User Manual. Before installation and use, please read the user manual carefully.



Similar documents
P10 - Standalone Access Controller and Reader

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AR-721U/721K/661U User s Guide

Digital Keypad Use s Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

Business/Home GSM Alarm System. Installation and User Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

VARIO PROX CARD READER INSTALLATION MANUAL

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

GV-AS/EV Controller. User s Manual

GV- RK1352 Card Reader

Intelligent GSM Auto-Dial Alarm System

GV-AS Controller. Installation Guide

Automatic Telephone Dialer TD-101(W)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Business/ Home GSM Alarm System

MOBILE CALL GSM Alarm System User s Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Adaptability to Enhanced Security

Users Manual of GSM Home Alarm System with Photo-taken

Adaptability to Enhanced Security

DC-8706K Auto Dial Alarm System

Intelligent GSM Auto-dial Alarm System User s Manual

Home Security Alarm System

COLOR VIDEO DOOR PHONE CDV-71BE/D

INSTALLATION GUIDE. FCC ID NOTICE

STATUS POWER MONITOR ALARM SOS DISARM

GSM Alarm System User Manual

Shunt lock function 3066

How To Program An Autodialer

GSM Home Alarm System User Manual.

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/Home. GSM Alarm system

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Installation manual. Version

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

AUTODIALLER / QUICKDIALLER - SA132

User s Information Guide R1A

MANUAL Remote Programmer XM3

F11 User Manual. Version:1.0 Date:Jul. 2010

GSM HOME SECURITY SYSTEM

LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel

User Manual Color video door phone

Security GSM Alarm System

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

ACCESS CONTROL SYSTEM

1R / 4-BUTTON SERIES

Intruder Alarm System

GSM Door Phone System

Wireless Alarm system s manual

Using your LED Plus keypad

PiSector Home security systems

Iphone & Android App Smart GSM Home Alarm System

Operating Instructions. Keypad

Version:G300 V Business/Home GSM Alarm System. Installation and Users' Guide. ( 99 wireless zones)

Six-defense zone Display Alarm System. User Manual

Auto Dialer. Manual E-921APQ E-921GPQ

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

NESS D Zone Control Panel and Dialler OWNER S MANUAL

PK5500 v1.1 Installation Instructions

How To Control A Car Alarm On A Car With A Remote Control System

Installation Instructions

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

USER MANUAL V5.0 ST100

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

GSM home alarm system s manual

WIRELESS HOME ALARM SYSTEM (WHA1)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

SECURITY SYSTEM ADP-CAN

9452/9453 Installation and User Guide

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

INSTALLATION MANUAL XM3 Reader

PAC1 Door Access Controller

User Guide. Model: MAS-WA-SYS

CipherLab 5100 Time Attendance Utility Manual

HAI Access Control. The HAI Access Control Card Reader can be used for:

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

Wireless Auto-dial Intruder Alarm System

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

Emergency Dialer DIAL-ALERT MODEL: AD

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

MOBILE CALL GSM alarm system

Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using.

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Transcription:

Sebury Technology Co., Ltd. Address: 5/F, Building 8, Xinwu Industrial Park, Xili, Nanshan District, Shenzhen, China. Tel: +86-755-88856 Fax: +86-755-888565 P.C.: 58055 www.sebury.com.cn User Manual Before installation and use, please read the user manual carefully.

Contents. Description, Features and Specifications. Quick Installation Guide. Manager Card Operation. User Settings 5. Alarm 6. To Reset to Factory Default 7. Sound and Light Indication 8. Detailed Programming Guide 9. Advanced Application - Various Working Mode Application 9. Wiegand Reader 9. Standalone for Single Door 9. Automatic Mode 9. Standalone for Two Doors 9.5 With External Reader for Two Doors 9.6 Two Units Interlocked for Two Doors 9.7 Anti-passback for Single Door 9.8 Anti-passback for Two Doors 0. Simple Troubleshooting. Packing List 0 0 5 6 9 0 5 6 7 9

