Ultra-Low Power Analog Sensor Module for Nitrogen Dioxide

Similar documents
How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

PortaSens ll G AS DETECTOR

Alphasense Application Note AAN DESIGNING A POTENTIOSTATIC CIRCUIT

The photoionization detector (PID) utilizes ultraviolet

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Gas sensors for greenhouse measurements

Automotive Air Quality Sensors: industrial innovations to protect people s health

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

HIH-4000 Series Humidity Sensors

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

DRM compatible RF Tuner Unit DRT1

T U R B I N E G A S M E T E R

Application Requirement

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Chlorine Gas Detection System Operation & Maintenance

Ultima X Series Gas Monitors

OEM-EP Pressure Controllers

GT Sensors Precision Gear Tooth and Encoder Sensors

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Airflow Sensors Line Guide

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

One Port Network Analyzer

Impedance 50 (75 connectors via adapters)

TSic 101/106/201/206/301/306/506 Rapid Response, Low-Cost Temperature Sensor IC with Analog or digital Output Voltage

HM1500LF Relative Humidity Module

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Product Datasheet P MHz RF Powerharvester Receiver

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SEMICONDUCTOR TECHNICAL DATA

SDI Multi Sensor Module with Charger Enclosure Station Support

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

a boiling point > 65 C

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

Tire pressure monitoring

Online Infrared Flue Gas Analyzer Gasboard 3000

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Fire & Security DETECTORS

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Analog Signal Conditioning

Mass Flow Meters & Controllers

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: GM32 ln-situ-gasanalysator model Cross Duct for NO and S02

Kit 27. 1W TDA7052 POWER AMPLIFIER

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems

iva Cable & Antenna Analyzer

Liquid Leakage Sensor Amplifier

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Wireless Precision Temperature Sensor Powers Itself, Forms Own Network, Enabling Easy Deployment in Industrial Environments

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Wideband Driver Amplifiers

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Understanding the Terms and Definitions of LDO Voltage Regulators

User Guide Dissolved Oxygen Probes

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

OZ-47 Smart Board with Metal Oxide Sensor For Ozone Monitoring

USB-500/600 Series Low-Cost Data Loggers and Accessories

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ALTAIR 5X Multigas Detector Bid Specification

Digital-output relative humidity & temperature sensor/module DHT22 (DHT22 also named as AM2302)

Operating principle and construction of zirconium dioxide oxygen sensors of the XYA series

MSFET MICROSENS Miniature ph Sensor Module

LynX TM Silicon Photomultiplier Module - LynX-A T1-A User Guide Understanding Silicon Photomultiplier Module for improving system performance

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

MAS.836 HOW TO BIAS AN OP-AMP

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

How To Use A Sound Card With A Subsonic Sound Card

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MicroMag3 3-Axis Magnetic Sensor Module

Description. 5k (10k) - + 5k (10k)

iva Cable & Antenna Analyzer

AA and AB-Series Analog Sensors

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Lockout Specification BW Clip Maintenance-free single gas detector

Aosong(Guangzhou) Electronics Co.,Ltd

Constant Voltage and Constant Current Controller for Adaptors and Battery Chargers

Voltage Output Temperature Sensor with Signal Conditioning AD22100

Section 3. Sensor to ADC Design Example

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

The Ambient Air Monitoring System

Cold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to C)

Data Sheet PS1B Pressure Switch

EzFlex Combustible Gas Leak Detector Model EZ40

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Model: DC-A2IO Advanced HVAC Controller

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Advanced Data Capture and Control Systems

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

Transcription:

Ultra-Low Power Analog Sensor Module for Nitrogen Dioxide BENEFITS 0 to 3 V Analog Signal Output Low Power Consumption < 45 µw Fast Response On-board Temperature Sensor Easy Sensor Replacement Standard 8-pin connector APPLICATIONS Fixed Industrial Safety Monitoring Portable Industrial Safety Monitoring Portable Personal Safety Monitor Indoor Air Quality Monitoring Outdoor Air Quality Monitoring Air Purification Control DESCRIPTION Quickly integrate Nitrogen Dioxide sensing into your system with very low power consumption and a simple analog sensor signal output. The ULPSM converts the Nitrogen Dioxide sensor s linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings. MEASUREMENT PERFORMANCE CHARACTERISTICS Measurement Range Lower Detection Limit Resolution Accuracy Response Time T90 Power-On Stabilization Time 0 to 20 ppm 0.3 ppm 0.15 ppm < ± 2 % of reading < 30 seconds 60 minutes recommended

ABSOLUTE MAXIMUM RATINGS Parameter Conditions Min. Rec. Max. Units Supply Voltage 2.7 3 3.3 V Storage Temperature Vapor sealed @ 50% RH 5 20 30 C Storage Humidity Non-condensing, Vapor sealed 20 50 80 % RH Storage Pressure Vapor sealed 0.8 1 1.2 atm. Storage Time Vapor sealed - 12 - Months Operating Temperature < 10 hours -40-50 C Operating Humidity < 10 hours, Non-condensing 0-100 % RH Operating Temperature Continuous -20 25 40 C Operating Humidity Continuous, Non-condensing 15 50 95 % RH Operating Pressure Continuous 0.8 1 1.2 Atm. ELECTRICAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Supply Current V+ = 3.0 V 5 10 15 µa Power Consumption V+ = 3.0 V 15 30 45 µw Vref V+/2 V 0.1 Vgas Zero (V+/2 (V+/2 (V+/2 V 0.1) 0.005 0.1) 0.1) + 0.005 Vgas Span (M) Room temperature -12.5-20 -27.5 mv/ppm

