NTG5110 & NTG5220. Homeowner s Guide. Description. Time and Day Adjustment. Setpoint Configuration. Operating Modes. Programmable Thermostats

Similar documents
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

EK908FHL - Thermostat for floor heating

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ACONT900AC43UA Communicating, Programmable Comfort Control

Model Owner s Manual. Español - P. 19 Français - P. 39

HEAT PUMP PROGRAMMABLE THERMOSTAT

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Thermostat with display

Installation and Operation Back-UPS 1250, 1300, 1500

LIGHTING CONTROL PANEL

Operation Guide 3M-22

User Manual THR840DUK Digital Thermostat

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

CT3200 Programmable Thermostat

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Mini Timer Owner's Manual. Model MT13A

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Wireless 7 Day Programmable Room Thermostat

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TC-9102 Series Surface Mount Temperature Controllers

Installation Instructions

Digi-Motor Installation Guide

Back-UPS Pro 1300/1500 Installation and Operation

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

LOS 2500 SUPER CEILING SENSOR. Installation Manual

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Wireless Thermostats 230v and Battery Operated Instruction Manual

ES-LCD User Control SD Card Location

User Manual. Humidity-Temperature Chart Recorder. Model RH520

LCD5500Z / PKP-LCD v3.x Installation Instructions

1 For All Non-Programmable Digital Thermostat

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

INSTALLER S & OWNER S MANUAL

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

CO2 Alarm. Operation. Application

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

INSTALLATION & SERVICE MANUAL. Display Panel

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

HEAT HEAT COOL HEAT PUMP COOL

ADEMCO 4500 Thermostat

Sensi TM. Wi-Fi Programmable Thermostat SCHEDULING GUIDE. Version: March Emerson Electric Co. All rights reserved.

Fused Spur Time Switch

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Ducoterra Radiant Heating Panel Installation Manual

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

How To Control A Thermostat

Niko Home Control. Installation Manual

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Single Station Remote Alarm

Drayton Digistat +2RF/+3RF

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

INSTALLATION INSTRUCTIONS

T8131C, T8132C Programmable Thermostat

GB/DAS User Instruction

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!


ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Operation and Installation Manual

Car Alarm Series 2 B 2 Buttons

Article: Version:

Die-Cast Metal, Motion- Activated Post Light

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

WHITE-RODGERS COMFORT-SET 90 SERIES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Mode Switch. Fan Switch Menu button Program button

SECTION LOW VOLTAGE LIGHTING CONTROLS

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

VEHICLE SECURITY SYSTEM G25/G20

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

LED MOTION ACTIVATED FLOOD LIGHT

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX

Transcription:

NTG5110 & NTG5220 Homeowner s Guide Programmable Thermostats Nuheat s NTG5110 & NTG5220 programmable thermostats can be used to control the ambient air temperature or floor temperature. You can select among the following temperature control modes: A mode: F mode: AF mode: Description Power switch / reset GFCI Appears when the setpoint is displayed Operating mode icons Set day Set time Set programming Erase programming Select Operating Mode / Return controls the ambient air temperature controls the floor temperature using an external temperature sensor controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor Time and day Temperature Comfort, Economy and Vacation icons Heating indicator Ground fault indicator Comfort setpoint Economy setpoint Vacation setpoint Temperature adjustment 1. Memory Backup: In the event of a power failure, an internal circuit will maintain the programming and time. However, the time will have to be re-set if the power failure exceeds 6 hours. Time and Adjustment Set the time using the and buttons. Set the day using the button. Press to exit. Setpoint Configuration The Comfort, Economy and Vacation settings respectively represent the temperatures that you wish to have during the day ( ), at night or while you are away at work ( ), or while you are away for an extended period ( ). 3. 4. Period number Temperature control mode icons MANUAL AUTO Backlight button Lights up display, automatically turns off after 12 seconds Operating Modes Allows you to manually adjust the temperature setpoint. To activate this mode, press to display the icon. Set the desired temperature using or select one of the pre-programmed settings (, or ). Executes the default schedule or your own programming. Use this mode to maximize energy savings. To activate it, press to display the icon. The or icon indicates which temperature setting is used. Also, the icon of the period number will be shown. (i.e. ) 2. This thermostat is pre-programmed with the following default Comfort, Economy and Vacation setpoints. Icon Setpoint F mode A/AF mode Comfort 88 F (31 C) 70 F (21 C) Economy 73 F (23 C) 63 F (17 C) Vacation 50 F (10 C) 50 F (10 C) If the default temperature settings suit your personal preferences, skip the following section. To Modify the Default Setpoints: To modify the Comfort temperature, select the desired temperature using the buttons and hold the button until the icon is displayed (app. 3 seconds). To modify the Economy temperature, select the desired temperature using the buttons and hold the button until the icon is displayed (app. 3 seconds). To modify the Vacation temperature, select the desired temperature using the buttons and hold the button until the icon is displayed (app. 3 seconds). Press the button to exit this function and return to the normal operating mode. NTG5110 & NTG5220 400-115-006-E 10/11/06 1/3