. Description, Features and Specifications. Specifications. Description The stouch-w / skey-w / stouch-s / skey-s include an access host and a i Box, which are connected by Wiegand Bus. The access host permits entry using proximity technology and keypad with PIN, and the i Box provides Power Supply, Lock Driver, Alarm, Ring Bell, Exit Button and Door Contact for the whole system. The access host supports 5KHz EM, HID cards and.56mhz (stouch-w / skey-w) Mifare, CPU cards all in one. It is with relays to control doors and supports up to 000 users in total, each user can possess one card and one PIN. Besides, it also supports Master Code, Manager Cards, Duress Card users and Duress PIN users, providing users with easy operations and safety reliability.. Features Strong pure aluminium alloy case; waterproof, conforms to IP65 Built-in switching power supply for i Box, input AC 00-0V or DC -V Split design of the control part, prevent opening the door by strong magnetic, short circuit, open circuit or other illegal ways Built-in 5KHz and.56mhz card reader (stouch-w / skey-w) Built-in 5KHz card reader (stouch-s / skey-s) Digital backlit key, the back light can be set to Normal ON, Normal OFF or Human-Approach ON Built-in door bell and also support external door bell function Multi working modes: reader, one door, two doors, interlock, anti-passback and so on, suitable for many occasions.. Access Host Input Voltage Idle Current Card Reading Distance Card Frequency Card Transmission Format Keypad Transmission Format Dimension Operating Temperature Operating Humidity.. i Box Input Controller Total Output Power Power Input Voltage Access Host Port Output Current 0 0 i Box DC V-V 5mA 0mm Max 5KHz &.56MHz(sTouch-w / skey-w) 5KHz (stouch-s / skey-s) 6-7 Bit Bit, 8 Bit and Virtual Card Number 5 8.7 mm (s Touch-w / s Key-w) -0 C ~ 60 C 0%~95% AC 00V-0V 6W DC V-V 0.5A 6 97 mm Operating Temperature -0 C ~ 60 C Operating Humidity 0%-95% 58.7 mm (s Touch-s / s Key-s)

. Quick Installation Guide (Before installation and use, please read the Quick Installation Guide carefully) Logo Indicator Light Logo Indicator Light Bracket Touch Keypad Metal Button Keypad Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Photosensitive Tamper Window Sound Hole Safe Screw Hole Access Host Bottom Panel Door Bell Button Door Bell Button Connect Wire Access Host Front Panel Access Host Front Panel Access Host Back Panel 0 0

Sticker Size: 78 X mm Product Bracket Size : 7.8 X 5.9mm Diameter: 6mm(Rubber Bungs) Diameter: mm Diameter: 0mm 60.60 mm Logo Indicator Light Touch Keypad Safe Screw Hole Drill Holes For concrete wall, drill the hole in 6mm diameter Fix the Bracket and Install the Access Host Infrared Receiving Hole Infrared Emission Hole Access Host Bottom Panel Card Swiping Area Door Bell Button Access Host Front Panel Bracket 5.9 mm 8.80 mm Logo Indicator Light Metal Button Keypad Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Photosensitive Tamper Window Sound Hole Connect Wire Door Bell Button Access Host Front Panel Access Host Back Panel Pay attention to the sequence during installation 05 06

7mm Fix Safe Screws Install i Box and Exit Button Diameter: 6mm (Rubber Bungs) Install Lock Wiring AC00V~0V Yellow-Green Diameter: mm Blue N L Brown Short circuit plug for lock Lock (not included in the package, please equip it locally) +V GND D0 D OPEN GND NC +V Diameter: 6mm (Rubber Bungs) Red Black Green White Yellow Yellow Black N00 Red Diameter: mm 55.00 mm Diameter: 7mm Access Host Exit Button Lock Safe Screws Before installing exit button, please read its user manual carefully Remark: > Pay attention to the sequence when wiring, for different types of locks, please refer to their user manual > For the indicator light of exit button, need to connect an extra V power supply 07 08

