BS-200 Chemistry Analyzer MM-M /14

Similar documents
Unleash Your Potential

Pointe Scientific, Inc. Instrument Application

COBAS INTEGRA 400 plus

Pointe Scientific, Inc. Instrument Application

cobas c 111 analyzer Small box. Big performance

AU 400 T H E V I S I B L E D I F F E R E N C E A N A L Y S E R S Y S T E M F O R C L I N I C A L C H E M I S T R Y

Clinical Chemistry Line

cobas c 311 analyzer

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

MEDICAL NUTRITION THERAPY (MNT) CLINICAL NUTRITION THERAPY Service Time CPT Code

Discover Your Potential

Discover Your Potential

FS FSC. Abbreviations in common use. Fluid-stable, ready-to-use reagent. Fluid-stable concentrated reagent for measurement on Olympus AU systems

HumaStar 100 HumaStar 200

Room Temp: 8 Hr. Room Temp: 8Hr. Room Temp: ASAP. Refrigerated (2-8C): 3D. Room Temp: ASAP. Refrigerated (2-8C): 3D

Professional Product List 2015

CTSC Clinical Laboratory. Clinical Laboratory Services CTSC. Clinical & Translational Science Center

AU480 Chemistry Analyzer In-Lab Training Manual

Case 2:10-md CJB-SS Document Filed 05/03/12 Page 1 of 5 EXHIBIT 12

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Adams Memorial Hospital Decatur, Indiana EXPLANATION OF LABORATORY TESTS

Integrating Automated Systems for Regulated Bioanalysis Farmen, R.H., Struwe, P. and Groeschl, M.

Collection Instructions for ARUP Drug Screen Kit #49204

SOLUTIONS FOR ENVIRONMENTAL ANALYSIS

Biochemistry Validation Form

History of Innovation

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Clinical Laboratory Parameters for Crl:CD(SD) Rats. March, Information Prepared by Mary L.A. Giknis, Ph.D. Charles B. Clifford, D.V.M., Ph.D.

PROFICIENCY TESTING. Clinical Laboratory Improvement Amendments (CLIA) DOs and DON Ts. Brochure # 8

Central Government Laboratory Department of Health and Environment

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Presents: Insider tips for the life insurance medical exam. Know what they are testing for--and how to get the best results.

BC Auto Hematology Analyzer

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT

INNOVATION TO MEET YOUR NEEDS

MOSAIC DES MOINES Alcohol/Drug Free Workplace Policy

Toxicology CPT Code Changes for 2016

The Medical Laboratory Licensing Regulations, 1995

for patient monitoring

Amino Acid Analyzer L-8900

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

Practical Aspects of Drug Testing in Human Hair

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

ESS Method 130.1: General Auto Analyzer Procedures

Acute Pancreatitis. Questionnaire. if yes: amount (cigarettes/day): since when (year): Drug consumption: yes / no if yes: type of drug:. amount:.

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Coding and Payment Guide for Laboratory Services. An essential coding, billing, and payment resource for laboratory and pathology services

The potential of oral fluid as a specimen in various drug testing programs

ORGANIC SAMPLE PREPARATION

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

CORMAY CONTROL SERUM HN CORMAY CONTROL SERUM HP

Basic Lessons in Laboratory Quality Control

FULL LABORATORY to HOT LABORATORY DR. DAVID OLEESKY

DRUG SCREENING POLICY AND PROCEDURES Effective August 31, 2015

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

USEPA Electrode Method Method 8156

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

PAYMENT POLICY STATEMENT

6 H2O + 6 CO 2 (g) + energy

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Uscn Life Science Inc. Wuhan

Quaternary Ammonium Compounds DOC

June 2016 Updated Crosswalk:

C. The prospective employee must thoroughly read the LFCC Pre-Employment Drug

Gallery, Gallery Plus and Gallery Plus Beermaster

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

EQUIPMENT CALIBRATION/MAINTENANCE

TOTAL PROTEIN FIBRINOGEN

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

LAB PROCEDURE Alpha-Amino Nitrogen by NOPA

EXECUTIVE BLOOD WORK PANEL

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Hair Drug & Alcohol Testing FAQs

Number: TBD EFFECTIVE DATE: JULY 31, 2000 PROCEDURE STATEMENT

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

And Now, Presenting...

Protease Peptide Microarrays Ready-to-use microarrays for protease profiling

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

HELPING YOUR BUSINESS DO MORE Webinar Series

Drug Testing Reference Tables for Drug Courts

Carcinoembryonic Antigen (CEA)

GeneXpert Technology. Indira Soundiram 2012

Creatine Kinase Assay Kit

Implementation Guide

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

Malondialdehyde (MDA) ELISA

What Does the Drug Test Tell Us

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Blood Glucose Monitoring: The Facts about Accuracy

Interagency Guideline on Opioid Dosing for Chronic Non-cancer Pain (CNCP)

ab Protein Sumoylation Assay Ultra Kit

limit to percentage levels, a limited working range translates

Transcription:

BS-200 Chemistry Analyzer MM-M1111-05 01/14

BS-200 Snapshot Features & Benefits Who Benefits Most from the BS-200

Product Summary More than 4,000 units sold worldwide Small bench-top footprint (34x28x25 inch) Broad test menu to meet your wide needs for chemistry testing Unsurpassed reliability, i.e., MTBF greater than twelve months Excellent performance, great correlation results with Hitachi 917 and AU400

