Ecofys VII U-Values for Better Energy Performance of Buildings



Similar documents
SELECTIVE GLAZING FOR SUN CONTROL

ZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS. UK Building Regulations and EU Directives

Clean Energy Solutions Center IEA Technology Roadmap: Energy Efficient Building Envelopes Launch

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Smart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

Improving thermal insulation of concrete sandwich panel buildings

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Isover Multi-Comfort-House Comfort and Energy Efficiency in Buildings

Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Energy audit in Finland

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

Norwegian Tax Authority - Oslo Norway

Passive houses in Sweden

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Energy efficiency and excess winter deaths: Comparing the UK and Sweden

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Cost optimal building performance requirements

ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING

Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Where to start: Energy efficiency potential in buildings

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

Innovative Energy Technologies Where do we stand?

Adaptive strategies for office spaces in the UK climate

Energy [R]evolution vs. IEA World Energy Outlook scenario

Case study on residential building renovation and its impact on the energy use and thermal comfort

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING

Small-Scale Solar Heating and Cooling Systems

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Passive Solar Design and Concepts

Module 2.2. Heat transfer mechanisms

Passive & Active Design

BER Assessors Dwellings Technical Bulletin

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

Promotion of energy efficiency and renewable energy experiences from Norway

Towards low energy buildings the development of building regulations in Norway. Clara Good, Norut Narvik Oulu, 27 May 2011

The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Energy Efficiency HOSPITALITY.

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

Hybrid heat pumps. saving energy and reducing carbon emissions

Status and Priorities of Building Energy Efficiency in China Xudong Yang, Ph.D.

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Roadmap for moving to a competitive low carbon economy in 2050

HEAT TRANSFER ANALYSIS OF COLD STORAGE

Twinning «Improvement of the Energy Efficiency in Turkey»

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Federation of European Heating, Ventilation and Air-conditioning Associations

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Building Energy Labels: The Swiss MINERGIE Label

Fläkt Woods Building Future

Where to start: Understanding building energy use

Energy efficiency building standards in Japan

Enterprise-wide approaches to power sector energy efficiency improvements

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

THERMAL LOSSES Thermal Losses Calculations

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Implementation of the EPBD in Cyprus. Status in November > Introduction. 2 > Certification. Cyprus

Gas: the right choice for heating in Europe

Energy savings in the residential area are essential in

Energy Savings with Window Retrofits

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

TOWARDS NEARLY ZERO ENERGY BUILDINGS IN IRELAND PLANNING FOR 2020 AND BEYOND. Department of the Environment, Community and Local Government

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

The German experience on energy savings in buildings: Overview on strategy, policies and policy frameworks

Energy Efficient HVAC-system and Building Design

Residential & Commercial Sectors Overview CLIMATE

EN Insulating glass units, intended to be used in buildings and construction works

Germany's path towards a nearly climate-neutral residential building stock 2050: Comparison of greenhouse gas mitigation strategies

Case Study Family Room Renovation 3br family home, Melbourne

Strategies for an Environment Friendly Low Energy Retrofitting of a Health Care Facility in the Hot Climate of UAE

Energy Efficiency. Bars & RestauRants.

Protocol for the Certification of Energy Simulation Software: First edition, December 2009

Selecting Energy Efficient Replacement Windows in Nevada

Transcription:

Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario

Key figures from Ecofys studies 40% Energy 270 billions/y 3.3 millions barrels/d 460 millions tons CO 2 /y 530.000 jobs (based on Eurima estimate) Energy price ref: 70$/barrel Trias Energetica "the most sustainable energy is saved energy" 1st: minimise energy loss 2nd: use renewable energy sources 3rd: efficient use of fossil energy sources 1 /

Objectives of the study TO DEFINE the optimum U-values base on economic criteria, and environmental criteria, for all countries in Europe. TO INVESTIGATE whether there is room for improvement in reconsidering national requirements (U-values) for building components. TO IDENTIFY the impact of insulation on cooling energy demand in hot climate regions. Starting point EPBD Energy Performance of Buildings Directive EPBD whole building energy performance National or regional whole building requirements Energy performance requirement per building component in practice + U-values either as design criteria or component requirement Economic optimum Environmental goals

U-value - coefficient of heat transmission Watt/m 2.K low U-value = low energy transfer Climate conditions CDD, or outdoor t.d > 18.3 C HDD, or outdoor t.d < 15 C

U-value - coefficient of heat transmission Insulation & cooling demand in Seville ENERGY DEMAND FOR COOLING - SEVILLE SFH; standard package: wall 0,6 / roof 0,5 / floor 0,5 Wm 2 K 60 kwh/m 2 a 40 20 0 reference no shading high int.gains no night vent. low thermal mass without insulation 31 41 36 36 51 with insulation 17 30 22 22 18

