DT9805 and DT9806. USB Thermocouple Measurement Modules. Key Features: Overview. Specialized Analog Input Design

Similar documents
ECONseries Low Cost USB DAQ

DT9836 Series. BNC Connection Box. OEM Embedded Version

UM A. DT9837 User s Manual

Measuring Temperature withthermistors a Tutorial David Potter

NETWORK ENABLED EQUIPMENT MONITOR

The Universal DAQ Device. Connect and measure immediately!

DATENBLATT USB-DIO32HS USB-DIO32HS-OEM. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

Introduction to Data Acquisition

RF Measurements Using a Modular Digitizer

MH - Gesellschaft für Hardware/Software mbh

minilab 1008 USB Device for Analog and Digital I/O User's Guide

NEW. EVEN MORE data acquisition and test stand automation

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement

Simplify Data Acquisition with a Built-in LXI Web Server

Personal Daq/3000 Series

DAQ in MATLAB HANS-PETTER HALVORSEN,

PCI230+ & PCI260+ MULTI-FUNCTION ANALOG AND DIGITAL INPUT/OUTPUT BOARDS

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Data Acquisition in LabVIEW

Agilent Automotive Power Window Regulator Testing. Application Note

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

Trigno/Vicon System Integration

Cell Phone Vibration Experiment

Conversion Between Analog and Digital Signals

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

USB-TC. Thermocouple Measurement. User's Guide

SignalPad Data Logging and Analysis Software

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

DS1104 R&D Controller Board

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices.

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

Product Functional description Price in CZK

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

4-Channel Thermometer / Datalogger

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Multiplexing and Sampling Theory

Accurate Measurement of the Mains Electricity Frequency

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

AlazarTech SDK Programmer s Guide. Version May 28, 2010

Temperature & Humidity SMS Alert Controller

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

WIRELESS ASSET MONITORING

LAN extensions for Instrumentation

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply

Three Levels of Data-Logging Software from National Instruments

Disturbance Recoder SPCR 8C27. Product Guide

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically

AlazarTech SDK Programmer s Guide. Version June 16, 2011

Sistemi di acquisizione. Grazie al sito National Instruments

EVAL-UFDC-1/UFDC-1M-16

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

FFT Frequency Detection on the dspic


Description: Multiparameter System (4 or 8 channels)

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

LLRF. Digital RF Stabilization System

Wahl C50 Calibrator FEATURES

Test Driven Development of Embedded Systems Using Existing Software Test Infrastructure

Open Architecture Design for GPS Applications Yves Théroux, BAE Systems Canada

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

US-Key New generation of High performances Ultrasonic device

DaqBook/2000 Series and DaqOEM/2000 Series 16-Bit, 200 khz Multifunction Data Acquisition Systems

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Bioreactor Process Plant Powered by NI LabVIEW and NI CompactRIO

The SOLUTION for Gathering Rotary Torque Sensor with Encoder Data

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

User's Guide. Integrating Sound Level Datalogger. Model Introduction

International Journal of Electronics and Computer Science Engineering 1588

IBM AT *-Compatible High Performance Multifunction I/O Boards RTI -834/RTI-835

CHAPTER 11: Flip Flops

S2000 Spectrometer Data Sheet

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Kvaser Mini PCI Express User s Guide

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS

Personal Daq/50 Series USB Data Acquisition Modules

Lab 4 - Data Acquisition

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

USB Smart Power Sensor

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

WINDAQ Data Acquisition and Playback Software

DP Hi-Speed USB 4-Port PCIe Quick Installation Guide

USB Smart Power Sensor

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

HIGH RELIABILITY POWER SUPPLY TESTING

How To Use A High Definition Oscilloscope

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Transcription:

