ModEva 10S ModEva 12S ModEva 15S

Similar documents
MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AXIS 262+ Network Video Recorder

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Datenblatt - Fiche technique - Data sheet

TrueAlarm Fire Alarm Systems

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HP Server Console Switch with Virtual Media Overview

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Datasheet. The cost-optimized all-rounder

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

Recording. Smart recording (depending on the camera models)

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Panel PC SIMATIC HMI IPC577C

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Multi-Range Programmable DC Power Supplies 9115 Series

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

DCS Data and communication server

QuickSpecs. HP IP Console Switches. Overview

Product Information Fire alarm panel 8000 C

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Embedded & Industrial PCs International Products and Configurations INDEX

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Waveguide Access Point WGA631. Product Guide

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

CANtrol EC Modular Control System Powerful and versatile

Rack mounted telephone- and leased line modem for industrial applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Electronic Control Devices The European Product Catalogue 2007

Chapter 5 Cubix XP4 Blade Server

QuickSpecs. Models HP Server Console Switches

Intel Core i processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Multi-Range Programmable DC Power Supplies 9115 Series

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

DCS data and communication server

Waveform Monitor Audio & Loudness Logging

Model: DC-A2IO Advanced HVAC Controller

User manual Compact Web PLC WP240 series IEC-line

IOVU-571N ARM-based Panel PC

Connect up to a total of 8 cameras from GV IP cameras (excluding GV Fisheye cameras) and third party IP cameras (of 640x 480

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Permissible ambient temperature Operation Storage, transport

Job Aid Pre-Installation Information S8500 Media Server

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

DVI KVM Switches DP-MUX 7.4

How To Use An Fujitsu Zero Client Dz19-2 (Dz19) For A Long Time

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

HP Backup and Recovery Manager

Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Rack Mount LCD KVM Assembly Installer/User Guide

2100 POS System User Guide

ivms-4500 HD (ios) Mobile Client Software User Manual (V3.4)

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

MANUAL PC1000R

UniOP epad33 and epad33t

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

QuickSpecs. HP Compaq t5525 Thin Client. Overview

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

1.44 kw Programmable DC Power Supplies XLN Series

v1 System Requirements 7/11/07

Rugged and open to your applications

Series: IDAM Servo Drive E Digital Motor Drive - DMD

DMS-10101, Computer Equipment

Data Sheet FUJITSU Display L27T-1 LED Display

High Power Programmable DC Power Supplies PVS Series

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Multifunction devices

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

SCD Server. SCD Server Pro

Fax Server. Blue Line IP ISDN ISDN PRI

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

IntesisBox KNX Modbus TCP master

Smart relays Zelio Logic Step into an intuitive world!

Technical Information POWER PLANT CONTROLLER

Cisco MCS 7825-H2 Unified CallManager Appliance

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Designed for the needs of automation, telecommunications, remote supervision, and monitoring

Display units With alphanumeric screen

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Product Description Sheet RB15 200D Gantry Robot Item No

MultiViu Flex 7 Data Sheet

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Fax Server. Fax Server PRI. Blue Line. Fax Server for ISDN30 line bundles

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Operator Control and Monitoring Devices

NGSS Data Consolidator (DC)

Transcription:

ModEva ModEva is a range of numerical control units intended specifically for sheet metal working. According to the software installed, it will be used on synchronised or unsynchronised press-brakes of the up-stroking or down-stroking type. ModEva numerical control units can control up to 18 axes of which 2 are synchronised hydraulic axes especially intended for press-brakes. The numerical control is composed of 2 main elements: - the programming console - the CNC (Computerised Numerical Control). The programming console is located within the operator's reach, generally fixed to a swivelling arm; the CNC is placed inside the electric cabinet. The CNC is available in 2 rack formats. - The rack version C This is a small, very compact rack, convenient for many situations. - The rack version M This is a bigger rack permitting a varied combination of configurations. The software enables manufacturers to configure the axes, the inputs/outputs and the auxiliary functions according to their needs. ModEva 10S ModEva 12S ModEva 15S Versions PS PC P PP ModEva CNC /C ModEva CNC /M Version for synchronised press-brakes. Like the PS but for press-brakes with mechanical (or hydraulic) stops and beam control with a linear measuring rule. Like the PC but without beam control with a linear measuring rule. Version for folding presses. ModEva CNC version "C" (Compact): can control up to 4/6 axes or even 18 with CAN axes*. ModEva CNC version "M" (Maxi): controls up to 12/14 axes or even 18 with CAN axes*. * see definitions of the axes and configurations further on in the document. CDS_modeva_en.doc C-PUB-CDSMOD-EN V1.5d 1/6 05.03.2007

