Power factor correction. An introduction to technology and techniques

Similar documents
ECA272. The Enhanced Capital Allowance scheme for energy-saving technologies

The Enhanced Capital Allowance scheme for energy-saving technologies. A guide to equipment eligible for Enhanced Capital Allowances

Energy Efficiency Financing Unlock opportunities for additional sales. Supplier benefits. Financial Services provided by

Power Factor Correction for Power Systems First Semester Report Spring Semester 2007

Fact sheet. Conversion factors. Energy and carbon conversions 2011 update

How To Boost Your Cash Flow With The Enhanced Capital Allowance Scheme

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Advanced metering for SMEs

The Enhanced Capital Allowance scheme for energy-saving technologies

It doesn t take much energy to get a tax break

POWER FACTOR CORRECTION

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS

Heating, ventilation and air conditioning zone controls

Power Factor The Basics

How to monitor your energy use

Three phase circuits

7. Reactive energy compensation

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

Electricity Terminology. Simplifying energy management

Motor Efficiency and Power Factor ME 416/516

factor max Delivering Electrical Efficiency INFORMATION PACK factor max

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Application Guide. Power Factor Correction (PFC) Basics

A guide to reactive power

Power Factor in Electrical Energy Management

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Module Title: Electrotechnology for Mech L7

Critical thin-film processes such as deposition and etching take place in a vacuum

Energy Cost Reduction through Load Balancing & Load Shedding

Energy Saving Fact Sheet Energy Management

How To Understand And Understand The Theory Of Electricity

Improvement of Power Factor for Industrial Plant with Automatic Capacitor Bank

VOLTAGE REGULATOR AND PARALLEL OPERATION

RLC Resonant Circuits

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Inverter technology. bulletin

Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture phase System 4

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Rotary Phase Converters

11. Assessment of service 12. S-phase supply 13. Water heaters NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS

Managing new connections for your business. A guide to establishing a new electricity supply

SYNCHRONOUS MACHINES

Explaining How Voltage Optimisation Can Save Energy and Protect Your Site

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Lecture Notes ELE A6

Simulation of Cable Overloading Problem on a University Distribution System

ROYAL MAIL GROUP ADDRESS MANAGEMENT UNIT PAF DIRECT END USER LICENCE

Introduction. Harmonics and IEEE 519 Page 1 of 19

Impedance Matching. Using transformers Using matching networks

Series and Parallel Circuits

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

Fig.1 block of PFC using PIC. Index Terms:-power factor, PIC, Hardware

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Calculating Total Power Requirements for Data Centers

Product Data Bulletin

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

(3 )Three Phase Alternating Voltage and Current

The Different Types of UPS Systems

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

Prepared By: Sheilani Binti Shaari Department of Electrical Engineering/PKB

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

Analysis of Energy Consumption. ACME Limited

Power surges can also be generated by equipment in your facility such as:

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Chapter 11. Inductors ISU EE. C.Y. Lee

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

High Voltage Power Supplies for Analytical Instrumentation

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION

Statement Of Work Professional Services

A Low Cost Power Quality and Energy Savings Laboratory for Undergraduate Education and Research

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Energy Saving Fact Sheet Boilers

Managing bills and bank accounts

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Inductors & Inductance. Electronic Components

UPS Applications and VRLA Battery Sizing

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Saving Energy For Your Organisation. Top 10 energy saving tips

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

The Case for Renewables in UK Business

Power Supplies. 1.0 Power Supply Basics. Module

NATIONAL CERTIFICATE (VOCATIONAL)

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

ALL ABOUT LOAD SERVICE APPLICATION HOW-TO QUICK GUIDE

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

Standard Electricity Prices and Charges *

Lecture - 4 Diode Rectifier Circuits

Apprentice Telecommunications Technician Test (CTT) Study Guide

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Energy Saving Fact Sheet Air Conditioning

Definitions. Broker means Veda Advantage Information Systems and Solutions Limited;

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Transcription:

Power factor correction An introduction to technology and techniques

2 Contents Understanding power factor 03 Power factor correction 05 Implementing power factor correction techniques 06 Glossary 07 Further services 08

