit SYNERGYR

Modular I/O System Analog and Digital Interface Modules

Contents. Document information

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Air damper actuators

Heating Controller. Building Technologies HVAC Products

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Vario-Series Accessories

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

3DLevelScanner II TECHNICAL DATA SHEET

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Current Loop Application Note 1495

RRV934. Multi-controller. Synco living

Current and voltage measuring relays

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Electric Rotary Actuator - On/Off or programmable control actuator

PART 1 - INTRODUCTION...

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MINI MCR-SL-R-UI(-SP)

Waveguide Access Point WGA631. Product Guide

Rosemount 333 HART Tri-Loop

Electronic Control Devices The European Product Catalogue 2007

T Substation Maintenance and Commissioning Test Equipment

ABB Drives. User s Manual HTL Encoder Interface FEN-31

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Technical Data Sheet. 3DLevelScanner

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

How To Use A Flowmeter

J TB/TW Temperature limiter, temperature monitor

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

DC Electronic Loads 8500 series

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Features, Benefits, and Operation

T0118 T2118 T3118. Instruction Manual

Disturbance Recoder SPCR 8C27. Product Guide

Rosemount 333 HART Tri-Loop

Application/Connection Examples

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

HMI display Installation Guide

Quick Connect. quick - simple - efficient.

Product and functional description

IO-RM3 3-Stage Relay Module

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SMART SENSOR COLLECTION

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Technical Data. Dimensions

PXM20-E. Operator unit DESIGO PX

EBS852 (Contrac) Power Electronic Unit

Video Splitter VS-104 / VS-108 User's Manual

R.C.C.B. s two-pole LEXIC

USB-AD16f Data acquisition system (USB)

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

USB-AD14f Data Acquisition System (USB)

Room Temperature Sensors

Measuring Temperature withthermistors a Tutorial David Potter

T7560A,B,C Digital Wall Module

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Model: DC-A2IO Advanced HVAC Controller

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Digital inductive conductivity transmitter

How To Use A Power Supply On A Powerline 2.2 (Ai)

Energy Management Energy Meter Type EM23 DIN

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

HDMI INTO VGA/Audio MULTIMEDIA CONVERTER USER MANUAL (DS-40310)

Drayton Digistat +2RF/+3RF

15 Series - Electronic step relay and dimmer. Features SERIE

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

aseries A13B Mini Bullet Camera User Manual

HERZ-Thermal Actuators

VAV compact controller KNX / PL-Link

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Power Meter Series 700

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Transcription:

129 PT1.225/020 PT1.2420 DESO /O modules easured value modules for DC 0...25 ma and DC 4...20 ma measuring ranges PT1.225/020 PT1.2420 easured value converters for connection to P-bus, with two separate inputs (double modules). Two versions: measuring range DC 0...25 ma measuring range DC 4...20 ma se The measured value modules are used to acquire measured values in the form of currents. nits that deliver such measured values are, for example: measuring converters measuring current sources units and systems with current outputs, made by other manufacturers sing plug-in shunts with module type PT1.225/020, the following measuring ranges can be selected: 1...5 ma 0...10 ma 0(4)...20 ma 0...25 ma Without a shunt, there is a voltage measuring range of DC 0...1 V available. odule type PT1.2420 has a fixed current range of 4...20 ma. C2N129en 20.11.2001 Siemens Building Technologies Building Automation

Functions easured value conversion of analog current signals from the plant to digital P-bus signals for handling by the automation station. odule type PT1.225/020 offering selectable measuring ranges. Power supply facility for connected measured value sources in the range at max. 50 ma per output. Type summary esured value module DC 0...20 ma easuring range shunts for PT1.225 (standard packs of 10 pieces each) 1...5 ma 0...10 ma 0(4)...20 ma 0...25 ma PT1.225/020 PTR1.105 PTR1.010 PTR1.020 PTR1.025 esured value module DC 4...20 ma PT1.2420 Delivery Accessories Base and electronic module are supplied together but in separate boxes that are attached to one another. odule type PT1.225/20 is supplied with the shunt for 0...20 ma. f a module type PT1.225/020 is used with a measuring range other than 0...20 ma, the appropriate shunts must be ordered (see above). For general accessories that are used in connection with the /O modules, refer to data sheet N105. Such accessories must be ordered separately. Equipment combinations Automation stations Field units Basically, the /O modules can be connected to any automation station with P-bus if the automation station supports the /O functions on the software side. Refer to document Z102, "/O module system". Any units of the Siemens product ranges can be connected if their signals are compatible with the module's inputs and outputs. t is also possible to use products of other manufacture if their signals are compatible and if they satisfy the relevant safety requirements. Technical design With the PT1.225/020 module, the shunt used is not acquired by the automation station. Selection of the range 4...20 ma or 0...20 ma with the PTR1.020 shunt is made by the automation station. Note The whole functionality of the /O module comprises the module itself (hardware) and handling of the signals in the automation station (software). For a full understanding of the scope of module functions, the relevant process sequences and possible choices available when configuring the user program must be taken into consideration. For the technical features common to all /O modules, refer to document Z102, "/O module system". 2/6 Siemens Building Technologies easured Value odules C2N129en

echanical design odular unit with plastic casing, consisting of terminal base and electronic module which are plugged onto the /O bar. The signals and voltages are picked up from contacts on the /O bar. The connecting terminals of the /O modules arranged on the /O bar are used in place of the block terminals for the external wiring usually installed in the control panel. They comply with the relevant standards and regulations and provide the test terminal function. Also, they can be fitted with plant-specific labels. Transparent module front for insertion of the plant-specific module labels. The specifically prepared and perforated labels are marked with the help of the engineering tool for the building automation and control system. The space for the address plug is also on the front of the module. All /O modules use the same accessories, which are shown on Data Sheet 105. For a more detailed description of the module s mechanical design, refer to document Z102, "/O module system". 1 020 020 225 129Z01 225 1 2 PT1.225 PT1.2420 2420 129Z02 2420 1 2 Note Front views 1 Plug-in type measuring range shunts (0...20 ma as supplied) Siemens Building Technologies easured Value odules C2N129en 3/6