ModEva range or or CNC/C CNC/C ModEva 10S ModEva 12S ModEva 15S 10" screen 12" screen 15" screen 2D 3D Windows ModEva is a modular range with a choice of: 3 programming consoles with 3 screen sizes 2 programs and 1 operational system Windows. 2 different rack sizes depending on the number of axes and the desired technology (analogue or CAN). Definitions: Hydraulic axes: Analogical axes: CAN axes: NMX: NSX: NCX: An analogue axis especially intended for controlling the beams (Y1-Y2). These two axes are on the NPU (formerly on the NAX). Axes whose position is given by an incremental sensor and whose instructions are provided by the CNC via an ±10V DC analogue voltage. One also refers to an analogue interface axis. These axes are controlled by cards called NMX / NSX. Each of these cards controls 2 axes. Axes whose positioning information is handled through a CAN bus. These axes require an NCX card on the CNC side and a CAN interface on the servo-amplifier side. An NCX card can control up to 8 axes. The number of CAN axes is controlled as an option. The ModEva CNC can be equipped with a maximum of 2 NCX axis cards. A master card for 2 analogue axes. A master card controls up to 3 NSX slave cards. A slave card for 2 analogue axes. A slave card in all cases requires an NMX card. CAN card for a maximum of 8 CAN axes. This card can handle various protocols according to the type of servo-amplifier utilised. It is possible to combine CAN and analogue axes. Configurations of CNC axes Rack version CNC / C CNC / M No. of axis cards 2 5 Axis position (slot No) 0 1 0 1 2 3 4 5 The most common configurations NMX - NMX NSX NSX NMX NSX NMX NSX NSX NSX NMX NLR NMX NSX NSX NLR NCX - NMX NSX NSX NLR NMX NCX NLR NCX NLR NMX NSX CDS_modeva_en.doc V1.5d 2/6

Configuration of the consoles Console ModEva 10S ModEva 12S ModEva 15S TFT screen 10" 12" 15" Resolution 640x480 800x600 1024x768 Track Sensor - Yes Yes Touch Screen - - Option Quick Cursor Yes 3.5" floppy Yes Ext. keyboard socket Yes PS2 Ext. mouse socket Yes Serial mouse with mini DIN socket Power Through the Panel Link Auxiliary I/O 12/12 Seal IP 54 Link CNC 2 cables RJ 45 twisted pair category 6. Cables 5 m or 10 m. Dist. > 10 m with CYBELEC repeater, ModEva 15S > 5 m with repeater Temperature, pollution level, Min. 5 Celsius, max. 40 Celsius.* Pollution level 2. relative humidity, Relative humidity (10 to 85% non condensing). during work. * If the ambient temperature approaches or exceeds 40 Celsius, it would be advisable to install special ventilation, or even air-conditioning. Weight Approx. 10 kg Approx. 5 kg. Configuration of the CNCs Type ModEva CNC/x-xx-Px-2DW ModEva CNC/x-xx-Px-3DW Software 2D 3D System Windows XP embedded XP pro optional** CPU Kontron 400 MHz 800 MHz optional** RAM 256 MB 512 MB optional** Disk 1 GB flash** Network Yes Ethernet RJ45 USB 1.1 Yes Printer port Yes Keyboard input Yes PS2 Mouse input Yes PS2 Screen output Yes STD VGA Y1, Y2 NPU card RS 232 port Yes 2 of which 1 configurable to RS 422 Serial port for PLC Yes 1 RS232 configurable to RS 422 Analogue axes NMX cards, NSX, according to configuration and rack version CAN axes NCX cards according to configuration and rack version Sensor inputs 5V DC Line Driver, obligatory complementary signals, Digital inputs NIN cards 32 24 VDC inputs opto-coupled Digital outputs NOT cards 32 outputs 24 VDC "sources", max 2.5 A / output (NOT 204) Max 6 A / card Analogue inputs NIN cards 6 analogue inputs According to configuration 0-10, 0-24 VDC A/D 8 bits Analogue outputs Axes and FA Rack version C or M Number of axes 02 to 18 Type of machine, PS, PC, P, PP NOT cards 4 outputs 0-10 VDC (8 bits) for the auxiliary functions Z out output impedance < 100 Ω, Zl load 10 kω Power supply 24 VDC / max 4A ± 15% Seal Must be installed in an approved electric cabinet. Temperature, pollution level, relative humidity during work. Min. 5 Celsius, max. 40 Celsius.* Pollution level 2. Relative humidity (10 to 85% non condensing). * If the ambient temperature approaches or exceeds 40 Celsius, it would be advisable to install special ventilation, or even air-conditioning. Weight Rack version C: approx. 5 kg. Rack version M: approx. 6 kg. According to equipment. ** Data may be modified without notice for the proper operation of the numeric control. Other configurations on request. CDS_modeva_en.doc V1.5d 3/6