L N Input AC00-0V External DC Power Red Black Green White Access Host Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire ( Wiring ) Lock (A / B) +V +V LOCK A + + N00 LOCK B N00 NC NO NO NC COM GND COM GND Here are some lock wirings based on different locks: Lock Wiring Connecting COM and GND, then connecting lock to +V and NO (or NC) Lock Type A: Fail Secure Lock (Unlock when power on ), such as Electric Controlling Lock, etc. Lock Type B: Fail Safe Lock (Unlock when power off ), such as EM Lock, Electric Bolt Lock, etc. IN00: Diode, which is mainly used for preventing the harmness on relay from surge high voltage of Lock when relay contact is released. The use life of relay will be shortened and the high voltage pulse will affect other circuit BELL_A BELL_B Door Bell Interface Principle Relay contact in BELL_A & BELL_B will be close for 00mS then release for each bell stroke. +V +V ALARM- Alarm Interface Principle FET (field effect transistor) will be connected when alarm operates, and vise verse. +V +V NO NC COM GND Lock Interface Principle Relay will be picked up once unlocking instruction received, and it will be released when unlocking time is beyond. COM: Relay Contact NC: Normal Close, which is connected with COM normally. NO: Normal Open, which is disconnected with COM normally. N00 Lock A Short-Circuit Wire N00 K+ K- Lock A Short-Circuit Wire 09 0

N00 Short-Circuit Wire Lock B Lock B N00 Short-Circuit Wire. User Settings. To unlock the door by single card only: Read valid card once, the door will open. Precondition: > Set the door entry by card only > Set for opening the door by multi cards. To unlock the door by multi cards: Read -0 pcs valid cards (time interval can not exceed 5s), the door will open. Precondition: > Set the door entry by card only > Set -0 for opening the door by multi cards. To unlock the door for card and PIN users Read valid card Input -6 digits PIN #, the door will open. Manager Card Operation. To add card user by Manager Add Card (only for Zone ) Manager Add Card User Card Manager Add Card Cards can be added continuously. To delete card user by Manager Delete Card (for both Zone and Zone ) Manager Delete Card User Card Manager Delete Card Cards can be deleted continuously. To unlock the door for card or PIN users Read valid card Or Input -6 digits PIN #, the door will open.5 Relay operation Both of the two relays on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines etc) Pulse Mode Every time a valid card/tag read or PIN input in Pulse Mode, the relay will operate, for the pre-set relay pulse time. Toggle Mode Every time a valid card/tag read or PIN input in Toggle Mode, the relay changes state, which will not turn back until read card/tag or input PIN again.

.6 To change the PIN of a PIN user Read card Old PIN # New PIN # Repeat New PIN # Or User ID number Old PIN # New PIN # Repeat New PIN # Remark: st For users without card, must get ID number and initial PIN from the master. For Zone, the digit of PIN must be, st for Zone, the digit of PIN must be For the card users with PIN, must use reading card to change the PIN for the first time..7 Door Bell Press the door bell button on the access host, the buzzer will sound ring-back tone, at the same time, the smart controller's built-in door bell or the external door bell will ring. There are working modes optional: Mode 0 : Door bell function is unavailable. Mode : Access host's ring-back tone is available, i Box's built-in door bell is available, the external door bell is unavailable. Mode : Access host's ring-back tone is available, i Box's built-in door bell is unavailable, the external door bell is available. Mode : Access host's ring-back tone is available, i Box's built-in door bell is available, the external door bell is available. Remark: When the access host's working mode is Automatic Mode (Factory Default Mode), without the smart controller, there will be no ring-back tone. Automatic Mode: In this mode, when the access host connects to i Box, it is standalone for single door; If without smart controller, it work as Wiegand reader automatically. 5. Alarm 5. Anti Tamper Alarm When enable the anti tamper alarm function, if the access host is disassembled illegally, the access host's buzzer and the external alarm will operate. 5. Door Contact Alarm When connect with door contact, if the door is opened illegally, the access host's buzzer and the external alarm will operate. 5. Anti-duress Alarm When read Zone duress card / input 8-digit duress PIN or Zone duress card / input 8 -digit duress PIN, then press #, the corresponding lock will open, at the same time, the external alarm will operate, but the access host buzzer will not operate. 5. To Remove the Alarm Read valid card or input master code can remove the alarm. If there is no operation, the alarm will remove automatically after min. 6. To Reset to Factory Default To reset to factory default, power off, then power on, the logo will turn into orange after s, press * within s, release it until hear two beeps, then will hear one long beep and the logo turn in white, means reset to factory default successfully. Remark: Reset to factory default, the users' information is still retained.

