How To Determine 14C



Similar documents
WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA

RADIATION MONITORING NETWORK OF THE CZECH REPUBLIC

Antoine Henri Becquerel was born in Paris on December 15, 1852

Q Environmental Emissions Data for Pickering Nuclear ONTARIO POWER GENERATION ONT

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

ORGANIC SAMPLE PREPARATION

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Ionizing Radiation, Czech Republic, CMI (Czech Metrology Institute)

Perspectives of a method for measuring soil-gas radon by an opened counting vial

CHEM 105 HOUR EXAM III 28-OCT-99. = -163 kj/mole determine H f 0 for Ni(CO) 4 (g) = -260 kj/mole determine H f 0 for Cr(CO) 6 (g)

IB Chemistry. DP Chemistry Review

Melting Point, Boiling Point, and Index of Refraction

Trace Gas Exchange Measurements with Standard Infrared Analyzers

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

Tutorial 4.6 Gamma Spectrum Analysis

Dissolved Mineral Radioactivity in Drinking Water

ISOLATION OF CAFFEINE FROM TEA

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Chemistry. The student will be able to identify and apply basic safety procedures and identify basic equipment.

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material)

10 Nuclear Power Reactors Figure 10.1

1. In the general symbol cleus, which of the three letters. 2. What is the mass number of an alpha particle?

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

EXAMPLE EXERCISE 4.1 Change of Physical State

Azeri, Chirag & Gunashli Full Field Development Phase 3 Environmental & Socio-economic Impact Assessment. A10.1 Introduction...

Experiment 7: Titration of an Antacid

Distillation of Alcohol

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

CHAPTER 10: INTERMOLECULAR FORCES: THE UNIQUENESS OF WATER Problems: 10.2, 10.6, , , ,

Physical Properties of a Pure Substance, Water

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

Prentice Hall. Chemistry (Wilbraham) 2008, National Student Edition - South Carolina Teacher s Edition. High School. High School

Balancing chemical reaction equations (stoichiometry)

Study of the selective determination of 90 Sr in environmental. and nuclear power plant samples

Determination of calcium by Standardized EDTA Solution

An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

- 1 - BISC 367 Plant Physiology Laboratory SFU

Recovery of Elemental Copper from Copper (II) Nitrate

Chemical Reactions Practice Test

NRC INSPECTION MANUAL INSPECTION PROCEDURE 88045

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

FOR TEACHERS ONLY. The University of the State of New York REGENTS HIGH SCHOOL EXAMINATION PHYSICAL SETTING/CHEMISTRY

DMA-1 Direct Mercury Analyzer

Assessment of environmental radiation monitoring data in Hungary following the Fukushima accident

Exp 13 Volumetric Analysis: Acid-Base titration

Properties of Alcohols and Phenols Experiment #3

1. The Determination of Boiling Point

Saturated NaCl solution rubber tubing (2) Glass adaptor (2) thermometer adaptor heating mantle

Automobile Air Conditioning Primer

Maine Yankee INDEPENDENT SPENT FUEL INSTALLATION (ISFSI) OFF-SITE DOSE CALCULATION MANUAL CHANGE NO. 32. Approved: Approval Date: 0"/06

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Nuclear Energy: Nuclear Energy

Remediation of VOC Contaminated Groundwater

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE CHEM COLLEGE CHEMISTRY I

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

MILESTONE H E L P I N G C H E M I S T S

Module No. # 02. Impact of oil and gas industry on marine environment

Treatment Centers for Radioactive Waste

Environmental Radiation Monitoring in Taiwan

Separation by Solvent Extraction

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

GUIDELINE FOR THE INSTALLATION AND OPERATION OF CONTINUOUS EMISSION MONITORING SYSTEMS (CEMS) AND THEIR USE FOR REPORTING UNDER THE PROVISIONS OF

Experiment 3: Extraction: Separation of an Acidic, a Basic and a Neutral Substance

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow

COUNCIL DIRECTIVE 2013/51/EURATOM

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

EnAlgae SOP: Biogas analysis

The Chemistry of Carbohydrates

Science Standard Articulated by Grade Level Strand 5: Physical Science

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

AMMONIA AND UREA PRODUCTION

ZAGRADA THE NEW ZAGREB RADIOCARBON DATABASE. Antun Portner Bogomil ObeliÊ 1 Ines Krajcar BroniÊ

ph Measurements of Common Substances

Hot water extractable acidity or alkalinity of paper (Reaffirmation of T 428 om-08) (No changes from Draft 1)

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

RADIATION MONITORING SYSTEMS

Emergencies Involving Radiation

Measuring volume of gas produced Measuring precipitation (because sulphur is produced) e.g. look for X to disappear Measure mass lost

Continuous flow direct water heating for potable hot water

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Material Safety Data Sheet Ampicillin, sodium salt MSDS

KODAK Developer System Cleaner and Neutralizer

United States Office of Radiation and October 1998 Environmental Protection Indoor Air Agency. Radiation and Indoor Environments National Laboratory

Summary Report of the EPRI Standard Radiation Monitoring Program

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS)

OPERATIONS MANUAL FOR BIOBASED PRODUCT CERTIFICATION PROGRAM

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Physical and Chemical Properties and Changes

For convenience, we may consider an atom in two parts: the nucleus and the electrons.