Auxiliary axes and functions of the standard software The elements listed below are available and can be configured in all numerical controls supplied with standard software (within the number of available axes). Y1 - Y2 Synchronised axes for the beam (servo-valves, proportional valves). X, X1, X2, X5, X6 Main rear backgauge axes (X5, X6 generally for gauges external to the frame). X1 ABS, X2 REL Secondary gauge axes in absolute or relative mode. R, R2, R5, R6 Backgauge height-adjustment axes (R5, R6 generally for gauges external to the frame). Z, Z2, Z5, Z6 Axes for left/right movement of the backgauge. M1, M2 Axes for the adjustment / movement of the die. Conical folds Free 1, 2, 3, 4 Pressure Crowning F1 to F10 Languages Angle measurement Comfortable programming for conical folds (requires X, X2 and adapted stop fingers). Independent axes without any particular control. Voltage output for pressure valve control. Should current control be wanted, the MVP 100 accessory, which is an external amplifier module to be fitted in the electric cabinet, would be necessary (see the MVP 100 data sheet). Voltage output for adjusting the hydraulic crowning. Should current control be wanted, the MVP 100 accessory, which is an external amplifier module to be fitted in the electric cabinet, would be necessary (see the MVP 100 data sheet). or 24 VDC (SP, SN) outputs and potentiometric position transducer for adjusting the mechanical crowning (Wila type). Configurable auxiliary functions (possibly, the number of AFs may be limited according to the type of function and management). 24VDC voltage or logical order outputs, with or without position control by means of a potentiometric transducer. Special controls for gauge fingers, bending aids, die movements. French, German, English, Italian, Spanish, Portuguese, Swedish, Danish, Finnish, Dutch, Hungarian, Polish, Czech, Slovene, Russian, Turkish, Chinese, Taiwanese. Other languages on request. Automatic correction by means of the angle measurement in serial link with digital angle protractor Mitutoyo or other compatible systems. Optional auxiliary axes and functions and other options (at extra cost) M1 M2 mounting Axes for the adjustment / movement of the die in relation with the choice of tool mounting. X3, X4, X7, X8 Front gauge axes (not calculated). Z3, Z4, Z7, Z8 Front gauge axes (not calculated). H, H2 Rear sheet support axes (not calculated). H3, H4 Calculated front sheet support axes. AP1 AP4 CAN axes Angle measurement Thickness measurement Axis thickness measurement Calculated front / rear folding assistance axes. The number of CAN axes is optionally controlled. Option permitting the adaptation of an angle-measuring system during the folding. Option permitting the automatic correction of the depth calculation by using external sheet-metal thickness measuring equipment connected by RS 232. Option permitting the automatic correction of the depth calculation by using external thickness measuring equipment connected to an axis card. The measurement is taken using conventional encoders. Message interpreter Option for the complete remote control of the CNC via network or RS 232. Reading/writing of variables, corrections, part loading, mode changing, etc. Ideal for automation and/or applications with robot. Possibility of connecting the results of an external program. Other There exist numerous options specific to each constructor. Other options can be developed according to needs. CDS_modeva_en.doc V1.5d 4/6

Hardware options Touch Screen Touch panel for ModEva 15S. USB CD reader Hand-grips External USB CD reader, self-powered by the USB card (for Windows models). For ModEva 15S console, choice of 2 models. Auxiliary panels Auxiliary panels for Lazer Safe commands, virgin or customised auxiliary panels for ModEva 10 / 12 or 15S Fixing adapter Sserie Earthing kit CAH / CAB MVP 100 MSV Adaptation plate for the ModEva 10S and 12S, allowing the installation of a ModEva 10S or 12S on a pendant arm of ModEva 10 or 12 or DNC 1200. Rail and bridles for earthing the sheathing for the ModEva CNC rack. See photo below. Interface card for proportional Hörbiger, Bosch valves. Voltage / current conversion module (0-10V 0,25-0,5 / 0-2 A) for pressure and crowning valves, to be fitted in the electric cabinet. Voltage / current conversion module (0-10V 0-50 ma, 0-300 ma) for servo-valves. 5-24 interface 5VDC 24VDC interface for remote I/O programming console ports. This interface connects to the ModEva CNC CPU. On demand. EC Directives Directives Our numerical control units comply with Directives 89/336/EEC and 73/23/EEC Overall dimensions CNC / C CNC / M Earthing kit CDS_modeva_en.doc V1.5d 5/6

ModEva 10S and ModEva 12S ModEva 15S Auxiliary panel for ModEva 15S Modification rights reserved CDS_modeva_en.doc V1.5d 6/6