Product Fact Sheet Discrete, random access, automated Up to 330 tests per hour with ISE 40 positions for samples and 40 positions for reagents Reversed optic system with 8 wavelengths: 340-670nm Built-in ISE module and internal sample/reagent bar code reader On-board reagent refrigeration Bi-directional LIS interface Unlimited storage of test results and QC files, supporting Windows 7/Vista/XP/2000 Automatic probe cleaning, liquid level detection, depth adjustment and disposable cuvettes ensures minimal carryover Probe collision protection and reagent pre-heating Micro sample and reagent consumption

Simple Design, Robust Features Reagent/Sample Disk 40 positions for reagents and 40 for samples 24 hour non-stop on-board reagent refrigeration Optional multiple disks Freedom of programming assays and samples/stat/qc/cal at any position you want Wash Wells Wash the mixing bar and probe after every movement Independent Mixer Mixing reagents and sample Reagent/Sample Probe Liquid Level Detection Auto Depth Adjustment Reagent/Sample Pre-heating Auto Wash (Inside/Outside) Probe Collision Protection Minimal Sample Volume (3µl~45µl) Reaction Chamber Disposable cuvettes to eliminate carryover Excellent temperature control Minimal reaction volume <=180µl to save reagents Lamp life 2,000 hours 8 wavelengths

General Work Flow of BS-200 Double-Reagent Test Incubation

Test Menu 28 Barcoded Reagents Albumin BUN (Urea Nitrogen) Fructosamine autoldl Alkaline Phosphatase Calcium ɣ-glutamyl Transferase Lipase ALT Carbon Dioxide Glucose Hexokinase Magnesium Amylase Cholesterol Hemoglobin A1c Phosphorus AST Creatine Kinase autohdl Protein Total Bilirubin Direct Creatinine Iron Total Triglycerides Bilirubin Total CRP(hs) Lactate Dehydrogenase Uric Acid 13 Highly Complex Open Channel Reagents 16 Highly Complex Drugs of Abuse Alcohol Ammonia Creatinine Enzymatic CK-MB Glucose Oxidase G6PD HDL PEG HDL Mg/Dex Homocysteine Lactate Lp(a) Microalbumin Microprotein 6-Acetylmorphine Amphetamine Barbiturate Benzodiazepine Buprenorphine (Suboxone) Cannabinoid (THC) Cocaine Metabolite Ecstasy (MDMA) Ethanol Methadone Methadone Metabolite (EDDP) Methamphetamine Opiates Oxycodone Phencyclidine Propoxyphene

BS-200 Snapshot Features & Benefits Who Benefits Most from the BS-200

Designed with a busy lab in mind Discrete, random access and automated sample processing User-friendly software, supporting Windows 7/Vista/XP/2000 High throughput for a compact size (330 tests/hr w ISE) 40 positions for samples, 40 for reagents, and additional virtual and physical sample/reagent disk No fixed position for sample, STAT, control, or calibrator Zero daily maintenance: visual checking only Auto QC function

Designed with a busy lab in mind STAT sample priority Internal barcode readers for both samples and reagents ensures positive sample and reagent identification On-board reagent refrigeration with 24-hour non-stop cooling allows greater reagent on-board stability Dual switches allow 24-hour reagent refrigeration while turning off other on-board mechanisms

High performance safeguards the integrity of patient results Advanced Dispensing System: Internal and external probe washing after each dispensing Liquid level detection to avoid inaccurate sampling Automatic probe depth adjustment when dispensing, so as to avoid bubbles and carry-over Reagent probe pre-heating function to reach 37 more quickly. Probe collision protection

High performance safeguards the integrity of patient results Stable temperature control for both reagent and reaction chambers Highly accurate motors and syringes: 3-45ul sample volume in 0.5ul increments for accuracy and precision Carry-over avoiding program Independent Mixer Automatic cuvette and R1 blank checking to ensure accurate result

High performance safeguards the integrity of patient results What do these features mean to your customer? Safe Operation Accurate Results Elimination of Contamination

State-of-the-Art Technology & Design User-friendly software, supporting Windows Vista/XP/2000 Real-time Monitoring Dynamic display of running status and sample info Real-time monitoring of residual reagent volume Optimized calibration curve Sample Wheel Reagent Wheel Test Running Status Reaction Curve

State-of-the-Art Technology & Design Example: Reagent Monitoring Screen

State-of-the-Art Technology & Design Example: Sample Monitoring Screen

State-of-the-Art Technology & Design Auto QC Auto dilution and pre-dilution of sample and calibrator Auto rerun of abnormal results Auto print-out after sample run Allows easy programming of batch work QC on profiles Up to 10 programmable disks Customization of calculation formula, i.e., microalbumin/creatinine Unlimited storage of test results and QC files Built-in Online Operation Manual in Operational Software An instrument that talks to you Audible alarm (volume adjustable) Many more

Significant Cost Savings Low-cost instrument with same features and precision available on high-end analyzers Quality low-cost reagents Minimum reaction volume: <=180µl Low-cost cuvettes: costs for cuvette cleaning agents, distilled water or lost time waiting for washing is eliminated Low-maintenance instrument Long-life lamp (2,000 hours) 6-month electrodes shelf-life guarantee

BS-200 Snapshot Features & Benefits Who Benefits Most from the BS-200

Who Benefits Most from the BS-200 Extreme low-cost in relation to its throughput and state-of-the-art features - a viable and profitable solution for labs with annual test volumes of 30,000 to 125,000 tests A broad test menu fits the needs of general chemistry labs and specialty labs, i.e., pain management, drugs of abuse, immunoprotein testing, etc. POLs or small hospitals with less than 125,000 tests/year POLs with test volumes too small to afford other analyzers Departments of some large hospitals who want to spin off from the central lab and have their own in-house chemistry analyzer dedicated for one or more specialty tests, i.e. glucose, special proteins, etc.

Thank You