SECTION INTERIOR WOOD DOORS. 1.1 SUMMARY A. Section Includes: 1. Interior flush wood doors // transparent // painted // finish.

Similar documents
Turning nature s beauty into works of art

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Core and Frame Details

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

CLEAR-DIVISIONS CENTERFOLD

SECTION FIRE-RATED WOOD JAMBS

CLEAR-DIVISIONS APERTO

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

CLEAR-DIVISIONS VARIOFOLD

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

PART 1 GENERAL 1.1 SECTION INCLUDES

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

Basic Fire Door Requirements

Architectural Casework Description of Work

How to Install Hardwood Flooring Over a Sub Floor

Technical Data Honeycomb Door Leaf

Guide Specifications for Maple Flooring Systems

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

DIY CABINET REFACING INSTALLATION GUIDE

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

March 14, Installation of Bay, Bow and Garden Windows

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Sun Windows General Information Sun New Construction Window Installation Instructions

SECTION METAL WALL PANELS

CONTEMPORARY - TRANSITIONAL RECEPTION STATIONS

City of San Diego, CWP Guidelines

SECTION 6. Glass Storefront Doors:

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

AMERICAN GOTHIC PLAYHOUSE

Window Installation Instructions

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Pre-Cut Sauna Specifications

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Wood Sound Retardant Door Hardware Information Bulletin

H-Stud Area Separation Wall System

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

A Complete Solution CREATING WALLS THAT DEFINE SPACE

Stair Parts Installation. Tricks

SECTION GUARDA SECURITY WINDOW SCREENS

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

SECTION STANDING SEAM METAL ROOFING

Fire-rated Aluminum Doors

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

FIRESTOPPING & SMOKE SEALS

SECTION PREFORMED METAL STANDING SEAM ROOFING

Fire-Rated Doors and Hardware. A Guide to Field Inspection

INSTALLATION INSTRUCTIONS

Ladder Shelf Plans Final dimensions: 25 L x 21 W x 72 H

Steel Door Institute. Fire Rated Doors and Frames

SECTION SERIES 1500 VINYL PATIO DOORS

Gate Leg Drop Leaf Table Plans

Basement Window Installation Guide Hopper and Sliding

2.9 WINDOW & DOOR BUCKS

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

RACO Interior OfficeFronts. SolutionsII Typical Details. SolutionsII

Built to Last. Built for Beauty. Good. Solid. Logix. TM

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

Automatic Door Selection Guide

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Easy Six Cube Bookshelf. Copyrighted Material. Page 1

2. Division 05 Structural Steel Framing for steel framework requirements

Office of the State Fire Marshal. Fire Rated Doors

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Preformed Metal Roofing and Siding

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

TRADITIONAL RECEPTION STATIONS

DE Frame with C Series Sidelight

How To Test For An Architectural Test

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

Introduction...COMB-2 Design Considerations and Examples...COMB-3

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

Clad Direct Glaze Window Installation Instructions

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Sidelights & Transoms for A-Series Hinged Doors

Owner s Guide to Understanding Checks in Glued Laminated Timber

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

3-Part Specification Railing Cable Systems

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

B. Related categories: The following categories contain requirements that relate to this section:

Active and Passive Sash Replacement

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

Code of Practice for fire resisting metal doorsets

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Simplified Steel Stair Design for Commercial and Institutional Buildings

Transcription:

SECTION 08 14 00 INTERIOR WOOD DOORS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. See VA Standard Details for door types and designations. 3. See VA Physical Security Design Manual for security requirements. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Interior flush wood doors // transparent // painted // finish. SPEC WRITER NOTE: Retain special application flush wood doors required for project. a. Fire rated doors. b. Smoke rated doors. c. Acoustical doors. d. Dutch doors. 2. Interior stile and rail wood doors // transparent // painted // finish. 1.2 RELATED REQUIREMENTS SPEC WRITER NOTE: Update and retain references only when specified elsewhere in this section. A. Paints and Coatings and Composite Wood and Agrifiber VOC Limits: Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS. B. Door Hardware including hardware location (height): Section 08 71 00, DOOR HARDWARE. C. Installation of Doors and Hardware: // Section 08 11 13, HOLLOW METAL DOORS AND FRAMES // Section 08 71 00, DOOR HARDWARE //. D. Door Finish: Section 09 06 00, SCHEDULE FOR FINISHES. 1.3 APPLICABLE PUBLICATIONS A. Comply with references to extent specified in this section. B. American National Standards Institute/Window and Door Manufacturers Association (ANSI/WDMA): 08 14 00-1

1. I.S. 1A-13 - Architectural Wood Flush Doors. 2. I.S. 6A-13 - Interior Architectural Stile and Rails Doors. C. ASTM International (ASTM): 1. E90-09 - Laboratory Measurements of Airborne Sound Transmission Loss of Building Partitions and Elements. D. National Fire Protection Association (NFPA): 1. 80-16 - Fire Doors and Other Opening Protectives. 2. 252-12 - Fire Tests of Door Assemblies. E. UL LLC (UL): 1. 10C-09 - Positive Pressure Fire Tests of Door Assemblies. F. Window and Door Manufacturers Association (WDMA): 1. TM 7-14 - Cycle-Slam Test. 2. TM 8-14 - Hinge Loading Test. 3. TM 10-14 - Screw Holding Capacity. 1.4 SUBMITTALS A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Submittal Drawings: 1. Show size, configuration, and fabrication and installation details. 2. Include details of // glazing // louvers //. 3. Indicate project specific requirements not included in Manufacturer's Literature and Data submittal. C. Manufacturer's Literature and Data: 1. Description of each product. 2. // Fire rated doors showing conformance with NFPA 80 //. D. Samples: SPEC WRITER NOTE: Paragraph D., delete subparagraph No. 1 on projects not involving large numbers of wood doors. Delete subparagraph No. 2 on projects where no transparent door finishes are required. Samples are not required for projects involving 10 wood doors or less. 1. Corner section of flush veneered door 300 mm (12 inches) square, showing details of construction, labeled to show grade and type number and conformance to specified standard. 2. Veneer sample 200 mm by 275 mm (8 inch by 11 inch) showing specified wood species sanded to receive a transparent finish. Factory finish veneer sample where the prefinished option is accepted. 08 14 00-2

E. Sustainable Construction Submittals: 1. Low Pollutant-Emitting Materials: SPEC WRITER NOTE: Retain sustainable construction submittals appropriate to product. a. Show volatile organic compound types and quantities. F. Test Reports: Indicate // each product complies // products comply // with specifications. 1. Screw Holding Capacity Test. 2. Cycle-Slam Test. 3. Hinge-Loading Test. G. Operation and Maintenance Data: 1. Care instructions for each exposed finish product. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. Regularly and presently manufactures specified products. 2. Manufactures specified products with satisfactory service on five similar installations for minimum five years. 1.6 DELIVERY SPEC WRITER NOTE: Packaging is required to be reinstalled on doors after installation. See Part 3 Article PROTECTION. A. Deliver products in manufacturer's original sealed packaging. 1. Minimum 0.15 mm (6 mil) polyethylene bags or cardboard packaging to remain unbroken during delivery and storage. B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, // color, // and manufacture date. 1. Identify door opening corresponding to Door Schedule. C. Before installation, return or dispose of products within distorted, damaged, or opened packaging. 1.7 STORAGE AND HANDLING A. Store products indoors in dry, weathertight // conditioned // facility. 1. Store doors according to ANSI/WDMA I.S. 1A. B. Protect products from damage during handling and construction operations. 08 14 00-3

