Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Similar documents
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

For installation guide see reverse of book

Baxi Combi 80e & 105e

User's Instructions. Alpha HE CB25/33 and HE SY25

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Combi Eco Elite Range. User s Guide and Important Warranty Information

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

Combi 24 HE. User s Guide and Important Warranty Information

Combi 30 HE. User s Guide and Important Warranty Information

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Promax System Condensing System Boiler

User Guide. Main Heat Condensing Central Heating Boiler

Response: The combi boiler. Response: The fit anywhere combi

Drayton Digistat +2RF/+3RF

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Operating instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

BoilerMate SP. benchmark. user instructions A - C L A S S

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

User Guide. Titanium Combi Condensing Combination Boiler

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Operating instructions

INSTALLATION & TECHNICAL MANUAL

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Operating instructions

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Portable Air Conditioner

Instructions for Use Installation and Servicing. To be left with the user

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

GREENSTAR HEATSLAVE 12/18, 18/25, 25/32

Luna 3 Comfort Troubleshooting Guide June 2008

Instruction manual for Firstline FCS12000CH

CARING FOR YOUR WATER HEATER

Please read and keep these instructions. Run water through your machine before first use

Vaillant s plain English guide to. simple, concise and precise

High Efficiency Boiler Range Technical Guide

2-SLICE COOL TOUCH TOASTER

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Owner s Guide and Installation Instructions

Continuous Flow Water Heaters

Aerona Air Source Heat Pumps

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

User manual and Installation instructions

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Installation Guide for Hive Active Heating

ferroli Boiler Replacement Optimax HE- Modena HE

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Electric Flow Boiler

SWIMMING POOL HEAT PUMP Owners Manual

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

User Manual THR840DUK Digital Thermostat

Betacom. 24c G.C. No c G.C. No Installation and Servicing. High Efficiency Condensing Combination Boilers

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

A Class Air Source Heat Pump User Guide

Operations Manual Blast Chiller

OPERATING INSTRUCTIONS

Operating Instructions Split System Air Conditioner

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Look after your boiler so it can look after you


prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

INFRARED QUARTZ WALL HEATER

GREENSTAR 24i Junior/28i Junior

Link-Up. Solid Fuel Association Guide to Central Heating.

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

/2010 US/CA

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Wireless 7 Day Programmable Room Thermostat

User manual. Atec. 086L0130 Rev. 1 EN

Homeowner Quick Start Guide. Version 2

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Getting the best from your urn

Alpha CD13R,18R and 24R

Description of functions

Instructions for Use Installation and Servicing. To be left with the user

User manual. 086U6297 Rev. 9 EN

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

HomeServices Terms and Conditions

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Transcription:

Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r

WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking, blowlamps, hot air guns etc. Do not operate electrical lights or switches either on or off. Open all doors and windows, ventilate the area. SHEET METAL PARTS This boiler contains metal parts (components) and care should be taken when handling and cleaning, with particular regard to edges. SEALED COMPONENTS Under no circumstances must the User interfere with or adjust sealed parts. Customer service call: 01773 828100 Technical helpline: 01773 828300 General and Sales enquiries Tel: 01773 824639 Fax: 01773 820569 Glow-worm is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, effi ciency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk 2

Ultracom 24cxi G.C. No. 47-019-01 13206 Ultracom 30cxi G.C. No. 47-019-02 Ultracom 38cxi G.C. No. 47-019-03 3

Contents Page Important Information 5 Boiler Design and Clearances 6 Boiler Safety Devices 7 Servicing, Maintenance and Spare Parts 8 User Control Panel 9 Lighting the Boiler 10 Adjusting Temperature 11 Setting the 24 hour Clock 12 Setting the Programmer 13 Advancing the Programmer 14 Fault Finding 15 These instructions are an integral part of the boiler and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be left with the user. Please ensure that the installer has fully completed the Benchmark Checklist in the centre pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. Please read these instructions and follow them carefully for the safe and economical use of your boiler. 4

Important Information Gas Safety (Installation and Use) Regulations In your own interests and that of safety, it is the Law that ALL gas appliances have been installed by a competent person approved at the time by the Health and Safety Executive, in accordance with the current issue of these regulations. Gas Category This boiler is for use only on G20 natural gas but can be converted for use on G31 propane. Electrical Connection The boiler MUST be earthed. The boiler MUST be connected to a permanent 230V ac, 50Hz supply, fused at 3A. Connection of the whole electrical system of the boiler, including any heating controls, to the electrical supply must be through one common isolator. The colours of three core flexible cable are, blue - neutral, brown - live, green and yellow - earth. Testing and Certification This boiler is certificated to the current issue of EN 483 for performance and safety. It is important that no alteration is made to the boiler unless approved, in writing, by Glow-worm. Any alteration not approved by Glow-worm, could invalidate the certification, boiler warranty and may also infringe the current issue of the statutory requirements. CE Mark This boiler meets the requirements of Statutory Instrument, No. 3083 of the Boiler (Efficiency) Regulations, and therefore is deemed to meet the requirements of Directive 92/42/EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous fuels. Type test for purposes of Regulation 5 certified by: Notified body 0087. Product/production certified by: Notified body 0086. The CE mark on this appliance shows compliance with: 1. Directive 90/396/EEC on the approximation of the laws of the Member States relating to appliances burning gaseous fuels. 2. Directive 73/23/EEC on the harmonisation of the Laws of the Member States relating to electrical equipment designed for use within certain voltage limits. 3. Directive 89/336/EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility. 5

