Overview and Update on Street Lighting Luminaire Standards and Code of Practices

Similar documents
STREET LIGHTING CONSTRUCTION DESIGN CRITERIA

Light First Social innovation through lighting

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

English version. Road lighting - Part 2: Performance requirements

Industrial Linergy LED

T5 LongLast. GE Lighting DATA SHEET

nano led THE GREEN LIGHT

Outdoor Workplace Lighting according to CIE S 015:2005 / pren

Solid State Lighting Definitions for Functional and Decorative Applications

Lemnis public lighting BETTER VISIBILITY WITH LESS ENERGY

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

Robust and waterproof

T5 Watt-Miser Linear Fluorescent lamps

Evolve LED Area Light

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

V anguard. applications 5.1. vanguard vanguard. Assembly lines. Production areas. Gymnasia. Swimming pools. Clean areas. Food processing areas

Session 15 Lighting Fundamentals

Linear Luminaire with LED Series EXLUX 6402/2

Vehicle Circulation Areas - OPT 3 (Rev 00)

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

ALARI LED PARKING, ROADWAY & AREA LIGHTING

STANDARD SPECIFICATIONS FOR SIGNAGE, STRIPING, AND LIGHTING TOWNSHIP OF STANFORD

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Evolve LED Area Light

Lighting tools. for the future LARGE BELL LED SMALL BELL LED

IVIOS LED III. LUM Technical Information

LED Street Lighting Pilot Project Overview

Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry

PUNKT LAMP 150 Design: focus lighting

120W High Bay II Datasheet

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Prepared for Local Government Association of SA

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Contrast 2 LED. Performance Compactness Complete flexibility NEW

JD(Doug) Rooks Western Area Applications Manager

DuroSite TM High Bay Lighting

LED Tubular Lamp / Kit Guide

High Bay Occupancy Sensor Selection Guide

AOK i Series LED High Bay / Flood / Tunnel Light

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment

IPS HIGH-BAY / LOW-BAY LIGHTING

High Pressure Mercury

P850 Next Generation LED Luminaire with AeroFlow Cooling System

MAGNA PARK Extension. Report. DHL SUPPLY CHAIN: External Lighting Strategy. June

Flexible LED system approach

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

LED Luminaire Design Guide

THE MAINTENANCE FACTOR FOR LED LIGHTING

Introduction. Terms. LED Application Series: Outdoor Area Lighting

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Kolorlux. GE Lighting DATA SHEET

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

The Latest in LED Lighting Test Methods and Standards. Jianzhong Jiao, Ph.D. OSRAM Opto Semiconductors Inc.

ponto CHARACTERISTICS - FLOODLIGHTS DESCRIPTION ADVANTAGES VARIANTS

A Guide to the Specification of LED Lighting Products 2012

KATO. LED Lighting High Bay und Low Bay

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Experiences of LED Lighting Products

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

LG LED Road & Street Lighting

Video Conference Indirect Wash LED Fixture

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Realtime Distance Learning For Lighting-Involved Professionals

LIGHTING and LIGHTING SYSTEMS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

CITY OF ST. CLOUD LED LIGHTING

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Lumination LED Luminaires

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

LED light engine / OLED LED flexible. Umodule LLE-FLEX umodule LLE FLEX ADVANCED

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

Lumination LED Luminaires

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

ORDER DIRECTLY TODAY AT:

9W T8 LED TUBE 2FT GENERAL INFORMATION

Features. High Brightness LED Light source

design Mario Cucinella MAXIWOODY

Lighting with Artificial Light

LED/SSL Light Sources and LED/SSL Luminaires Lifetime and Lumen Maintenance

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

DOSSIER EN m CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012

Evolve LED Roadway Lighting

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

OUTDOOR LIGHTING REGULATIONS

ETC130 / 140 Inground Uplights - Gimbal LED. Presentation Overview

Guide to new, energy-efficient lighting technologies for your business

Transcription:

Overview and Update on Street Lighting Luminaire Standards and Code of Practices P.K.Bandyopadhyay, Chairman, Illumination Engineering Sectional Committee, BIS Chennai, 21 st March, 2013

ENERGY SAVING OPTIONS STREET LIGHTING Use of energy efficient lighting Design based approach Regulating power parameters to suit the actual requirements Providing guidelines on usage of quality Material Controlling the burning hours of the lamps

INDIAN STANDARD IS 10322( Part 5/Section 3) Safety Requirements Performance Requirements (Photometry) IS 13383 (Part 2) Methods of Photometry of Luminaires Standard Harmonized with IEC 60598-2-3 Method of Test for Photometry as per CIE Publication

CODE OF PRACTICE IS 1944(Part I) : General Principles IS 1944(Part 2) :Lighting for Traffic Routes (Group A1, A2, B1 and B2) IS 1944 (Part 5): Lighting for Grade Separated Junctions, Bridges and Elevated Roads (Group D) IS 1944 (Part 6): Lighting for Town and City Centres and Areas of Civic Importance ( Group E ) IS 1944 (Part 7)Lighting for Roads with Special Requirements ( Group F ) National Lighting Code Codes are based on CIE Publications