3 Reducing energy use makes perfect business sense; it saves money, enhances corporate reputation and helps everyone in the fight against climate change. The Carbon Trust provides simple, effective advice to help businesses take action to reduce carbon emissions, and the simplest way to do this is to use energy more efficiently. This technology guide introduces power factor correction, discussing practical action that organisations can take. Understanding power factor What is power factor? Power factor is a way of describing how efficiently electrical power is consumed. It refers to power in an alternating current (AC) electrical circuit, either for a single piece of equipment or all of the electrical equipment at a site. The power that is drawn from the network can be described as consisting of two parts useful power and reactive power. Useful power is the power that equipment needs to achieve the task at hand and it is measured in kw. Reactive power is drawn in addition to useful power by a reactive load and is measured in kvar. The consumption of reactive power does not contribute to achieving the task. The useful power and the reactive power together determine the power drawn from the network, that is, the total power (also known as apparent power), measured in kva. is not the linear sum of useful power and reactive power. However, lessening the effects of reactive power will reduce the current needed from the network to complete the same tasks. Power factor is the ratio of delivered useful power to the total power taken from the supply. An ideal ratio is 1.0, that is, a perfect match between power drawn from the network and useful power for the task. This is also known as unity power factor. In reality, many loads do not easily achieve unity power factor due to their inherently reactive nature. However, it is possible to compensate for the reactive power. By doing so, less power will be needed from the network to achieve the same tasks, resulting in energy and cost savings. If the ratio is under 0.85, the power factor is generally considered to be poor. Correction would typically achieve 0.95-0.98.

4 How is poor power factor caused? Figure 1 shows the relationship between useful and total power. The length of the heavy black line represents the useful power consumed by a 100kW machine, while the red line shows the power taken from the electrical system. The angle in the diagram ( ) shows the extent of the difference. In this diagram, significantly more power is needed to deliver 100kW of useful power 1. Figure 1 Relationship between total power and useful power kva Useful power kw 100 kw Power factor = Useful power = cos Reactive power kvar Reducing the effects of reactive power will cause the angle to get closer to 0º, meaning the power factor will get closer to unity. Power factor correction techniques can achieve this. Poor power factor has negative implications for businesses because it: Draws more current from the network costing more to achieve the same tasks. Can incur a poor power factor penalty from the supplier, sometimes called a reactive power charge. Reduces the effective capacity of the electrical supply, the more reactive power that is carried, the less useful power can be carried. Causes losses at transformers and other devices, leading to inefficiency and unwanted heat gains. Can cause excessive voltage drops in the supply network. Can reduce the life expectancy of electrical equipment in extreme cases. Which devices could have poor power factor? Reactive power will be consumed by all uncorrected reactive devices it is just a part of how they work. Commonly-used inductive devices include motors, welding sets, induction heaters and fluorescent lights. Inductive loads are not always easily identifiable, and the most certain way of identifying them is through a power factor survey. 1 here calculated as 100 cos.