Default Schedule This thermostat is pre-programmed with the following default schedule: Periods MON TUE WED THU FRI SAT SUN 88 F 6 AM 6 AM 6 AM 6 AM 6 AM 6 AM 6 AM 73 F 9 AM 9 AM 9 AM 9 AM 9 AM --:-- --:-- 88 F 5 PM 5 PM 5 PM 5 PM 5 PM --:-- --:-- 73 F 11 PM 11 PM 11 PM 11 PM 11 PM 11 PM 11 PM It applies to people who wake up at 6:00 AM, leave for work by 9:00 AM, return home for 5:00 PM and go to sleep at 11:00 PM. If the pre-programmed schedule fits your lifestyle, skip the following section. Modify the Default Schedule First, program your schedule. You can program 4 different periods for each day of the week. For each day, enter: Time you wake up (Period 1) Time you leave for work (Period 2) Time you return home (Period 3) Time you go to bed (Period 4) Press to access the programming mode. Period 1 is displayed ( ). Press to select the day to be programmed (hold for 3 seconds to select all days of the week). NOTE: It is faster to program the same schedule for the entire week, then modify the exception days (i.e. Saturday and Sunday). Press and to program the start time, OR Press to clear a time entry. Press to select the next period. Repeat steps 3 and 4 for remaining periods. When you have completed your programming, press to exit the programming mode. Programming Example: This example applies to people who are home during the week. Comfort period from 6:00 AM to 11:00 PM (Period 1) Economy period from 11:00 PM to 6:00 AM (Period 4) Identical schedule for all days of the week. Press to access the programming mode. Period 1 is displayed ( ). Press and hold for 3 seconds to select every day of the week. Press to enter 6:00 AM for Period 1. Press to select Period 2 ( the time entry (- - : - -). Press to select Period 3 ( the time entry (- - : - -). ) and press to delete ) and press to delete 5. 6. Press to select Period 4 ( 11:00 PM. ) and press to enter When you have completed your programming, press to exit the programming mode. To modify the Saturday and Sunday Schedules: When making modifications, make sure you are in the right period. For example, if you are modifying the time for the time you wake up, make sure you are in Period 1. Press to select Period 1 ( ). Press to select SA (Saturday). Press and to enter the time you wake up on weekends. Press to select Period 4 ( ). Press and to enter the time you go to sleep on weekends. Repeat above steps for Sunday (SU). Press to exit programming mode. Floor Temperature Limits (AF mode only) NOTE: To avoid damaging your floor, follow your floor supplier s recommendations regarding the minimum and maximum floor temperature limits. The minimum and maximum floor temperature limits are 5 C (41 F) and 28 C (82 F) by default. To modify these limits, proceed as follows: Switch the thermostat to Standby. Press and hold the button. Switch the thermostat back to. Release the button when the minimum temperature limit (FL:LO) appears. Set the minimum temperature limit using the buttons. Press the button to display the maximum temperature limit (FL:HI). Set the maximum temperature limit using the Press to exit. Special Features Temporary or Permanent Temperature Bypass: buttons. This operation allows you to temporarily modify the floor temperature while you are in the Automatic mode. Simply press to select the desired temperature, or or button to select the Comfort or Economy settings you have programmed. This temperature will be maintained until the beginning of the next programmed schedule. You can also switch to the Vacation setting for a prolonged absence by pressing. In that case, the temperature bypass is permanent. To return to the normal operating mode, press. If you wish to immediately return to the programmed settings, press. 7. 8. NTG5110 & NTG5220 400-115-006-E 10/11/06 2/3