DT9805 and DT9806 USB Thermocouple Measurement Modules The DT9805 and DT9806 low-cost, isolated, USB data acquisiton (DAQ) modules feature integrated signal conditioning designed specifically for thermocouple measurements. Key Features: ±500V galvanic isolation...protects signal integrity Built-in CJC (cold-junction compensation) High accuracy: 0.20 C Compatible with B, E, J, K, N, R, S, T thermocouple types 16SE/8DI analog inputs, 16-bit resolution Up to 50kHz sampling 16 DIO, 2 C/T Optional analog outputs: 16-bits Compatible with LabVIEW and MATLAB Includes free QuickDAQ 2013 software...get up and running quickly Overview The DT9805 and DT9806 bring true plug-and-play temperature measurements to PCs with USB 2.0 or 1.1 ports. Simply attach the DT9805 or DT9806 module to the PC using the supplied USB cable, directly connect up to 7 thermocouples to the screw terminals on the module, and run the free DT Thermocouple Measurement application. Linearized temperature data is returned in degrees C, F, or K. You don t have to open your computer or do any programming. It s that simple. All power is provided from the USB cable to the PC. Figure 1. The DT9805 and DT9806 modules are ideally suited for plug-and-play thermocouple measurements. Pluggable screw terminal blocks allow you to connect thermocouples and other sensor types directly to the module. Specialized Analog Input Design The DT9805 and DT9806 provide a CJC channel on analog input channel 0 that provides 10 mv/ C with an accuracy of 1 (from 5 to 45 C). Seven differential analog input channels are available for connecting B, E, J, K, N, R, S, or T thermocouple inputs. Thermocouple break detection is also provided to set the value to full-scale if an open circuit is detected at the input. USB Interface Micro Controller DC-DC and Power Control The DT9805 and DT9806 modules both feature a Cold Junction Compensation (CJC) channel, 7 differential analog input channels, 8 digital input lines, 9 digital output lines, and 2 counter/timer channels. In addition, the DT9806 provides 2 analog output channels for highresolution, single-value output operations. To add more channels (up to 889 thermocouples), simply add more modules to your system using one or more USB hubs. Dynamic Digital Output Clock Gate Out 500 Volt Isolation Barrier Two 16-Bit User Counter/Timers 8 Digital Outputs High- Speed Data Path Side Control Logic Channel-Gain List (32 Entries) Power 7 Thermocouples (16SE/8DI Analog Inputs) CJC Analog Input MUX Programmable Gain Amplifier (x1, 10, 100, 500) 16-Bit A/D Converter 2048 Sample FIFO 8 Digital Inputs External Clock and Trigger Logic 16-Bit D/A Converter (DT9806 only) Channel 0 Channel 1 Trigger Figure 3. This block diagram shows all the subsystems and user-accessible signals of the DT9805 and DT9806 modules. Clock