Radiation Monitoring System RMS

Oxygen Give and Take. Correlation to National Science Education Standards

Colorimetric Determination of Iron in Vitamin Tablets

Chapter 14 Solutions

F321 MOLES. Example If 1 atom has a mass of x g 1 mole of atoms will have a mass of x g x 6.02 x = 7.

Transcription:

DETERMINATION OF 14 C IN GRAB SAMPLES OF STACK AIR FROM NUCLEAR POWER PLANTS Ivo SvÏtlík 1,2 Petr Rulik 3 Václav Michálek 3 Lenka Tomášková 1 Ji í Mizera 1 ABSTRACT. At present, the most significant artificial sources of radiocarbon in the environment are effluents from nuclear energy facilities, even though they represent a minor contribution in comparison with the natural production of 14 C. Nevertheless, 14 C is a major contributor to the collective effective dose from all radionuclides released by nuclear power plants (NPP) with light-water pressurized reactors (LWPR) during normal operation. This paper aims to develop a 14 C determination method for grab samples from NPPs stack air. This method enables separate determination of 14 CO 2 and 14 C in combustible compounds. Treated samples are counted by LSC with an indication of interferences. Our results of 14 C activity concentrations in stack air grab samples are compared with results of 14 C determinations performed by the NPP s laboratory, which utilizes monthly/weekly accumulated samples. INTRODUCTION Currently, the most significant artificial sources of radiocarbon in the environment are effluents from nuclear energy facilities, even though they represent a minor contribution in comparison with natural 14 C production. Nevertheless, 14 C is a major contributor to the collective effective dose from all radionuclides released by nuclear power plants (NPP) with light-water pressurized reactors (LWPR) during normal operation (UNSCEAR 2000), as reported in Table 1 for 1990 1994. The Czech Republic has 2 LWPR-equipped NPPs, Temelin and Dukovany, with installed power outputs of 2 1000 MW and 4 440 MW, respectively. Table 1 Normalized collective effective dose from radionuclides released from nuclear reactors, 1990 1994, airborne effluents (UNSCEAR 2000). Collective effective dose per unit of electrical energy generated (man Sv [GWa] 1 ) Reactor type a Electrical energy generated (%) Radioactive noble gasses 3 H 14 C b LWPR 65.04 0.003 0.005 0.059 0.0001 BWR 21.95 0.15 0.002 0.14 0.0002 GCR 3.65 1.44 0.010 0.38 0.0004 HWR 5.04 0.23 1.4 0.43 0.0001 LWGR 4.09 0.19 0.05 0.35 0.002 FBR 0.24 0.042 0.10 0.032 0.0009 a LWPR light-water pressurized reactor; BWR boiling water reactor; GCR gas-cooled reactor; HWR heavy-water reactor; LWGR light-water, graphite-moderated reactor; FBR fast breeder reactor. b Local and regional components only. 131 I 14 C from the NPP s gas outlet can be captured from the surroundings or dissipated in the atmosphere, depending on the form of 14 C. The most stable chemical forms are hydrocarbons with prevailing 14 CH 4 (Kunz 1985), which is not significantly captured in the NPP vicinity and contributes to the increase of the 14 C activity level on a regional and/or global scale (Eisma et al. 1995). The 1 Department of Radiation Dosimetry, Nuclear Physics Institute AS CR, Na Truhlá ce 39/64, 180 86 Prague, Czech Republic. 2 Corresponding author. Email: svetlik@ujf.cas.cz. 3 National Radiation Protection Institute, Šrobárova 48, 10000 Prague, Czech Republic. 2006 by the Arizona Board of Regents on behalf of the University of Arizona LSC 2005, Advances in Liquid Scintillation Spectrometry Edited by Stanis aw Cha upnik, Franz Schönhofer, John Noakes. Pages 417 422.