Early Start Function: This thermostat is equipped with a function that enables it to calculate the optimum time to start the heating system to achieve the desired temperature setting by the programmed time. It could start the heating system as early as 6 hours prior if necessary. Every day, the thermostat will automatically re-evaluate how early to start heating, based on the previous day s performance. The switch on the back of the thermostat is factory-set to Early Start ON. To disable this function, see the Switch Selection section. light Savings Time: The thermostat can automatically re-adjust its time at light Savings Time changeover. Year 2006: When this function is enabled (), the thermostat switches to light Savings Time on the first Sunday of April and to normal time on the last Sunday of October. Year 2007 and on: When this function is enabled (), the thermostat switches to light Savings Time on the second Sunday of March and to normal time on the first Sunday of November. NOTE: The function is disabled (default setting) when the clock loses its setting. Press the button (3 seconds) until DLS appears on the screen. Press the (disabled). to toggle between (enabled) and Off Press the button briefly. The year setting is displayed. Press the to set the current year. Press the button briefly. The month setting is displayed. Press the to set the current month. Press the button briefly. The date setting is displayed. Press the Press to exit. to set the current date. Switch Selection The thermostat can be configured with the following settings: # FUNCTION UP DN 1 Temperature format display F C 2 Early Start ON OFF 3 Temperature control mode a F AF Factory settings a. To select the F mode, place the switch in the F position. To select the AF mode, place the switch in the AF position and ensure that the remote temperature sensor is connected to the thermostat. To select the A mode, place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat. 9. To Modify the Default Settings: Locate the screw at bottom of thermostat. Unscrew. Remove thermostat faceplate. Locate the switches at the back of the faceplate. Set the switches to your preferences. Put the faceplate back on the thermostat. Secure the thermostat with the screw. Technical Specifications Display range: 32 F to 158 F (0 C to 70 C) Ambient setpoint range (A/AF models): 40 F - 86 F (5 C to 30 C) Floor setpoint range (F model): 40 F - 104 F (5 C to 40 C) Floor limit range (AF model): 40 F - 104 F (5 C to 40 C) Warranty This product is guaranteed against workmanship defects for a one-year period following the initial date of purchase. During this period, NUHEAT will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. NUHEAT cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: 6920 Salashan Parway Building D-200 Ferndale, WA 98248 1689, avenue Cliveden V3M 6V5 NUHEAT TM is a registered trademark of Nuheat Industries LTD. 10. 11. As an ENERGY STAR partner, Nuheat has determined that this thermostat meets the ENERGY STAR guidelines for energy efficiency. NTG5110 & NTG5220 400-115-006-E 10/11/06 3/3

R R POWER ON When the unit is power on for the first time, the following appears on-screen: ELECTRICIAN S INSTRUCTIONS FOR MODEL NG110 (120 VAC) INSTALLATION This power base is designed to control electric floor-warming systems. The resistive load must not exceed 1800 watts (NI) @ 120 VAC (15 A). The thermostat is equipped with a Ground Fault Circuit Interrupter (GFCI) and therefore the isolation of the line and load are required for operation. Do not cap all the white wires together. During a ground fault, both line and load will be cut-off. Connect thermostat as shown on diagram. Time (0:00) Floor temperature Manual mode icon ( ) If improperly installed, you will see the LO or HI error message. LO: Floor temperature is below 0 C (32 F); or temperature probe is defective (open) or not connected. HI: *If the heating indicator is also displayed, then the relay is closed and current is going through the load. Floor temperature is above 60 C (140 F); or temperature probe is shorted. Must be installed in accordance with national and local electrical codes. TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. 1 Connecting wires and mounting power base Connect the power base wires to the supply and load using solderless connectors for copper wires. See diagram. Push the excess wire back into the electrical box to prevent interference with the power base. SUPPLY GFCI TEST 1 Adjust the setpoint temperature until the heating indicator ( ) appears on-screen. 2 Press TEST. The test is successful if the GFCI warning light is ON and power is cut-off. The heating indicator ( ) should still appear. 3 Switch power to Standby, then reset to ON. If test fails: A- Verify installation. B- Check the load wires. C- Verify that the thermostat is in heating mode with Heating indicator ON. ce you ve identified the problem, run the GFCI test again. LOAD NOTE: All cables and connections must conform to the local electrical code. WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors. 2 Connecting temperature sensor wire The wire must pass outside the electrical box and follow the wall down to the floor. The sensing probe should be placed in a representative heat area for maximum system performance. The sensing probe should be centered between the wires in the mat. The temperature sensor wire cannot cross any heater wires and the sensing probe must NOT be directly on or adjacent to a heating wire. Secure the power base with the screw. Connect the temperature sensor wire to terminals 3 and 4 on the power base (no polarity needs to be respected). ce the power base is properly installed, mount the faceplate. MOUNTING THE FACEPLATE Keep the thermostat s air vents clean and free from obstructions. NG110 1 Locate the screw at the bottom of the front module. 2 Secure the thermostat with the screw. 3 Turn the power back on. TECHNICAL SPECIFICATIONS Model: NG110 Supply: 120 VAC, 50/60 Hz Load: 15 A maximum Power: 1800 watts (NI) @ 120 VAC Ground Fault Circuit Interrupter (GFCI): Class A (5 ma) Approvals: CSA / C,US Storage: -4 F to 120 F (-20 C to 50 C) WARRANTY This product is guaranteed against workmanship defects for a one-year period following the initial date of purchase. During this period, NUHEAT will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. NUHEAT cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: 880 Grant Avenue 1689 Cliveden Avenue Blaine, WA 98230 V3M 6V5 NUHEAT TM is a registered trademark of Nuheat Industries LTD. 14/05/03 920-112-000-00-1-A