7. Sound and Light Indication 8. Detailed Programming Guide Operation Status Standby Press Key Read Card Door Open Operation Successful Operation Failed PIN Inputting Card & PIN Reading Multi Card Reading Start Menu Sub Menu Under Setting Manager Card Ente r Manager Card Exit Alarm Ring-back Tone Logo Color White Green Green Green Red Red Red Slow Shine in White Red Orange Orange White Quick Shine in Red Buzzer Short Ring Long Ring Long Ring Long Ring Short Ring Short Ring Long Ring Alarm Ding-Dong Standby * Master code Start Menu 0 Sub Menu 0 Setting White Red White Flash Red Orange Master code # Master * code # Logo LED Light indication 5 6 9 Administrator setting New master code # Repeat new master code # (Note: Code length:6~8 digits, factory default :888888) Read Manager Add Card Read Manager Delete Card Read duress card (Zone ) Read duress card (Zone ) Remarks st 8-digit duress PIN # (Zone ) (Note: The digit must be ) st 8-digit duress PIN # (Zone ) (Note: The digit must be ) 0000 # (Note: This is a dangerous option, so use with care) Read card User ID number # read card Card number # ID number # Card number # User Setting for Zone. The user ID number is any number among - 000.. Card number must be 8 or 0 digits, if the card number is less than 8 or 0 digits, input 0 before the card number. Users can be added continuously without exiting programming mode Functions Change the master code Set Manager Add Card Set Manager Delete Card To set duress users (Note: There are only one duress card and one PIN available for each Zone. When input duress PIN/card, the door will open, at the same time, the external alarm operates.) Delete ALL users To add Card users 5 6

Master * code # 5 User ID number # PIN #. The user ID number is any number among - 000. st. The PIN is any -6 digits, digit must be To add PIN users with the exception of which is reserved. Users can be added continuously without exiting programming mode Add the card as for a card user Press * exit from the programming mode, then allocate the card a PIN as follows: * Read card # PIN# Repeat PIN # Card number # Read Card User ID number # Note: > Users can be deleted continuously without exiting programming mode > To delete Card and PIN users just delete the card To add Card and PIN users To delete Card users by card number To delete Card users by cards To delete Card or PIN users 0 # Entry is by Card ONLY To set valid Card users # Entry is by Card and PIN together To set valid Card and PIN users # Entry is by either Card or PIN To set valid Card or PIN (Factory default setting) users 0~99 # 0 = 50mS, factory default setting: 5 To set door relay time 0 # Every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time. (Factory default setting) Relay Setting- Pulse mode * * * Master code # Master code # Master code # 6 7 ~0 # User ID number # Card number # Card Quantity # Note: The door will open only when read the valid card quantity up to the quantity set. It is only for Card ONLY Mode (Factory default setting: ) The card number must be consecutive Card quantity is between -000 User Setting for Zone st The method is same as Zone, the only difference is the digit of PIN for Zone must be 0 Advanced Application (System setting) To set open door by multi cards To add a series cards users-block Enrollment 0~5# Factory default setting: 0 To set facility code 0# Wiegand reader # Standalone for single door # # # 5# 6# 9# Standalone for two doors With external reader for two doors Two units interlocked for two doors Anti-passback for single door Anti-passback for two doors Automatic mode ( Factory default setting) To set working mode 6~7 # Factory default setting: 6 To set Wiegand format 0~ # Note: When device reset to factory default, the setting is still valid To set keypad transmission format # Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again Relay Setting-Toggle mode 7 8