418 I SvÏtlík et al. biota in the vicinity of NPPs takes in 14 CO 2 especially during calm weather, rainfall, haze, or atmospheric inversion. 14 C in the form of CO 2 is assimilated by plant photosynthesis and then transferred into the food chain. The abundance of 14 CO 2 in airborne effluents from LWPRs varies between 5 and 43% (Kunz 1985; Uchrin et al. 1992; EPRI 1995; Smith et al. 2002; Pintér and Molnár 1997; Molnár et al. 2005). This paper aims to develop a method of 14 C determination for NPPs stack air in order to determine an independent grab sample control. Experiments connected with the method development started in 2001. In the following years, grab sampling was performed at Czech NPPs. This method enables us to distinguish between 14 CO 2 and 14 C in combustible compounds, similar to the continual sampling routines in NPPs. SAMPLING Grab samplings were performed in the Temelin NPP for both reactors, HVB1 and HVB2. For HVB1, 2 samplings were done in 2002, 4 in 2003, and 3 in 2004; sampling for HVB2 started in 2004 (4 samplings). Stack air samples were collected into high-pressure stainless bombs (~200 atm). The apparent sampling time did not exceed 30 min. SAMPLE TREATMENT All samples were stored for at least 1 month to reduce the activity of short-lived radionuclides. In the laboratory, a gas sample was transferred into a low-pressure gas storage bag equipped with 2 inlet/ outlet tubings on opposite sides. The gas was passed through a gas-meter and traps with humidifying and washing solution (1% H 3 PO 4 ), sorption solution (3M NaOH), and a condensation flask with 1% H 3 PO 4 cooled solution (+5 C), to avoid water vapor condensation in other parts of the system. When a sample was transferred into a low-pressure bag, a cycling pump was connected between the condensation flask and the gas storage input. The gas then flowed from the bag s output into the gasmeter input. The pressure inside the gas-meter and flasks was lower than the atmospheric pressure, to avoid leaking of the gas sample. The total volume cycled corresponds to 13 volumes of a gas sample processed to reach a sufficiently high yield (above 98%) of CO 2 sorption in the NaOH solution. According to the sorption yield experiments, testing a single sample passage through a trap with NaOH (i.e. 1 sorption cycle), the yield was 33 36%, depending on the gas flow rate. Thus, longterm cycling allows us to achieve a high yield with negligible 14 CO 2 residue in the gas. To determine 14 C in combustible compounds, a catalyst (CuO, heated to 700 C) in a quartz tube was inserted between the cycling bag output and the gas-meter input. The solution with the 14 C sample was sequentially stripped by nitrogen (5.0 purity) to remove the residual radioactive noble gasses. After sample processing, the low-pressure gas storage bag was depleted and twice flushed out with nitrogen. Consequently, from the sample solution (apparent mass ~50 g) 8 g were repeatedly recovered into a 20-mL glass vial to prepare duplicate samples for measurement. The ph in the vials was gently reduced by diluted H 2 SO 4 dosed from a capillary tube onto the bottom while stirring, to avoid surface acidification resulting in CO 2 escape. To minimize chemiluminescence interferences, the final ph value was adjusted to 9.3, indicated by thymolftalein (solution color changed from blue to colorless). A background sample was prepared from 3M NaOH using the same routine after fossil CO 2 addition. Finally, 5 g of the sample solution was mixed with 15 ml of Hionic-Fluor (PerkinElmer, USA) scintillation cocktail in a 20-mL low-potassium glass vial. The yield of the sample treatment