R R POWER ON When the unit is power on for the first time, the following appears on-screen: ELECTRICIAN S INSTRUCTIONS FOR MODEL NG220 (240 VAC) INSTALLATION This power base is designed to control electric floor-warming systems. The resistive load must not exceed 3600 watts (NI) @ 240 VAC (15 A). The thermostat is equipped with a Ground Fault Circuit Interrupter (GFCI) and therefore the isolation of the line and load are required for operation. During a ground fault, both line and load will be cut-off. Connect thermostat as shown on diagram. Time (0:00) Floor temperature Manual mode icon ( ) If improperly installed, you will see the LO or HI error message. LO: Floor temperature is below 0 C (32 F); or temperature probe is defective (open) or not connected. HI: *If the heating indicator is also displayed, then the relay is closed and current is going through the load. Floor temperature is above 60 C (140 F); or temperature probe is shorted. Must be installed in accordance with national and local electrical codes. TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. 1 Connecting wires and mounting power base Connect the power base wires to the supply and load using solderless connectors for copper wires. See diagram. Push the excess wire back into the electrical box to prevent interference with the power base. SUPPLY GFCI TEST 1 Adjust the setpoint temperature until the heating indicator ( ) appears on-screen. 2 Press TEST. The test is successful if the GFCI warning light is ON and power is cut-off. The heating indicator ( ) should still appear. 3 Switch power to Standby, then reset to ON. If test fails: A- Verify installation. B- Check the load wires. C- Verify that the thermostat is in heating mode with Heating indicator ON. ce you ve identified the problem, run the GFCI test again. LOAD NOTE: All cables and connections must conform to the local electrical code. WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors. 2 Connecting temperature sensor wire The wire must pass outside the electrical box and follow the wall down to the floor. The sensing probe should be placed in a representative heat area for maximum system performance. The sensing probe should be centered between the wires in the mat. The temperature sensor wire cannot cross any heater wires and the sensing probe must NOT be directly on or adjacent to a heating wire. Secure the power base with the screw. Connect the temperature sensor wire to terminals 3 and 4 on the power base (no polarity needs to be respected). ce the power base is properly installed, mount the faceplate. MOUNTING THE FACEPLATE Keep the thermostat s air vents clean and free from obstructions. NG220 1 Locate the screw at the bottom of the front module. 2 Secure the thermostat with the screw. 3 Turn the power back on. TECHNICAL SPECIFICATIONS Model: NG220 Supply: 240 VAC, 50/60 Hz Load: 15 A maximum Power: 3600 watts (NI) @ 240 VAC Ground Fault Circuit Interrupter (GFCI): Class A (5 ma) Approvals: CSA / C,US Storage: -4 F to 120 F (-20 C to 50 C) WARRANTY This product is guaranteed against workmanship defects for a one-year period following the initial date of purchase. During this period, NUHEAT will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. NUHEAT cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: 880 Grant Avenue 1689 Cliveden Avenue Blaine, WA 98230 V3M 6V5 NUHEAT TM is a registered trademark of Nuheat Industries LTD. 14/05/03 920-112-001-00-1-A