* * Master code # Master code # 9 0 # # Optional Setting OFF- The device will be in silence except enter the programming mode ON-The device will give the voice when press the keys (Factory default setting ) 9. Advanced Application - Various Working Modes Application Access host can work in 8 modes as below.. Wiegand reader. Standalone for single door To set keypad tone ON or OFF 0 # No door bell function # Built-in door bell - ON(Factory default setting) To set door bell function # External door bell - ON 5 # 0 # # # 0 # # 0 # # Built-in & external door bell - ON Disable keypad backlight Enable keypad backlight(factory default setting) Automatic mode Normally it is off (sleeping mode) but wake up with human approach Disable Enable (Factory default setting) Disable anti tamper alarm (Factory default setting) Enable anti tamper alarm Administrator open the door To set keypad backlight To set logo LED light (Stand-by status) To set anti tamper alarm Administrator open door Administrator open door. Automatic mode (Factory default setting). Standalone for two doors 5. With external reader for two doors 6. Two units interlocked for two doors 7. Anti-passback for single door 8. Anti-passback for two doors 9. Wiegand Reader Mode Common Access Controller 9 0 +V Red GND D0 D LED BZ Black Green White Brown Yellow i Box Access Host (Other Modes) Access Host Access Host (Automatic Mode) (Wiegand Reader) Red Black Green White In this mode, the access host works as reader, it can be done below settings. > Change Master Code > Set Facility Code > Set the card transmission format > Set the keypad transmission format > Set optional setting > Anti-Tamper alarm When LED level is low, Logo light will turn into Green, after 0 seconds or LED level rising, Logo light will back to normal. When BZ level is low, the Buzzer will beep, after 0 seconds or BZ level rising, the Buzzer will back to normal. When the access host worked as reader, both card number and keypad transmits in Wiegand format, the output data are shown by the Low Level of D0 & D cable: D0: Low Level means 0, green cable D: Low Level means, white cable The Pulse Width of Low Level is 00uS, Bit period is.6ms -V Red GND D0 D Black Green White

The digit of card number can be set to 6~7Bit, should be matched with the controller. (Factory default is 6Bit) Keypad transmission can be set in the following modes (modes can be set by user) Model 0: Virtual card number The Reader will transmit the PIN data when it receives the last key (#) press after PIN code st th th th Format: Decimal card number with 0-digit, Facility Code ( ~ digit) + PIN Code ( 5 ~ 0 digit) (Facility code is any digits between 0~5, PIN code is ~6 digits) Example: Facility code: 5 PIN code: 999 Press 999 #, then output format will be: 00500999 PIN code: 999999 Press 999999#, then output format will be 005999999 9. Standalone for Single Door The wiring diagram is shown as below. In this mode, the access host uses for entering the door, it supports connecting external card reader for exiting door. The users of Zone of access host or external card reader can open the door by valid card or PIN. Zone is invalid. Model : -Bit The output data is provided in following format after every key is pressed: Model : 8-Bit The output data is transmitted in following format after every key is pressed: Key Output in hex Output in Binary 0 5 6 7 8 9 0 5 6 7 8 9 A 0000 000 000 00 000 00 00 0 000 00 00 # B 0 Key Output in hex Output in Binary 0 5 6 7 8 9 0 5 6 7 8 9 A 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 # B 0000 L N Input AC00-0V Inside Door Outside Door Red Black Green White Access Host (Enter Door) Door Bell Alarm Door Contact Exit Button N00 N00 Lock (A / B) Short-Circuit Wire 5 6

9. Automatic Mode In this mode, when the access host connects to i Box, it is standalone for single door; If without smart controller, it work as Wiegand reader automatically. 9. Standalone for Two Doors In this mode, stouch-w/skey-w / stouch-s / skey-s users are for controlling two doors. Read valid card or input PIN of Zone on access host, door will open; read valid card or input PIN of Zone on access host, door will open. Remark: The common card for Zone and Zone can only open door. 9.5 With External Reader for Two Doors In this mode, access host is for entering door, and external reader is for entering door. Read valid card or input PIN of Zone on access host, door will open; read valid card or input PIN of Zone on external reader, door will open. Remark: The common card for Zone and Zone can open door on access host, and open door on external reader. N00 N00 N00 N00 L N Input AC00-0V Inside Door Access Host ( Enter Door or Door ) Red Black Green White Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire Outside Door Door Contact Exit Button N00 N00 Lock (A / B) Outside Door External Reader(Enter Door ) Red Black Green White Door Contact Exit Button N00 N00 Lock (A / B)