CALCULATING GAS CONCENTRATION The target gas concentration is calculated by the following method:, where Cx is the gas concentration (ppm), Vgas is the voltage output gas signal (V), Vgas0 is the voltage output gas signal in a clean-air environment (free of analyte gas) and M is the sensor calibration factor (V/ppm). The value, M, is calculated by the following method: 10 10, where the Sensitivity Code is provided on the sensor label and the TIA Gain is the gain of the trans-impedance amplifier (TIA) stage of the ULPSM circuit. Standard gain configurations are listed in the table below. The value Vgas0 can also be represented by:, where, Vref is the voltage output reference signal (V) and Voffset is a voltage offset factor. The Vref output acts as the reference voltage for zero concentration even as the battery voltage decreases. Measuring Vref in-situ compensates for variations in battery or supply voltage, minimizing these effects on Cx. A difference amplifier or instrumentation amplifier can be used to subtract Vref from Vgas. Alternatively, when measuring Vref directly, always use a unity gain buffer. Voffset, accounts for a small voltage offset that is caused by a normal sensor background current and circuit background voltage. To start, Voffset = 0 is an adequate approximation. To achieve higher-precision measurements, Voffset must be quantified. Once the sensor has been powered-on and allowed to stabilize in a clean-air environment (free of the analyte gas) and is providing a stable output within your application s measurement goals, the value of Vgas may be stored as Vgas0 and used in subsequent calculations of gas concentration, Cx. Target Gas TIA Gain (kv/a) Carbon Monoxide 100 Hydrogen Sulfide 49.9 Nitrogen Dioxide 499 Sulfur Dioxide 100 Ozone 499 Ethanol 249 Indoor Air Quality 100 Respiratory Irritants 499

TEMPERATURE COMPENSATION Temperature fluctuations have a predictable, easily compensated effect on the sensor signal. The figures below show the typical Temperature dependency of the output and baseline of Nitrogen Dioxide sensors under constant humidity of 40-50% RH. This is a very uniform and repeatable effect, easily compensated for in hardware or software. From the graphs above: The temperature effect of zero shift is expressed as ppm change. The temperature effect of span (sensitivity) is expressed with respect to sensitivity at the calibration temperature of 20 C. When implementing temperature compensation, first correct the temperature effect on the zero (offset) and then correct the temperature effect on the span (sensitivity) of the sensor. These corrections can be done in software by implementing one of the following: Curve fit Look up table A set of linear approximations, as outline in the following table. Temperature Coefficient of Span (%/ C) (Typical) Temperature Coefficient of Zero Shift (ppm/ C) (Typical) -20 C to 20 C -0.33%/ C 20 C to 40 C 0.26%/ C -20 C to 0 C 0.002 ppm/ C 0 C to 25 C 0.0 ppm/ C 25 C to 40 C -0.003 ppm/ C

CROSS SENSITIVITY Most chemical sensors exhibit some cross-sensitivity to other gases. The following table lists the relative response of common potential interfering gases, and the concentration at which the data was gathered. Gas/Vapor Applied Concentration (PPM) Typical Response (PPM NO2) Nitrogen Dioxide 10 10 Hydrogen Sulfide 25-6 Ozone 5 5 Nitric Oxide 50 0.2 Sulfur Dioxide 20 < 0.1 Carbon Monoxide 400 < 0.1 Chlorine 10 < 0.1 Methane 500 < 0.1 Ammonia 100 < 0.1 n-heptane 500 < 0.1 MARKING INFORMATION All gas sensors are tested and marked at the SPEC Sensors factory. Sensors include a label with an alphanumeric code and a two-dimensional bar code. The codes include the information indicated in the table below. (CO used for example)

PACKAGE OUTLINE DRAWING & DIMENSIONS

PINOUT Electrical connections to the ULPSM are made via a rectangular female socket connector (Sullins Connector Solutions P/N: PPPC041LGBN-RC; recommended mate for host board: P/N: PBC08SBAN). This connector also provides mechanical rigidity on one end of the board. A through-hole is located on the opposite end of the board to provide additional mechanical connection. Pin # ULPSM Function Notes 1 Vgas Voltage Output. Vgas is proportional to the target gas concentration. 2 Vref Voltage Output. Vref is approximately half the supply voltage. Useful as a fixed reference; equivalent to zero for Vgas. NOTE: High impedance output requires a buffer to connect to any measurement device. Voltage Output. Vtemp is proportional to temperature. 3 Vtemp 4 N/C 5 N/C NOTE: High impedance output requires a buffer to connect to any measurement device. 6 GND Universal ground for power and signal 7 V+ Voltage Supply Input: 2.7 to 3.3 V 8 V+ Voltage Supply Input: 2.7 to 3.3 V