Determination of 14 C in Stack Air from Nuclear Power Plants 419 was determined at random by the standard addition of a 14 C-labeled sodium carbonate solution into a fraction of the sample solution subsequently processed by the routine described above. To check the accuracy of the routine, barium carbonate was precipitated from a fraction of randomly selected samples. After the addition of a sodium carbonate carrier with a small controlled amount of 14 C, the precipitate was washed and dried, and 1 g was treated in an ultrasound bath with 7 ml of water. The yield from precipitation and washing was 97%. Finally, the carbonate sample was homogenized with 12 ml of an InstaGel (Packard Instrument Co., USA) cocktail. SAMPLE MEASUREMENT All samples including blanks and standards were counted for 60 min by a Tri-Carb 1050 or 3170 TR/SL in normal mode. Measurement of each sample series was repeated in 2-week intervals, 3 times at minimum. For carbonate solution counting, a counting window derived from the optimized one was utilized, with the lower edge above the maximum energy of tritium beta emission. Counting efficiency was determined individually, usually by standard addition (0.05 g of carbonate solution spiked with a known activity of 14 C) into the sample after the third counting. After each measurement, the spectra were checked in the region above the maximum energy of 14 C beta emission. Resulting count rates in parallel samples were compared; if a significant discrepancy was observed, a new sample solution treatment for LSC was performed. Such a case happened only 3 times during the entire experimental campaign. After the third measurement, count rates from each sample measurement with their combined uncertainties were compared. Significant differences in the results obtained could indicate the presence of interfering radionuclides with shorter half-lives and/or the instability of the sample scintillation mixture. Precipitate samples were measured for 60 min in a full 14 C counting window (channels 1 90), and quenching corrections depending on the tsie parameter were consequently performed. Table 2 Parameters of 14 C determination in carbonate solution and carbonate precipitate. Typical processed volume of stack air 150 350 L Sample cycling yield (on the base of residual activity determination) >98% Typical sample mass ( 14 C converted to carbonate in solution) 40 50 g Yield of the sample solution treatment (reduction of ph) 95.0 96.5% Counting efficiency (solution) 32.5 34.0% Background (solution) 6.5 cpm Yield of barium carbonate precipitation 97% Counting efficiency (precipitate) a 94 98% Background (precipitate) 8.5 cpm a Within the range of tsie values 200 175. In 2001, the laboratory was equipped with a Tri-Carb 1050; hence, the experimental results in Table 2 relate to this instrument. Later measurements of barium precipitate were performed on a Tri- Carb 3170 TR/LL purchased in 2004. For yield tracing and calibration ( 14 C-labeled sodium carbonate solution), radioactive standards were utilized of type ER 25, produced by the Czech Metrology Institute-Inspectorate for Ionizing Radiation, Prague.

420 I SvÏtlík et al. RESULTS Figure 1 illustrates results of the grab sampling of stack air from the reactor HVB1 in NPP Temelin, and its comparison with data from the continual sampling performed by the NPP s laboratory. 10000 1000 C-14 Bq.m -3 100 10 1 IV.01 XI.01 V.02 XII.02 VI.03 I.04 VIII.04 II.05 0 continual sampling (total 14C) grab sampling (total 14C) continual sampling (14CO2) grab sampling (14CO2) Figure 1 A comparison of 14 C activities (Bq/m 3 ) determined in stack air from continual and grab sampling in NPP Temelin, reactor HVB1. Table 3 presents 14 C activities determined in grab samples using both carbonate solution processing and carbonate precipitation procedures. Activities of total 14 C (Σ) were calculated from the determination of 14 C in combustible compounds and 14 CO 2. Table 3 A comparison of 14 C activities determined in HVB1 samples, Bq/m 3. Reported combined uncertainties correspond to ~68% probability. Carbonate solution Carbonate precipitate Sampling date Σ 14 C 14 CO 2 Σ 14 C 14 CO 2 4.II.2004 78.5 ± 3.7 56.9 ± 1.8 82.2 ± 5.0 52.6 ± 3.4 8.IX.2004 181.7 ± 4.7 2.7 ± 0.8 174.2 ± 8.9 3.6 ± 1.1 12.XII.2004 172.1 ± 4.3 7.1 ± 1.4 172.0 ± 7.3 5.5 ± 1.2 Results obtained by both methods agree well within the uncertainty margins. The relatively greater uncertainties associated with the carbonate precipitation method are due to only a minor part of the precipitate being measured during carbonate processing. The average activities were calculated from data from the NPP Temelin laboratory (i.e. continual sampling data of total 14 C and 14 CO 2 for HVB1 and HVB2). The abundance of 14 CO 2 was calculated from the averages. Data presented in Table 4 allow a comparison of the grab sampling with the aver-