1.8 FIELD CONDITIONS A. Environment: 1. Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum 48 hours before installation. 2. Work Area Ambient Temperature Range: 21 to 27 degrees C (70 to 80 degrees F) continuously, beginning 48 hours before installation. 3. Install products when building is permanently enclosed and when wet construction is completed, dried, and cured. a. Comply with door manufacturer's instructions for relative humidity. 1.9 WARRANTY SPEC WRITER NOTE: Always retain construction warranty. FAR includes Contractor's one year labor and material warranty. A. Construction Warranty: FAR clause 52.246-21, "Warranty of Construction." SPEC WRITER NOTE: Specify extended manufacturer's warranties for materials only. B. Manufacturer's Warranty: Warrant interior factory finished // flush // stile and rail // wood doors against material and manufacturing defects. SPEC WRITER NOTE: Specify customarily available warranty period for specified products. 1. Warranty Period: Lifetime of original installation. 08 14 00-4

SPEC WRITER NOTES: 1. Use 44 mm (1-3/4 inch) thick doors for medical facilities, nursing homes and domiciliary buildings. 2. Use 35 mm (1-3/8 inch) thick doors for office buildings, unless facility requests 44 mm (1-3/4 inch) thick doors or doors are fire rated. 3. If 35 mm (1-3/8 inch) doors are specified, ensure that they are coordinated with frame details on the Drawings. PART 2 - PRODUCTS 2.1 PRODUCTS - GENERAL A. Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES. B. Provide each product from one manufacturer. C. Sustainable Construction Requirements: SPEC WRITER NOTE: 1. Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS includes comprehensive product list setting VOC limits for low-emitting materials. 2. Retain subparagraphs applicable to products specified in this section. 1. Low Pollutant-Emitting Materials: Comply with VOC limits specified in Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS for the following products: a. Paints and coatings. b. Composite wood and agrifiber. 2.2 FLUSH WOOD DOORS A. General: 1. ANSI/WDMA I.S. 1A, Extra Heavy Duty. 2. Adhesive: Type II. 3. Core: Structural composite lumber, except when mineral core is required for fire rating. 4. Thickness: // 35 mm (1-3/8 inch) // 44 mm (1-3/4 inches) // unless otherwise shown or specified. SPEC WRITER NOTE: For face veneer other than those specified below see ANSI/WDMA I.S. 1A, Section A-8, Flush Door Face Veneer Characteristics, regarding AA and A grade door faces. See 08 14 00-5

B. Faces: 1. ANSI/WDMA I.S. 1A. Section A-3, Appearance of Individual Veneer Leaves; Section A-4, Matching Between Individual Veneer Leaves; Section A-5, Assembly of Spliced Veneer Leaves on Door Face; and Section A-6, Appearance of Doors in Pairs or Sets. For highest quality paint finish, specify only medium density overlay faces. 2. One species throughout project unless scheduled or otherwise shown. 3. Transparent Finished Faces: // Premium Grade. rotary cut, // white maple // white birch // red oak // white oak // //. a. // A Grade // AA Grade // face veneer. SPEC WRITER NOTE: Specify lay up of veneer leaves. For rotary cut veneers, no matching within each door face is possible. Premium grade requires center balance book matching. Consider specifying slip matched veneers and running matched faces if a cut other than rotary is selected. b. Match face veneers for doors for uniform effect of color and grain at joints. c. Door Edges: Same species as door face veneer, except maple is acceptable for stile face veneer on birch doors. d. In existing buildings, where doors are required to have transparent finish, use wood species, grade, and assembly of face veneers to match adjacent existing doors. 4. Painted Finishes: Custom Grade, mill option close grained hardwood, premium or medium density overlay. 5. Factory sand doors for finishing. C. Wood For Stops, Louvers, Muntins and Moldings For Flush Doors Required to Have Transparent Finish: 1. Solid wood of same species as face veneer, except maple is acceptable on birch doors. 2. Glazing: a. On non-fire-rated doors, use applied wood stops nailed tightly on room side and attached on opposite side with flathead, countersunk wood screws, spaced approximately 125 mm (5 inches) on center. 08 14 00-6