U-values - economic optimum Economical parameters: Energy mix Energy price scenario WEO 2006 Peak Price (oil: $70 / barrel) Investment costs & Interest rate Today: > $98 Energy performance of existing buildings stock Residential buildings: Single & Multi Family House Climatic conditions for 100 cities characterized by HDD and CDD Life cycle costing over a period of 30 years U-values - climate change To limit temperature increase below 2 C vs. pre-industrialized time, the IPCC reports tell us that global GHG emissions should decrease by 50% by 2050, compared to 1990 In this perspective, EU commitment is to reduce GHG emissions by 60% to 80% in 2050 compared to 1990 Buildings, the highest energy consumer the most cost effective CO 2 mitigation measure (Mc Kinsey), with technical solutions available, should contribute above average. It has been assumed that building contribution should be a reduction of 85% of GHG emissions by 2050 compared to 1990

Savings from heating and cooling for one element of the construction Costs + Insulation thickness* Energy cost cooling + heating = Costs - A negative cost represents a SAVING *Indication of the thermal performance of the element. Linear investment for one element of the construction Costs + Investment costs Insulation thickness Total costs cooling heating Costs - A negative cost represents a SAVING Energy cost

From cost optimum to U-values EXISTING HOUSING STOCK Costs + Present NEW BUILDING REQUIRE- MENTS More comfort More sustainable U-value? Minimum BEST PRACTICE* STATE of the ART Example 1,00 0,70 0,55 0,40 0,30 0,20 0,15 0,12 *Based on oil price study hypothesis Whole building approach & Passive House Costs + economic optimum roof insulation wall insulation Total energy related investment costs extra for triple glazing/ventilation floor insulation avoidance heating system BEST PRACTICE Costs - Energy savings Passive House optimum 5 /

Boundaries of the study Costs + Total energy related investment costs economic optimum BEST PRACTICE* extra for triple glazing roof insulation wall insulation Passive House floor insulation concept is not yet avoidance heating system considered in the study Costs - ECOFYS VII Energy savings Passive House optimum *Based on oil price study hypothesis Recommended U-values - Roof Peak price - roof 0,80 0,75 0,70 U-value [W/m2K] 0,65 0,60 0,55 0,50 0,45 0,40 0,35 0,30 0,25 recommended U-value for roof exist.required. U-value -low for roof exist.required. U-value -high for roof 0,20 0,15 0,10 0,05 0,00 0 1000 2000 3000 4000 5000 6000 7000 8000 HDD 10 /

How blue are U? Present U-values U-values based on WEO2006 price < 0,14 W/m²K >0,59 W/m²K U-values based on peak-price U-values comparison 0,6 U values STOCKHOLM WEO 2006 Peak price Post Kyoto Buildings reg U values AMSTERDAM WEO 2006 Peak price Post Kyoto Buildings reg 0,5 0,6 0,4 0,5 0,3 0,4 0,3 0,2 0,2 0,1 0,1 0 Wall Roof Floor 0 Wall Roof Floor U values WARSAW WEO 2006 Peak price Post Kyoto Buildings reg U values SEVILLA WEO 2006 Peak price Post Kyoto Buildings reg 1,4 0,6 1,2 0,5 1 0,4 0,8 0,3 0,6 0,2 0,4 0,1 0,2 0 Wall Roof Floor 0 Wall Roof Floor

Conclusions (1/2) In 2007, most requirements for U-values for wall, roof and floor in new buildings are far from the economic optimum. This means that cash is being wasted for households as well as for society U-values recommended in the study are valid for new as well as for existing buildings. While regulations for new buildings are changing, not much is happening yet for existing buildings. From cost optimum to U-values EXISTING HOUSING STOCK Costs + Present NEW BUILDING REQUIRE- MENTS More comfort More sustainable U-value? Minimum BEST PRACTICE* STATE of the ART Example 1,00 0,70 0,55 0,40 0,30 0,20 0,15 0,12 *Based on oil price study hypothesis

Conclusions (2/2) Almost identical recommended U-values, whether calculated base in cost effectiveness or post Kyoto target. If we want to meet our environmental objectives by 2050, with milestones in 2020, we better start NOW! Insulation (especially roof and wall) reduces energy demand for cooling of residential buildings, in Southern and Central Europe. Much is to be done in these warm climate regions. THANK YOU!

Avenue Louise 375, Box 4 B-1050 Brussels, Belgium Tel +32 (0)2 626 20 90 www.eurima.org