Determination of 14 C in Stack Air from Nuclear Power Plants 421 age values for continual sampling in HVB1 and HVB2 from May 2002 to December 2004 and February to December 2004, respectively. The grab sampling averages were calculated from the values determined by the carbonate solution counting. Combined uncertainties of determination did not exceed 15% for activities above 10 Bq/m 3. Table 4 Observed average activities in stack air grab samples from HVB1 and HVB2 compared with results of the continual sampling in the given time periods. Sampling Σ 14 C (Bq/m 3 ) 14 CO 2 (Bq/m 3 ) 14 CO 2 (%) Grab, HVB1 348 (169 a ) 15.6 (7.6 a ) 4.5 (4.5 a ) Continual, HVB1 (V/02 XII/04) 234 9.3 4.0 Grab, HVB2 186 6.8 3.6 Continual, HVB2 (II/04 XII/04) 289 6.9 2.4 a Data reported in parentheses were calculated after discarding outlying values (couple): total 14 C, twice sampled 12.XII.2003, 1-hr interval; 14 CO 2, sampled 4.II.2004. Short-time pulses of 14 C activity may have been the reason for the higher average activity found in the grab samples from HVB1 (see Figure 1). Such a pulse was observed on 12.XII.2003, and could be connected with some routines of servicing operation. At that time, the stack air was sampled twice, in 1-hr intervals. The observed activity of 14 C combustible compounds decreased from 1482 to 520 Bq/m 3 during 1 hr, without a sharp change of 14 CO 2 activity (from 22.1 to 15.6 Bq/m 3 ). Continual sample cumulating 1, performed by the NPP, includes these short-lived 14 C pulses. During the grab sampling, there is only a small probability for short-lived pulse detection, as is made obvious by the average activities in HVB1 after discarding the outlying values (72% of total 14 C, 82% of 14 CO 2 ). The average total 14 C activity in HVB2 (but only from 4 results) can probably confirm this effect as well (64% of total 14 C). However, the observed average activity of 14 CO 2 is closer to the continual sampling results from HVB2. The percentage of 14 CO 2 activity, calculated from the grab sampling averages, exceeds that measured by the continual monitoring in HVB1 and HVB2 by 0.5% and 1.2%, respectively. Results obtained in the grab sampling could also have been influenced by the high-pressure sampling and by procedures applied in the processing of relatively small grab samples. Nevertheless, the results from continual and independent grab sampling confirm a relatively small percentage (<5%) of 14 CO 2 in the airborne effluents from NPP Temelin. CONCLUSION Several grab samplings of stack air from reactors HVB1 and HVB2 in NPP Temelin were performed. On the basis of 14 C determination in combustible compounds and 14 CO 2, average activities determined in the grab sampling were below average values determined by continual monitoring during the relevant period. The maximum difference (36% of total 14 C) was found in HVB2. After discarding of outliers, the average values in HVB1 are below the continual sampling for total 14 C and 14 CO 2 by 28% and 18%, respectively. These differences can be caused by short-lived pulses of 14 C activity, as observed in samplings repeated with 1-hr intervals on 12.XII.2003. Since the grab sampling results are affected by short-lived variations of 14 C activity, the data from the continual sampling are more representative for calculation of 14 C releases. For the purpose of an 1 Samples were cumulated during 1 week or several weeks.

422 I SvÏtlík et al. independent control of 14 C amount in the airborne effluents, the grab sampling results can be utilized for a comparison only as a basis for a greater number of samplings performed. Nevertheless, the resulting abundances of 14 C in the CO 2 chemical form have been found to be close to the results of the continual sampling. Part of the 14 C in this form is captured by biota in the surrounding environment and is consequently transferred into the food chain. Ingestion of 14 C represents 99% of the collective effective dose from this radionuclide intake (UNSCEAR 2000). Regarding the released quantity of this radionuclide, the abundance of 14 CO 2 can be validated without additional data about the volume of stack air released. REFERENCES Eisma R, Vermeulen AT, van der Borg K. 1995. 14 CH 4 emissions from nuclear power plants in northwestern Europe. Radiocarbon 37(2):475 83. EPRI [Electrical Power Research Institute]. 1995. Characterization of C-14 generated by the nuclear power industry. Report EPRI TR-105715. Palo Alto, California, USA: EPRI. Kunz C. 1985. Carbon-14 discharge at three light-water reactors. Health Physics 49:25 35. Molnár M, Szántó Z, Svingor É, Palcsu L, Futo I, Elekes Z. 2005. Measurement of beta-emitters in the air around the Paks NPP, Hungary. In: Olariu A, Stenström K, Hellborg R, editors. Proceedings of the International Conference on Applications of High Precision Atomic and Nuclear Methods. Neptun, Romania, 2 6 September 2002. p 32 8. Pintér T, Molnár M. 1997. Radiocarbon in primary water, stack air and waste streams of Paks, Bohunice and Krsko nuclear power plants. In: Proceedings of the 3rd International Seminar on Primary and Secondary Side Water Chemistry of Nuclear Power Plants. Paks, 16 20 September 1997. Smith G, Merino J, Kerrigan E. 2002. Review of C-14 inventory for the SFR facility. 2002:14 report of the Swedish Radiation Protection Authority. URL: http:// www.ssi.se/ssi_rapporter/pdf/ssi_rapp_2002_14.pdf. Uchrin G, Hertelendi E, Volent G, Slavík O, Morávek J, Kobal I, Vokal B. 1998. 14 C measurements at PWRtype nuclear power plants in three middle European countries. Radiocarbon 40(1):439 46. UNSCEAR [United Nations Scientific Committee on the Effects of Atomic Radiation]. 2000. Exposures from man-made sources of radiation. Report 1, Annex C. 134 p. URL: http://www.unscear.org/docs/reports/annexc.pdf.