ROAD AND STREET LIGHTING LUMINIARE STANDARD Construction IP Classification Static Load Test Wind Force test General construction Creepage Distances and Clearances Provision for Earthing Terminals External and internal wiring

ROAD AND STREET LIGHTING LUMINIARE STANDARD Protection against electric shock Endurance tests and thermal tests Resistance to dust and moisture Insulation resistance and electric strength Resistance to heat, fire and tracking

SALIENT ASPECT OF LIGHTING CODES Classification of Installation Basis of lighting requirements Classification of Lighting Public Lighting Aims of Public Lighting Principles of Vision in Public Lighting Requirement of Driver Visual field of Driver Visibility Glare and Visual Comfort

SALIENT ASPECT OF LIGHTING CODES Criteria of Quality Level of luminance, Uniformity of luminance, Limitation of glare, and Visual Guidance Electric Light Sources Luminous flux, Economy (determined by lumens/watt and life ), Dimensions of the light sources, and Colour characteristics

SALIENT ASPECT OF LIGHTING CODES Types of Light Sources Incandescent Lamps Mixed Incandescent and High Pressure Mercury Vapour Lamps High Pressure Mercury Vapour Lamps With Clear or Fluorescent Bulbs Tubular Fluorescent Lamps Sodium Vapour Lamps Mercury-halide Lamps, and High Pressure Sodium Vapour Lamps LED Induction Lamps

SALIENT ASPECT OF LIGHTING CODES Selection of Luminaire Nature and power of the source or sources Nature of the optical arrangements and the light distribution which they provide Light output ratio Whether the luminaire is open or closed type Resistance to heat, soiling and corrosion

SALIENT ASPECT OF LIGHTING CODES Selection of Luminaire Resistance to atmospheric condition (IP) Ease of installation and maintenance Presence or absence of auxiliaries Fixing arrangements, the weight and area exposed to wind pressure Cut-off luminaires Semi-cut-off luminaires Non-cut-off luminaires

SALIENT ASPECT OF LIGHTING CODES Aesthetics Design and Siting Columns and Surroundings Size and type of Luminaires Forms of Bracket Assembly of Column, Bracket and Luminaire Arrays of Luminaires Material, Finish and Colour of Column and Bracket

SALIENT ASPECT OF LIGHTING CODES Clearance between Column and Carriageway Maintenance Breakdown Preventive

LIGHTING REQUIREMNTS FOR TRAFFIC ROUTES Classification Of Lighting Installation Group A1,A2,B1,B2 Type of Roads Choice on the Type of Luminaire Cut-off Semi-cut-off Non- cut-off

PHOTOMETRIC REQUIREMENTS Average Value of Road Illumination on Road Surface Uniformity Ratio Transverse Ratio of Illumination

SITING OF LUMINAIRE Type of Arrangement Single sided Staggered Opposite Axial Mounting Height Spacing and Space Height Ratio Outreach and Overhang of Luminaire

SITING OF LUMINAIRE AT SPECIAL FEATURES Curves Crossroads Pedestrian Crossing Intersection T-Junction Roundabouts Transition Zone Treatment of Gradient

NATIONAL LIGHTING CODE Primary Objective of the Code: Energy saving through selection of efficient lamp technologies and design practices Capital cost saving using proper spacing and placement Maintenance cost saving using lamps with longer life and optimum spacing Reduced glare and improved visibility by careful selection of luminaries and lamps

NATIONAL LIGHTING CODE Improved sense of security by selection of efficient system and incorporating proper design. This can make an area appear safer and more secure Improved sense of economic development of communities Improved safety of motorists, cyclists and pedestrians, improved traffic guidance and a pleasant environment

NATIONAL LIGHTING CODE Design Principles Requirements of Road Users Fundamental Quality Criteria Luminance level Illuminance level Illuminance uniformity Degree of glare limitation (Bad, Moderate and Good)

NATIONAL LIGHTING CODE Visual guidance Positioning of poles Using different lamp colours Use of high masts (>20m) Surround Ratio

NATIONAL LIGHTING CODE Effect of Road Surface Defining Road and Pole Installation Carriageway Type of Pole Configuration Type of Pole Arrangement Single sided Opposite sided Staggered Twin-Central and Opposite Arrangement

NATIONAL LIGHTING CODE Preferred Pole Location Trace the traffics flow and direction Try to follow the shape of the road along with the traffic flow Reduce spacing near bends For complex multi level junctions, high mast lighting preferred instead of array of poles

NATIONAL LIGHING CODE Lighting Parameters Luminance Illuminance

CLASSIFICATION OF ROADS Description of Roads High speed roads with separate carriageway, free of crossings at grade and with complete access control, motorways, express roads. Traffic density and complexity of road layout. High Medium Low Lighting Classification M1 M2 M3

CLASSIFICATION OF ROADS Description of Roads High speed roads, dual carriageway roads, traffic control, such as the presence of signals, and separation of different types of road user into lanes. Poor Good Important urban traffic roads, radial roads, distinct distribution roads. Traffic control and separation of different types of road users. Poor Good Lighting Classification M1 M2 M2 M3