5 Power factor correction What is power factor correction? Power factor correction (PFC) techniques aim to bring the power factor closer to unity by reducing the effects of reactive power. In the great majority of cases, poor power factor is due to inductive loads which can be compensated by adding electrical devices called capacitors into the circuit. The diagrams in Figure 2 show the effect of PFC on the poor power factor example shown in Figure 1. In Figure 2A, with the capacitors, the angle is reduced, therefore the total power drawn from the supply is less. However, there is still a lagging power factor. Figure 2B shows how the addition of more capacitance brings the total power drawn nearly down to a perfect power factor. However, it is possible to overcompensate. Figure 2C shows how too much capacitance can lead to overcorrection and, again, draw excess power from the network. This is called a leading power factor. Figure 2A Some capacitors fitted a Figure 2B Near perfect power factor correction with capacitors a (no capacitors) Useful power (no capacitors) Useful power c (capacitors fitted) d b 100 kw c (more capacitors fitted) d b 100 kw Figure 2C Over-correction of power factor Advantages of PFC a By reducing losses and inefficiencies, improving your power factor means you need to draw less from the network, saving you money on your electricity bill. Power factor correction (PFC) can prolong the life of electrical equipment. It can help avoid voltage drops over long cables and reduce efficiency losses in your supply transformers. PFC will increase the effective capacity of your local electricity network potentially deferring future investment in electrical infrastructure and allowing you to connect more machinery to the same utility connection. Where to look for power factor information Equipment specifications Nameplates or specification manuals will include power factor specifications. Be careful about how they represent the figure some may show the figure for power factor, while some will just show the angle 2. Utility bills Depending on the contract, some suppliers may charge for reactive power use, and/or add a penalty for poor power factor. This should be identified on the invoice. Power factor surveys Power engineering specialists and electricians can conduct a survey to check for poor power factor. Some utility companies and suppliers will perform a survey at no cost and make recommendations. Fact: (no capacitors) (too many capacitors fitted) c 100 kw Useful power It is not uncommon for industrial installations to be operating at power factors between 0.7 and 0.8 which is relatively poor. d b 2 The power factor will be represented as the cosine of the angle cos. If the product just quotes the angle, use a scientific calculator to determine the cosine value.

6 Implementing power factor correction techniques Understanding the system The specification of a PFC system requires knowledge of several factors including: The voltage level and typical usage of the reactive loads on-site This will affect the type of system and the amount of correction needed. Adding capacitors is a basic PFC technique, but other systems might be more appropriate in some circumstances. For instance, active PFC is an electronic PFC system that controls the amount of power drawn by a load in order to obtain a power factor as close as possible to unity. In most applications, the active PFC system controls the input current to the load using power electronics. However, active PFC systems can also be tailored to provide varying PFC characteristics for sites with unique profiles and power constraints. The usage profile across the site This is particularly important if PFC equipment has been installed at some time in the past and the electrical requirements have changed since, for example, by the substitution or addition of some machinery. If so, have the power factor resurveyed. The power quality required by the on-site loads Equipment generally needs a high quality supply with stable characteristics that is a pure supply. Improperly specified, PFC can introduce harmonics, where unwanted voltages at various frequencies can be superimposed onto the mains voltage. Adverse effects caused by harmonics include heating of equipment and electromagnetic interference, such as that to communication systems, telephones, radio, TV and computers. In extreme cases, it can lead to failure of equipment. Additional equipment, such as line filters can smooth the mains voltage to reduce any prominence of harmonics. PFC equipment The simplest form of PFC involves fitting capacitors. Many PFC devices exist to accommodate each type of situation. It is worth shopping around specialist companies and taking expert advice on the system that will suit you. If a single machine has a poor power factor, capacitors can be connected in parallel with the device, that is, connected to the live and the neutral terminals of the reactive device, so that they compensate for the poor power factor whenever the machine is switched on. This is a form of fixed PFC. If the power factor at a site is permanently poor and no single item of equipment is solely responsible, fixed PFC can be employed also. In this case, the PFC capacitors will be connected across the main power supply to the premises, that is, the capacitor banks terminals are connected to each of the three phase cables as they enter the site. In this case, PFC can be linked with the switchgear. However, there are other circumstances where PFC is not so straightforward. Where many machines are switching on/off at various times, the power factor may be subject to frequent change. In these cases the amount of PFC needs to be controlled automatically that is, the banks of capacitors need to be selectively switched in and out of the power circuit appropriately. There are various solutions on the market for automatically controlled PFC. Remember PFC equipment has a finite life an older installation may not be operating as originally intended. Always talk to your supplier to find out how often equipment should be checked and, if an installation is over 20 years old or if the layout has changed, consider having the equipment overhauled and site resurveyed to investigate potential improvements. Safety first It is important to consult qualified personnel prior to the specification and installation of any PFC system. Only appropriately trained and qualified people should specify or fit PFC equipment, or take electrical measurements.