Boiler Design and Clearances Description The Ultracom cxi range of boilers are designed for use as part of a sealed water central heating system with fully pumped circulation. The pump, expansion vessel and associated safety devices are all fitted within the boiler. The domestic hot water is delivered without the need for storage. The intelligent control system is designed for both simple operation and maximum control. Once the controls are set the boiler operates automatically. 13208 Pluming from flue terminal Like all condensing boilers it will produce a plume of condensation from the flue terminal in cool weather. This is due to the high efficiency and hence low flue gas temperature of the boiler. It is normal and not a fault indication. Compartment or Cupboard Installations Ventilation is not required for compartment or cupboard installations. Do not use the compartment or cupboard for storage. Diagram 1 6

Boiler Safety Devices Boiler Shutdown The boiler software is designed to recognise the potential for an overheat lockout and will shutdown before this happens. To restart the boiler, press the reset button, see diagram 2. If the boiler fails to resume normal operation and all external controls are calling for heat, then call your Installation/Servicing company or Glow-worm service. Frost Protection With the gas and electric supplies ON and irrespective of any room thermostat setting, the integral frost protection device will operate the pump when the temperature of the boiler water falls below 8 O C. The pump will stop after 10 minutes if the temperature is higher than 10 O C or has already reached 35 O C. The burner will only activate if the boiler temperature does not reach 10 O C after 30 minutes or at any time if the temperature drops to 5 O C. The burner will switch off when the temperature reaches 35 O C. NOTE: Any other exposed areas of the system should be protected by a separate frost thermostat. Condensate Drain Blockage As a safety feature the boiler will stop working if the condensate drain becomes blocked. During freezing conditions this may be due to the forming of ice in the condense drain external to the house. Release an ice blockage by the use of warm cloths on the pipe. The boiler should then restart. Contact your Installation/ Servicing company or Glow-worm service if the fault persists. Safety Discharge Valve The safety discharge valve and discharge pipe is fitted to the boiler. If there is any discharge from the pipe, switch off the boiler electrical supply, then call your Installation/Servicing company or Glow-worm service. 7

Servicing, Maintenance and Spare Parts General Note Servicing/maintenance should be carried out by a competent person approved at the time by the Health and Safety Executive, in accordance with the rules in force in the countries of destination. If this boiler is installed in a rented property in the UK there is a duty of care imposed on the owner of the property by the current issue of the Gas Safety (Installation and Use) Regulations, Section 35. Servicing This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack. To ensure the continued efficient and safe operation of the boiler it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the site conditions and usage, but in general, once a year should be enough. To obtain service, please call your installer or Glow-worm s own service organisation using the telephone number on the inside front cover of this booklet. Cleaning The boiler casing can be cleaned using a mild liquid detergent with a damp cloth, then a dry cloth to polish. Do not use any form of abrasive or solvent cleaner as you may damage the paintwork. Frost Protection If the mains electricity and gas services are to be turned off for any long periods during severe weather, it is recommended that the whole system, including the boiler, should be drained to avoid the risk of freezing. Sealed Water Systems The draining, refilling and pressurising MUST be carried out by a competent person approved at the time by the Health and Safety Executive, contact your Installation/Servicing company or Glow-worm Service. Spare Parts REMEMBER, When replacing a part on this boiler, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Glow-worm. If replacement parts are required contact Glow-worm s own service organisation using the telephone number on the inside front cover of this booklet. Please quote the name and model of the boiler. The name and model badge is on the front case. If in doubt seek advice from the local gas company or Glowworm s own service organisation using the telephone number on the inside front cover of this booklet. 8

User Control Panel General Description The User Control panel consists of three toggle buttons, a reset button and display, which will indicate with symbols the status of the boiler, refer to diagram 2. MODE PROG Ext 13176 TOGGLE BUTTON MODE and PROG LCD DISPLAY RESET BUTTON DHW CH TEMPERATURE ADJUSTMENT SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS Central Heating Function Eco Will be displayed when domestic hot water temperature is less than 50 o C Domestic Hot Water Function Ext Glow-worm control (Optional) Central Heating Timed Mode Min burner display Appliance OFF Temperature Max burner display System Pressure Programmer Adjustment Mode Control Panel Outdoor sensor (if fitted) Diagram 2 9