9.6 Two Units Interlocked for Two Doors The interlocked function is mainly used in banks, prisons, and other places where a higher level security is required. When and only door closed, read valid card/ input PIN on access host, door will open; when and only door closed, read valid card/ input PIN on external reader, door will open. Remark: The valid card/pin is only for users of Zone, users of zone are invalid. 9.7 Anti-passback for Single Door In this mode, access host install outside is for entering door, external reader inside for exiting door, they build up a single door anti-passback system, access host is the anti-passback master unit. The users can only enter door when read valid card on access host, and exit from the inside external reader. If without the entering record from access host, the users cannot exit from the inside reader, also the users can't enter in twice without the first exit record. Remark: This is only for card users of Zone, PIN users of Zone and all users of Zone are invalid. N00 N00 L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Outside Door External Reader(Enter Door ) Red Black Green White Door Bell Alarm Door Contact Door Contact Exit Button Exit Button Lock (A / B) Short-Circuit Wire N00 N00 Lock (A / B) L N Input AC00-0V External Reader( Exit Door ) Red Black Green White Inside Door Outside Door Door Bell Alarm Door Contact Exit Button N00 N00 Short-Circuit Wire Lock (A / B) Access Host ( Enter Door ) Red Black Green White 5 6

9.8 Anti-passback for Two Doors In this mode, access host on door is anti-passback master unit,and external reader on door as the anti-passback auxiliary unit. Then they build up a two doors anti-passback system, which is normally used for parking lot. Application Scene Graph The users can only enter door when read valid card on access host, and exit from door when read valid card on external reader. If without the entering record from door, the users cannot exit from the door, also the users can't enter in twice without the first exit record. Remark: This is only for card users of Zone, PIN users of Zone and all users of Zone are invalid. Access Host Access Host Door Door Access Door Door Host Standalone for single door Figure Figure Standalone for two doors L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Door Bell Alarm Door Contact Exit Button N00 N00 Lock (A / B) Short-Circuit Wire Door Access External Door Host Reader Door External Reader Door Outside Door External Reader(Enter Door ) Red Black Green White Door Contact Exit Button N00 N00 Lock (A / B) Access Host With external reader for two doors Two units interlocked for two doors 7 8

Can t open door after inputting user's PIN Use as user's PIN is the initial value, can't be used to open doors, unless after resetting them to other ~6 digits Access Host (Outside Door) External Reader (Inside Door) Door ( Entrance) Access Host Door (Exit) External Reader Alarm under normal situation No reaction when reading card Light leaking when install access host Machine is not on standby status Leaning on wall closely when install access host Exit by pressing * until logo light turns to white Anti-passback for single door 0. Simple Troubleshooting Anti-passback for two doors Keypad light off Set keypad light mode improperly. Set the keypad light to always On or automatic mode. Under automatic mode, keypad light will on when people approaching Fault Phenomenon Fault Cause Reason & Solution Reading distance is too close. Card problem. Switch power supply interferences card reading. Please use original made card. Wiring power supply and access host shell to ground wire Cannot enter Administrator setting mode Forget master code Reset to Factory Default, default master code is 888888, need to reset conditions and specifications, but users' information is still retained Set user PIN failed. Wrong way of PIN setting. Setting PIN under card reading mode st. Corresponding to users ID, digit of users PIN should be (Zone ) or (Zone ). User PIN cannot be. User PIN only can be -6 digits. setting PIN under card reader mode is not allowed For other issues beyond above, welcome to contact our technicians for more details. 9 0

. Packing List Name Qty Remark Name Qty Remark User Manual User Manual Quick Use Guide Fixing Location Sticker Used for locating installation position. Fixing Location Sticker Used for locating installation position Self Tapping Screw X0 mm Self Tapping Screw X0 mm Rubber Bungs 6X mm Rubber Bungs 6X mm Screw Driver Diode IN 00 Diode Wire Four Wires (Corlor: Yellow X, Red, Black) Manager Cards Manager Add Card & Manager Delete Card User Cards EM Thin Card Self Tapping Screw X5 mm Rubber Bungs 6X0 mm Power Connecting Wire Length: 50 cm Screw Driver