All analog inputs are multiplexed to a single 16-bit analogto-digital (A/D) converter. Four programmable gains (1, 10, 100, and 500) are provided to support input signal ranges of ±10 V, ±1 V, ±0.10 V, and ±0.020 V. For thermocouple inputs, which are typically in the range of 20 mv, DT9805 and DT9806 modules provide a dynamic range of 100,000:1 (100 db) to ensure that the input signals are amplified to the full ±10 V range of the A/D converter and digitized to 16 bits for maximum accuracy. Each channel is configurable, allowing you to mix and match input signals according to your needs. In addition, DT9805 and DT9806 modules support autoranging, where the software can determine the appropriate gain based on the input range you specify (in single-value mode). The maximum sampling rate depends on the gain that is used: 50 ksamples/s when the gain is 1 or 10, 10 ksamples/s when the gain is 100, and 2 ksamples/s when the gain is 500. The minimum sampling rate is 0.75 Hz. Flexible Acquisition Modes Using the DT9805 or DT9806, you can acquire a single sample from a single analog input channel or multiple samples from multiple analog input channels. A 32-location channel-gain list gives you the flexibility to sample non-sequential analog input channels, analog input channels with different gains, and digital inputs with the analog input channels you want at the A/D sample rate. The DT9805 and DT9806 provide two ways to cycle through the channel-gain list: Continuous scan mode Choose this mode if you want to accurately control the period between conversions of individual channels in a channel-gain list. Triggered scan mode Choose this mode if you want to accurately control both the period between conversions of individual channels in a channelgain list and the period between each scan, or cycle, through the channel-gain list. This mode is useful when synchronizing or controlling external equipment or when acquiring a buffer of data on each trigger or retrigger. High-Resolution Analog Outputs The DT9806 module provide two DC-level analog output channels for single-value operations. A 16-bit digital-toanalog converter provides high-resolution output values with an output range of ±10 V. Flexible Digital I/O Lines The DT9805 and DT9806 modules feature 8 digital input lines for single-value operations. You can also read all the digital input lines simultaneously with the analog input channels at the A/D clocked rate. The digital input lines can be clock separately as the only channel in the channelgain list at up to 50 ksamples/second. Eight digital outputs are provided for single-value operations. A dynamic digital output line is also provided for synchronizing external devices. You can program the value of this line to change state as an analog input channel is read. User Connections Pin Signal Description Pin Signal Description 1 Analog Input 00/CJC Circuit 28 Digital Input 0 2 Analog Input 08/00 Return 29 Digital Input 1 3 Analog Input 01 30 Digital Input 2 4 Analog Input 09/01 Return 31 Digital Input 3 5 Analog Input 02 32 Digital Input 4 6 Analog Input 10/02 Return 33 Digital Input 5 7 Analog Input 03 34 Digital Input 6 8 Analog Input 11/03 Return 35 Digital Input 7 9 Analog Input 04 36 Digital Ground 10 Analog Input 12/04 Return 37 Digital Ground 11 Analog Input 05 38 Digital Output 7 12 Analog Input 13/05 Return 39 Digital Output 6 13 Analog Input 06 40 Digital Output 5 14 Analog Input 14/06 Return 41 Digital Output 4 15 Analog Input 07 42 Digital Output 3 16 Analog Input 15/07 Return 43 Digital Output 2 17 Analog Ground 44 Digital Output 1 18 Amp Low 45 Digital Output 0 19 Analog Output 0+ 46 Dynamic Digital Output 20 Analog Output 0 Return 47 Digital Ground 21 Analog Output 1+ 48 External Gate 1 22 Analog Output 1 Return 49 User Counter Output 1 23 Digital Ground 50 User Clock Input 1 24 External A/D Trigger 51 Digital Ground 25 External A/D Sample Clock In 52 External Gate 0 26 Digital Ground 53 User Counter Output 0 27 +5V Out 54 User Clock Input 0 2

Programmable Clocks and Triggers For starting analog input measurements, you can select either an internal or external trigger source. Select the internal trigger to start the operation based on a software command. Select an external trigger to start the acquisition based on an external event. To use the external trigger, connect a TTL-level signal to the screw terminal of the module labeled External A/D Trigger. The trigger occurs on the rising edge of this signal. For pacing analog input measurements, you can select either the internal clock source provided by the module or an external clock source. An external clock is useful when you want to pace acquisitions at rates not available with the internal clock or when you want to pace at uneven intervals. To use an external clock, connect a TTLlevel signal to the screw terminal of the module labeled External A/D Sample Clock In. Conversions start on the rising edge of this signal. Multifunction Counter/Timers DT9805 and DT9806 modules feature two 32-bit user counter/timers that you can use for event counting, frequency generation (continuous pulse output), oneshot, and repetitive one-shot operations. You can connect or cascade counters together either in software or by external connections to the screw terminals of the module. Programmable gates, clocks, and output signals are also supported. ±500V Galvanic Isolation Protects Your Data Computers are susceptible to ground-spikes through any external port. These spikes can cause system crashes and may even cause permanent damage to your computer. DT9805 and DT9806 modules feature 500 Volts of galvanic isolation to protect your computer from groundspikes and to ensure a reliable stream of data. User Connections The DT9805 and DT9806 modules provide pluggable screw terminal blocks for connecting all signals. You can remove these screw terminal blocks for easy wiring. Pin assignments are clearly marked on the module for quick setup. Power All power is provided through the USB cable to the module. No external power supply or battery is required. 3