3. Wood Louvers: a. Door manufacturer's standard product, fabricated of solid wood sections. b. Wood Slats: minimum 5 mm (3/16 inch) thick. c. Stiles routed out to receive slats. d. Secure louvers in prepared cutouts with wood stops. D. Stiles and Rails: 1. Composite material having screw withdrawal force greater than minimum performance level value when tested according to WDMA TM 10. 2. Provide adequate blocking for bottom of doors having mechanically operated door bottom seal meeting or exceeding performance duty level per WDMA TM 10 for horizontal door edge screw holding. 3. Rabbeted transom meeting rail edges match face veneers of doors. // Bottom rail of transom panel match face veneer on non-rabbeted meeting rail edge. // E. Fire-Rated Wood Doors: 1. Fire Resistance Rating: a. B Label: 1-1/2 hours. b. C Label: 3/4 hour. 2. Labels: SPEC WRITER NOTE: Do not use 60 minute doors and 20 minute doors. Solid core door, 44 mm (1-3/4 inches) gives 20 minute performance. Coordinate fire door rating with wall or barrier assembly rating. a. Comply with NFPA 252, UL 10C, and labeled by qualified testing and inspection agency showing fire resistance rating. b. Metal labels with raised or incised markings. 3. Performance Criteria for Stiles of Doors Utilizing Standard Mortise Leaf Hinges: a. Hinge Loading: WDMA TM 8. Average of 10 test samples for Extra Heavy Duty doors. b. Direct Screw Withdrawal: WDMA TM 10 for Extra Heavy Duty doors. Average of 10 test samples using a steel, fully threaded #12 wood screw. c. Cycle-Slam: 1,000,000 cycles with no loose hinge screws or other visible signs of failure when tested according to WDMA TM 7. 4. Hardware Reinforcement: 08 14 00-7

a. Provide // fire // smoke // rated doors with hardware reinforcement blocking. b. Size of lock blocks as required to secure hardware specified. c. Top, Bottom and Intermediate Rail Blocks: Minimum 125 mm (5 inches) by full core width. d. Reinforcement blocking in compliance with labeling requirements. e. Mineral material similar to core is not acceptable. 5. Other Core Components: Manufacturer's standard as allowed by labeling requirements. 6. Glazed Vision Panel Frame: Steel approved for use in labeled doors. 7. Astragal: Steel type for pairs of doors. F. Smoke Barrier Doors: SPEC WRITER NOTE: Astragals are not always required for fire rated doors. With an astragal, there will be an active and an inactive leaf. If both have exit devices, the inactive leaf will not open. 1. Glazed Vision Panel Frame: Steel approved for use in labeled doors. SPEC WRITER NOTE: Astragals are not required for smoke rated doors. 2. Astragal: Steel type for pairs of doors, including double egress doors. G. Sound Rated Doors: SPEC WRITER NOTE: Standard flush doors with applied seals can achieve STC 35. If greater STC is required, a tested door, frame, and hardware assembly must be specified. 1. Fabricated as specified for flush wood doors with additional construction requirements to comply with specified sound transmission class (STC). 2. STC Rating of door assembly in place when tested according to ASTM E90 by independent acoustical testing laboratory minimum // 35 // //. 3. Accessories: a. Frame Gaskets and Automatic Door Bottom Seal: As specified in Section 08 71 00, DOOR HARDWARE. H. Dutch Doors: 08 14 00-8