7 Glossary Active power Apparent power Capacitor Harmonics Line filter Power factor Power factor correction (PFC) Reactive load Reactive power Resistive loads See useful power. See total power. An electrical device which can compensate for the effect of reactive power caused by inductive loads. Troublesome voltages at multiples of the mains frequency (50Hz) that can be introduced into an electricity supply by the presence of certain equipment, including inappropriately specified PFC equipment. A device that smooths the mains voltage to reduce the prominence of harmonics. A line filter is sometimes used in conjunction with PFC equipment to ensure there are no harmonic generation issues. The ratio of useful power to total power as drawn from an AC supply by an electrical device or installation. Power factor can also be expressed as the cosine of the angle that exists between total power and useful power vectors. A technique to compensate for poor power factor and thereby optimise the transfer of useful power into electrical equipment. A load characterised by the presence of an inductance or capacitance, such as is present in induction heaters, motors, fluorescent lights and welding sets. It consumes reactive power as well as useful power. Power that is consumed by the reactive nature of a device yet produces no useful work; can be either inductive or capacitive and is measured in kvar. A purely resistive load possesses no reactance, that is, it draws no reactive power and therefore has a power factor of 1.0 (or unity). Examples of resistive loads are incandescent lighting and resistive heating elements. The total power drawn by a device or installation including that consumed by its reactive nature; units in kva (thousands of Volt Amps). Also known as apparent power. Unity A term sometimes used to describe ideal power factor ratio, that is 1.0. Useful power Power that is consumed by a device when doing useful work. Note that, depending on the efficiency of the device itself, not all of the useful power is actually converted to work. Also known as active power.

8 Further services from the Carbon Trust The Carbon Trust advises businesses and public sector organisations on their opportunities in a sustainable, low carbon world. We offer a range of information, tools and services including: Website Visit us at www.carbontrust.co.uk for our full range of advice and services. www.carbontrust.co.uk Publications We have a library of publications detailing energy saving techniques for a range of sectors and technologies. www.carbontrust.co.uk/publications Case Studies Our case studies show that it s often easier and less expensive than you might think to bring about real change. www.carbontrust.co.uk/casestudies Carbon Trust Advisory Delivers strategic and operational advice on sustainable business value to large organisations. www.carbontrust.co.uk/advisory Carbon Trust Certification Delivers certification and verification services to companies and runs the Carbon Trust Standard and Carbon Reduction Label. www.carbontrust.co.uk/certification Carbon Trust Implementation Delivers services to business in support of implementation of energy efficient equipment and energy efficiency financing. www.carbontrust.co.uk/implementation

CTG076 The Carbon Trust is a not-for-profit company with the mission to accelerate the move to a low carbon economy. We provide specialist support to business and the public sector to help cut carbon emissions, save energy and commercialise low carbon technologies. By stimulating low carbon action we contribute to key UK goals of lower carbon emissions, the development of low carbon businesses, increased energy security and associated jobs. We help to cut carbon emissions now by: providing specialist advice and finance to help organisations cut carbon setting standards for carbon reduction. We reduce potential future carbon emissions by: opening markets for low carbon technologies leading industry collaborations to commercialise technologies investing in early-stage low carbon companies. www.carbontrust.co.uk The Carbon Trust receives funding from Government, including the Department of Energy and Climate Change, the Scottish Government, the Welsh Government and Invest Northern Ireland. Whilst reasonable steps have been taken to ensure that the information contained within this publication is correct, the authors, the Carbon Trust, its agents, contractors and sub-contractors give no warranty and make no representation as to its accuracy and accept no liability for any errors or omissions. All trademarks, service marks and logos in this publication, and copyright in it, are the property of the Carbon Trust (or its licensors). Nothing in this publication shall be construed as granting any licence or right to use or reproduce any of the trademarks, services marks, logos, copyright or any proprietary information in any way without the Carbon Trust s prior written permission. The Carbon Trust enforces infringements of its intellectual property rights to the full extent permitted by law. The Carbon Trust is a company limited by guarantee and registered in England and Wales under company number 4190230 with its registered office at 4th Floor Dorset House, Stamford Street, London SE1 9PY. Published in the UK: March 2012. The Carbon Trust 2012. All rights reserved. CTG076.