Lighting the Boiler Initial Lighting Remove the cover plate, refer to the fault finding section on page 15 and diagram 8. Check that all isolating valves and the gas service cock on the appliance are open and that water flows from the hot water taps, then close taps, refer diagram 3. Note: If you are in any doubt about the boiler being filled with water contact your installer or Glow-worm's own service organisation using the telephone number on the inside front cover of this booklet. Do not operate the boiler without water. 1. With no demand from any external controls, switch on the electrical supply to the boiler. 13469 Note: If the electrical supply has been interrupted for any reason, you may need to set the clock and day before continuing, refer to diagram 5. 2. Select your required function, refer to diagram 2, press "Mode" repeatedly to scroll through your options and select one of the following:- Timed central heating with domestic hot water. Constant central heating with domestic hot water. Domestic hot water only. Boiler functions ALL switched off. A - Central Heating Isolation Valve B - Domestic Hot Water C - Gas Service Cock D - Domestic Cold Water E - Condensate drain F - Double Check Inlet Valve G - Safety Discharge Valve Diagram 3 3. Turn ON your external controls and select the room temperature required. The boiler will operate automatically. Note: The display will indicate the Heating system pressure in bar or: Water temperature, when heating is on. Domestic Hot Water temperature setpoint, when there is a demand. Fault Code (see section Fault Finding) 10

Adjusting Temperature Domestic Hot Water Domestic hot water has priority over central heating. The temperature is factory preset to the minimum 40 O C, but can be adjusted to a maximum of 62 O C as required, refer to diagram 4. Economy Setting The "ECO" setting of 50 O C is recommended and ideally suited to normal family use. Central Heating The temperature is factory preset to the minimum 38 O C, but can be adjusted to a maximum of 82 O C as required, refer to diagram 4. Domestic Hot Water STEP 1 Press the "+ or -" once the current temperature will be displayed "flashing". Eco OFF Central Heating Press the "+ or -" once the current temperature will be displayed "flashing". Eco OFF STEP 1 13179 STEP 2 STEP 2 Press "+ or -" to increase or decrease the temperature. The temperature setting will automatically save after 5 seconds. Press "+ or -" to increase or decrease the temperature. The temperature setting will automatically save after 5 seconds. 13178 Diagram 4 11

Setting the 24 hour Clock To set the clock, refer to diagram 5. STEP 1 MODE 13177 PROG Press and hold "PROG" 5 secs. the "hours" symbol will flash. STEP 2 Press the "+" or the "-" to set the hour. STEP 3 MODE PROG Press "PROG" to confirm. The process will automatically scroll to minutes, then days, set as previously described. Diagram 5 12

Setting the Programmer Timed Central Heating Domestic Hot Water Factory preset timed intervals are:- Factory preset times for preheat are:- Monday - Friday - ON 6.00 - OFF 8.00 ON 16.00 - OFF 23.00 Monday to Sunday - ON 6.00 - OFF 24.00 Saturday - Sunday - ON 8.00 - OFF 23.00 To alter the times to suit your requirments, follow "Steps" 1 to 4 STEP 1 STEP 2 Press "PROG" button once to Press + or - to move the flashing view the factory default cursor to the desired time. central heating running times. STEP 3 Press "+" to add a time segment or "-" to remove a time segment. 13468 MODE PROG Flashing cursor. STEP 4 Press "PROG" to validate the time intervals. The display returns back to display the current boiler status however if the 7 day function is enabled the display will move to the next day. "Running Time" Indicated by solid squares. Square represents 30 minutes. Diagram 6 13

Advancing the Programmer Advancing the timed central heating programmer ON /OFF times This function will only work when the appliance is in timed operating mode, "Clock symbol". Refer to diagram 2. The activated/deactivated segments will flash for 5 seconds. Press + and hold for 5 seconds your appliance will operate until the next OFF period, or you can cancel by pressing + for 5 seconds. 13181 Diagram 7 14

Fault Finding Appliance fails to light The LCD will display a flashing 'F' and code number, press the reset button on the control panel, see diagram 2. If the display shows a flashing pressure of 0.4bar or less, then you will need to pressurise the system as described below. If any fault persists, contact your installer/service provider or Glow-worm Service, using the telephone number on the inside front cover of this booklet. Filling Central Heating System Remove the cover plate, see diagram 8. 1. Ensure that the filling loop flexible hose is securely connected to the double check inlet valve, see diagram 9. 2. Fully open tap "A", then gradually open tap "B" to fill the heating system to a pressure of 1.0bar. When completed close the filling taps. 3. IMPORTANT: To comply with the water regulations the flexible hose must be disconnected from the double check inlet valve - undo the nut and pull the flexible hose from the valve. Electrical Supply Failure The boiler will not work without an electrical supply and normal operation of the boiler should resume when the electrical supply is restored. If the boiler does not resume normal operation, check the external controls, it may be necessary, to "reset" the boiler, refer to the section, "Boiler Safety Devices". 13539 VALVES SHOWN CLOSED 13470 Diagram 8 Double Check Inlet Valve Diagram 9 15

Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions. Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT www.high-efficiency.info 0020020822-03 05.09