1. Consist of two sections, each fabricated as specified for flush doors. 2. Construct shelf as detailed, from clear hardwood stock of same species as face veneer of door. 3. Place shelf on top of lower section of door and support as shown with a pair of wood or wrought steel brackets. 4. Prime steel brackets for finish painting. 2.3 STILE AND RAIL WOOD DOORS A. Doors: ANSI/WDMA I.S. 6A; Grade // Premium, // Custom, // size and design shown on drawings. B. Species: Ponderosa pine. C. Door Panels: 1. Grain of face of panels parallel with longest dimensions of panel. 2. Flat panels: Veneered composite core, minimum 16 mm (5/8 inch) thick. 3. Raised panels: Unless otherwise shown, thickness of raised panels minimum the following: SPEC WRITER NOTE: Fire-rated stile and rail doors are only available 44 mm (1-3/4 inch) thick. a. For 35 mm (1-3/8 inch) and 44 mm (1-3/4 inch) thick doors: 28 mm (1-1/8 inch) thick. 4. Where armor plate is required for paneled doors, provide panels with plywood fillers, glued in place, and finished. D. Stops and Molds: 1. Solid sticking both sides, same material as stiles and rails, coped joints. 2. Glazed Vision Panel Frame: Applied wood stops nailed on interior side of door. E. Louvers: Size as shown. 2.4 FABRICATION A. Factory machine interior wood doors to receive hardware, bevels, undercuts, cutouts, accessories and fitting for frame. 1. Factory fit fire rated doors according to NFPA 80. B. Rout doors for hardware using templates and location heights specified in Section 08 71 00, DOOR HARDWARE. 08 14 00-9

C. Factory fit doors to frame, bevel lock edge of doors 3 mm (1/8 inch) for each 50 mm (2 inches) of door thickness // undercut where shown //. D. Clearances between Doors and Frames and Floors: 1. Fire Rated Doors: Comply with NFPA 80. a. Doors with Automatic Bottom Seal: Maximum clearance 10 mm (3/8 inch) at threshold. b. Other Door Bottoms: Maximum 3 mm (1/8 inch) clearance at the jambs, heads, and meeting stiles, and a 19 mm (3/4 inch) clearance at bottom, except as otherwise specified. 2. Door Jambs, Heads, and Meeting Stiles: Maximum 3 mm (1/8 inch). E. Provide cutouts for // glazed // and louver // openings. F. Finish surfaces, including both faces, top and bottom and edges of the doors smooth to touch. G. Identify each door on top edge. 1. Mark with stamp, brand or other indelible mark, giving manufacturer s name, door s trade name, construction of door, date of manufacture and quality. 2. Mark door or provide separate certification including name of inspection organization. 3. Identify door manufacturing standard, including glue type. 4. Identify veneer and quality certification. 5. Identification of preservative treatment for stile and rail doors. SPEC WRITER NOTE: If there are more than 10 doors at any project, factory apply transparent finish. 2.5 FINISHES A. Field Finished Doors: Seal top and bottom edges of doors with two coats of catalyzed polyurethane or water resistant sealer. B. Factory Transparent Finish: 1. Factory finish // flush // stile and rail // wood doors. a. ANSI/WDMA I.S. 1A Section F-3 Finish System Descriptions for System 5, Conversion Varnish or System 7, Catalyzed Vinyl. b. Use stain when required to produce finish specified in Section 09 06 00, SCHEDULE FOR FINISHES. 08 14 00-10

PART 3 - EXECUTION 3.1 PREPARATION A. Examine and verify substrate suitability for product installation. 1. Verify door frames are properly anchored. 2. Verify door frames are plumb, square, in plane, and within tolerances for door installation. B. Protect existing construction and completed work from damage. C. Install astragal on active leaf of pair of smoke doors and one leaf of double egress smoke doors. 3.2 INSTALLATION A. Install products according to manufacturer's instructions // and approved submittal drawings //. 1. Install fire rated doors according to NFPA 80. 2. When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration. 3.3 PROTECTION A. After installation, place shipping container over door and tape in place. 1. Do not apply tape to door faces and edges. B. Provide protective covering over exposed hardware in addition to covering door. C. Maintain covering in good condition until removal is directed by Contracting Officer's Representative. - - E N D - - 08 14 00-11