CLASSIFICATION OF ROADS Lighting Description of Roads Connecting less important roads, local distributor roads, residential major access roads, roads which provides direct access to property and lead to connecting roads. Traffic control and separation of different types of road user. Poor Classification M4 Good M5

LIGHTING RECOMMENDATIONS FOR Lighting Class DIFFERENT ROAD TYPES-CIE CLASSIFICATION All Roads Roads with few Junctions TI (%) (max) Roads with Footways Surround Ratio (SR) L av U O U L (min) M1 2.0 0.4 0.7 10 0.5 M2 1.5 0.4 0.7 10 0.5 M3 1.0 0.4 0.5 10 0.5 M4 0.75 0.4-15 - M5 0.5 0.4 0.4 15 -

Lighting Recommendations for Different Road Types-IS Classification Classification of lighting installation Type of road Group A1 Important traffic routes carrying fast traffic Group A 2 Other main roads carrying mixed traffic like main city streets, arterial roads and throughway roads Average illuminance Uniformity Ratio Transverse Uniformity on road Emin/Eav (E min/e max) surface 30 0.4 0.33 15 0.4 0.33

Lighting Recommendations for Different Road Types-IS Classification Classification of lighting installation Type of road Average illuminance on road surface Uniformity Ratio Emin/Eav Transverse Uniformity (E min/e max) Group B 1 Group B 2 Secondary roads with considerable traffic like principal local traffic routes and shopping Secondary roads with light traffic 8 0.3 0.2 4 0.3 0.2

LIGHTING RECOMMENDATIONS FOR JUNCTIONS Junction Type E av (Lux) Emin/Eav Key Junctions & Complex Flyover 50 0.4 interchanges Main City Junctions without any 20 0.4 interchanges Other smaller junctions 15 0.4 Pedestrian Crossings 50 * - Bus Bays 5 -

MAINTENANCE FACTOR Cleaning Interval in months MIN IP 5X MIN IP 6X Pollution Category Pollution Category High Medium Low High Medium Low 12 0.89 0.90 0.92 0.91 0.92 0.93 18 0.87 0.88 0.91 0.90 0.91 0.92 24 0.84 0.86 0.90 0.88 0.89 0.91 36 0.76 0.82 0.88 0.83 0.87 0.90

LIGHTING SYSTEM SPECIFICATION Luminaire Housing Optical System Lamp Controlgear Ballast Ignitor Capacitor

SELECTION CRITERIA OF LUMINAIRE Mechanical Electrical Required lamp types Ambient operation temperature Required IP rating Air resistance, with/without bowl, with/without gear unit Component exchangeability, accessories Mounting functionality Material requirement

SELECTION CRITERIA OF LAMPS Colour temperature (T c ) Colour rendering (CRI) Lumen output Lamp efficacy Lumen depreciation Lamp life (hours)

CONTROL SYSTEM Control Switch Time Switch Photo Electric Switch Computerized Switch Step Dimming Step Dimming ballast. Preprogrammed Timer. Power factor improvement capacitor. Semi-parallel ignitor Tele Management

PHOTOMETRIC SPECIFICATION Key Elements Type of distribution Luminaire efficacy Need for optic or lamp position adjustment Lighting Control Elements Reflector Refractor Diffuser Filter Screening Device

LUMINAIRE PHOTOMETRIC PRINCIPLE Throw: The extent to which the light from the Luminaire is distributed along a road Spread: The amount of sideways spread of the light, across a road Control: The extent of the facility for controlling glare from the Luminaire

EVALUATION OF GOOD ROAD LIGHTING INSTALLATION Total cost of ownership Preparation phase: Design, purchase and installation cost = Initial Investment Running phase: Energy cost and maintenance cost Total cost =Investment + Energy + Maintenance

ECONOMIC SOLUTION FOR COST REDUCTION Reducing investment Costs: Increase luminaire spacing Use single sided or central arrangement Use of energy efficient luminaire Use existing cable and photo cell Post top luminaire mounting

ECONOMIC SOLUTION FOR COST REDUCTION Reducing Energy Costs: Install the most efficient lighting system = lamp efficacy and luminaire application efficiency (for example using adjustable optics) Choice of maintenance factor (lamp depreciation and IP factor)

ECONOMIC SOLUTION FOR COST REDUCTION Reducing Maintenance Cost Minimize number of light points by increasing luminaire spacing Lamps with long life and low early failure rate Conscious decision for group or spot replacement Reliable, longer life controlgear Luminaire with high IP rating Luminaire which is easy to maintain

APPROACHES TOWARDS MASTER PLAN For some roads technical specs are of first priority and for some other roads aesthetics is of first priority Technical Specifications required for: Ring Roads /Peripheral Expressways City Roads, Main Vehicular Traffic Residential Roads Aesthetics is required for the following roads: Heritage Roads / Celebration Routes City Centre /Shopping Areas/Pedestrian Plaza

APPROACHES TOWARDS MASTER PLAN The aesthetics can be achieved by selecting one or more of the following procedures: Different Lighting Levels Different Shape of Luminaires Different Pole design Different Pole Arrangement

MEASUREMENT CIE Method Field Measurement

THANK YOU