QuickDAQ 2013 QuickDAQ 2013 allows you to acquire and display from all Data Translation USB and Ethernet data acquisition devices that support analog input streaming. Combine QuickDAQ 2013 with Data Translation hardware to acquire data, record data to disk, display the results in both a plot and digital display, and read a recorded data file. Be productive right out of the box with this powerful data logging software. Data can be exported to other applications like Microsoft Excel and The Mathworks MATLAB for more advanced analysis. Two additional options can be purchased to add FFT analysis capabilities to the base package. Key Features: QuickDAQ 2013 Base Package (Free) Ready-to-measure application software Configure, acquire, log, display, and analyze your data Customize many aspects of the acquisition, display, and recording functions to suit your needs FFT Analysis Option (License Required) Includes all the features of the QuickDAQ 2013 Base Package Perform single-channel FFT operations including: Auto Spectrum Spectrum Power Spectral Density Configure and view dynamic performance statistics Supports Hanning, Hamming, Bartlett, Blackman, Blackman Harris, and Flat Top response windows Advanced FFT Analysis Option (License Required) Includes all the features of the QuickDAQ 2013 Base Package and FFT Analysis Package Perform 2-channel FFT operations including: FRF Cross-Spectrum Cross Power Spectral Density Coherence Coherent Output Power Supports real, imaginary, and Nyquist display functions Additional FFT analysis functions supported: Exponential, Force, Cosiner Taper Save data to.uff file format Figure 3: QuickDAQ 2013 ships free-of-charge and allows you to get up and running quickly. Other Software Options There are many software choices available for application development, from ready-to-measure applications to programming environments. The following software is available for use with the DT9805 or DT9806 module and is provided on the Data Acquisition Omni CD: Device Driver The device driver allows you to use a DT9805 or DT9806 module with any of the supported software packages or utilities. Calibration Utility This utility allows you to calibrate features of a DT9805 or DT9806 module. Quick DataAcq application The Quick DataAcq application provides a quick way to get up and running. Using this application, verify key features of the module, display data on the screen, and save data to disk. DT-Open Layers for.net Class Library Use this class library if you want to use Visual C# or Visual Basic for.net to develop application software using Visual Studio 2003-2012; the class library complies with the DT-Open Layers standard. DataAcq SDK Use the Data Acq SDK to use Visual Studio 6.0 and Microsoft C or C++ to develop application software using Windows XP/Vista/7/8; the DataAcq SDK complies with the DT-Open Layers standard. DAQ Adaptor for MATLAB Data Translation s DAQ Adaptor provides an interface between the MATLAB Data Acquisition (DAQ) toolbox from The MathWorks and Data Translation s DT-Open Layers architecture. LV-Link Data Translation s LV-Link is a library of VIs that enable LabVIEW programmers to access the data acquisition features of DT-Open Layers compliant USB and PCI devices. 4

Cross-Series Compatibility Virtually all Data Translation data acquisition modules are compatible with the DT-Open Layers software standard. This means any application developed with one of Data Translation s software products can easily be upgrade to a new Data Translation module with little to no reprogramming needed. Technical Support Application engineers are available by phone and email during normal business hours to discuss your application requirements. Extensive product information, including drivers, example code, pinouts, a searchable Knowledge Base, and much more, is available 24 hours a day on our website at: www.datatranslation.com. HARDWARE Ordering Summary All Data Translation products are covered by a 1-year warranty. For pricing information, please visit our website or contact your local reseller. DT9805 USB function module with 16-bit, 50 ks/s analog inputs DT9806 USB function module with 16-bit, 50 ks/s analog inputs and two 16-bit analog outputs FREE SOFTWARE QuickDAQ 2013 DAQ Adaptor for MATLAB Access the analyzation and visualization tools of MATLAB. LV-Link Access the power of Data Translation boards through LabVIEW. OPTIONAL SOFTWARE QuickDAQ 2013 FFT Analysis Option (License Required) QuickDAQ 2013 Advanced FFT Analysis Option (License Required) Copyright 2013 Data Translation, Inc. All rights reserved. All trademarks are the property of their respective holders. Prices, availability, and specifications are subject to change without notice.