Engineering notes STOP Correct use The document Z102, "/O module system"contains system-related engineering knowhow. t should be studied before reading the following sections while paying special attention to the information relating to safety. Within the overall system, these /O modules must always be used on applications as described in document Z102, "/O module system. The module-specific characteristics and features given in the brief description on the front page and in the chapters "se", "Engineering notes" and "Technical data" of the present data sheet must also be taken into consideration. The sections of this chapter identified by a warning triangle contain additional requirements and restrictions relevant to safety. They must be observed to ensure the safety of persons and objects. easured value transmitters easured value inputs The measured value transmitters connected to the measured value modules must satisfy the requirements for safety-extra low voltage (SELV) or protection by extralow voltage (PELV) as per HD 34. The measured value inputs are not galvanically separated from the system's electronics. Burden Line lengths The burden specified under "Technical data" corresponds to the input resistance at the measured value inputs. The sum of line resistance and burden of the measured value module must be smaller than the maximum permissible burden of the measured value transmitter. Line lengths exceeding 300 m are permitted, but shielded cable will be required to reduce humming. Fitting notes Please refer to document 102, "/O modules and P-bus". f required, the measuring range shunts must be changed. With the PT1.225/020, the shunt used is not protected against incorrect wiring (e.g. against on 1 or 2, refer to "Connection diagrams"). nstructions for fitting the /O module on mounting rails and on the /O bar are printed on the packing. Commissioning note Please refer to document Z102, "/O module system. 4/6 Siemens Building Technologies easured Value odules C2N129en

Technical Data Power supply easuring range shunts Over- and underranges Resolution of converter Perm. input voltage Power supply for sensor (terminal ) Operating voltage Safety extra-low voltage SELV or protection by extra-low voltage PELV as per Frequency Power consumption /O module power supply via P-bus Load units easured value inputs PT1.2420 PT1.225/020 Current range (with shunts) Voltage Only for PT1.225/020 1...5 ma 0...10 ma 0(4)...20 ma 0...25 ma Burden with PT1.2l420 PT1.2420 PT1.225/020 1...5 ma 0...10 ma 0(4)...20 ma 0...25 ma 0...1 V With PT1.2420 With PT1.225/... sing 1...5 ma shunt sing 0...10 ma shunt sing 0(4)...20 ma shunt sing 0...25 ma shunt With 0...1 V voltage PT1.2420 PT1.225/020 (without shunt) Voltage range Perm. current rating At both terminals together At each terminal AC 24 V ± 20 % HD 34 50 Hz / 60 Hz 0.5 VA DC 24 V (against 0) 1(12.5mAeach) DC 4...20 ma DC 0...25 ma DC 0...1 V 200 Ohm 100 Ohm 50 Ohm 40 Ohm 100 Ohm +2.2...21. ma 0.5...+5.5 ma 1...+11 ma 2...+22 ma 2.5...+27.5 ma 0.1...+1.1 V 5 µa 1.562 µa 3.125 µa 6.250 µa 7.12 µa 0.312 mv DC ±7 Vmax. DC ±20 V max. DC 12...30 V 100 ma max. 50 ma max. Line lengths Perm. line lengths (due to humming noise) 300 m conformance n compliance with the directives of the European nion Electromagnetic compatibility 9/336/EEC Note For technical data common to all /O modules, refer to document Z102, "/O module system", and for dimensions refer to document 102, "/O modules and P-bus". Siemens Building Technologies easured Value odules C2N129en 5/6

Connection diagrams easured value module PT1.225/020 PT1.225 129A01 BS R1 R2 1 2 DC 0...25 ma DC 0...25 ma easured value module PT1.2420 PT1.2420 BS 129A02 1 2 DC 4...20 ma DC 4...20 ma easured value modules PT1.225/020, PT1.2420 R1, R2 easuring range shunts PTR1... (plug-in shunts) Bus /O bar with P-bus Power supply for measuring converter, 50 ma 1, 2 easuring current signals Connection examples for measuring converters PT1.2... R1 129A03 BS R2 PT1.2... 129A04 BS R1 1 2 1 2 1 2 AC 24 V 0 3 4 1 2 3 4 easuring neutral easured value modules PT1.225/020, PT1.2420 easuring converter with three-wire connection, power supply via measuring converter supply easuring converter with two-wire connection, power supply via measuring converter supply, with basic current of 4 ma (possible only with 4...20 ma range) easuring converter with external power supply, e.g. AC 24 V Voltage source connection DC 0...10 V, possible only with PT1.225/020 without shunt 6/6 1999 Siemens Building Technologies Ltd. Subject to changes Siemens Building Technologies easured Value odules C2N129en